SHN: Gold mineralisation footprint extended at Sybil

Original announcement by asx on

Company
Sunshine Metals Limited
Ticker
SHN
Exchange
ASX
Region
North Queensland
Primary commodity
Gold
Secondary commodities
None reported
Document categories
Drill results
Extracted
2026-10-05 22:28:43 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Sunshine Metals Limited announced new drill results from its Sybil epithermal gold project in North Queensland, extending the gold mineralization footprint. The 66-hole RC drill program returned several high-grade intercepts, including 4m at 11.11 g/t gold from 62m (26FCRC031) and 2m at 20.22 g/t gold from 62m, and confirmed shallow mineralization at Francis Creek East. The results reinforce the project's potential as a significant gold discovery, with follow-up drilling planned to further test extensions and new targets.

Reasoning: The drill program successfully extended the gold mineralization footprint at the Sybil project with several high-grade intercepts, including new discoveries at Francis Creek East and infill drilling to support future resource classification. However, the lack of true width reporting and the presence of elevated antimony in some areas introduce some uncertainty.

Positive factors

  • High-grade intercepts, including 1m @ 34.10 g/t Au and 2m @ 20.22 g/t Au, demonstrate strong gold mineralization.
  • Extension of the gold mineralization footprint at Francis Creek and new shallow mineralization at Francis Creek East.
  • Infill drilling at A Vein tightened drill spacing to support future resource classification.
  • First-ever drilling at Francis Creek East successfully intercepted mineralization, indicating new prospectivity.
  • QA/QC procedures are disclosed, and the report is signed off by a Competent Person.

Negative factors

  • All reported intercept widths are downhole only, with no true widths provided, which may overstate actual thickness.
  • Elevated antimony in the eastern part of Francis Creek East indicates potential processing challenges or proximity to the top of the epithermal system.
  • Some holes returned no significant intercepts, and the Blue Range target showed only weak mineralization.

Facts used in scoring: 74

Classification and evidence

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The document explicitly states 'All drilling intercept widths reported herein are downhole width only, with no true widths reported.'

Evidence · text

“All drilling intercept widths reported herein are downhole width only, with no true widths reported.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes QA/QC disclosure, mentioning certified lab (ALS), QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“The QAQC procedures involved Blanks, Field Duplicates and CRMs inserted at a rate of 1 in 10 and it is considered that acceptable levels of accuracy and precision were established for the purposes of mineral resource estimation.”

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: The release notes elevated antimony values in the eastern part of the Francis Creek East prospect.

Evidence · text

“Elevated antimony is an indication of being “above” the prospective “Boiling Zone” target window (see Figure 5). The eastern end of the Francis Creek East prospect displays elevated antimony values relative to the west (see Figure 6) and presents a target for deeper drilling, planned for October 2026.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The A Vein drilling tightened drill spacing to 15m-20m spaced holes to support future resource classification.

Evidence · text

“The A Vein drilling tightened drill spacing to 15m-20m spaced holes to support future resource classification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The drilling extended gold mineralization at Francis Creek and included first-ever drilling at Francis Creek East.

Evidence · text

“Francis Creek continued to return significant gold mineralisation along the prospective A-Vein structure, including: o 4m @ 11.11g/t Au from 62m (26FCRC031), including 2m @ 20.22g/t Au from 62m, o 6m @ 3.76g/t Au from 20m (26FCRC001), and o 5m @ 3.52g/t Au from 25m (26FCRC018). • First ever drilling at Francis Creek East intercepted shallow mineralisation, including: o 3m @ 2.36g/t Au from 15m (26FCERC006), o 1m @ 5.08g/t Au from 44m (26FCERC005), and o 2m @ 2.20g/t Au from 36m (26FCERC001).”

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept of 1m @ 34.10 g/t Au (26FCRC031) is well above the exceptional threshold for epithermal gold (15 g/t Au for underground mining).

Evidence · table

“34.10”

Context: 1

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept of 2m @ 20.22 g/t Au (26FCRC031) is well above the exceptional threshold for epithermal gold (15 g/t Au for underground mining).

Evidence · table

“20.22”

Context: 2

Extracted facts

Stored fact records: 74. Some facts used in scoring do not have a stored record.

Drill Results (74)

26FCERC001Sybil · goldGrade: 2.2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCERC001
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.2
Grade Unit
g/t
Intercept
2 m
From
36 m
To
38 m
Hole Depth
53 m
Intercept Depth
36 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC001:36-38
Mining Method
underground

Location

Location
Francis Creek East
Easting
354700
Northing
7887560
Elevation
372 m
Azimuth
224 °
Dip
-60 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A shallow, narrow intercept from the first drilling at Francis Creek East, indicating new mineralization.

