SOQUEM intersects 263.20 m at 3.96% ZnEq, including 105.00 m at 7.03% ZnEq, confirming the extent of the Detour-Selbaie Zone on the Wagosic Project
Original announcement by cnw on
- Company
- SOQUEM
- Ticker
- Unavailable
- Exchange
- Unavailable
- Region
- Quebec
- Primary commodity
- Zinc
- Secondary commodities
- Silver, Copper, Gold, Lead
- Document categories
- Drill results, Metallurgy
- Extracted
- 2026-09-15 11:53:13 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
SOQUEM has announced final results from its winter 2025-2026 exploration drilling program on the Wagosic Project in Quebec, intersecting significant polymetallic mineralization. Highlights include 263.20 m at 3.96% ZnEq, including 105.00 m at 7.03% ZnEq, in the Detour-Selbaie Zone, and 54.80 m at 184.2 g/t AgEq, including 4.60 m at 820.1 g/t AgEq, in the Silver 2 Zone. These results confirm the continuity of mineralization over more than a kilometre strike length and 700 m vertical extent, with both zones remaining open for further expansion. The company plans an additional 15,000 m drilling program for winter 2026-2027 and has metallurgical testwork underway.
Reasoning: SOQUEM's drilling program on the Wagosic Project has returned several long, high-grade polymetallic intercepts, significantly extending the known mineralization in both the Detour-Selbaie and Silver 2 Zones. The results confirm continuity over substantial strike and vertical extents, with mineralization remaining open, suggesting strong potential for further expansion. The disclosure of detailed QA/QC protocols and metal equivalent assumptions adds credibility to the results. However, the lack of true width reporting and the inclusion of some previously announced results temper the overall novelty.
Positive factors
- High-grade polymetallic intercepts, particularly in ZnEq and AgEq
- Significant intercept lengths confirming continuity over large strike and vertical extents
- Mineralization remains open in multiple directions, indicating further exploration potential
- Comprehensive QA/QC protocols disclosed, including certified lab and QP sign-off
- Metal equivalent assumptions fully disclosed
Negative factors
- No true width disclosed for intercepts, potentially overstating thickness
- Some reported intervals include previously announced results, reducing novelty for those specific intercepts
Facts used in scoring: 276
Extracted facts
Stored fact records: 276. Some facts used in scoring do not have a stored record.
Drill Results (276)
1338-26-093AWagosic · copperGrade: 0.18Grade Unit: %Intercept: 275.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 275.6 m
- From
- 856.4 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:856.4-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.59
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the copper grade is low for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Low copper grade for VMS deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.18”
Context: 275.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · zincGrade: 2.59Grade Unit: %Intercept: 275.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 2.59
- Grade Unit
- %
- Intercept
- 275.6 m
- From
- 856.4 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:856.4-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.59
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the ZnEq grade is weak for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“2.59”
Context: 275.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · goldGrade: 0.15Grade Unit: g/tIntercept: 275.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 275.6 m
- From
- 856.4 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:856.4-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.59
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the gold grade is very low for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.15”
Context: 275.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · silverGrade: 34.2Grade Unit: g/tIntercept: 275.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 34.2
- Grade Unit
- g/t
- Intercept
- 275.6 m
- From
- 856.4 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:856.4-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.59
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the silver grade is weak for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Silver grade is weak for VMS-epithermal deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“34.2”
Context: 275.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · leadGrade: 0.03Grade Unit: %Intercept: 275.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 275.6 m
- From
- 856.4 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:856.4-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.59
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the lead grade is very low. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.03”
Context: 275.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · copperGrade: 0.03Grade Unit: %Intercept: 106.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the copper grade is very low for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.03”
Context: 106.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · zincGrade: 3.81Grade Unit: %Intercept: 106.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.81
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the ZnEq grade is weak for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“3.81”
Context: 106.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · goldGrade: 0.06Grade Unit: g/tIntercept: 106.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the gold grade is very low for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.06”
Context: 106.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · silverGrade: 80.5Grade Unit: g/tIntercept: 106.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 80.5
- Grade Unit
- g/t
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the silver grade is weak for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Silver grade is weak for VMS-epithermal deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“80.5”
Context: 106.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · leadGrade: 0.08Grade Unit: %Intercept: 106.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the lead grade is very low. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.08”
Context: 106.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · copperGrade: 0.03Grade Unit: %Intercept: 21.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.03”
Context: 21.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · zincGrade: 12.04Grade Unit: %Intercept: 21.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 12.04
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a strong ZnEq grade for a VMS deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Strong ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“12.04”
Context: 21.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · goldGrade: 0.12Grade Unit: g/tIntercept: 21.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.12”
Context: 21.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · silverGrade: 334Grade Unit: g/tIntercept: 21.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 334
- Grade Unit
- g/t
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade for a VMS-epithermal deposit. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Strong silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“334.0”
Context: 21.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · leadGrade: 0.15Grade Unit: %Intercept: 21.75 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-03-01T00:00:00.000Z
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low lead grade. The fact that it includes previously reported results reduces its novelty, and only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low lead grade
- Intercept includes previously reported results, reducing novelty
- Apparent width only
Evidence · table
“0.15”
Context: 21.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
1338-26-093AWagosic · copperGrade: 0.39Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the copper grade is low for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.39”
Context: 115.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · zincGrade: 2.37Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 2.37
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the ZnEq grade is weak for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Apparent width only
Evidence · table
“2.37”
Context: 115.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · goldGrade: 0.27Grade Unit: g/tIntercept: 115 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the gold grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.27”
Context: 115.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · silverGrade: 6.3Grade Unit: g/tIntercept: 115 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 6.3
- Grade Unit
- g/t
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the silver grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“6.3”
Context: 115.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · leadGrade: 0.01Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the lead grade is very low. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.01”
Context: 115.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · copperGrade: 1Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“1.00”
Context: 20.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · zincGrade: 5.38Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 5.38
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“5.38”
Context: 20.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · goldGrade: 0.57Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.57”
Context: 20.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · silverGrade: 13.9Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 13.9
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“13.9”
Context: 20.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-093AWagosic · leadGrade: 0Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- 1338-26-093A
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 856.4 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-093A:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept reports no lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- No lead grade reported
- Apparent width only
Evidence · table
“0.00”
Context: 20.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · copperGrade: 0.03Grade Unit: %Intercept: 294 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 294 m
- From
- 415 m
- To
- 709 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-709
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.48
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the copper grade is very low for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.03”
Context: 294.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · zincGrade: 1.48Grade Unit: %Intercept: 294 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.48
- Grade Unit
- %
- Intercept
- 294 m
- From
- 415 m
- To
- 709 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-709
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.48
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the ZnEq grade is weak for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Apparent width only
Evidence · table
“1.48”
Context: 294.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · goldGrade: 0.04Grade Unit: g/tIntercept: 294 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 294 m
- From
- 415 m
- To
- 709 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-709
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.48
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the gold grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.04”
Context: 294.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · silverGrade: 24.2Grade Unit: g/tIntercept: 294 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 24.2
- Grade Unit
- g/t
- Intercept
- 294 m
- From
- 415 m
- To
- 709 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-709
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.48
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the silver grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“24.2”
Context: 294.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · leadGrade: 0.02Grade Unit: %Intercept: 294 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 294 m
- From
- 415 m
- To
- 709 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-709
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.48
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the lead grade is very low. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.02”
Context: 294.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.01”
Context: 33.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · zincGrade: 4.72Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 4.72
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“4.72”
Context: 33.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · goldGrade: 0.02Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.02”
Context: 33.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · silverGrade: 137.3Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 137.3
