Sterling Extends Core MEPS Copper Zone to 700m; Intersects 200m of 0.53% CuEq Including 102m of 0.81% CuEq

Original announcement by prospectors_exchange on

Company
Sterling Metals Corp.
Ticker
SAG
Exchange
Unavailable
Region
Ontario
Primary commodity
Copper
Secondary commodities
Gold, Silver, Molybdenum
Document categories
Drill results
Extracted
2026-09-16 16:54:26 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Sterling Metals has extended the MEPS copper zone to a 700m strike length following successful step-out drilling at the Soo Copper Project. Drill hole SC-26-26 intersected a significant 200m interval of 0.53% CuEq, including high-grade segments of 0.81% and 1.82% CuEq.

Reasoning: Significant step-out drilling extending the MEPS copper zone by 300m westward with high-grade CuEq intercepts and strong continuity.

Positive factors

  • Step-Out Extension
  • QA/QC Disclosed
  • Continuous mineralization

Negative factors

  • Apparent Width Only

Facts used in scoring: 44

Classification and evidence

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: Drilling 300m west of discovery extends the MEPS Copper Zone to 700m.

Evidence · text

“This is an important step-out for the MEPS discovery. Approximately 300 metres west of our initial discovery”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release details laboratory (Actlabs), accreditation (ISO 17025), and specific QA/QC methods used.

Evidence · text

“Analytical services were provided by Actlabs, which is an independent, CALA- and SCC-accredited analytical services firm registered to ISO 17025”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document states that intervals may not represent true widths, which are not yet known.

Evidence · text

“Intervals may not represent true widths, which are not yet known”

Extracted facts

Stored fact records: 44. Some facts used in scoring do not have a stored record.

Drill Results (44)

SC-26-25Soo · copperGrade: 0.28Grade Unit: %Intercept: 128 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.28
Grade Unit
%
Intercept
128 m
From
157 m
To
285 m
Intercept Depth
157 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-25:157-285
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate grade intercept in a large continuous zone.

Evidence · table

“0.28”

Context: 128.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · goldGrade: 0.01Grade Unit: g/tIntercept: 128 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
128 m
From
157 m
To
285 m
Intercept Depth
157 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-25:157-285
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Trace gold grade.

Evidence · table

“0.01”

Context: 128.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · silverGrade: 1.14Grade Unit: g/tIntercept: 128 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.14
Grade Unit
g/t
Intercept
128 m
From
157 m
To
285 m
Intercept Depth
157 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-25:157-285
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Trace silver grade.

Evidence · table

“1.14”

Context: 128.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · molybdenumGrade: 5Grade Unit: ppmIntercept: 128 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
5
Grade Unit
ppm
Intercept
128 m
From
157 m
To
285 m
Intercept Depth
157 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-25:157-285
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Trace molybdenum grade.

Evidence · table

“5”

Context: 128.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 0.3Grade Unit: %Intercept: 397.19 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.3
Grade Unit
%
Intercept
397.19 m
From
8.51 m
To
406.05 m
Intercept Depth
8.51 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:8.51-406.05
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Very wide intercept of continuous mineralization, though true width is not stated.

Positive factors

  • Step-Out Extension

Negative factors

  • Apparent Width Only

Evidence · table

“0.30”

Context: 397.19

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · goldGrade: 0.03Grade Unit: g/tIntercept: 397.19 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
397.19 m
From
8.51 m
To
406.05 m
Intercept Depth
8.51 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:8.51-406.05
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Trace gold grade.

Evidence · table

“0.03”

Context: 397.19

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · silverGrade: 1.07Grade Unit: g/tIntercept: 397.19 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.07
Grade Unit
g/t
Intercept
397.19 m
From
8.51 m
To
406.05 m
Intercept Depth
8.51 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:8.51-406.05
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Trace silver grade.

Evidence · table

“1.07”

Context: 397.19

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · molybdenumGrade: 63Grade Unit: ppmIntercept: 397.19 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
63
Grade Unit
ppm
Intercept
397.19 m
From
8.51 m
To
406.05 m
Intercept Depth
8.51 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:8.51-406.05
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Elevated molybdenum grade in a large intercept.

Evidence · table

“63”

Context: 397.19

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 0.65Grade Unit: %Intercept: 101.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.65
Grade Unit
%
Intercept
101.9 m
From
224.1 m
To
326 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:224.1-326
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Strong intercept within the core zone.

Evidence · table

“0.65”

Context: 101.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 0.98Grade Unit: %Intercept: 29.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.98
Grade Unit
%
Intercept
29.9 m
From
224.1 m
To
254 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:224.1-254
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: High-grade sub-interval.

Evidence · table

“0.98”

Context: 29.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 1.03Grade Unit: %Intercept: 13.25 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.03
Grade Unit
%
Intercept
13.25 m
From
282 m
To
295.25 m
Intercept Depth
282 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
SC-26-26:282-295.25
Mining Method
open_pit

Location

Loc. Confidence
high

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: High-grade intercept.