Positive factors

  • First-ever drilling at Francis Creek East.

Negative factors

  • Apparent width only.
  • Relatively narrow intercept.

Evidence · table

“2.20”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC003Sybil · goldGrade: 5.08Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC003
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
5.08
Grade Unit
g/t
Intercept
1 m
From
44 m
To
45 m
Hole Depth
59 m
Intercept Depth
44 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC003:44-45
Mining Method
underground

Location

Location
Francis Creek East
Easting
354749
Northing
7887542
Elevation
376 m
Azimuth
181 °
Dip
-60 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A strong grade over a very narrow interval from the first drilling at Francis Creek East, indicating high-grade potential.

Positive factors

  • First-ever drilling at Francis Creek East.
  • Grade is strong for epithermal gold (5.08 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“5.08”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC006Sybil · goldGrade: 2.36Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCERC006
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.36
Grade Unit
g/t
Intercept
3 m
From
15 m
To
18 m
Hole Depth
28 m
Intercept Depth
15 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC006:15-18
Mining Method
underground

Location

Location
Francis Creek East
Easting
354810
Northing
7887500
Elevation
376 m
Azimuth
2 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A shallow intercept from the first drilling at Francis Creek East, indicating new mineralization.

Positive factors

  • First-ever drilling at Francis Creek East.
  • Shallow intercept.

Negative factors

  • Apparent width only.

Evidence · table

“2.36”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC006Sybil · goldGrade: 6.14Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC006
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
6.14
Grade Unit
g/t
Intercept
1 m
From
15 m
To
16 m
Hole Depth
28 m
Intercept Depth
15 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC006:15-16
Mining Method
underground

Location

Location
Francis Creek East
Easting
354810
Northing
7887500
Elevation
376 m
Azimuth
2 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval from the first drilling at Francis Creek East, indicating bonanza potential within the broader intercept.

Positive factors

  • First-ever drilling at Francis Creek East.
  • High-grade sub-interval (6.14 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“6.14”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC008Sybil · goldGrade: 0.91Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC008
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.91
Grade Unit
g/t
Intercept
1 m
From
7 m
To
8 m
Hole Depth
34 m
Intercept Depth
7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC008:7-8
Mining Method
underground

Location

Location
Francis Creek East
Easting
354869
Northing
7887497
Elevation
384 m
Azimuth
360 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A very shallow, low-grade, and narrow intercept from the first drilling at Francis Creek East.

Positive factors

  • First-ever drilling at Francis Creek East.
  • Very shallow intercept.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.91”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC009Sybil · goldGrade: 0.5Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC009
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
1 m
From
13 m
To
14 m
Hole Depth
59 m
Intercept Depth
13 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC009:13-14
Mining Method
underground

Location

Location
Francis Creek East
Easting
354905
Northing
7887491
Elevation
387 m
Azimuth
358 °
Dip
-60 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow intercept at the cut-off grade from the first drilling at Francis Creek East.

Positive factors

  • First-ever drilling at Francis Creek East.

Negative factors

  • Apparent width only.
  • Grade at cut-off and narrow intercept.

Evidence · table

“0.50”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC011Sybil · goldGrade: 0.92Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC011
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.92
Grade Unit
g/t
Intercept
1 m
From
82 m
To
83 m
Hole Depth
89 m
Intercept Depth
82 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC011:82-83
Mining Method
underground

Location

Location
Francis Creek East
Easting
354931
Northing
7887473
Elevation
393 m
Azimuth
359 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept from the first drilling at Francis Creek East.

Positive factors

  • First-ever drilling at Francis Creek East.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.92”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC011Sybil · goldGrade: 1.3Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCERC011
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.3
Grade Unit
g/t
Intercept
2 m
From
87 m
To
89 m
Hole Depth
89 m
Intercept Depth
87 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC011:87-89
Mining Method
underground

Location

Location
Francis Creek East
Easting
354931
Northing
7887473
Elevation
393 m
Azimuth
359 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept from the first drilling at Francis Creek East.

Positive factors

  • First-ever drilling at Francis Creek East.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“1.30”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCERC020Sybil · goldGrade: 0.7Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCERC020
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Hole Depth
95 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCERC020:27-28
Mining Method
underground

Location

Location
Francis Creek East
Easting
355063
Northing
7887484
Elevation
404 m
Azimuth
225 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept from the first drilling at Francis Creek East.