- Grade Unit
- g/t
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Moderate silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“137.3”
Context: 33.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · leadGrade: 0.03Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.03”
Context: 33.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · copperGrade: 0.04Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.04”
Context: 12.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · zincGrade: 3.51Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.51
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.51”
Context: 12.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · goldGrade: 0.15Grade Unit: g/tIntercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.15”
Context: 12.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · silverGrade: 19.5Grade Unit: g/tIntercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 19.5
- Grade Unit
- g/t
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“19.5”
Context: 12.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-094Wagosic · leadGrade: 0.01Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-094
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-094:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.01”
Context: 12.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · copperGrade: 0.08Grade Unit: %Intercept: 294.5 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 294.5 m
- From
- 630.5 m
- To
- 925 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-925
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.32
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the copper grade is very low for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.08”
Context: 294.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · zincGrade: 1.32Grade Unit: %Intercept: 294.5 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.32
- Grade Unit
- %
- Intercept
- 294.5 m
- From
- 630.5 m
- To
- 925 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-925
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.32
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the ZnEq grade is weak for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Apparent width only
Evidence · table
“1.32”
Context: 294.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · goldGrade: 0.06Grade Unit: g/tIntercept: 294.5 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 294.5 m
- From
- 630.5 m
- To
- 925 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-925
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.32
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the gold grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.06”
Context: 294.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · silverGrade: 10.9Grade Unit: g/tIntercept: 294.5 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 10.9
- Grade Unit
- g/t
- Intercept
- 294.5 m
- From
- 630.5 m
- To
- 925 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-925
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.32
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the silver grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“10.9”
Context: 294.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · leadGrade: 0.03Grade Unit: %Intercept: 294.5 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 294.5 m
- From
- 630.5 m
- To
- 925 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-925
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.32
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept, but the lead grade is very low. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.03”
Context: 294.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · copperGrade: 0.02Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.02”
Context: 17.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · zincGrade: 3.36Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.36
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.36”
Context: 17.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.08”
Context: 17.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · silverGrade: 34.5Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 34.5
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“34.5”
Context: 17.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · leadGrade: 0.1Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low lead grade
- Apparent width only
Evidence · table
“0.10”
Context: 17.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · copperGrade: 0.01Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.01”
Context: 16.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · zincGrade: 3.25Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.25
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.25”
Context: 16.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · goldGrade: 0.44Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.44”
Context: 16.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · silverGrade: 10.4Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 10.4
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“10.4”
Context: 16.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · leadGrade: 0.08Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low lead grade
- Apparent width only
Evidence · table
“0.08”
Context: 16.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · copperGrade: 0.93Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.93
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“0.93”
Context: 13.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · zincGrade: 5.51Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 5.51
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“5.51”
Context: 13.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · goldGrade: 0.26Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.26”
Context: 13.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · silverGrade: 34.2Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 34.2
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“34.2”
Context: 13.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-25-095BWagosic · leadGrade: 0.04Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- 1338-25-095B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-25-095B:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.04”
Context: 13.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 121.3 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 121.3 m
- From
- 473.2 m
- To
- 594.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:473.2-594.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.08
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the copper grade is very low for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.01”
Context: 121.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · zincGrade: 1.08Grade Unit: %Intercept: 121.3 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.08
- Grade Unit
- %
- Intercept
- 121.3 m
- From
- 473.2 m
- To
- 594.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:473.2-594.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.08
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the ZnEq grade is weak for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Apparent width only
Evidence · table
“1.08”
Context: 121.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · goldGrade: 0.03Grade Unit: g/tIntercept: 121.3 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 121.3 m
- From
- 473.2 m
- To
- 594.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:473.2-594.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.08
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the gold grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.03”
Context: 121.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · silverGrade: 14Grade Unit: g/tIntercept: 121.3 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 14
- Grade Unit
- g/t
- Intercept
- 121.3 m
- From
- 473.2 m
- To
- 594.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:473.2-594.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.08
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the silver grade is very low for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“14.0”
Context: 121.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · leadGrade: 0.11Grade Unit: %Intercept: 121.3 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 121.3 m
- From
- 473.2 m
- To
- 594.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:473.2-594.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.08
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept, but the lead grade is low. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Low lead grade
- Apparent width only
Evidence · table
“0.11”
Context: 121.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.01”
Context: 17.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · zincGrade: 3Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.00”
Context: 17.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.08”
Context: 17.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · silverGrade: 32.4Grade Unit: g/tIntercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 32.4
- Grade Unit
- g/t
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“32.4”
Context: 17.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-099Wagosic · leadGrade: 0.44Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-099
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.44
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 473.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-099:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low lead grade
- Apparent width only
Evidence · table
“0.44”
Context: 17.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · copperGrade: 0.4Grade Unit: %Intercept: 263.2 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 263.2 m
- From
- 532.9 m
- To
- 796.1 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:532.9-796.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.96
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a weak copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Weak copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“0.40”
Context: 263.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · zincGrade: 3.96Grade Unit: %Intercept: 263.2 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.96
- Grade Unit
- %
- Intercept
- 263.2 m
- From
- 532.9 m
- To
- 796.1 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:532.9-796.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.96
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.96”
Context: 263.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 263.2 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 263.2 m
- From
- 532.9 m
- To
- 796.1 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:532.9-796.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.96
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.08”
Context: 263.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · silverGrade: 29.1Grade Unit: g/tIntercept: 263.2 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 29.1
- Grade Unit
- g/t
- Intercept
- 263.2 m
- From
- 532.9 m
- To
- 796.1 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:532.9-796.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.96
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“29.1”
Context: 263.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · leadGrade: 0.05Grade Unit: %Intercept: 263.2 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 263.2 m
- From
- 532.9 m
- To
- 796.1 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:532.9-796.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.96
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low lead grade. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.05”
Context: 263.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · copperGrade: 0.77Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.77
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept with a weak copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Weak copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“0.77”
Context: 105.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · zincGrade: 7.03Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 7.03
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept with a strong ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Strong ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“7.03”
Context: 105.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · goldGrade: 0.1Grade Unit: g/tIntercept: 105 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept with a very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.10”
Context: 105.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · silverGrade: 36.6Grade Unit: g/tIntercept: 105 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 36.6
- Grade Unit
- g/t
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept with a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Long intercept length
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“36.6”
Context: 105.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · leadGrade: 0.04Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a long intercept with a very low lead grade. Only apparent width is provided.