Evidence · table

“1.03”

Context: 13.25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · copperGrade: 0.37Grade Unit: %Intercept: 82 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.37
Grade Unit
%
Intercept
82 m
From
198 m
To
280 m
Intercept Depth
198 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:198-280
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % copper is moderate against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 30.3 %·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.37”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · goldGrade: 0.02Grade Unit: g/tIntercept: 82 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
82 m
From
198 m
To
280 m
Intercept Depth
198 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:198-280
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 1.6 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · silverGrade: 1.26Grade Unit: g/tIntercept: 82 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.26
Grade Unit
g/t
Intercept
82 m
From
198 m
To
280 m
Intercept Depth
198 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:198-280
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.26 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 103.3 g/t·m is below.

Negative factors

  • 1.26 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.26”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · molybdenumGrade: 6Grade Unit: ppmIntercept: 82 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
6
Grade Unit
ppm
Intercept
82 m
From
198 m
To
280 m
Intercept Depth
198 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:198-280
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“6”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · copperGrade: 0.8Grade Unit: %Intercept: 24 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.8
Grade Unit
%
Intercept
24 m
From
244 m
To
268 m
Intercept Depth
244 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:244-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % copper is exceptional against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 19.2 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 0.8 % copper is exceptional on the porphyry deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.80”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · goldGrade: 0.03Grade Unit: g/tIntercept: 24 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
24 m
From
244 m
To
268 m
Intercept Depth
244 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:244-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · silverGrade: 2.29Grade Unit: g/tIntercept: 24 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
2.29
Grade Unit
g/t
Intercept
24 m
From
244 m
To
268 m
Intercept Depth
244 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:244-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.29 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 55.0 g/t·m is below.

Negative factors

  • 2.29 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.29”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · molybdenumGrade: 9Grade Unit: ppmIntercept: 24 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
9
Grade Unit
ppm
Intercept
24 m
From
244 m
To
268 m
Intercept Depth
244 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:244-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“9”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · copperGrade: 0.92Grade Unit: %Intercept: 16 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.92
Grade Unit
%
Intercept
16 m
From
252 m
To
268 m
Intercept Depth
252 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:252-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.92 % copper is exceptional against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 14.7 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 0.92 % copper is exceptional on the porphyry deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.92”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · goldGrade: 0.03Grade Unit: g/tIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
16 m
From
252 m
To
268 m
Intercept Depth
252 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:252-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · silverGrade: 2.73Grade Unit: g/tIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
2.73
Grade Unit
g/t
Intercept
16 m
From
252 m
To
268 m
Intercept Depth
252 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:252-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.73 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 43.7 g/t·m is below.

Negative factors

  • 2.73 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.73”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25Soo · molybdenumGrade: 6Grade Unit: ppmIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
6
Grade Unit
ppm
Intercept
16 m
From
252 m
To
268 m
Intercept Depth
252 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-25:252-268
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“6”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 0.32Grade Unit: %Intercept: 347.05 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.32
Grade Unit
%
Intercept
347.05 m
From
59 m
To
406.05 m
Intercept Depth
59 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:59-406.05
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % copper is moderate against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 111.1 %·m is moderate.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.32”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · goldGrade: 0.03Grade Unit: g/tIntercept: 347.05 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
347.05 m
From
59 m
To
406.05 m
Intercept Depth
59 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:59-406.05
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is weak against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 10.4 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · silverGrade: 1.15Grade Unit: g/tIntercept: 347.05 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.15
Grade Unit
g/t
Intercept
347.05 m
From
59 m
To
406.05 m
Intercept Depth
59 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:59-406.05
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.15 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 399.1 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.15”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · molybdenumGrade: 72Grade Unit: ppmIntercept: 347.05 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
72
Grade Unit
ppm
Intercept
347.05 m
From
59 m
To
406.05 m
Intercept Depth
59 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:59-406.05
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 72 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“72”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · copperGrade: 0.42Grade Unit: %Intercept: 200 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.42
Grade Unit
%
Intercept
200 m
From
148 m
To
348 m
Intercept Depth
148 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:148-348
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.42 % copper is strong against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 84.0 %·m is moderate (grade alone is strong; the better of the two is used).

Positive factors

  • 0.42 % copper is strong on the porphyry deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.42”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · goldGrade: 0.04Grade Unit: g/tIntercept: 200 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
200 m
From
148 m
To
348 m
Intercept Depth
148 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:148-348
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 8.0 g/t·m is below.