Positive factors

  • First-ever drilling at Francis Creek East.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.70”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC001Sybil · goldGrade: 0.93Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC001
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.93
Grade Unit
g/t
Intercept
2 m
From
9 m
To
11 m
Hole Depth
52 m
Intercept Depth
9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC001:9-11
Mining Method
underground

Location

Location
Francis Creek
Easting
353386
Northing
7887240
Elevation
393 m
Azimuth
46 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A shallow, low-grade intercept from Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.93”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC001Sybil · goldGrade: 1.26Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC001
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.26
Grade Unit
g/t
Intercept
1 m
From
10 m
To
11 m
Hole Depth
52 m
Intercept Depth
9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC001:10-11
Mining Method
underground

Location

Location
Francis Creek
Easting
353386
Northing
7887240
Elevation
393 m
Azimuth
46 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow sub-interval from Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.26”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC001Sybil · goldGrade: 3.76Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
26FCRC001
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.76
Grade Unit
g/t
Intercept
6 m
From
20 m
To
26 m
Hole Depth
52 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC001:20-26
Mining Method
underground

Location

Location
Francis Creek
Easting
353386
Northing
7887240
Elevation
393 m
Azimuth
46 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Positive factors

  • Moderate grade over a reasonable width.

Negative factors

  • Apparent width only.

Evidence · table

“3.76”

Context: 6

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC001Sybil · goldGrade: 9.47Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC001
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
9.47
Grade Unit
g/t
Intercept
1 m
From
24 m
To
25 m
Hole Depth
52 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC001:24-25
Mining Method
underground

Location

Location
Francis Creek
Easting
353386
Northing
7887240
Elevation
393 m
Azimuth
46 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval within a broader intercept at Francis Creek, indicating bonanza potential.

Positive factors

  • High-grade sub-interval (9.47 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“9.47”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC002Sybil · goldGrade: 1.57Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
26FCRC002
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.57
Grade Unit
g/t
Intercept
5 m
From
42 m
To
47 m
Hole Depth
95 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC002:42-47
Mining Method
underground

Location

Location
Francis Creek
Easting
353392
Northing
7887232
Elevation
392 m
Azimuth
51 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“1.57”

Context: 5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC002Sybil · goldGrade: 2.29Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCRC002
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.29
Grade Unit
g/t
Intercept
3 m
From
44 m
To
47 m
Hole Depth
95 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC002:44-47
Mining Method
underground

Location

Location
Francis Creek
Easting
353392
Northing
7887232
Elevation
392 m
Azimuth
51 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade sub-interval within a broader intercept at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“2.29”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC002Sybil · goldGrade: 3.07Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC002
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.07
Grade Unit
g/t
Intercept
1 m
From
60 m
To
61 m
Hole Depth
95 m
Intercept Depth
60 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC002:60-61
Mining Method
underground

Location

Location
Francis Creek
Easting
353392
Northing
7887232
Elevation
392 m
Azimuth
51 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“3.07”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC004Sybil · goldGrade: 0.83Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC004
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.83
Grade Unit
g/t
Intercept
1 m
From
5 m
To
6 m
Hole Depth
53 m
Intercept Depth
5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC004:5-6
Mining Method
underground

Location

Location
Francis Creek
Easting
353400
Northing
7887218
Elevation
392 m
Azimuth
48 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A very shallow, low-grade, and narrow intercept at Francis Creek.

Positive factors

  • Very shallow intercept.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.83”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC004Sybil · goldGrade: 1.36Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC004
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.36
Grade Unit
g/t
Intercept
2 m
From
24 m
To
26 m
Hole Depth
53 m
Intercept Depth
24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC004:24-26
Mining Method
underground

Location

Location
Francis Creek
Easting
353400
Northing
7887218
Elevation
392 m
Azimuth
48 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“1.36”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC004Sybil · goldGrade: 2.13Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC004
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.13
Grade Unit
g/t
Intercept
1 m
From
25 m
To
26 m
Hole Depth
53 m
Intercept Depth
24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC004:25-26
Mining Method
underground

Location

Location
Francis Creek
Easting
353400
Northing
7887218
Elevation
392 m
Azimuth
48 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade, narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“2.13”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC005Sybil · goldGrade: 0.71Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC005
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.71
Grade Unit
g/t
Intercept
2 m
From
10 m
To
12 m
Hole Depth
22 m
Intercept Depth
10 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC005:10-12
Mining Method
underground

Location

Location
Francis Creek
Easting
353401
Northing
7887219
Elevation
390 m
Azimuth
48 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A shallow, low-grade, and narrow intercept at Francis Creek.

