SLA: High Grade Gold Discovered at Myrnas Hill
Original announcement by asx on
- Company
- Solara Minerals Ltd
- Ticker
- SLA
- Exchange
- ASX
- Region
- Pilbara region of Western Australia
- Primary commodity
- Gold
- Secondary commodities
- Silver, Copper, Arsenic, Nickel
- Document categories
- Drill results, Other
- Extracted
- 2026-10-08 23:11:29 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Solara Minerals Ltd announced high-grade gold and silver results from reconnaissance rock chip sampling at its Myrnas Hill project in Western Australia, including 7.05 g/t Au and 3.28 g/t Ag. These new surface samples are encouraging for early-stage exploration and confirm the presence of a wide, traceable quartz vein system. The company also provided extensive historical drilling data, which generally shows lower-grade gold mineralization but provides valuable context for future exploration.
Reasoning: New high-grade gold and silver rock chip samples are encouraging for early-stage exploration at Myrnas Hill, supported by historical drilling confirming mineralization. However, the new results are selective surface samples, and historical data lacks modern QA/QC and true width reporting.
Positive factors
- High-grade gold and silver rock chip results (7.05 g/t Au, 3.28 g/t Ag) from reconnaissance sampling.
- Confirmation of gold mineralization along strike from historical drilling.
- QA/QC procedures disclosed for new samples, including use of ALS Laboratories and Competent Person sign-off.
- Identification of a wide, traceable quartz vein system.
Negative factors
- New results are from surface rock chip samples, which are selective and not representative of average grade over volume.
- Historical drill results are generally low-grade and lack modern QA/QC disclosure for specific assays.
- No true width reported for historical drill intercepts.
- Deleterious element (arsenic) present in historical drill results.
Facts used in scoring: 145
Extracted facts
Stored fact records: 145. Some facts used in scoring do not have a stored record.
Drill Results (145)
SLMH002Myrnas Hill · goldGrade: 7.05Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SLMH002
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 7.05
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Easting
- 765501
- Northing
- 7698127
- CRS
- GDA1994 MGA, Zone 50
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Exceptional gold grade from a new reconnaissance rock chip sample, indicating strong potential for follow-up.
Positive factors
- Bonanza Intercept
- High-grade gold result from reconnaissance sampling
Negative factors
- New results are from surface rock chip samples, which are selective
Evidence · text
“SLMH002: 7.05g/t Au and 3.28g/t Ag”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
SLMH002Myrnas Hill · silverGrade: 3.28Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SLMH002
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 3.28
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Easting
- 765501
- Northing
- 7698127
- CRS
- GDA1994 MGA, Zone 50
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Good silver grade from a new reconnaissance rock chip sample, adding to the prospectivity.
Positive factors
- High-grade silver result from reconnaissance sampling
Negative factors
- New results are from surface rock chip samples, which are selective
Evidence · text
“SLMH002: 7.05g/t Au and 3.28g/t Ag”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
SLMH007Myrnas Hill · goldGrade: 1.85Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SLMH007
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 1.85
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Easting
- 765868
- Northing
- 7698079
- CRS
- GDA1994 MGA, Zone 50
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Moderate gold grade from a new reconnaissance rock chip sample, extending mineralization along strike.
Positive factors
- Moderate-grade gold result from reconnaissance sampling
Negative factors
- New results are from surface rock chip samples, which are selective
Evidence · text
“SLMH007: 1.85g/t Au and 1.08g/t Ag”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
SLMH007Myrnas Hill · silverGrade: 1.08Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SLMH007
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Easting
- 765868
- Northing
- 7698079
- CRS
- GDA1994 MGA, Zone 50
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Low silver grade from a new reconnaissance rock chip sample.
Positive factors
- Silver result from reconnaissance sampling
Negative factors
- New results are from surface rock chip samples, which are selective
Evidence · text
“SLMH007: 1.85g/t Au and 1.08g/t Ag”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
FWM08Myrnas Hill · goldGrade: 1.51Grade Unit: g/tIntercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM08
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 1.51
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 19 m
- To
- 22 m
- Intercept Depth
- 19 m
Classification
- Sample Type
- drill
- Group ID
- FWM08:19-22
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Moderate historical gold intercept from RAB drilling, providing context for current exploration.
