Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, and 0.90 m of 1469 g/t AgEq at San Jose in Alamos Silver Project

Original announcement by newsfile on

Company
Minaurum Silver Inc.
Ticker
MGG
Exchange
Unavailable
Region
Sonora, Mexico
Primary commodity
Silver
Secondary commodities
Gold, Copper, Lead, Zinc
Document categories
Drill results, Resource update
Extracted
2026-09-24 13:06:32 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Minaurum Silver Inc. announced high-grade silver drill results from its ongoing 50,000-metre resource-expansion drilling program at the Alamos Silver Project in Sonora, Mexico. Highlights include 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, and 0.90 m of 1469 g/t AgEq at San Jose. The company noted strong continuity of high-grade silver vein zones and encouraging initial results from step-out drilling at Promontorio Sur, with an upcoming resource update planned.

Reasoning: The drill results report multiple high-grade silver equivalent intercepts, including bonanza grades, from step-out drilling across several vein zones at the Alamos Silver Project. The program is explicitly aimed at resource expansion, and the results indicate strong continuity and potential for growth. The disclosure includes true widths, detailed QA/QC, and transparent metal equivalent assumptions, all contributing to high confidence in the reported data.

Positive factors

  • Multiple high-grade silver equivalent intercepts, including bonanza grades over 1 kg/t AgEq, demonstrate strong mineralization.
  • Step-out drilling successfully extends known mineralization at Quintera and Europa Sur, and yields encouraging initial results at Promontorio Sur.
  • True widths are disclosed for all reported intercepts, providing greater confidence in the geometry.
  • Comprehensive QA/QC procedures are detailed, including independent lab analysis and QP sign-off, enhancing data reliability.
  • Metal equivalent assumptions (prices and recoveries) are fully disclosed, ensuring transparency.

Negative factors

  • Many intercepts are narrow, which is typical for vein-style mineralization but can impact mining economics.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 360

Extracted facts

Stored fact records: 360. Some facts used in scoring do not have a stored record.

Drill Results (360)

AL26-236Alamos · silverGrade: 162Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
162
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
341.7 m
To
342 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:341.7-342
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
203
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Good silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“162”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
341.7 m
To
342 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:341.7-342
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
203
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with no gold contribution, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • No gold grade.

Evidence · table

“0.00”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · copperGrade: 0.45Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.45
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
341.7 m
To
342 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:341.7-342
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
203
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.45”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · leadGrade: 0.11Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
341.7 m
To
342 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:341.7-342
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
203
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.11”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · zincGrade: 0.02Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
341.7 m
To
342 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:341.7-342
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
203
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low zinc grade, contributing marginally to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.02”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · silverGrade: 236Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
236
Grade Unit
g/t
Intercept
0.65 m
True Width
0.5 m
From
465.15 m
To
465.8 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:465.15-465.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
318
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“236”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.65 m
True Width
0.5 m
From
465.15 m
To
465.8 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:465.15-465.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
318
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · copperGrade: 0.84Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.84
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
465.15 m
To
465.8 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:465.15-465.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
318
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a good copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.84”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · leadGrade: 0.31Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.31
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
465.15 m
To
465.8 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:465.15-465.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
318
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.31”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · zincGrade: 0.1Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
465.15 m
To
465.8 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:465.15-465.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
318
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.10”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · silverGrade: 70Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
70
Grade Unit
g/t
Intercept
0.6 m
True Width
0.45 m
From
491 m
To
491.6 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:491-491.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
138
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low silver grade.
  • Narrow intercept length.

Evidence · table

“70”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · goldGrade: 0.11Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
0.6 m
True Width
0.45 m
From
491 m
To
491.6 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:491-491.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
138
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low gold grade.
  • Narrow intercept length.