Positive factors

  • Shallow intercept.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.71”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC012Sybil · goldGrade: 1.17Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC012
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.17
Grade Unit
g/t
Intercept
1 m
From
6 m
To
7 m
Hole Depth
89 m
Intercept Depth
6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC012:6-7
Mining Method
underground

Location

Location
Francis Creek
Easting
353514
Northing
7887115
Elevation
387 m
Azimuth
230 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A very shallow, low-grade, and narrow intercept at Francis Creek.

Positive factors

  • Very shallow intercept.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.17”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC015Sybil · goldGrade: 2.32Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
26FCRC015
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.32
Grade Unit
g/t
Intercept
5 m
From
114 m
To
119 m
Hole Depth
137 m
Intercept Depth
114 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC015:114-119
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887254
Elevation
400 m
Azimuth
56 °
Dip
-63 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“2.32”

Context: 5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC015Sybil · goldGrade: 5.73Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC015
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
5.73
Grade Unit
g/t
Intercept
1 m
From
114 m
To
115 m
Hole Depth
137 m
Intercept Depth
114 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC015:114-115
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887254
Elevation
400 m
Azimuth
56 °
Dip
-63 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • High-grade sub-interval (5.73 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“5.73”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC016Sybil · goldGrade: 0.97Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC016
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.97
Grade Unit
g/t
Intercept
2 m
From
55 m
To
57 m
Hole Depth
70 m
Intercept Depth
55 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC016:55-57
Mining Method
underground

Location

Location
Francis Creek
Easting
353347
Northing
7887257
Elevation
400 m
Azimuth
36 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.97”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC016Sybil · goldGrade: 1.36Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC016
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.36
Grade Unit
g/t
Intercept
1 m
From
56 m
To
57 m
Hole Depth
70 m
Intercept Depth
55 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC016:56-57
Mining Method
underground

Location

Location
Francis Creek
Easting
353347
Northing
7887257
Elevation
400 m
Azimuth
36 °
Dip
-50 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.36”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC017Sybil · goldGrade: 0.76Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC017
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.76
Grade Unit
g/t
Intercept
1 m
From
48 m
To
49 m
Hole Depth
74 m
Intercept Depth
48 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC017:48-49
Mining Method
underground

Location

Location
Francis Creek
Easting
353324
Northing
7887308
Elevation
398 m
Azimuth
52 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.76”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC017Sybil · goldGrade: 2.84Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
26FCRC017
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.84
Grade Unit
g/t
Intercept
4 m
From
52 m
To
56 m
Hole Depth
74 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC017:52-56
Mining Method
underground

Location

Location
Francis Creek
Easting
353324
Northing
7887308
Elevation
398 m
Azimuth
52 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“2.84”

Context: 4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC017Sybil · goldGrade: 3.57Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCRC017
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.57
Grade Unit
g/t
Intercept
3 m
From
52 m
To
55 m
Hole Depth
74 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC017:52-55
Mining Method
underground

Location

Location
Francis Creek
Easting
353324
Northing
7887308
Elevation
398 m
Azimuth
52 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade sub-interval within a broader intercept at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“3.57”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC017Sybil · goldGrade: 0.99Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC017
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.99
Grade Unit
g/t
Intercept
1 m
From
58 m
To
59 m
Hole Depth
74 m
Intercept Depth
58 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC017:58-59
Mining Method
underground

Location

Location
Francis Creek
Easting
353324
Northing
7887308
Elevation
398 m
Azimuth
52 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.99”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC018Sybil · goldGrade: 3.52Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
26FCRC018
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.52
Grade Unit
g/t
Intercept
5 m
From
25 m
To
30 m
Hole Depth
40 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC018:25-30
Mining Method
underground

Location

Location
Francis Creek
Easting
353342
Northing
7887346
Elevation
410 m
Azimuth
234 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Positive factors

  • Moderate grade over a reasonable width.

Negative factors

  • Apparent width only.

Evidence · table

“3.52”

Context: 5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC018Sybil · goldGrade: 4.25Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
26FCRC018
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
4.25
Grade Unit
g/t
Intercept
4 m
From
26 m
To
30 m
Hole Depth
40 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC018:26-30
Mining Method
underground

Location

Location
Francis Creek
Easting
353342
Northing
7887346
Elevation
410 m
Azimuth
234 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A strong grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • Strong grade sub-interval (4.25 g/t Au).

