Xali Gold Discovers Higher Grade Gold Mineralization at Pico Machay
Original announcement by orestocks on
- Company
- Xali Gold Corp.
- Ticker
- XGC
- Exchange
- TSXV
- Region
- Central Peru
- Primary commodity
- Gold
- Secondary commodities
- Silver
- Document categories
- Drill results
- Extracted
- 2026-10-01 03:12:27 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Xali Gold Corp. announced initial channel sampling results from its Pico Machay Gold Project in Central Peru, revealing high-grade gold mineralization. Highlights include 4.41 g/t Au over 13.7m from an underground channel and 2.28 g/t Au over 40.0m from a surface channel. These results, representing 25% of collected samples, are intended to validate and update the historical mineral resource estimate and support a Preliminary Economic Assessment.
Reasoning: Initial channel sampling results from the Pico Machay Gold Project show high-grade gold mineralization, with several intervals exceeding 4 g/t Au, which strengthens confidence in the project and will support an updated resource estimate and PEA.
Positive factors
- High-grade intercepts
- Continuity of mineralization
- QP/CP signed
- QA/QC disclosed
- Supports resource update and PEA
Negative factors
- Apparent width only
- Cut-off undisclosed
- Only 25% of samples reported
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 58
Classification and evidence
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Sample lengths represent true sample lengths along the channel and may not represent true widths of mineralization, which has no clear orientation.
Evidence · text
“Sample lengths represent true sample lengths along the channel and may not represent true widths of mineralization, which has no clear orientation.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: All scientific and technical information in this news release has been reviewed and approved by Joanne Freeze, P.Geo. and Ing. Enrique Bernuy, a qualified person for NI 43-101, and includes review of field duplicate results.
Evidence · text
“All scientific and technical information in this news release has been reviewed and approved by Joanne Freeze, P.Geo. and Ing. Enrique Bernuy. Ms. Freeze is the President and CEO of the Company and is a qualified person for the purposes of National Instrument 43-101 - Standards of Disclosure for Mineral Projects.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No cut-off grade is stated for the reported channel sample intervals.
Evidence · text
“Channel Assay Highlights”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The program aims to validate, update and potentially upgrade the historical mineral resource estimate at Pico Machay.
Evidence · text
“collected to support the Company's efforts to validate, update and potentially upgrade the historical mineral resource estimate at Pico Machay.”
Extracted facts
Stored fact records: 58. Some facts used in scoring do not have a stored record.
Drill Results (58)
Fact 1Pico Machay · goldGrade: 2.22Grade Unit: g/tIntercept: 45.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.22
- Grade Unit
- g/t
- Intercept
- 45.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows good width, but the grade is weak for an underground epithermal deposit, resulting in a strong GT product.
Positive factors
- Strong continuity of mineralization
- QA/QC disclosed
Negative factors
- Grade is weak for underground epithermal
- Apparent width only
- Cut-off undisclosed
Evidence · text
“2.22 g/t gold (“Au”) over 45.1meters (“m”) from Underground (“UG”) Channel 1”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 2Pico Machay · goldGrade: 4.17Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 4.17
- Grade Unit
- g/t
- Intercept
- 20 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This sub-interval shows a moderate grade and strong width for an underground epithermal deposit, resulting in a moderate GT product.
Positive factors
- Moderate grade for underground epithermal
- Strong continuity of mineralization
- QA/QC disclosed
Negative factors
- Apparent width only
- Cut-off undisclosed
Evidence · text
“4.17 g/t Au over 20.0m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 3Pico Machay · goldGrade: 1.49Grade Unit: g/tIntercept: 41.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.49
- Grade Unit
- g/t
- Intercept
- 41.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows good width, but the grade is below the weak threshold for an underground epithermal deposit, resulting in a moderate GT product.
Positive factors
- Strong continuity of mineralization
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Apparent width only
- Cut-off undisclosed
Evidence · text
“1.49 g/t Au over 41.1m from UG Channel 3 NS”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 4Pico Machay · goldGrade: 3.44Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 3.44
- Grade Unit
- g/t
- Intercept
- 8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This sub-interval shows a weak grade and moderate width for an underground epithermal deposit, resulting in a weak GT product.
Positive factors
- Moderate continuity of mineralization
- QA/QC disclosed
Negative factors
- Grade is weak for underground epithermal
- Apparent width only
- Cut-off undisclosed
Evidence · text
“3.44 g/t Au over 8.0m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 5Pico Machay · goldGrade: 4.41Grade Unit: g/tIntercept: 13.7 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 4.41
- Grade Unit
- g/t
- Intercept
- 13.7 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a moderate grade and moderate width for an underground epithermal deposit, resulting in a moderate GT product.