Evidence · table

“0.11”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · copperGrade: 0.25Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.6 m
True Width
0.45 m
From
491 m
To
491.6 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:491-491.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
138
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.25”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · leadGrade: 0.27Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.27
Grade Unit
%
Intercept
0.6 m
True Width
0.45 m
From
491 m
To
491.6 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:491-491.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
138
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.27”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-236Alamos · zincGrade: 1.33Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-236
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.33
Grade Unit
%
Intercept
0.6 m
True Width
0.45 m
From
491 m
To
491.6 m
Intercept Depth
341.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-236:491-491.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
138
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.33”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · silverGrade: 263Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
263
Grade Unit
g/t
Intercept
1.9 m
True Width
1.35 m
From
227.8 m
To
229.7 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-229.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
323
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A strong silver intercept with good width and associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.
  • Good intercept length for narrow vein.

Evidence · table

“263”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
1.9 m
True Width
1.35 m
From
227.8 m
To
229.7 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-229.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
323
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.

Evidence · table

“0.02”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · copperGrade: 0.44Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.44
Grade Unit
%
Intercept
1.9 m
True Width
1.35 m
From
227.8 m
To
229.7 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-229.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
323
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.
  • Good intercept length for narrow vein.

Evidence · table

“0.44”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · leadGrade: 0.27Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.27
Grade Unit
%
Intercept
1.9 m
True Width
1.35 m
From
227.8 m
To
229.7 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-229.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
323
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.
  • Good intercept length for narrow vein.

Evidence · table

“0.27”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · zincGrade: 0.63Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.63
Grade Unit
%
Intercept
1.9 m
True Width
1.35 m
From
227.8 m
To
229.7 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-229.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
323
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.
  • Good intercept length for narrow vein.

Evidence · table

“0.63”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · silverGrade: 637Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
637
Grade Unit
g/t
Intercept
0.5 m
True Width
0.35 m
From
227.8 m
To
228.3 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-228.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
715
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but exceptionally high-grade silver intercept, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Exceptional silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“637”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.5 m
True Width
0.35 m
From
227.8 m
To
228.3 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-228.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
715
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with no gold contribution, but part of a high-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • No gold grade.

Evidence · table

“0.00”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · copperGrade: 0.69Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.69
Grade Unit
%
Intercept
0.5 m
True Width
0.35 m
From
227.8 m
To
228.3 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-228.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
715
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a good copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.69”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · leadGrade: 0.3Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.5 m
True Width
0.35 m
From
227.8 m
To
228.3 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-228.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
715
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.30”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-243Alamos · zincGrade: 0.53Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-243
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.53
Grade Unit
%
Intercept
0.5 m
True Width
0.35 m
From
227.8 m
To
228.3 m
Intercept Depth
227.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-243:227.8-228.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
715
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.53”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · silverGrade: 112Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
112
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
473.35 m
To
473.65 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:473.35-473.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
157
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“112”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
473.35 m
To
473.65 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:473.35-473.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
157
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with no gold contribution, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • No gold grade.

Evidence · table

“0.00”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · copperGrade: 0.26Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.26
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
473.35 m
To
473.65 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:473.35-473.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
157
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.26”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · leadGrade: 0.71Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.71
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
473.35 m
To
473.65 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:473.35-473.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
157
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.71”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · zincGrade: 0.38Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.38
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
473.35 m
To
473.65 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:473.35-473.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
157
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.38”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · silverGrade: 1460Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1460
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
565.05 m
To
565.55 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:565.05-565.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1559
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but bonanza-grade silver intercept with a very high associated AgEq value, indicating exceptional mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Bonanza silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1460”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · goldGrade: 0.04Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
565.05 m
To
565.55 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:565.05-565.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1559
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a bonanza-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.04”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · copperGrade: 1.11Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.11
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
565.05 m
To
565.55 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:565.05-565.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1559
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.11”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · leadGrade: 0.01Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
565.05 m
To
565.55 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:565.05-565.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1559
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low lead grade, contributing marginally to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low lead grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-250Alamos · zincGrade: 0.01Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-250
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
565.05 m
To
565.55 m
Intercept Depth
473.35 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-250:565.05-565.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1559
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low zinc grade, contributing marginally to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · silverGrade: 41Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
41
Grade Unit
g/t
Intercept
2.1 m
True Width
1.9 m
From
83.5 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
121
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low silver grade, but with an associated AgEq value, indicating some polymetallic contribution, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low silver grade.