Negative factors

  • Apparent width only.

Evidence · table

“4.25”

Context: 4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC018Sybil · goldGrade: 6.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC018
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
6.8
Grade Unit
g/t
Intercept
1 m
From
26 m
To
27 m
Hole Depth
40 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC018:26-27
Mining Method
underground

Location

Location
Francis Creek
Easting
353342
Northing
7887346
Elevation
410 m
Azimuth
234 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • High-grade sub-interval (6.80 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“6.80”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC018Sybil · goldGrade: 6.3Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC018
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
6.3
Grade Unit
g/t
Intercept
1 m
From
29 m
To
30 m
Hole Depth
40 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC018:29-30
Mining Method
underground

Location

Location
Francis Creek
Easting
353342
Northing
7887346
Elevation
410 m
Azimuth
234 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • High-grade sub-interval (6.30 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“6.30”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 1.05Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.05
Grade Unit
g/t
Intercept
1 m
From
49 m
To
50 m
Hole Depth
83 m
Intercept Depth
49 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:49-50
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.05”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 0.94Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.94
Grade Unit
g/t
Intercept
6 m
From
53 m
To
59 m
Hole Depth
83 m
Intercept Depth
53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:53-59
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade intercept over a reasonable width at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade.

Evidence · table

“0.94”

Context: 6

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 1.61Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.61
Grade Unit
g/t
Intercept
2 m
From
53 m
To
55 m
Hole Depth
83 m
Intercept Depth
53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:53-55
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade, narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.61”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 1.34Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.34
Grade Unit
g/t
Intercept
1 m
From
58 m
To
59 m
Hole Depth
83 m
Intercept Depth
53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:58-59
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.34”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 0.95Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.95
Grade Unit
g/t
Intercept
2 m
From
62 m
To
64 m
Hole Depth
83 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:62-64
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.95”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 1.33Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.33
Grade Unit
g/t
Intercept
1 m
From
63 m
To
64 m
Hole Depth
83 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:63-64
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.33”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC019Sybil · goldGrade: 1.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC019
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
1 m
From
66 m
To
67 m
Hole Depth
83 m
Intercept Depth
66 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC019:66-67
Mining Method
underground

Location

Location
Francis Creek
Easting
353315
Northing
7887389
Elevation
412 m
Azimuth
231 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.10”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC021Sybil · goldGrade: 1.82Grade Unit: g/tIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
26FCRC021
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.82
Grade Unit
g/t
Intercept
8 m
From
25 m
To
33 m
Hole Depth
52 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC021:25-33
Mining Method
underground

Location

Location
Francis Creek
Easting
353124
Northing
7887455
Elevation
441 m
Azimuth
202 °
Dip
-52 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a reasonable width at Francis Creek.

Positive factors

  • Reasonable width (8m).

Negative factors

  • Apparent width only.

Evidence · table

“1.82”

Context: 8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC021Sybil · goldGrade: 2Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
26FCRC021
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2
Grade Unit
g/t
Intercept
7 m
From
25 m
To
32 m
Hole Depth
52 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC021:25-32
Mining Method
underground

Location

Location
Francis Creek
Easting
353124
Northing
7887455
Elevation
441 m
Azimuth
202 °
Dip
-52 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade sub-interval over a reasonable width at Francis Creek.

Positive factors

  • Reasonable width (7m).

Negative factors

  • Apparent width only.

Evidence · table

“2.00”

Context: 7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC021Sybil · goldGrade: 5.57Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC021
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
5.57
Grade Unit
g/t
Intercept
1 m
From
28 m
To
29 m
Hole Depth
52 m
Intercept Depth
25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC021:28-29
Mining Method
underground

Location

Location
Francis Creek
Easting
353124
Northing
7887455
Elevation
441 m
Azimuth
202 °
Dip
-52 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • High-grade sub-interval (5.57 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“5.57”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC022Sybil · goldGrade: 0.64Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC022
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.64
Grade Unit
g/t
Intercept
1 m
From
26 m
To
27 m
Hole Depth
52 m
Intercept Depth
26 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC022:26-27
Mining Method
underground

Location

Location
Francis Creek
Easting
353199
Northing
7887435
Elevation
439 m
Azimuth
202 °
Dip
-56 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.64”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC024Sybil · goldGrade: 2.12Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC024
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.12
Grade Unit
g/t
Intercept
2 m
From
11 m
To
13 m
Hole Depth
35 m
Intercept Depth
11 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC024:11-13
Mining Method
underground

Location

Location
Francis Creek
Easting
353347
Northing
7887497
Elevation
427 m
Azimuth
88 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A shallow, moderate grade, and narrow intercept at Francis Creek.