Positive factors
- Moderate grade for underground epithermal
- Moderate continuity of mineralization
- QA/QC disclosed
Negative factors
- Apparent width only
- Cut-off undisclosed
Evidence · text
“4.41 g/t Au over 13.7m from UG Channel 3 EW”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 6Pico Machay · goldGrade: 6.45Grade Unit: g/tIntercept: 6.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 6.45
- Grade Unit
- g/t
- Intercept
- 6.5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This sub-interval shows a moderate grade but narrow width for an underground epithermal deposit, resulting in a moderate GT product.
Positive factors
- Moderate grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · text
“6.45 g/t Au over 6.5m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 7Pico Machay · goldGrade: 2.28Grade Unit: g/tIntercept: 40 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.28
- Grade Unit
- g/t
- Intercept
- 40 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade and strong width for an open pit epithermal deposit, resulting in a moderate GT product.
Positive factors
- Strong grade for open pit epithermal
- Strong continuity of mineralization
- QA/QC disclosed
Negative factors
- Apparent width only
- Cut-off undisclosed
Evidence · text
“2.28 g/t Au over 40.0m from Surface Channel 2”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 8Pico Machay · goldGrade: 0.51Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.51
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.51”
Context: 2.00m x0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 9Pico Machay · goldGrade: 0.43Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.43”
Context: 5.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 10Pico Machay · goldGrade: 0.71Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.71
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.71”
Context: 4.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 11Pico Machay · goldGrade: 2.28Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.28
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.28”
Context: 4.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 12Pico Machay · goldGrade: 2.89Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.89
- Grade Unit
- g/t
- Intercept
- 5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a weak grade and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Grade is weak for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.89”
Context: 5.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 13Pico Machay · goldGrade: 8.3Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 8.3
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a strong grade but narrow width for an underground epithermal deposit, resulting in a weak GT product.
Positive factors
- Strong grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“8.30”
Context: 3.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 14Pico Machay · goldGrade: 7.48Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 7.48
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a strong grade but narrow width for an underground epithermal deposit, resulting in a weak GT product.
Positive factors
- Strong grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“7.48”
Context: 4.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 15Pico Machay · goldGrade: 1.26Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.26”
Context: 4.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 16Pico Machay · goldGrade: 0.57Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.57”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 17Pico Machay · goldGrade: 0.66Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.66
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.66”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 18Pico Machay · goldGrade: 1.13Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.13
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.13”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 19Pico Machay · goldGrade: 0.51Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.51
- Grade Unit
- g/t
- Intercept
- 2.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.51”
Context: 2.10m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 20Pico Machay · goldGrade: 0.08Grade Unit: g/tIntercept: 0.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a very low grade and narrow width for an underground epithermal deposit, indicating minimal mineralization.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is significantly below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.08”
Context: 0.10m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 21Pico Machay · goldGrade: 0.8Grade Unit: g/tIntercept: 4.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 4.3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.80”
Context: 4.30m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 22Pico Machay · goldGrade: 1.26Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 3.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.26”
Context: 3.80m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 23Pico Machay · goldGrade: 0.69Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.69
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.69”
Context: 4.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 24Pico Machay · goldGrade: 0.55Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.55”
Context: 3.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 25Pico Machay · goldGrade: 1.11Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.11
- Grade Unit
- g/t
- Intercept
- 5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.11”
Context: 5.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 26Pico Machay · goldGrade: 3.43Grade Unit: g/tIntercept: 4.4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 3.43
- Grade Unit
- g/t
- Intercept
- 4.4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a weak grade and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Grade is weak for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“3.43”
Context: 4.40m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 27Pico Machay · goldGrade: 6.7Grade Unit: g/tIntercept: 4.4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 6.7
- Grade Unit
- g/t
- Intercept
- 4.4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a moderate grade but narrow width for an underground epithermal deposit, resulting in a weak GT product.