Evidence · table

“41”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · goldGrade: 0.51Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.51
Grade Unit
g/t
Intercept
2.1 m
True Width
1.9 m
From
83.5 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
121
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate gold grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate gold grade for narrow vein.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Evidence · table

“0.51”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · copperGrade: 0.28Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.28
Grade Unit
%
Intercept
2.1 m
True Width
1.9 m
From
83.5 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
121
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.

Evidence · table

“0.28”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · leadGrade: 0.17Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.17
Grade Unit
%
Intercept
2.1 m
True Width
1.9 m
From
83.5 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
121
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.

Evidence · table

“0.17”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · zincGrade: 0.3Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
2.1 m
True Width
1.9 m
From
83.5 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
121
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.

Evidence · table

“0.30”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · silverGrade: 177Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
177
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
83.5 m
To
83.95 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-83.95
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
386
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but strong silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“177”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · goldGrade: 0.86Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.86
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
83.5 m
To
83.95 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-83.95
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
386
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate gold grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate gold grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.86”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · copperGrade: 1.18Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.18
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
83.5 m
To
83.95 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-83.95
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
386
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.18”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · leadGrade: 0.3Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
83.5 m
To
83.95 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-83.95
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
386
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.30”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · zincGrade: 1.04Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.04
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
83.5 m
To
83.95 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:83.5-83.95
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
386
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.04”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · silverGrade: 2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2
Grade Unit
g/t
Intercept
0.5 m
True Width
0.45 m
From
85.1 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:85.1-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
101
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low silver grade, but with an associated AgEq value, indicating some polymetallic contribution, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low silver grade.
  • Narrow intercept length.

Evidence · table

“2”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · goldGrade: 0.93Grade Unit: g/tIntercept: 0.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.93
Grade Unit
g/t
Intercept
0.5 m
True Width
0.45 m
From
85.1 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:85.1-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
101
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-01-28T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate gold grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate gold grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.93”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · copperGrade: 0.04Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
85.1 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:85.1-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
101
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low copper grade, contributing marginally to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low copper grade.
  • Narrow intercept length.

Evidence · table

“0.04”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · leadGrade: 0.33Grade Unit: %Intercept: 0.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.33
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
85.1 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:85.1-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
101
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-01-28T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.33”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-248Alamos · zincGrade: 0.26Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-248
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.26
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
85.1 m
To
85.6 m
Intercept Depth
83.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-248:85.1-85.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
101
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.26”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · silverGrade: 162Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
162
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
173.3 m
To
173.65 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:173.3-173.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
224
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“162”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · goldGrade: 0.05Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
173.3 m
To
173.65 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:173.3-173.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
224
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.05”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · copperGrade: 0.36Grade Unit: %Intercept: 0.35 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.36
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
173.3 m
To
173.65 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:173.3-173.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
224
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.36”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · leadGrade: 0.45Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.45
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
173.3 m
To
173.65 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:173.3-173.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
224
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.45”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · zincGrade: 0.75Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.75
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
173.3 m
To
173.65 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:173.3-173.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
224
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.75”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · silverGrade: 87Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
87
Grade Unit
g/t
Intercept
1.8 m
True Width
1.62 m
From
439.45 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
133
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low silver grade, but with an associated AgEq value, indicating some polymetallic contribution, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low silver grade.

Evidence · table

“87”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · goldGrade: 0Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
1.8 m
True Width
1.62 m
From
439.45 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
133
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with no gold contribution, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • No gold grade.

Evidence · table

“0.00”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · copperGrade: 0.38Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.38
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
439.45 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
133
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.

Evidence · table

“0.38”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · leadGrade: 0.32Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.32
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
439.45 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
133
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.

Evidence · table

“0.32”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · zincGrade: 0.29Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.29
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
439.45 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
133
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.