Positive factors

  • Shallow intercept.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“2.12”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC024Sybil · goldGrade: 3.62Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC024
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.62
Grade Unit
g/t
Intercept
1 m
From
11 m
To
12 m
Hole Depth
35 m
Intercept Depth
11 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC024:11-12
Mining Method
underground

Location

Location
Francis Creek
Easting
353347
Northing
7887497
Elevation
427 m
Azimuth
88 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A strong grade sub-interval within a broader intercept at Francis Creek.

Positive factors

  • Strong grade sub-interval (3.62 g/t Au).

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“3.62”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC026Sybil · goldGrade: 1.27Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC026
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.27
Grade Unit
g/t
Intercept
1 m
From
36 m
To
37 m
Hole Depth
77 m
Intercept Depth
36 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC026:36-37
Mining Method
underground

Location

Location
Francis Creek
Easting
353318
Northing
7887472
Elevation
422 m
Azimuth
92 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.27”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC026Sybil · goldGrade: 0.72Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC026
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.72
Grade Unit
g/t
Intercept
1 m
From
39 m
To
40 m
Hole Depth
77 m
Intercept Depth
39 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC026:39-40
Mining Method
underground

Location

Location
Francis Creek
Easting
353318
Northing
7887472
Elevation
422 m
Azimuth
92 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.72”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC027Sybil · goldGrade: 0.91Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCRC027
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.91
Grade Unit
g/t
Intercept
3 m
From
43 m
To
46 m
Hole Depth
58 m
Intercept Depth
43 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC027:43-46
Mining Method
underground

Location

Location
Francis Creek
Easting
353283
Northing
7887410
Elevation
420 m
Azimuth
232 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade intercept over a narrow width at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade.

Evidence · table

“0.91”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC027Sybil · goldGrade: 1.37Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC027
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.37
Grade Unit
g/t
Intercept
1 m
From
43 m
To
44 m
Hole Depth
58 m
Intercept Depth
43 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC027:43-44
Mining Method
underground

Location

Location
Francis Creek
Easting
353283
Northing
7887410
Elevation
420 m
Azimuth
232 °
Dip
-51 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.37”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC030Sybil · goldGrade: 0.56Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC030
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.56
Grade Unit
g/t
Intercept
1 m
From
21 m
To
22 m
Hole Depth
40 m
Intercept Depth
21 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC030:21-22
Mining Method
underground

Location

Location
Francis Creek
Easting
353351
Northing
7887388
Elevation
412 m
Azimuth
274 °
Dip
-58 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A narrow intercept at the cut-off grade at Francis Creek.

Negative factors

  • Apparent width only.
  • Grade at cut-off and narrow intercept.

Evidence · table

“0.56”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC031Sybil · goldGrade: 11.11Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
26FCRC031
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
11.11
Grade Unit
g/t
Intercept
4 m
From
62 m
To
66 m
Hole Depth
89 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC031:62-66
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887355
Elevation
406 m
Azimuth
251 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: An exceptional grade intercept over a good width at Francis Creek, significantly extending mineralization.

Positive factors

  • Exceptional grade (11.11 g/t Au) for epithermal gold.
  • Good width (4m).

Negative factors

  • Apparent width only.

Evidence · table

“11.11”

Context: 4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC031Sybil · goldGrade: 14.54Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCRC031
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
14.54
Grade Unit
g/t
Intercept
3 m
From
62 m
To
65 m
Hole Depth
89 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC031:62-65
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887355
Elevation
406 m
Azimuth
251 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: An exceptional grade sub-interval over a good width at Francis Creek, indicating very high-grade mineralization.

Positive factors

  • Exceptional grade (14.54 g/t Au) for epithermal gold.
  • Good width (3m).

Negative factors

  • Apparent width only.

Evidence · table

“14.54”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC031Sybil · goldGrade: 20.22Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC031
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
20.22
Grade Unit
g/t
Intercept
2 m
From
62 m
To
64 m
Hole Depth
89 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC031:62-64
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887355
Elevation
406 m
Azimuth
251 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A bonanza grade sub-interval over a good width at Francis Creek, representing a highly significant intercept.