Positive factors
- Moderate-grade historical gold intercept
Negative factors
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“FWM08: 3m at 1.51g/t from 19m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM08Myrnas Hill · goldGrade: 2.93Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM08
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 2.93
- Grade Unit
- g/t
- Intercept
- 1 m
Classification
- Sample Type
- drill
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Strong historical gold sub-interval from RAB drilling, highlighting higher-grade zones.
Positive factors
- Strong-grade historical gold intercept
Negative factors
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“including 1m at 2.93g/t Au”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.2Grade Unit: g/tIntercept: 7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 7 m
- From
- 51 m
- To
- 58 m
- Intercept Depth
- 51 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:51-58
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Low-grade historical gold intercept from RAB drilling.
Negative factors
- Low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“FWM05: 7m at 0.20g/t Au from 51m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM09Myrnas Hill · goldGrade: 2.38Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM09
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 2.38
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 49 m
- To
- 50 m
- Intercept Depth
- 49 m
Classification
- Sample Type
- drill
- Group ID
- FWM09:49-50
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Strong historical gold intercept from RAB drilling, but over a narrow width.
Positive factors
- Strong-grade historical gold intercept
Negative factors
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“FWM09: 1m at 2.38g/t Au from 49m to EOH”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM31Myrnas Hill · goldGrade: 0.33Grade Unit: g/tIntercept: 12 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM31
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.33
- Grade Unit
- g/t
- Intercept
- 12 m
- From
- 28 m
- To
- 40 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM31:28-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2013-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Low-grade historical gold intercept from RC drilling.
Negative factors
- Low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“12m at 0.33g/t Au from 28m in FWM31”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM32Myrnas Hill · goldGrade: 1.02Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM32
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 68 m
- To
- 72 m
- Intercept Depth
- 68 m
Classification
- Sample Type
- drill
- Group ID
- FWM32:68-72
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2013-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Moderate historical gold intercept from RC drilling, located off-tenure.
Positive factors
- Moderate-grade historical gold intercept
Negative factors
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · text
“4m at 1.02g/t2 from 68m in FWM32”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 11Myrnas Hill · goldGrade: 6.7Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 6.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: High-grade historical gold rock chip, indicating strong surface mineralization.
Positive factors
- High-grade historical gold rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“6.70g/t Au, 8.98% Cu and 26.9g/t Ag (Kalamazoo, 2010)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 12Myrnas Hill · copperGrade: 8.98Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 8.98
- Grade Unit
- %
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: High-grade historical copper rock chip, indicating strong surface mineralization.
Positive factors
- High-grade historical copper rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“6.70g/t Au, 8.98% Cu and 26.9g/t Ag (Kalamazoo, 2010)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 13Myrnas Hill · silverGrade: 26.9Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 26.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Moderate-grade historical silver rock chip, indicating surface mineralization.
Positive factors
- Moderate-grade historical silver rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“6.70g/t Au, 8.98% Cu and 26.9g/t Ag (Kalamazoo, 2010)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 14Myrnas Hill · copperGrade: 7.1Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 7.1
- Grade Unit
- %
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2020-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: High-grade historical copper rock chip, indicating strong surface mineralization.
Positive factors
- High-grade historical copper rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“7.1% Cu and 173.5 g/t Ag (Raiden 2020)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 15Myrnas Hill · silverGrade: 173.5Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 173.5
- Grade Unit
- g/t
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2020-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Strong-grade historical silver rock chip, indicating significant surface mineralization.
Positive factors
- Strong-grade historical silver rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“7.1% Cu and 173.5 g/t Ag (Raiden 2020)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 16Myrnas Hill · copperGrade: 42.8Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 42.8
- Grade Unit
- %
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2007-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Exceptional-grade historical copper rock chip, indicating very strong surface mineralization.
Positive factors
- Exceptional-grade historical copper rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“42.8% Cu and 47.7g/t Ag (Shaw River, 2007)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Fact 17Myrnas Hill · silverGrade: 47.7Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- Pilbara region of Western Australia
- Ticker
- SLA
Geometry
- Grade
- 47.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2007-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Moderate-grade historical silver rock chip, indicating surface mineralization.