Evidence · table

“0.29”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · silverGrade: 261Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
261
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
439.45 m
To
439.75 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-439.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
341
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but strong silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“261”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
439.45 m
To
439.75 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-439.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
341
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a high-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · copperGrade: 0.8Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.8
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
439.45 m
To
439.75 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-439.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
341
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a good copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.80”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · leadGrade: 0.31Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.31
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
439.45 m
To
439.75 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-439.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
341
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.31”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · zincGrade: 0.18Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
439.45 m
To
439.75 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:439.45-439.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
341
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.18”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · silverGrade: 88Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
88
Grade Unit
g/t
Intercept
0.6 m
True Width
0.54 m
From
440.65 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:440.65-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
150
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“88”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.6 m
True Width
0.54 m
From
440.65 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:440.65-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
150
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · copperGrade: 0.5Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.5
Grade Unit
%
Intercept
0.6 m
True Width
0.54 m
From
440.65 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:440.65-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
150
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.50”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · leadGrade: 0.44Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.44
Grade Unit
%
Intercept
0.6 m
True Width
0.54 m
From
440.65 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:440.65-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
150
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.44”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · zincGrade: 0.42Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.42
Grade Unit
%
Intercept
0.6 m
True Width
0.54 m
From
440.65 m
To
441.25 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:440.65-441.25
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
150
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.42”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · silverGrade: 190Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
190
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
444.6 m
To
444.9 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:444.6-444.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
249
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“190”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
444.6 m
To
444.9 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:444.6-444.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
249
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · copperGrade: 0.37Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.37
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
444.6 m
To
444.9 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:444.6-444.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
249
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.37”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · leadGrade: 1.07Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.07
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
444.6 m
To
444.9 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:444.6-444.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
249
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.07”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-232Alamos · zincGrade: 0.24Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-232
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.24
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
444.6 m
To
444.9 m
Intercept Depth
173.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-232:444.6-444.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
249
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.24”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 314Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
314
Grade Unit
g/t
Intercept
1.6 m
True Width
1.36 m
From
135.2 m
To
136.8 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-136.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
412
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A strong silver intercept with good width and associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.
  • Good intercept length for narrow vein.

Evidence · table

“314”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.41Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
1.6 m
True Width
1.36 m
From
135.2 m
To
136.8 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-136.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
412
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate gold grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate gold grade for narrow vein.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Evidence · table

“0.41”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.42Grade Unit: %Intercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.42
Grade Unit
%
Intercept
1.6 m
True Width
1.36 m
From
135.2 m
To
136.8 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-136.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
412
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Evidence · table

“0.42”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.41Grade Unit: %Intercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.41
Grade Unit
%
Intercept
1.6 m
True Width
1.36 m
From
135.2 m
To
136.8 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-136.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
412
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Evidence · table

“0.41”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.77Grade Unit: %Intercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.77
Grade Unit
%
Intercept
1.6 m
True Width
1.36 m
From
135.2 m
To
136.8 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-136.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
412
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A good width intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Good intercept length for narrow vein.
  • Metal equivalent assumptions disclosed.