Positive factors
- Moderate grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“6.70”
Context: 4.40m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 28Pico Machay · goldGrade: 1.46Grade Unit: g/tIntercept: 3.6 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.46
- Grade Unit
- g/t
- Intercept
- 3.6 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.46”
Context: 3.60m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 29Pico Machay · goldGrade: 0.92Grade Unit: g/tIntercept: 4.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.92
- Grade Unit
- g/t
- Intercept
- 4.3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.92”
Context: 4.30m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 30Pico Machay · goldGrade: 0.82Grade Unit: g/tIntercept: 3.7 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.82
- Grade Unit
- g/t
- Intercept
- 3.7 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.82”
Context: 3.70m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 31Pico Machay · goldGrade: 1.78Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.78
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.78”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 32Pico Machay · goldGrade: 1.34Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.34
- Grade Unit
- g/t
- Intercept
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.34”
Context: 1.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 33Pico Machay · goldGrade: 0.81Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 2.2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“0.81”
Context: 2.20m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 34Pico Machay · goldGrade: 4.74Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 4.74
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a moderate grade but narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“4.74”
Context: 2.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 35Pico Machay · goldGrade: 2.41Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.41
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a grade below the weak threshold and narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is below weak for underground epithermal
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.41”
Context: 3.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 36Pico Machay · goldGrade: 8.79Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 8.79
- Grade Unit
- g/t
- Intercept
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a strong grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“8.79”
Context: 0.60m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 37Pico Machay · goldGrade: 7.07Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 7.07
- Grade Unit
- g/t
- Intercept
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a strong grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“7.07”
Context: 1.10m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 38Pico Machay · goldGrade: 8.19Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 8.19
- Grade Unit
- g/t
- Intercept
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a strong grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“8.19”
Context: 1.80m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 39Pico Machay · goldGrade: 4.24Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 4.24
- Grade Unit
- g/t
- Intercept
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a moderate grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“4.24”
Context: 1.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 40Pico Machay · goldGrade: 5.77Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 5.77
- Grade Unit
- g/t
- Intercept
- 1.2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a moderate grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“5.77”
Context: 1.20m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 41Pico Machay · goldGrade: 3.73Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 3.73
- Grade Unit
- g/t
- Intercept
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 EW
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This channel sample shows a weak grade but very narrow width for an underground epithermal deposit, resulting in a GT product below weak.
Positive factors
- Grade is weak for underground epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“3.73”
Context: 0.80m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 42Pico Machay · goldGrade: 1.83Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.83
- Grade Unit
- g/t
- Intercept
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.83”
Context: 1.80m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 43Pico Machay · goldGrade: 2.69Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.69
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.69”
Context: 3.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 44Pico Machay · goldGrade: 1.74Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.74
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.74”
Context: 2.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 45Pico Machay · goldGrade: 1.05Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.05
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a moderate grade and narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.05”
Context: 3.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 46Pico Machay · goldGrade: 2.37Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.37
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.37”
Context: 3.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 47Pico Machay · goldGrade: 2.6Grade Unit: g/tIntercept: 3.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.6
- Grade Unit
- g/t
- Intercept
- 3.5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.60”
Context: 3.50m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 48Pico Machay · goldGrade: 2.21Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.21
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.21”
Context: 3.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 49Pico Machay · goldGrade: 2.21Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.21
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.21”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 50Pico Machay · goldGrade: 2.28Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 2.28
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“2.28”
Context: 4.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 51Pico Machay · goldGrade: 5.58Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 5.58
- Grade Unit
- g/t
- Intercept
- 1.5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows an exceptional grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Exceptional grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“5.58”
Context: 1.50m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 52Pico Machay · goldGrade: 1.87Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.87
- Grade Unit
- g/t
- Intercept
- 1.2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.87”
Context: 1.20m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 53Pico Machay · goldGrade: 1.35Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.35
- Grade Unit
- g/t
- Intercept
- 2.1 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a moderate grade and narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.35”
Context: 2.10m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 54Pico Machay · goldGrade: 3.39Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 3.39
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows an exceptional grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Exceptional grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“3.39”
Context: 2.00m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 55Pico Machay · goldGrade: 1.41Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.41
- Grade Unit
- g/t
- Intercept
- 2.5 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a moderate grade and narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Moderate grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.41”
Context: 2.50m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 56Pico Machay · goldGrade: 1.79Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.79
- Grade Unit
- g/t
- Intercept
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.79”
Context: 1.80m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 57Pico Machay · goldGrade: 3.49Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 3.49
- Grade Unit
- g/t
- Intercept
- 2.6 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows an exceptional grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Exceptional grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“3.49”
Context: 2.60m x 0.20m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Fact 58Pico Machay · goldGrade: 1.88Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- Central Peru
- Ticker
- XGC
Geometry
- Grade
- 1.88
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- channel
- Mining Method
- open_pit
Location
- Location
- Surface Channel 2
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-25T00:00:00.000Z
Reasoning: This surface channel sample shows a strong grade but narrow width for an open pit epithermal deposit, resulting in a GT product below weak.
Positive factors
- Strong grade for open pit epithermal
- QA/QC disclosed
Negative factors
- Narrow continuity of mineralization
- Apparent width only
- Cut-off undisclosed
Evidence · table
“1.88”
Context: 3.00m x 0.30m
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.