Positive factors
- Long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.04”
Context: 105.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · copperGrade: 1.96Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.96
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a strong copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Strong copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“1.96”
Context: 39.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · zincGrade: 13Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 13
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a strong ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Strong ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“13.00”
Context: 39.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · goldGrade: 0.18Grade Unit: g/tIntercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.18”
Context: 39.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · silverGrade: 67.5Grade Unit: g/tIntercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 67.5
- Grade Unit
- g/t
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“67.5”
Context: 39.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · leadGrade: 0.03Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.03”
Context: 39.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · copperGrade: 1.02Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“1.02”
Context: 17.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · zincGrade: 6.38Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 6.38
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a strong ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Strong ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“6.38”
Context: 17.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · goldGrade: 0.23Grade Unit: g/tIntercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.23”
Context: 17.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · silverGrade: 46.2Grade Unit: g/tIntercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 46.2
- Grade Unit
- g/t
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Weak silver grade for VMS-epithermal deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“46.2”
Context: 17.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · leadGrade: 0.02Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.02”
Context: 17.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · copperGrade: 0.56Grade Unit: %Intercept: 11.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.56
- Grade Unit
- %
- Intercept
- 11.7 m
- From
- 885.8 m
- To
- 897.5 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:885.8-897.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a weak copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Weak copper grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“0.56”
Context: 11.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · zincGrade: 3.49Grade Unit: %Intercept: 11.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.49
- Grade Unit
- %
- Intercept
- 11.7 m
- From
- 885.8 m
- To
- 897.5 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:885.8-897.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.49
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept shows a moderate ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Moderate ZnEq grade for VMS deposit type
- Polymetallic nature of the mineralization
Negative factors
- Apparent width only
Evidence · table
“3.49”
Context: 11.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · goldGrade: 0.47Grade Unit: g/tIntercept: 11.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.47
- Grade Unit
- g/t
- Intercept
- 11.7 m
- From
- 885.8 m
- To
- 897.5 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:885.8-897.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.47”
Context: 11.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · silverGrade: 7.4Grade Unit: g/tIntercept: 11.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 7.4
- Grade Unit
- g/t
- Intercept
- 11.7 m
- From
- 885.8 m
- To
- 897.5 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:885.8-897.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“7.4”
Context: 11.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-103BWagosic · leadGrade: 0.01Grade Unit: %Intercept: 11.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-103B
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 11.7 m
- From
- 885.8 m
- To
- 897.5 m
- Intercept Depth
- 532.9 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-103B:885.8-897.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This intercept has very low lead grade. Only apparent width is provided.
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.01”
Context: 11.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · copperGrade: 0.03Grade Unit: %Intercept: 354 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 354 m
- From
- 572 m
- To
- 926 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-926
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low copper grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low copper grade for VMS deposit type
- Apparent width only
Evidence · table
“0.03”
Context: 354.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · zincGrade: 0.82Grade Unit: %Intercept: 354 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.82
- Grade Unit
- %
- Intercept
- 354 m
- From
- 572 m
- To
- 926 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-926
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % ZnEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a weak ZnEq grade for a VMS deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- ZnEq grade is weak for VMS deposit type
- Apparent width only
Evidence · table
“0.82”
Context: 354.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · goldGrade: 0.02Grade Unit: g/tIntercept: 354 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 354 m
- From
- 572 m
- To
- 926 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-926
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low gold grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low gold grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“0.02”
Context: 354.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · silverGrade: 6Grade Unit: g/tIntercept: 354 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 6
- Grade Unit
- g/t
- Intercept
- 354 m
- From
- 572 m
- To
- 926 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-926
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low silver grade for a VMS-epithermal deposit. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low silver grade for VMS-epithermal deposit type
- Apparent width only
Evidence · table
“6.0”
Context: 354.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · leadGrade: 0.02Grade Unit: %Intercept: 354 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 354 m
- From
- 572 m
- To
- 926 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-926
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: This is a very long intercept with a very low lead grade. Only apparent width is provided.
Positive factors
- Very long intercept length
- Polymetallic nature of the mineralization
Negative factors
- Very low lead grade
- Apparent width only
Evidence · table
“0.02”
Context: 354.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-105Wagosic · copperGrade: 0Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- 1338-26-105
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- 1338-26-105:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Positive factors
- Polymetallic nature of the mineralization
Negative factors
- No copper grade reported
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.03Grade Unit: %Intercept: 106.75 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.2 %·m is below.
Negative factors
- 0.03 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 0.92Grade Unit: %Intercept: 106.75 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.92
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.92 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 98.2 %·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.92”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.06Grade Unit: g/tIntercept: 106.75 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 6.4 g/t·m is below.
Negative factors
- 0.06 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 80.5Grade Unit: g/tIntercept: 106.75 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 80.5
- Grade Unit
- g/t
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 80.5 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 8593.4 g/t·m is exceptional (grade alone is weak; the better of the two is used).
Positive factors
- 80.5 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“80.5”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.08Grade Unit: %Intercept: 106.75 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 106.75 m
- From
- 857.25 m
- To
- 964 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:857.25-964
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.81
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 8.5 %·m is below.
Negative factors
- 0.08 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · copperGrade: 0.03Grade Unit: %Intercept: 21.75 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.7 %·m is below.
Negative factors
- 0.03 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · zincGrade: 0.73Grade Unit: %Intercept: 21.75 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.73
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.73 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 15.9 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.73”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · goldGrade: 0.12Grade Unit: g/tIntercept: 21.75 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.12 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.6 g/t·m is below.
Negative factors
- 0.12 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.12”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · silverGrade: 334Grade Unit: g/tIntercept: 21.75 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 334
- Grade Unit
- g/t
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 334 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 7264.5 g/t·m is strong.
Positive factors
- 334 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“334.0”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · leadGrade: 0.15Grade Unit: %Intercept: 21.75 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 21.75 m
- From
- 857.25 m
- To
- 879 m
- Intercept Depth
- 857.25 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:857.25-879
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 12.04
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 3.3 %·m is below.
Negative factors
- 0.15 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.39Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 1017 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.39 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 44.9 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.39”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.14Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 1017 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.14 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 16.1 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.14”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.27Grade Unit: g/tIntercept: 115 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 1017 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 31.1 g/t·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 6.3Grade Unit: g/tIntercept: 115 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 6.3
- Grade Unit
- g/t
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 1017 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 6.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 724.5 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.3”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.01Grade Unit: %Intercept: 115 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 115 m
- From
- 1017 m
- To
- 1132 m
- Intercept Depth
- 1017 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1017-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.37
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.2 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · copperGrade: 1Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 1112 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 20.0 %·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.00”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · zincGrade: 0.05Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 1112 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.05 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · goldGrade: 0.57Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 1112 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.57 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 11.4 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.57”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · silverGrade: 13.9Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 13.9
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 1112 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 13.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 278.0 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.9”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · leadGrade: 0Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 20 m
- From
- 1112 m
- To
- 1132 m
- Intercept Depth
- 1112 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:1112-1132
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 0.16Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 5.3 %·m is below.
Negative factors
- 0.16 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.02Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 137.3Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 137.3
- Grade Unit
- g/t
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 137.3 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 4530.9 g/t·m is strong (grade alone is moderate; the better of the two is used).