Evidence · table

“0.77”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 409Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
409
Grade Unit
g/t
Intercept
0.4 m
True Width
0.34 m
From
135.2 m
To
135.6 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-135.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
708
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but exceptionally high-grade silver intercept, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Exceptional silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“409”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 1.51Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.51
Grade Unit
g/t
Intercept
0.4 m
True Width
0.34 m
From
135.2 m
To
135.6 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-135.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
708
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong gold grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong gold grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.51”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 1.27Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.27
Grade Unit
%
Intercept
0.4 m
True Width
0.34 m
From
135.2 m
To
135.6 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-135.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
708
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.27”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.82Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.82
Grade Unit
%
Intercept
0.4 m
True Width
0.34 m
From
135.2 m
To
135.6 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-135.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
708
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong lead grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.82”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 1.66Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.66
Grade Unit
%
Intercept
0.4 m
True Width
0.34 m
From
135.2 m
To
135.6 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:135.2-135.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
708
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong zinc grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.66”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 274Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
274
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
170.95 m
To
171.4 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:170.95-171.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
335
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but strong silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“274”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.06Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
170.95 m
To
171.4 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:170.95-171.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
335
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.06”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.43Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.43
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
170.95 m
To
171.4 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:170.95-171.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
335
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.43”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.29Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.29
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
170.95 m
To
171.4 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:170.95-171.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
335
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.29”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.57Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.57
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
170.95 m
To
171.4 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:170.95-171.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
335
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.57”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 144Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
144
Grade Unit
g/t
Intercept
0.9 m
True Width
0.75 m
From
176.8 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:176.8-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
177
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“144”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.9 m
True Width
0.75 m
From
176.8 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:176.8-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
177
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.02”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.2Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.9 m
True Width
0.75 m
From
176.8 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:176.8-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
177
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.20”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.21Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.21
Grade Unit
%
Intercept
0.9 m
True Width
0.75 m
From
176.8 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:176.8-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
177
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.21”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.43Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.43
Grade Unit
%
Intercept
0.9 m
True Width
0.75 m
From
176.8 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:176.8-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
177
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.43”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 340Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
340
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
177.4 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:177.4-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
409
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but strong silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“340”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.04Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
177.4 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:177.4-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
409
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.04”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.38Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.38
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
177.4 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:177.4-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
409
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.38”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.49Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.49
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
177.4 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:177.4-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
409
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.49”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 1Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
177.4 m
To
177.7 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:177.4-177.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
409
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“1.00”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 444Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
444
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
238.75 m
To
239.05 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:238.75-239.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
528
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but exceptionally high-grade silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Exceptional silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“444”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.08Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
238.75 m
To
239.05 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:238.75-239.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
528
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a high-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.08”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.76Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.76
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
238.75 m
To
239.05 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:238.75-239.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
528
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a good copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.76”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.45Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.45
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
238.75 m
To
239.05 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:238.75-239.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
528
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.45”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.12Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.12
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
238.75 m
To
239.05 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:238.75-239.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
528
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.12”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 620Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
620
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
283.2 m
To
283.5 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:283.2-283.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but exceptionally high-grade silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Exceptional silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“620”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.07Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
283.2 m
To
283.5 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:283.2-283.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a high-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.07”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.52Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.52
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
283.2 m
To
283.5 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:283.2-283.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.52”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.58Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.58
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
283.2 m
To
283.5 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:283.2-283.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.58”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.17Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.17
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
283.2 m
To
283.5 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:283.2-283.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.17”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 166Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
166
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
289.9 m
To
290.2 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:289.9-290.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
194
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“166”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.05Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
289.9 m
To
290.2 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:289.9-290.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
194
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.05”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.19Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.19
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
289.9 m
To
290.2 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:289.9-290.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
194
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.19”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.21Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.21
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
289.9 m
To
290.2 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:289.9-290.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
194
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.21”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.14Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.14
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
289.9 m
To
290.2 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:289.9-290.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
194
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low zinc grade.
  • Narrow intercept length.

Evidence · table

“0.14”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · silverGrade: 471Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
471
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
309.05 m
To
309.35 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:309.05-309.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow but exceptionally high-grade silver intercept with a high associated AgEq value, indicating significant mineralization, with good disclosure.

Positive factors

  • True width disclosed.
  • Exceptional silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“471”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · goldGrade: 0.13Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.13
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
309.05 m
To
309.35 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:309.05-309.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low gold grade, but part of a high-grade polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low gold grade.
  • Narrow intercept length.

Evidence · table

“0.13”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · copperGrade: 0.63Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.63
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
309.05 m
To
309.35 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:309.05-309.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a good copper grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Good copper grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.63”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · leadGrade: 0.97Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.97
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
309.05 m
To
309.35 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:309.05-309.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a strong lead grade, contributing significantly to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Strong lead grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.97”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-233Alamos · zincGrade: 0.44Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-233
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.44
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
309.05 m
To
309.35 m
Intercept Depth
135.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-233:309.05-309.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.44”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-234Alamos · silverGrade: 114Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AL26-234
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
114
Grade Unit
g/t
Intercept
0.7 m
True Width
0.65 m
From
458.65 m
To
459.35 m
Intercept Depth
458.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-234:458.65-459.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
141
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“114”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-234Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AL26-234
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.7 m
True Width
0.65 m
From
458.65 m
To
459.35 m
Intercept Depth
458.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-234:458.65-459.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
141
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.01”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-234Alamos · copperGrade: 0.13Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AL26-234
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.13
Grade Unit
%
Intercept
0.7 m
True Width
0.65 m
From
458.65 m
To
459.35 m
Intercept Depth
458.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-234:458.65-459.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
141
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low copper grade.
  • Narrow intercept length.