Positive factors
- Moderate-grade historical silver rock chip
Negative factors
- Historical data, low novelty
- No QA/QC Disclosure for historical data
Evidence · text
“42.8% Cu and 47.7g/t Ag (Shaw River, 2007)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.014Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.014
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“14”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0163Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0163
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“163”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.0023Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0023
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“23”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0806Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0806
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“806”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.007Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.007
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.00825Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00825
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“82.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00092Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00092
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“9.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0643Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0643
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“643”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.024Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.024
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“24”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0139Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0139
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“139”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00078Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00078
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7.8”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0902Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0902
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“902”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.006Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.006
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.026Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.026
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“260”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00466Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00466
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“46.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.131Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.131
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“1310”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.004Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.004
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“4”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0126Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0126
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“126”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00312Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00312
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“31.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.104Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.104
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“1040”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.005Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.005
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0107Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0107
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“107”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00556Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00556
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“55.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0907Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0907
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“907”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.011Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.011
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“11”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.00525Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00525
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“52.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.0229Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0229
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“229”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.116Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.116
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“1160”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.078Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.078
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“78”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.2Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0097Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0097
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“97”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00822Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00822
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“82.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0774Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0774
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“774”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.019Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.019
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“19”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.15Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.15”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0085Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0085
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“85”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.004Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.004
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“40”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0822Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0822
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“822”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.048Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.048
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“48”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.3Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.3”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0071Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0071
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“71”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.0042Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0042
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“42”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0872Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0872
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“872”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.029Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.029
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“29”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.00375Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00375
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“37.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00208Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00208
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“20.8”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0713Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0713
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“713”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.01Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 44 m
- To
- 48 m
- Intercept Depth
- 44 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:44-48
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“10”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.05Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 44 m
- To
- 48 m
- Intercept Depth
- 44 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:44-48
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.05”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.00275Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00275
- Grade Unit
- %
- Intercept
- 4 m
- From
- 44 m
- To
- 48 m
- Intercept Depth
- 44 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:44-48
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“27.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00112Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00112
- Grade Unit
- %
- Intercept
- 4 m
- From
- 44 m
- To
- 48 m
- Intercept Depth
- 44 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:44-48
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“11.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.026Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.026
- Grade Unit
- %
- Intercept
- 4 m
- From
- 44 m
- To
- 48 m
- Intercept Depth
- 44 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:44-48
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“260”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · goldGrade: 0.005Grade Unit: g/tIntercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.005
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 48 m
- To
- 53 m
- Intercept Depth
- 48 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:48-53
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“5”
Context: 5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · silverGrade: 0.05Grade Unit: g/tIntercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 48 m
- To
- 53 m
- Intercept Depth
- 48 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:48-53
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.05”
Context: 5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · copperGrade: 0.0054Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0054
- Grade Unit
- %
- Intercept
- 5 m
- From
- 48 m
- To
- 53 m
- Intercept Depth
- 48 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:48-53
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“54”
Context: 5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · arsenicGrade: 0.00078Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00078
- Grade Unit
- %
- Intercept
- 5 m
- From
- 48 m
- To
- 53 m
- Intercept Depth
- 48 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:48-53
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7.8”
Context: 5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM04Myrnas Hill · nickelGrade: 0.0234Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM04
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0234
- Grade Unit
- %
- Intercept
- 5 m
- From
- 48 m
- To
- 53 m
- Intercept Depth
- 48 m
Classification
- Sample Type
- drill
- Group ID
- FWM04:48-53
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“234”
Context: 5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.007Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.007
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.05Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.05”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0062Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0062
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“62”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.0004Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0004
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“4”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0171Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0171
- Grade Unit
- %
- Intercept
- 4 m
- From
- 0 m
- To
- 4 m
- Intercept Depth
- 0 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:0-4
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“171”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.005Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.005
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.05Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.05”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.00425Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00425