Positive factors
- 137.3 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“137.3”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.03Grade Unit: %Intercept: 33 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 33 m
- From
- 415 m
- To
- 448 m
- Intercept Depth
- 415 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:415-448
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.03 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.04Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 617 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.5 %·m is below.
Negative factors
- 0.04 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 2.34Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 2.34
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 617 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 2.34 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 29.3 %·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.34”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.15Grade Unit: g/tIntercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 617 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.9 g/t·m is below.
Negative factors
- 0.15 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 19.5Grade Unit: g/tIntercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 19.5
- Grade Unit
- g/t
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 617 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 19.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 243.8 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“19.5”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.01Grade Unit: %Intercept: 12.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 12.5 m
- From
- 617 m
- To
- 629.5 m
- Intercept Depth
- 617 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:617-629.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.02Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.4 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 1.95Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.95
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.95 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 34.7 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.95”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.4 g/t·m is below.
Negative factors
- 0.08 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 34.5Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 34.5
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 34.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 614.1 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“34.5”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.1Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 630.5 m
- To
- 648.3 m
- Intercept Depth
- 630.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:630.5-648.3
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.36
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.8 %·m is below.
Negative factors
- 0.1 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.01Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 756 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 1.69Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 756 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.69 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 27.0 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.69”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.44Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 756 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.44 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 7.0 g/t·m is below.
Negative factors
- 0.44 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.44”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 10.4Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 10.4
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 756 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 10.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 166.4 g/t·m is below.
Negative factors
- 10.4 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.4”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.08Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 16 m
- From
- 756 m
- To
- 772 m
- Intercept Depth
- 756 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:756-772
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.25
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.3 %·m is below.
Negative factors
- 0.08 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.93Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.93
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 904 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.93 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 12.1 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.93”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.59Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 904 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.59 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 7.7 %·m is below.
Negative factors
- 0.59 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.59”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.26Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 904 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.26 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3.4 g/t·m is below.
Negative factors
- 0.26 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.26”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 34.2Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 34.2
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 904 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 34.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 444.6 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“34.2”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.04Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 13 m
- From
- 904 m
- To
- 917 m
- Intercept Depth
- 904 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:904-917
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.51
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.5 %·m is below.
Negative factors
- 0.04 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 519 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 1.69Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 519 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.69 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 29.6 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.69”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 519 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.4 g/t·m is below.
Negative factors
- 0.08 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 32.4Grade Unit: g/tIntercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 32.4
- Grade Unit
- g/t
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 519 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 32.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 567.0 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“32.4”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.44Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.44
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 519 m
- To
- 536.5 m
- Intercept Depth
- 519 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:519-536.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.44 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 7.7 %·m is below.
Negative factors
- 0.44 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.44”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.77Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.77
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 642 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.77 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 80.9 %·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.77”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 3Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 642 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 315.0 %·m is exceptional (grade alone is weak; the better of the two is used).
Positive factors
- 3 % zinc is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.00”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.1Grade Unit: g/tIntercept: 105 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 642 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.5 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 36.6Grade Unit: g/tIntercept: 105 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 36.6
- Grade Unit
- g/t
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 642 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 36.6 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 3843.0 g/t·m is strong (grade alone is weak; the better of the two is used).
Positive factors
- 36.6 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“36.6”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.04Grade Unit: %Intercept: 105 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 105 m
- From
- 642 m
- To
- 747 m
- Intercept Depth
- 642 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:642-747
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 7.03
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 4.2 %·m is below.
Negative factors
- 0.04 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · copperGrade: 1.96Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.96
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 700 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.96 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 77.8 %·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 1.96 % copper is strong on the vms deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.96”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · zincGrade: 3.78Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.78
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 700 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3.78 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 150.1 %·m is strong (grade alone is weak; the better of the two is used).
Positive factors
- 3.78 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.78”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · goldGrade: 0.18Grade Unit: g/tIntercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 700 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 7.1 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · silverGrade: 67.5Grade Unit: g/tIntercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 67.5
- Grade Unit
- g/t
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 700 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 67.5 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 2679.8 g/t·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“67.5”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · leadGrade: 0.03Grade Unit: %Intercept: 39.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 39.7 m
- From
- 700 m
- To
- 739.7 m
- Intercept Depth
- 700 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:700-739.7
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 13
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.2 %·m is below.
Negative factors
- 0.03 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 1.02Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 773 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.02 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 18.3 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.02”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.85Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.85
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 773 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.85 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 15.2 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.85”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.23Grade Unit: g/tIntercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 773 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.23 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.1 g/t·m is below.
Negative factors
- 0.23 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.23”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 46.2Grade Unit: g/tIntercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 46.2
- Grade Unit
- g/t
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 773 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 46.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 827.0 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“46.2”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.02Grade Unit: %Intercept: 17.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 17.9 m
- From
- 773 m
- To
- 790.9 m
- Intercept Depth
- 773 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:773-790.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.38
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below.
Negative factors
- 0.02 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 1.48Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.48
- Grade Unit
- %
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.48 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 25.2 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.48”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.01Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.01 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 14.8Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 14.8
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 14.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 251.6 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14.8”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.08Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 17 m
- From
- 572 m
- To
- 589 m
- Intercept Depth
- 572 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:572-589
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.4 %·m is below.
Negative factors
- 0.08 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.07Grade Unit: %Intercept: 69.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 69.5 m
- From
- 819.5 m
- To
- 889 m
- Intercept Depth
- 819.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:819.5-889
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 4.9 %·m is below.
Negative factors
- 0.07 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 1.17Grade Unit: %Intercept: 69.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.17
- Grade Unit
- %
- Intercept
- 69.5 m
- From
- 819.5 m
- To
- 889 m
- Intercept Depth
- 819.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:819.5-889
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.17 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 81.3 %·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.17”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.04Grade Unit: g/tIntercept: 69.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 69.5 m
- From
- 819.5 m
- To
- 889 m
- Intercept Depth
- 819.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:819.5-889
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.8 g/t·m is below.