Positive factors

  • Bonanza grade (20.22 g/t Au) for epithermal gold.
  • Good width (2m).

Negative factors

  • Apparent width only.

Evidence · table

“20.22”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC031Sybil · goldGrade: 34.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC031
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
34.1
Grade Unit
g/t
Intercept
1 m
From
62 m
To
63 m
Hole Depth
89 m
Intercept Depth
62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC031:62-63
Mining Method
underground

Location

Location
Francis Creek
Easting
353352
Northing
7887355
Elevation
406 m
Azimuth
251 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
10
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A bonanza grade sub-interval within a broader intercept at Francis Creek, representing a highly significant intercept.

Positive factors

  • Bonanza grade (34.10 g/t Au) for epithermal gold.
  • Exceptional grade for underground mining.

Negative factors

  • Apparent width only.
  • Very narrow intercept (1m).

Evidence · table

“34.10”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 1.42Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.42
Grade Unit
g/t
Intercept
2 m
From
20 m
To
22 m
Hole Depth
118 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:20-22
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“1.42”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 2.26Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.26
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Hole Depth
118 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:20-21
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade, narrow sub-interval at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“2.26”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 0.76Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.76
Grade Unit
g/t
Intercept
2 m
From
46 m
To
48 m
Hole Depth
118 m
Intercept Depth
46 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:46-48
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.76”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 1.13Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
1.13
Grade Unit
g/t
Intercept
1 m
From
50 m
To
51 m
Hole Depth
118 m
Intercept Depth
50 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:50-51
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Narrow intercept.

Evidence · table

“1.13”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 0.79Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.79
Grade Unit
g/t
Intercept
1 m
From
81 m
To
82 m
Hole Depth
118 m
Intercept Depth
81 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:81-82
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A low-grade, narrow intercept at Francis Creek.

Negative factors

  • Apparent width only.
  • Low grade and narrow intercept.

Evidence · table

“0.79”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26FCRC032Sybil · goldGrade: 2.52Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
26FCRC032
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
2.52
Grade Unit
g/t
Intercept
3 m
From
97 m
To
100 m
Hole Depth
118 m
Intercept Depth
97 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26FCRC032:97-100
Mining Method
underground

Location

Location
Francis Creek
Easting
353382
Northing
7887365
Elevation
415 m
Azimuth
242 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade intercept over a narrow width at Francis Creek.

Negative factors

  • Apparent width only.

Evidence · table

“2.52”

Context: 3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26BRRC005Sybil · goldGrade: 0.49Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26BRRC005
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
1 m
From
31 m
To
32 m
Hole Depth
47 m
Intercept Depth
31 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
26BRRC005:31-32
Mining Method
underground

Location

Location
Blue Range
Easting
352159
Northing
7892634
Elevation
439 m
Azimuth
167 °
Dip
-61 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: The best intercept at Blue Range was low-grade and narrow, indicating limited gold mineralization in this area.

Negative factors

  • Apparent width only.
  • Grade below typical cut-off.
  • Narrow intercept.

Evidence · text

“1m @ 0.49g/t Au from 31m (26BRRC005)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD002Sybil · goldGrade: 6.12Grade Unit: g/tIntercept: 3.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD002
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
6.12
Grade Unit
g/t
Intercept
3.8 m
From
22.6 m
To
26.4 m
Intercept Depth
22.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD002:22.6-26.4
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2025-11-17T00:00:00.000Z

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical high-grade intercept from the 2025 diamond drilling program at Francis Creek.

Positive factors

  • High-grade intercept (6.12 g/t Au).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“3.8m @ 6.12g/t Au from 22.6m (25FCDD002)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD003Sybil · goldGrade: 57.51Grade Unit: g/tIntercept: 4.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD003
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
57.51
Grade Unit
g/t
Intercept
4.4 m
From
23.6 m
To
28 m
Intercept Depth
23.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD003:23.6-28
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2025-10-13T00:00:00.000Z

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical bonanza grade intercept over a good width from the 2025 diamond drilling program at Francis Creek, indicating exceptional high-grade potential.

Positive factors

  • Bonanza grade (57.51 g/t Au) over a good width (4.4m).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“4.4m @ 57.51g/t Au from 23.6m (25FCDD003)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD007Sybil · goldGrade: 9.01Grade Unit: g/tIntercept: 5.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD007
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
9.01
Grade Unit
g/t
Intercept
5.2 m
From
52 m
To
57.2 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD007:52-57.2
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2025-10-22T00:00:00.000Z

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical exceptional grade intercept over a good width from the 2025 diamond drilling program at Francis Creek.