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“42.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.0005Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0005
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0164Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0164
- Grade Unit
- %
- Intercept
- 4 m
- From
- 4 m
- To
- 8 m
- Intercept Depth
- 4 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:4-8
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“164”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.045Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.045
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“45”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0353Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0353
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“353”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00094Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00094
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“9.4”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0304Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0304
- Grade Unit
- %
- Intercept
- 4 m
- From
- 8 m
- To
- 12 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:8-12
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“304”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.008Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.008
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“8”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.2Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0102Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0102
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“102”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00076Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00076
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0632Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0632
- Grade Unit
- %
- Intercept
- 4 m
- From
- 12 m
- To
- 16 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:12-16
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“632”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.007Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.007
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.2Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.2”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0144Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0144
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“144”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.0011Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0011
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“11”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0296Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0296
- Grade Unit
- %
- Intercept
- 4 m
- From
- 16 m
- To
- 20 m
- Intercept Depth
- 16 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:16-20
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“296”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.03Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“30”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.35Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.35”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0337Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0337
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“337”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00128Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00128
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“12.8”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0334Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0334
- Grade Unit
- %
- Intercept
- 4 m
- From
- 20 m
- To
- 24 m
- Intercept Depth
- 20 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:20-24
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“334”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.01Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“10”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.4Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.4”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.032Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.032
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“320”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00064Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00064
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“6.4”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0555Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0555
- Grade Unit
- %
- Intercept
- 4 m
- From
- 24 m
- To
- 28 m
- Intercept Depth
- 24 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:24-28
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“555”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.027Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.027
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“27”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.3Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.3”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0231Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0231
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“231”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00308Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00308
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“30.8”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0159Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0159
- Grade Unit
- %
- Intercept
- 4 m
- From
- 28 m
- To
- 32 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-32
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“159”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.008Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.008
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 28 m
- To
- 29 m
- Intercept Depth
- 28 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:28-29
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“8”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.008Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.008
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 29 m
- To
- 30 m
- Intercept Depth
- 29 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:29-30
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“8”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.057Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.057
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“57”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.1Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.1”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.00605Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00605
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“60.5”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00076Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00076
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0102Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0102
- Grade Unit
- %
- Intercept
- 4 m
- From
- 32 m
- To
- 36 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“102”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.014Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.014
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 32 m
- To
- 33 m
- Intercept Depth
- 32 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:32-33
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“14”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.08Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 33 m
- To
- 34 m
- Intercept Depth
- 33 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:33-34
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“80”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.149Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.149
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 34 m
- To
- 35 m
- Intercept Depth
- 34 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:34-35
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“149”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.064Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.064
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 35 m
- To
- 36 m
- Intercept Depth
- 35 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:35-36
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“64”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.063Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.063
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“63”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.25Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.25”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0526Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0526
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“526”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00256Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00256
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“25.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.048Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.048
- Grade Unit
- %
- Intercept
- 4 m
- From
- 36 m
- To
- 40 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-40
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“480”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.038Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.038
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 36 m
- To
- 37 m
- Intercept Depth
- 36 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:36-37
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“38”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.007Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.007
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 37 m
- To
- 38 m
- Intercept Depth
- 37 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:37-38
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“7”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · goldGrade: 0.024Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- gold
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.024
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical gold intercept from RAB drilling.
Negative factors
- Very low-grade historical gold intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“24”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · silverGrade: 0.05Grade Unit: g/tIntercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- silver
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical silver intercept from RAB drilling.
Negative factors
- Very low-grade historical silver intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“0.05”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · copperGrade: 0.0038Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- copper
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0038
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical copper intercept from RAB drilling.
Negative factors
- Very low-grade historical copper intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“38”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · arsenicGrade: 0.00016Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- arsenic
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.00016
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Historical arsenic intercept from RAB drilling, indicating presence of a deleterious element.
Negative factors
- Deleterious element present
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“1.6”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FWM05Myrnas Hill · nickelGrade: 0.0174Grade Unit: %Intercept: 4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FWM05
- Project
- Myrnas Hill
- Commodity
- nickel
- Region
- australia_wa
- Reported Region
- australia_wa
- Ticker
- SLA
Geometry
- Grade
- 0.0174
- Grade Unit
- %
- Intercept
- 4 m
- From
- 40 m
- To
- 44 m
- Intercept Depth
- 40 m
Classification
- Sample Type
- drill
- Group ID
- FWM05:40-44
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2003-01-01T00:00:00.000Z
Dates
- Event date
- 2026-10-08T00:00:00.000Z
Reasoning: Very low-grade historical nickel intercept from RAB drilling.
Negative factors
- Very low-grade historical nickel intercept
- Historical data, low novelty
- Apparent Width Only
- No QA/QC Disclosure for historical data
Evidence · table
“174”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.