Negative factors
- 0.04 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 6.3Grade Unit: g/tIntercept: 69.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 6.3
- Grade Unit
- g/t
- Intercept
- 69.5 m
- From
- 819.5 m
- To
- 889 m
- Intercept Depth
- 819.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:819.5-889
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 6.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 437.8 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.3”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.01Grade Unit: %Intercept: 69.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 69.5 m
- From
- 819.5 m
- To
- 889 m
- Intercept Depth
- 819.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:819.5-889
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.72
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.7 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-108Wagosic · copperGrade: 0.13Grade Unit: %Intercept: 285.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-108
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 285.9 m
- From
- 913 m
- To
- 1198.9 m
- Intercept Depth
- 913 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-108:913-1198.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 37.2 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: 1338-26-108
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-108Wagosic · zincGrade: 0.19Grade Unit: %Intercept: 285.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-108
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 285.9 m
- From
- 913 m
- To
- 1198.9 m
- Intercept Depth
- 913 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-108:913-1198.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.19 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 54.3 %·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.19”
Context: 1338-26-108
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-108Wagosic · goldGrade: 0.09Grade Unit: g/tIntercept: 285.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-108
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 285.9 m
- From
- 913 m
- To
- 1198.9 m
- Intercept Depth
- 913 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-108:913-1198.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 25.7 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: 1338-26-108
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-108Wagosic · silverGrade: 3.8Grade Unit: g/tIntercept: 285.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-108
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.8
- Grade Unit
- g/t
- Intercept
- 285.9 m
- From
- 913 m
- To
- 1198.9 m
- Intercept Depth
- 913 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-108:913-1198.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3.8 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1086.4 g/t·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.8”
Context: 1338-26-108
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-108Wagosic · leadGrade: 0.01Grade Unit: %Intercept: 285.9 mView all detailsHide details
Identity
- Hole ID
- 1338-26-108
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 285.9 m
- From
- 913 m
- To
- 1198.9 m
- Intercept Depth
- 913 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-108:913-1198.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.99
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.9 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: 1338-26-108
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.22Grade Unit: %Intercept: 32.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.22
- Grade Unit
- %
- Intercept
- 32.8 m
- From
- 988.7 m
- To
- 1021.5 m
- Intercept Depth
- 988.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:988.7-1021.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.65
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 7.2 %·m is below.
Negative factors
- 0.22 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.22”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 0.32Grade Unit: %Intercept: 32.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 32.8 m
- From
- 988.7 m
- To
- 1021.5 m
- Intercept Depth
- 988.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:988.7-1021.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.65
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.32 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 10.5 %·m is below.
Negative factors
- 0.32 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.32”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.18Grade Unit: g/tIntercept: 32.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 32.8 m
- From
- 988.7 m
- To
- 1021.5 m
- Intercept Depth
- 988.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:988.7-1021.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.65
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.9 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 3.4Grade Unit: g/tIntercept: 32.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.4
- Grade Unit
- g/t
- Intercept
- 32.8 m
- From
- 988.7 m
- To
- 1021.5 m
- Intercept Depth
- 988.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:988.7-1021.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.65
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 111.5 g/t·m is below.
Negative factors
- 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.4”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0Grade Unit: %Intercept: 32.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 32.8 m
- From
- 988.7 m
- To
- 1021.5 m
- Intercept Depth
- 988.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:988.7-1021.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.65
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.48Grade Unit: %Intercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.48
- Grade Unit
- %
- Intercept
- 20.5 m
- From
- 1121.5 m
- To
- 1142 m
- Intercept Depth
- 1121.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1121.5-1142
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.48 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 9.8 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.48”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.05Grade Unit: %Intercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 20.5 m
- From
- 1121.5 m
- To
- 1142 m
- Intercept Depth
- 1121.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1121.5-1142
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.05 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.17Grade Unit: g/tIntercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 20.5 m
- From
- 1121.5 m
- To
- 1142 m
- Intercept Depth
- 1121.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1121.5-1142
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.17 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3.5 g/t·m is below.
Negative factors
- 0.17 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.17”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 12.7Grade Unit: g/tIntercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 12.7
- Grade Unit
- g/t
- Intercept
- 20.5 m
- From
- 1121.5 m
- To
- 1142 m
- Intercept Depth
- 1121.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1121.5-1142
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 12.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 260.3 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“12.7”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.01Grade Unit: %Intercept: 20.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 20.5 m
- From
- 1121.5 m
- To
- 1142 m
- Intercept Depth
- 1121.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1121.5-1142
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.52
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 3.18Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.18
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 1182.9 m
- To
- 1184.8 m
- Intercept Depth
- 1182.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1182.9-1184.8
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3.18 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 6.0 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 3.18 % copper is exceptional on the vms deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.18”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 1Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 1182.9 m
- To
- 1184.8 m
- Intercept Depth
- 1182.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1182.9-1184.8
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.9 %·m is below.
Negative factors
- 1 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.00”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.53Grade Unit: g/tIntercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1.9 m
- From
- 1182.9 m
- To
- 1184.8 m
- Intercept Depth
- 1182.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1182.9-1184.8
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.0 g/t·m is below.
Negative factors
- 0.53 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 67Grade Unit: g/tIntercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 67
- Grade Unit
- g/t
- Intercept
- 1.9 m
- From
- 1182.9 m
- To
- 1184.8 m
- Intercept Depth
- 1182.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1182.9-1184.8
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 67 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 127.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“67.0”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.01Grade Unit: %Intercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1.9 m
- From
- 1182.9 m
- To
- 1184.8 m
- Intercept Depth
- 1182.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:1182.9-1184.8
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-110CWagosic · copperGrade: 0.05Grade Unit: %Intercept: 319.55 mView all detailsHide details
Identity
- Hole ID
- 1338-26-110C
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 319.55 m
- From
- 476.45 m
- To
- 796 m
- Intercept Depth
- 476.45 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-110C:476.45-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 16.0 %·m is below.
Negative factors
- 0.05 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: 1338-26-110C
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-110CWagosic · zincGrade: 1.19Grade Unit: %Intercept: 319.55 mView all detailsHide details
Identity
- Hole ID
- 1338-26-110C
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.19
- Grade Unit
- %
- Intercept
- 319.55 m
- From
- 476.45 m
- To
- 796 m
- Intercept Depth
- 476.45 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-110C:476.45-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.19 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 380.3 %·m is exceptional (grade alone is below; the better of the two is used).
Positive factors
- 1.19 % zinc is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.19”
Context: 1338-26-110C
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-110CWagosic · goldGrade: 0.05Grade Unit: g/tIntercept: 319.55 mView all detailsHide details
Identity
- Hole ID
- 1338-26-110C
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 319.55 m
- From
- 476.45 m
- To
- 796 m
- Intercept Depth
- 476.45 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-110C:476.45-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 16.0 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: 1338-26-110C
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-110CWagosic · silverGrade: 22.3Grade Unit: g/tIntercept: 319.55 mView all detailsHide details
Identity
- Hole ID
- 1338-26-110C
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 22.3
- Grade Unit
- g/t
- Intercept
- 319.55 m
- From
- 476.45 m
- To
- 796 m
- Intercept Depth
- 476.45 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-110C:476.45-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 22.3 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 7126.0 g/t·m is strong (grade alone is below; the better of the two is used).
Positive factors
- 22.3 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“22.3”
Context: 1338-26-110C
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-110CWagosic · leadGrade: 0.06Grade Unit: %Intercept: 319.55 mView all detailsHide details
Identity
- Hole ID
- 1338-26-110C
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 319.55 m
- From
- 476.45 m
- To
- 796 m
- Intercept Depth
- 476.45 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-110C:476.45-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.22
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 19.2 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: 1338-26-110C
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.05Grade Unit: %Intercept: 136.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 136.8 m
- From
- 479.2 m
- To
- 616 m
- Intercept Depth
- 479.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:479.2-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.88
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 6.8 %·m is below.