Negative factors

  • 0.04 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · silverGrade: 1.42Grade Unit: g/tIntercept: 200 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.42
Grade Unit
g/t
Intercept
200 m
From
148 m
To
348 m
Intercept Depth
148 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:148-348
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.42 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 284.0 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.42”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · molybdenumGrade: 94Grade Unit: ppmIntercept: 200 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
94
Grade Unit
ppm
Intercept
200 m
From
148 m
To
348 m
Intercept Depth
148 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:148-348
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 94 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“94”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · goldGrade: 0.07Grade Unit: g/tIntercept: 101.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
101.9 m
From
224.1 m
To
326 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-326
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 7.1 g/t·m is below.

Negative factors

  • 0.07 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · silverGrade: 2.19Grade Unit: g/tIntercept: 101.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
2.19
Grade Unit
g/t
Intercept
101.9 m
From
224.1 m
To
326 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-326
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.19 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 223.2 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.19”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · molybdenumGrade: 152Grade Unit: ppmIntercept: 101.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
152
Grade Unit
ppm
Intercept
101.9 m
From
224.1 m
To
326 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-326
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 152 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“152”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · goldGrade: 0.04Grade Unit: g/tIntercept: 29.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
29.9 m
From
224.1 m
To
254 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-254
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 1.2 g/t·m is below.

Negative factors

  • 0.04 g/t gold is below the weak threshold (0.15 g/t) on the porphyry deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · silverGrade: 1.69Grade Unit: g/tIntercept: 29.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.69
Grade Unit
g/t
Intercept
29.9 m
From
224.1 m
To
254 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-254
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.69 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 50.5 g/t·m is below.

Negative factors

  • 1.69 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.69”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-26Soo · molybdenumGrade: 96Grade Unit: ppmIntercept: 29.9 mView all details
Link to this fact

Identity

Hole ID
SC-26-26
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
96
Grade Unit
ppm
Intercept
29.9 m
From
224.1 m
To
254 m
Intercept Depth
224.1 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
SC-26-26:224.1-254
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 96 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“96”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

andSoo · copperGrade: 1.03Grade Unit: %Intercept: 13.25 mView all details
Link to this fact

Identity

Hole ID
and
Project
Soo
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
1.03
Grade Unit
%
Intercept
13.25 m
From
282 m
To
295.25 m
Intercept Depth
282 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
and:282-295.25
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.03 % copper is exceptional against the porphyry deposit band [0.8, 0.4, 0.25, 0.15] %. Grade×width 13.6 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1.03 % copper is exceptional on the porphyry deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.03”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

andSoo · goldGrade: 0.3Grade Unit: g/tIntercept: 13.25 mView all details
Link to this fact

Identity

Hole ID
and
Project
Soo
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
13.25 m
From
282 m
To
295.25 m
Intercept Depth
282 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
and:282-295.25
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 g/t gold is moderate against the porphyry deposit band [1, 0.5, 0.3, 0.15] g/t. Grade×width 4.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.30”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

andSoo · silverGrade: 7.6Grade Unit: g/tIntercept: 13.25 mView all details
Link to this fact

Identity

Hole ID
and
Project
Soo
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
7.6
Grade Unit
g/t
Intercept
13.25 m
From
282 m
To
295.25 m
Intercept Depth
282 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
and:282-295.25
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table. 7.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 100.7 g/t·m is below.

Negative factors

  • 7.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.60”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

andSoo · molybdenumGrade: 837Grade Unit: ppmIntercept: 13.25 mView all details
Link to this fact

Identity

Hole ID
and
Project
Soo
Commodity
molybdenum
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Grade
837
Grade Unit
ppm
Intercept
13.25 m
From
282 m
To
295.25 m
Intercept Depth
282 m

Classification

Deposit Type
porphyry
Sample Type
drill
Group ID
and:282-295.25
Mining Method
open_pit

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Expanded from assay table: 837 ppm molybdenum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for molybdenum; intercept not scored.

Evidence · table

“837”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25SooIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Intercept
0.35 m

Classification

Deposit Type
porphyry
Sample Type
drill

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.71
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate grade intercept in a large continuous zone.

Evidence · text

“2.71% CuEq over 0.35m”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used.

Why it applies: an equivalent grade is reported without its assumptions

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25SooIntercept: 200 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Intercept
200 m

Classification

Deposit Type
porphyry
Sample Type
drill

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate grade intercept in a large continuous zone.

Evidence · text

“200m of 0.53% CuEq”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used.

Why it applies: an equivalent grade is reported without its assumptions

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

SC-26-25SooIntercept: 102 mView all details
Link to this fact

Identity

Hole ID
SC-26-25
Project
Soo
Region
canada_on
Reported Region
canada_on
Ticker
SAG

Geometry

Intercept
102 m

Classification

Deposit Type
porphyry
Sample Type
drill

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate grade intercept in a large continuous zone.

Evidence · text

“102m of 0.81% CuEq”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used.

Why it applies: an equivalent grade is reported without its assumptions

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Sterling Metals - News Corporate About Us Management Board of Directors Advisors Projects Soo Copper Project Core Galler"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.