Evidence · table

“0.13”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-234Alamos · leadGrade: 0.12Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AL26-234
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.12
Grade Unit
%
Intercept
0.7 m
True Width
0.65 m
From
458.65 m
To
459.35 m
Intercept Depth
458.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-234:458.65-459.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
141
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a low lead grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Low lead grade.
  • Narrow intercept length.

Evidence · table

“0.12”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-234Alamos · zincGrade: 0.54Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AL26-234
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.54
Grade Unit
%
Intercept
0.7 m
True Width
0.65 m
From
458.65 m
To
459.35 m
Intercept Depth
458.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-234:458.65-459.35
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
141
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic value, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate zinc grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“0.54”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-235Alamos · silverGrade: 141Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-235
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
141
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
264.1 m
To
264.4 m
Intercept Depth
264.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-235:264.1-264.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
226
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade and associated AgEq value, typical for epithermal vein systems, with good disclosure.

Positive factors

  • True width disclosed.
  • Moderate silver grade for narrow vein.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Narrow intercept length.

Evidence · table

“141”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-235Alamos · goldGrade: 0.05Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-235
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
264.1 m
To
264.4 m
Intercept Depth
264.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-235:264.1-264.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
226
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: A narrow intercept with a very low gold grade, but part of a polymetallic interval with good disclosure.

Positive factors

  • True width disclosed.
  • Metal equivalent assumptions disclosed.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.

Evidence · table

“0.05”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-235Alamos · copperGrade: 0.53Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-235
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.53
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
264.1 m
To
264.4 m
Intercept Depth
264.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
AL26-235:264.1-264.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
226
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Positive factors

  • True width disclosed.
  • Moderate copper grade for narrow vein.

Evidence · table

“0.53”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-235Alamos · leadGrade: 0.32Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-235
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.32
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
264.1 m
To
264.4 m
Intercept Depth
264.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-235:264.1-264.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
226
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.32 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.32”

Context: AL26-235

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-235Alamos · zincGrade: 1.19Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-235
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.19
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
264.1 m
To
264.4 m
Intercept Depth
264.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-235:264.1-264.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
226
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.19 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.4 %·m is below.

Negative factors

  • 1.19 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.19”

Context: AL26-235

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-237Alamos · silverGrade: 143Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-237
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
143
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
413.85 m
To
414.15 m
Intercept Depth
413.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-237:413.85-414.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 143 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 42.9 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“143”

Context: AL26-237

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-237Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-237
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
413.85 m
To
414.15 m
Intercept Depth
413.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-237:413.85-414.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AL26-237

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-237Alamos · copperGrade: 0.27Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-237
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.27
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
413.85 m
To
414.15 m
Intercept Depth
413.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-237:413.85-414.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: AL26-237

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-237Alamos · leadGrade: 0.13Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-237
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.13
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
413.85 m
To
414.15 m
Intercept Depth
413.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-237:413.85-414.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.13 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.13”

Context: AL26-237

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-237Alamos · zincGrade: 0.15Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-237
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.15
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
413.85 m
To
414.15 m
Intercept Depth
413.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-237:413.85-414.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.15 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: AL26-237