Negative factors
- 0.05 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 2.09Grade Unit: %Intercept: 136.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 2.09
- Grade Unit
- %
- Intercept
- 136.8 m
- From
- 479.2 m
- To
- 616 m
- Intercept Depth
- 479.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:479.2-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.88
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 2.09 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 285.9 %·m is exceptional (grade alone is weak; the better of the two is used).
Positive factors
- 2.09 % zinc is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.09”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.02Grade Unit: g/tIntercept: 136.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 136.8 m
- From
- 479.2 m
- To
- 616 m
- Intercept Depth
- 479.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:479.2-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.88
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 48.2Grade Unit: g/tIntercept: 136.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 48.2
- Grade Unit
- g/t
- Intercept
- 136.8 m
- From
- 479.2 m
- To
- 616 m
- Intercept Depth
- 479.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:479.2-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.88
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 48.2 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 6593.8 g/t·m is strong (grade alone is weak; the better of the two is used).
Positive factors
- 48.2 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“48.2”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.14Grade Unit: %Intercept: 136.8 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 136.8 m
- From
- 479.2 m
- To
- 616 m
- Intercept Depth
- 479.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:479.2-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.88
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.14 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 19.2 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.14”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · copperGrade: 0.14Grade Unit: %Intercept: 21 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 21 m
- From
- 489 m
- To
- 510 m
- Intercept Depth
- 489 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:489-510
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.5
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.9 %·m is below.
Negative factors
- 0.14 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.14”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · zincGrade: 3.14Grade Unit: %Intercept: 21 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 3.14
- Grade Unit
- %
- Intercept
- 21 m
- From
- 489 m
- To
- 510 m
- Intercept Depth
- 489 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:489-510
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.5
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 3.14 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 65.9 %·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.14”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · goldGrade: 0Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 21 m
- From
- 489 m
- To
- 510 m
- Intercept Depth
- 489 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:489-510
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.5
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · silverGrade: 180.7Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 180.7
- Grade Unit
- g/t
- Intercept
- 21 m
- From
- 489 m
- To
- 510 m
- Intercept Depth
- 489 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:489-510
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.5
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 180.7 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 3794.7 g/t·m is strong (grade alone is moderate; the better of the two is used).
Positive factors
- 180.7 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“180.7”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Wagosic · leadGrade: 0.26Grade Unit: %Intercept: 21 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 21 m
- From
- 489 m
- To
- 510 m
- Intercept Depth
- 489 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- incl.:489-510
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.5
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.26 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 5.5 %·m is below.
Negative factors
- 0.26 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.26”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andWagosic · copperGrade: 0.17Grade Unit: %Intercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 9.35 m
- From
- 606.65 m
- To
- 616 m
- Intercept Depth
- 606.65 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:606.65-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.07
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.6 %·m is below.
Negative factors
- 0.17 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.17”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andWagosic · zincGrade: 10.62Grade Unit: %Intercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 10.62
- Grade Unit
- %
- Intercept
- 9.35 m
- From
- 606.65 m
- To
- 616 m
- Intercept Depth
- 606.65 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:606.65-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.07
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 10.62 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 99.3 %·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 10.62 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.62”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andWagosic · goldGrade: 0.17Grade Unit: g/tIntercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 9.35 m
- From
- 606.65 m
- To
- 616 m
- Intercept Depth
- 606.65 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:606.65-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.07
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.17 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.6 g/t·m is below.
Negative factors
- 0.17 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.17”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andWagosic · silverGrade: 74.4Grade Unit: g/tIntercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 74.4
- Grade Unit
- g/t
- Intercept
- 9.35 m
- From
- 606.65 m
- To
- 616 m
- Intercept Depth
- 606.65 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:606.65-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.07
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 74.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 695.6 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“74.4”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andWagosic · leadGrade: 0.68Grade Unit: %Intercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 9.35 m
- From
- 606.65 m
- To
- 616 m
- Intercept Depth
- 606.65 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:606.65-616
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.07
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.68 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 6.4 %·m is below.
Negative factors
- 0.68 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.68”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.27Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 13 m
- From
- 783 m
- To
- 796 m
- Intercept Depth
- 783 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:783-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.7
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.5 %·m is below.
Negative factors
- 0.27 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.52Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.52
- Grade Unit
- %
- Intercept
- 13 m
- From
- 783 m
- To
- 796 m
- Intercept Depth
- 783 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:783-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.7
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.52 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 6.8 %·m is below.
Negative factors
- 0.52 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.52”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.39Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 783 m
- To
- 796 m
- Intercept Depth
- 783 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:783-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.7
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.39 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.1 g/t·m is below.
Negative factors
- 0.39 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.39”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 7.1Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 7.1
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 783 m
- To
- 796 m
- Intercept Depth
- 783 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:783-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.7
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 7.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 92.3 g/t·m is below.
Negative factors
- 7.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.1”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.02Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 13 m
- From
- 783 m
- To
- 796 m
- Intercept Depth
- 783 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:783-796
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.7
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.02 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-114Wagosic · copperGrade: 0.03Grade Unit: %Intercept: 296 mView all detailsHide details
Identity
- Hole ID
- 1338-26-114
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 296 m
- From
- 660 m
- To
- 956 m
- Intercept Depth
- 660 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-114:660-956
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.78
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 8.9 %·m is below.
Negative factors
- 0.03 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: 1338-26-114
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-114Wagosic · zincGrade: 0.47Grade Unit: %Intercept: 296 mView all detailsHide details
Identity
- Hole ID
- 1338-26-114
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.47
- Grade Unit
- %
- Intercept
- 296 m
- From
- 660 m
- To
- 956 m
- Intercept Depth
- 660 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-114:660-956
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.78
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.47 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 139.1 %·m is strong (grade alone is below; the better of the two is used).
Positive factors
- 0.47 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.47”
Context: 1338-26-114
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-114Wagosic · goldGrade: 0.02Grade Unit: g/tIntercept: 296 mView all detailsHide details
Identity
- Hole ID
- 1338-26-114
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 296 m
- From
- 660 m
- To
- 956 m
- Intercept Depth
- 660 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-114:660-956
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.78
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.9 g/t·m is below.
Negative factors
- 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: 1338-26-114
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-114Wagosic · silverGrade: 4.9Grade Unit: g/tIntercept: 296 mView all detailsHide details
Identity
- Hole ID
- 1338-26-114
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 4.9
- Grade Unit
- g/t
- Intercept
- 296 m
- From
- 660 m
- To
- 956 m
- Intercept Depth
- 660 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-114:660-956
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.78
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 4.9 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1450.4 g/t·m is moderate (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.9”
Context: 1338-26-114
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-114Wagosic · leadGrade: 0.01Grade Unit: %Intercept: 296 mView all detailsHide details
Identity
- Hole ID
- 1338-26-114
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 296 m
- From
- 660 m
- To
- 956 m
- Intercept Depth
- 660 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-114:660-956
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.78
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 3.0 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: 1338-26-114
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.47Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.47
- Grade Unit
- %
- Intercept
- 10 m
- From
- 789.5 m
- To
- 799.5 m
- Intercept Depth
- 789.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:789.5-799.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.41
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.47 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 4.7 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.47”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 2.53Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 2.53
- Grade Unit
- %
- Intercept
- 10 m
- From
- 789.5 m
- To
- 799.5 m
- Intercept Depth
- 789.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:789.5-799.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.41
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 2.53 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 25.3 %·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.53”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.2Grade Unit: g/tIntercept: 10 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 10 m
- From
- 789.5 m
- To
- 799.5 m
- Intercept Depth
- 789.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:789.5-799.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.41
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.0 g/t·m is below.