Positive factors

  • Exceptional grade (9.01 g/t Au) over a good width (5.2m).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“5.2m @ 9.01g/t Au from 52.0m (25FCDD007)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD008ASybil · goldGrade: 3.93Grade Unit: g/tIntercept: 7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD008A
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
3.93
Grade Unit
g/t
Intercept
7 m
From
65 m
To
72 m
Intercept Depth
65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD008A:65-72
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical moderate grade intercept over a strong width from the 2025 diamond drilling program at Francis Creek.

Positive factors

  • Moderate grade over a strong width (7m).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“7.0m @ 3.93g/t Au from 65.0m (25FCDD008A)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD010Sybil · goldGrade: 15.15Grade Unit: g/tIntercept: 2.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD010
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
15.15
Grade Unit
g/t
Intercept
2.8 m
From
37 m
To
39.8 m
Intercept Depth
37 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD010:37-39.8
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical exceptional grade intercept over a good width from the 2025 diamond drilling program at Francis Creek.

Positive factors

  • Exceptional grade (15.15 g/t Au) over a good width (2.8m).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“2.8m @ 15.15g/t Au from 37.0m (25FCDD010)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25FCDD012Sybil · goldGrade: 17.23Grade Unit: g/tIntercept: 4.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
25FCDD012
Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
australia_qld
Ticker
SHN

Geometry

Grade
17.23
Grade Unit
g/t
Intercept
4.5 m
From
82.5 m
To
87 m
Intercept Depth
82.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
25FCDD012:82.5-87
Mining Method
underground

Location

Location
Francis Creek
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A historical exceptional grade intercept over a good width from the 2025 diamond drilling program at Francis Creek.

Positive factors

  • Exceptional grade (17.23 g/t Au) over a good width (4.5m).

Negative factors

  • Apparent width only.
  • Historical result.

Evidence · text

“4.5m @ 17.23g/t Au from 82.5m (25FCDD012)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 69Sybil · goldGrade: 3.11Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
3.11
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Francis Creek East
Easting
354994
Northing
7887733
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A new vein identified north of Francis Creek East returned a strong gold grade from a rock chip sample, indicating new exploration potential.

Positive factors

  • New vein identified with strong gold grade.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“Sample collected from the vein returned 3.11g/t Au (FCE26_006).”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Fact 70Sybil · goldGrade: 21.6Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
21.6
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Pancho Vein
Easting
354866
Northing
7887267
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A bonanza grade rock chip sample from the Pancho Vein, indicating high-grade surface mineralization.

Positive factors

  • Bonanza grade (21.6 g/t Au) from surface sample.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“Pancho Vein returning 21.6g/t Au (CI26_008)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Fact 71Sybil · goldGrade: 9.48Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
9.48
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Cisco Vein
Easting
354590
Northing
7887006
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade rock chip sample from the Cisco Vein, indicating strong surface mineralization.

Positive factors

  • High-grade (9.48 g/t Au) from surface sample.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“Cisco Vein returning 9.48g/t Au (CI26_015)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Fact 72Sybil · goldGrade: 6.04Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
6.04
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Cisco Vein
Easting
354627
Northing
7886980
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A high-grade rock chip sample from the Cisco Vein, indicating strong surface mineralization.

Positive factors

  • High-grade (6.04 g/t Au) from surface sample.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“6.04g/t Au (CI26_001)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Fact 73Sybil · goldGrade: 1.97Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
1.97
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Cisco Vein
Easting
354583
Northing
7887014
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade rock chip sample from the Cisco Vein, indicating surface mineralization.

Positive factors

  • Moderate grade from surface sample.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“1.97g/t Au (CI26_003)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Fact 74Sybil · goldGrade: 1.7Grade Unit: g/tView all details
Link to this fact

Identity

Project
Sybil
Commodity
gold
Region
australia_qld
Reported Region
North Queensland
Ticker
SHN

Geometry

Grade
1.7
Grade Unit
g/t

Classification

Sample Type
surface

Location

Location
Cisco Vein
Easting
354570
Northing
7887031
CRS
GDA94, Zone 55
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
blanks, standards, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: A moderate grade rock chip sample from the Cisco Vein, indicating surface mineralization.

Positive factors

  • Moderate grade from surface sample.

Negative factors

  • Surface sample, not drill result.
  • Limited representativeness.

Evidence · text

“1.70g/t Au (CI26_004)”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.