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 801Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
801
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
257.35 m
To
257.65 m
Intercept Depth
257.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:257.35-257.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
877
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 801 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 240.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 801 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“801”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 0.18Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
257.35 m
To
257.65 m
Intercept Depth
257.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:257.35-257.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
877
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.18 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 0.39Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.39
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
257.35 m
To
257.65 m
Intercept Depth
257.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:257.35-257.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
877
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.39”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 0.39Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.39
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
257.35 m
To
257.65 m
Intercept Depth
257.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:257.35-257.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
877
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.39 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.39”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 0.79Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.79
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
257.35 m
To
257.65 m
Intercept Depth
257.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:257.35-257.65
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
877
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.79 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.79 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.79”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 547Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
547
Grade Unit
g/t
Intercept
0.6 m
True Width
0.5 m
From
268.4 m
To
269 m
Intercept Depth
268.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:268.4-269
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
646
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 547 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 328.2 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 547 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“547”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 0.12Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.12
Grade Unit
g/t
Intercept
0.6 m
True Width
0.5 m
From
268.4 m
To
269 m
Intercept Depth
268.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:268.4-269
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
646
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.12 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.12”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 0.81Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.81
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
268.4 m
To
269 m
Intercept Depth
268.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:268.4-269
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
646
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.81 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.81”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 0.57Grade Unit: %Intercept: 0.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.57
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
268.4 m
To
269 m
Intercept Depth
268.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:268.4-269
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
646
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.57 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.57”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 0.31Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.31
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
268.4 m
To
269 m
Intercept Depth
268.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:268.4-269
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
646
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.31 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.31”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 79Grade Unit: g/tIntercept: 2.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
79
Grade Unit
g/t
Intercept
2.7 m
True Width
2.3 m
From
412.6 m
To
415.3 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-415.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 79 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 213.3 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“79”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 0.36Grade Unit: g/tIntercept: 2.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.36
Grade Unit
g/t
Intercept
2.7 m
True Width
2.3 m
From
412.6 m
To
415.3 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-415.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.0 g/t·m is below.

Negative factors

  • 0.36 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.36”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 0.27Grade Unit: %Intercept: 2.7 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.27
Grade Unit
%
Intercept
2.7 m
True Width
2.3 m
From
412.6 m
To
415.3 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-415.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.7 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 0.57Grade Unit: %Intercept: 2.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.57
Grade Unit
%
Intercept
2.7 m
True Width
2.3 m
From
412.6 m
To
415.3 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-415.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.5 %·m is below.

Negative factors

  • 0.57 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.57”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 1.4Grade Unit: %Intercept: 2.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.4
Grade Unit
%
Intercept
2.7 m
True Width
2.3 m
From
412.6 m
To
415.3 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-415.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 3.8 %·m is below.

Negative factors

  • 1.4 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.40”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 134Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
134
Grade Unit
g/t
Intercept
1.2 m
True Width
1.05 m
From
412.6 m
To
413.8 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-413.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 134 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 160.8 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“134”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.05

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 0.68Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.68
Grade Unit
g/t
Intercept
1.2 m
True Width
1.05 m
From
412.6 m
To
413.8 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-413.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.68 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 0.68 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.68”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.05

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 0.56Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.56
Grade Unit
%
Intercept
1.2 m
True Width
1.05 m
From
412.6 m
To
413.8 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-413.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.56 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.7 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.56”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.05

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 0.97Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.97
Grade Unit
%
Intercept
1.2 m
True Width
1.05 m
From
412.6 m
To
413.8 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-413.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.97 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.2 %·m is below.

Negative factors

  • 0.97 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.97”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.05

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 2.44Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.44
Grade Unit
%
Intercept
1.2 m
True Width
1.05 m
From
412.6 m
To
413.8 m
Intercept Depth
412.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.6-413.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.44 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.44”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.05

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 343Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
343
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
412.9 m
To
413.2 m
Intercept Depth
412.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.9-413.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
734
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 343 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 102.9 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 343 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“343”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 1.31Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.31
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
412.9 m
To
413.2 m
Intercept Depth
412.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.9-413.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
734
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.31 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.