Negative factors
- 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.20”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 54.5Grade Unit: g/tIntercept: 10 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 54.5
- Grade Unit
- g/t
- Intercept
- 10 m
- From
- 789.5 m
- To
- 799.5 m
- Intercept Depth
- 789.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:789.5-799.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.41
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 54.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 545.0 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“54.5”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.04Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 10 m
- From
- 789.5 m
- To
- 799.5 m
- Intercept Depth
- 789.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:789.5-799.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.41
- Metal Eq. Unit
- % Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below.
Negative factors
- 0.04 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-100Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- 1338-26-100
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 54.8 m
- From
- 375.3 m
- To
- 430.1 m
- Intercept Depth
- 375.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-100:375.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 184.2
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.5 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: 1338-26-100
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-100Wagosic · zincGrade: 0.32Grade Unit: %Intercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- 1338-26-100
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 54.8 m
- From
- 375.3 m
- To
- 430.1 m
- Intercept Depth
- 375.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-100:375.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 184.2
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.32 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 17.5 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.32”
Context: 1338-26-100
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-100Wagosic · goldGrade: 0.07Grade Unit: g/tIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- 1338-26-100
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 54.8 m
- From
- 375.3 m
- To
- 430.1 m
- Intercept Depth
- 375.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-100:375.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 184.2
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3.8 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: 1338-26-100
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-100Wagosic · silverGrade: 167.6Grade Unit: g/tIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- 1338-26-100
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 167.6
- Grade Unit
- g/t
- Intercept
- 54.8 m
- From
- 375.3 m
- To
- 430.1 m
- Intercept Depth
- 375.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-100:375.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 184.2
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 167.6 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 9184.5 g/t·m is exceptional (grade alone is moderate; the better of the two is used).
Positive factors
- 167.6 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“167.6”
Context: 1338-26-100
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-100Wagosic · leadGrade: 0.17Grade Unit: %Intercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- 1338-26-100
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 54.8 m
- From
- 375.3 m
- To
- 430.1 m
- Intercept Depth
- 375.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-100:375.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 184.2
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.17 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 9.3 %·m is below.
Negative factors
- 0.17 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.17”
Context: 1338-26-100
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 382.9 m
- To
- 387.5 m
- Intercept Depth
- 382.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:382.9-387.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 820.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 0.71Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.71
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 382.9 m
- To
- 387.5 m
- Intercept Depth
- 382.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:382.9-387.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 820.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.71 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 3.3 %·m is below.
Negative factors
- 0.71 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.71”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.28Grade Unit: g/tIntercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 4.6 m
- From
- 382.9 m
- To
- 387.5 m
- Intercept Depth
- 382.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:382.9-387.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 820.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.28 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.3 g/t·m is below.
Negative factors
- 0.28 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.28”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 774.1Grade Unit: g/tIntercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 774.1
- Grade Unit
- g/t
- Intercept
- 4.6 m
- From
- 382.9 m
- To
- 387.5 m
- Intercept Depth
- 382.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:382.9-387.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 820.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 774.1 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 3560.9 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 774.1 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“774.1”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.45Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 382.9 m
- To
- 387.5 m
- Intercept Depth
- 382.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:382.9-387.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 820.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.45 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.1 %·m is below.
Negative factors
- 0.45 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.45”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.01Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 412.3 m
- To
- 430.1 m
- Intercept Depth
- 412.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:412.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 209.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.16Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 412.3 m
- To
- 430.1 m
- Intercept Depth
- 412.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:412.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 209.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.8 %·m is below.
Negative factors
- 0.16 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 412.3 m
- To
- 430.1 m
- Intercept Depth
- 412.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:412.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 209.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.4 g/t·m is below.
Negative factors
- 0.08 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 196.5Grade Unit: g/tIntercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 196.5
- Grade Unit
- g/t
- Intercept
- 17.8 m
- From
- 412.3 m
- To
- 430.1 m
- Intercept Depth
- 412.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:412.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 209.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 196.5 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 3497.7 g/t·m is strong (grade alone is moderate; the better of the two is used).
Positive factors
- 196.5 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“196.5”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.08Grade Unit: %Intercept: 17.8 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 17.8 m
- From
- 412.3 m
- To
- 430.1 m
- Intercept Depth
- 412.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:412.3-430.1
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 209.1
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.4 %·m is below.
Negative factors
- 0.08 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-102Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 37.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-102
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 37.7 m
- From
- 345.3 m
- To
- 383 m
- Intercept Depth
- 345.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-102:345.3-383
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 91.4
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.4 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: 1338-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-102Wagosic · zincGrade: 0.49Grade Unit: %Intercept: 37.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-102
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.49
- Grade Unit
- %
- Intercept
- 37.7 m
- From
- 345.3 m
- To
- 383 m
- Intercept Depth
- 345.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-102:345.3-383
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 91.4
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.49 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 18.5 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.49”
Context: 1338-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-102Wagosic · goldGrade: 0.08Grade Unit: g/tIntercept: 37.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-102
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 37.7 m
- From
- 345.3 m
- To
- 383 m
- Intercept Depth
- 345.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-102:345.3-383
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 91.4
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3.0 g/t·m is below.
Negative factors
- 0.08 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: 1338-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-102Wagosic · silverGrade: 68.7Grade Unit: g/tIntercept: 37.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-102
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 68.7
- Grade Unit
- g/t
- Intercept
- 37.7 m
- From
- 345.3 m
- To
- 383 m
- Intercept Depth
- 345.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-102:345.3-383
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 91.4
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 68.7 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 2590.0 g/t·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“68.7”
Context: 1338-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-102Wagosic · leadGrade: 0.21Grade Unit: %Intercept: 37.7 mView all detailsHide details
Identity
- Hole ID
- 1338-26-102
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.21
- Grade Unit
- %
- Intercept
- 37.7 m
- From
- 345.3 m
- To
- 383 m
- Intercept Depth
- 345.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-102:345.3-383
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 91.4
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 7.9 %·m is below.
Negative factors
- 0.21 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: 1338-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.02Grade Unit: %Intercept: 6.9 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 6.9 m
- From
- 355 m
- To
- 361.9 m
- Intercept Depth
- 355 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:355-361.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 271.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 1.45Grade Unit: %Intercept: 6.9 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 1.45
- Grade Unit
- %
- Intercept
- 6.9 m
- From
- 355 m
- To
- 361.9 m
- Intercept Depth
- 355 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:355-361.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 271.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 1.45 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 10.0 %·m is below.
Negative factors
- 1.45 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.45”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.1Grade Unit: g/tIntercept: 6.9 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 6.9 m
- From
- 355 m
- To
- 361.9 m
- Intercept Depth
- 355 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:355-361.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 271.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 217.1Grade Unit: g/tIntercept: 6.9 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 217.1
- Grade Unit
- g/t
- Intercept
- 6.9 m
- From
- 355 m
- To
- 361.9 m
- Intercept Depth
- 355 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:355-361.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 271.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 217.1 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 1498.0 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 217.1 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“217.1”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.75Grade Unit: %Intercept: 6.9 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.75
- Grade Unit
- %
- Intercept
- 6.9 m
- From
- 355 m
- To
- 361.9 m
- Intercept Depth
- 355 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:355-361.9
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 271.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.75 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 5.2 %·m is below.
Negative factors
- 0.75 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.75”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-104Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 96.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-104
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 96.5 m
- From
- 256 m
- To
- 352.5 m
- Intercept Depth
- 256 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-104:256-352.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 83.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: 1338-26-104
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-104Wagosic · zincGrade: 0.37Grade Unit: %Intercept: 96.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-104
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 96.5 m
- From
- 256 m
- To
- 352.5 m
- Intercept Depth
- 256 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-104:256-352.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 83.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.37 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 35.7 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.37”
Context: 1338-26-104
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-104Wagosic · goldGrade: 0.06Grade Unit: g/tIntercept: 96.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-104
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 96.5 m
- From
- 256 m
- To
- 352.5 m
- Intercept Depth
- 256 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-104:256-352.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 83.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.8 g/t·m is below.
Negative factors
- 0.06 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: 1338-26-104
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-104Wagosic · silverGrade: 66.6Grade Unit: g/tIntercept: 96.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-104
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 66.6
- Grade Unit
- g/t
- Intercept
- 96.5 m
- From
- 256 m
- To
- 352.5 m
- Intercept Depth
- 256 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-104:256-352.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 83.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 66.6 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 6426.9 g/t·m is strong (grade alone is weak; the better of the two is used).
Positive factors
- 66.6 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“66.6”
Context: 1338-26-104
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-104Wagosic · leadGrade: 0.11Grade Unit: %Intercept: 96.5 mView all detailsHide details
Identity
- Hole ID
- 1338-26-104
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 96.5 m
- From
- 256 m
- To
- 352.5 m
- Intercept Depth
- 256 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-104:256-352.5
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 83.9
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 10.6 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: 1338-26-104
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · copperGrade: 0.01Grade Unit: %Intercept: 6.3 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 6.3 m
- From
- 258.7 m
- To
- 265 m
- Intercept Depth
- 258.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:258.7-265
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 301.5
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · zincGrade: 0.36Grade Unit: %Intercept: 6.3 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 6.3 m
- From
- 258.7 m
- To
- 265 m
- Intercept Depth
- 258.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:258.7-265
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 301.5
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.36 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.3 %·m is below.
Negative factors
- 0.36 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.36”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · goldGrade: 0.21Grade Unit: g/tIntercept: 6.3 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 6.3 m
- From
- 258.7 m
- To
- 265 m
- Intercept Depth
- 258.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:258.7-265
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 301.5
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.3 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · silverGrade: 272Grade Unit: g/tIntercept: 6.3 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 272
- Grade Unit
- g/t
- Intercept
- 6.3 m
- From
- 258.7 m
- To
- 265 m
- Intercept Depth
- 258.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:258.7-265
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 301.5
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 272 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 1713.6 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 272 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“272.0”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Incl.Wagosic · leadGrade: 0.16Grade Unit: %Intercept: 6.3 mView all detailsHide details
Identity
- Hole ID
- Incl.
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 6.3 m
- From
- 258.7 m
- To
- 265 m
- Intercept Depth
- 258.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- Incl.:258.7-265
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 301.5
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.16 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: Incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · copperGrade: 0.02Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 28 m
- From
- 283 m
- To
- 311 m
- Intercept Depth
- 283 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:283-311
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 116.3
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.6 %·m is below.
Negative factors
- 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · zincGrade: 0.7Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 28 m
- From
- 283 m
- To
- 311 m
- Intercept Depth
- 283 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:283-311
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 116.3
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.7 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 19.6 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.70”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · goldGrade: 0.07Grade Unit: g/tIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 28 m
- From
- 283 m
- To
- 311 m
- Intercept Depth
- 283 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:283-311
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 116.3
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.0 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · silverGrade: 87Grade Unit: g/tIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 87
- Grade Unit
- g/t
- Intercept
- 28 m
- From
- 283 m
- To
- 311 m
- Intercept Depth
- 283 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:283-311
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 116.3
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 87 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 2436.0 g/t·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“87.0”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AndWagosic · leadGrade: 0.2Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 28 m
- From
- 283 m
- To
- 311 m
- Intercept Depth
- 283 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- And:283-311
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 116.3
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 5.6 %·m is below.
Negative factors
- 0.2 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.20”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-112Wagosic · copperGrade: 0Grade Unit: %Intercept: 11 mView all detailsHide details
Identity
- Hole ID
- 1338-26-112
- Project
- Wagosic
- Commodity
- copper
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 11 m
- From
- 354 m
- To
- 365 m
- Intercept Depth
- 354 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-112:354-365
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 60.7
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: 1338-26-112
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-112Wagosic · zincGrade: 0.1Grade Unit: %Intercept: 11 mView all detailsHide details
Identity
- Hole ID
- 1338-26-112
- Project
- Wagosic
- Commodity
- zinc
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 11 m
- From
- 354 m
- To
- 365 m
- Intercept Depth
- 354 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-112:354-365
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 60.7
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.1 %·m is below.
Negative factors
- 0.1 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: 1338-26-112
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-112Wagosic · goldGrade: 0.06Grade Unit: g/tIntercept: 11 mView all detailsHide details
Identity
- Hole ID
- 1338-26-112
- Project
- Wagosic
- Commodity
- gold
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 11 m
- From
- 354 m
- To
- 365 m
- Intercept Depth
- 354 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-112:354-365
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 60.7
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.06 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: 1338-26-112
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-112Wagosic · silverGrade: 52.7Grade Unit: g/tIntercept: 11 mView all detailsHide details
Identity
- Hole ID
- 1338-26-112
- Project
- Wagosic
- Commodity
- silver
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 52.7
- Grade Unit
- g/t
- Intercept
- 11 m
- From
- 354 m
- To
- 365 m
- Intercept Depth
- 354 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-112:354-365
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 60.7
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 52.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 579.7 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“52.7”
Context: 1338-26-112
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
1338-26-112Wagosic · leadGrade: 0.02Grade Unit: %Intercept: 11 mView all detailsHide details
Identity
- Hole ID
- 1338-26-112
- Project
- Wagosic
- Commodity
- lead
- Region
- canada_qc
- Reported Region
- canada_qc
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 11 m
- From
- 354 m
- To
- 365 m
- Intercept Depth
- 354 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- 1338-26-112:354-365
- Mining Method
- underground
QA/QC
- Laboratory
- Activation Laboratories Ltd. (Actlabs)
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 60.7
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-15T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.02 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: 1338-26-112
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.