Negative factors

  • 1.31 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.31”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 1.58Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.58
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
412.9 m
To
413.2 m
Intercept Depth
412.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.9-413.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
734
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.58 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.58 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.58”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 1.28Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.28
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
412.9 m
To
413.2 m
Intercept Depth
412.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.9-413.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
734
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.28 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.28”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 4.8Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
4.8
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
412.9 m
To
413.2 m
Intercept Depth
412.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:412.9-413.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
734
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 4.8 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 1.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.80”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · silverGrade: 400Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
400
Grade Unit
g/t
Intercept
0.6 m
True Width
0.5 m
From
418.3 m
To
418.9 m
Intercept Depth
418.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:418.3-418.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
496
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 400 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 240.0 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 400 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“400”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · goldGrade: 0.33Grade Unit: g/tIntercept: 0.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.33
Grade Unit
g/t
Intercept
0.6 m
True Width
0.5 m
From
418.3 m
To
418.9 m
Intercept Depth
418.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:418.3-418.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
496
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-01-28T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.33 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.33”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · copperGrade: 0.24Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.24
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
418.3 m
To
418.9 m
Intercept Depth
418.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:418.3-418.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
496
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.24 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.24”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · leadGrade: 0.63Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.63
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
418.3 m
To
418.9 m
Intercept Depth
418.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:418.3-418.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
496
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.63 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.63 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.63”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-239Alamos · zincGrade: 1.43Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-239
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.43
Grade Unit
%
Intercept
0.6 m
True Width
0.5 m
From
418.3 m
To
418.9 m
Intercept Depth
418.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-239:418.3-418.9
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
496
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.43 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.9 %·m is below.

Negative factors

  • 1.43 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.43”

Context: AL26-239

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-240Alamos · silverGrade: 57.8Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-240
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
57.8
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
459.4 m
To
459.7 m
Intercept Depth
459.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-240:459.4-459.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
145
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 57.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 17.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“57.8”

Context: AL26-240

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-240Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-240
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.3 m
True Width
0.25 m
From
459.4 m
To
459.7 m
Intercept Depth
459.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-240:459.4-459.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
145
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-240

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-240Alamos · copperGrade: 0.09Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-240
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.09
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
459.4 m
To
459.7 m
Intercept Depth
459.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-240:459.4-459.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
145
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.09 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: AL26-240

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-240Alamos · leadGrade: 1Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-240
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
459.4 m
To
459.7 m
Intercept Depth
459.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-240:459.4-459.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
145
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.00”

Context: AL26-240

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-240Alamos · zincGrade: 2.41Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-240
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.41
Grade Unit
%
Intercept
0.3 m
True Width
0.25 m
From
459.4 m
To
459.7 m
Intercept Depth
459.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-240:459.4-459.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
145
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.41 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 0.7 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.41”

Context: AL26-240

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · silverGrade: 159Grade Unit: g/tIntercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
159
Grade Unit
g/t
Intercept
3.2 m
True Width
2.75 m
From
295 m
To
298.2 m
Intercept Depth
295 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:295-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 159 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 508.8 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“159”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · goldGrade: 0.07Grade Unit: g/tIntercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
3.2 m
True Width
2.75 m
From
295 m
To
298.2 m
Intercept Depth
295 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:295-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.07 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · copperGrade: 0.15Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.15
Grade Unit
%
Intercept
3.2 m
True Width
2.75 m
From
295 m
To
298.2 m
Intercept Depth
295 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:295-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below.

Negative factors

  • 0.15 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · leadGrade: 0.29Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.29
Grade Unit
%
Intercept
3.2 m
True Width
2.75 m
From
295 m
To
298.2 m
Intercept Depth
295 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:295-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.9 %·m is below.

Negative factors

  • 0.29 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.29”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · zincGrade: 0.61Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.61
Grade Unit
%
Intercept
3.2 m
True Width
2.75 m
From
295 m
To
298.2 m
Intercept Depth
295 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:295-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.61 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.0 %·m is below.

Negative factors

  • 0.61 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.61”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · silverGrade: 231Grade Unit: g/tIntercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
231
Grade Unit
g/t
Intercept
1.75 m
True Width
1.5 m
From
296.45 m
To
298.2 m
Intercept Depth
296.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:296.45-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
286
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 231 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 404.3 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 231 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“231”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · goldGrade: 0.11Grade Unit: g/tIntercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1.75 m
True Width
1.5 m
From
296.45 m
To
298.2 m
Intercept Depth
296.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:296.45-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
286
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.11 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · copperGrade: 0.18Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
%
Intercept
1.75 m
True Width
1.5 m
From
296.45 m
To
298.2 m
Intercept Depth
296.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:296.45-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
286
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.18 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · leadGrade: 0.43Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.43
Grade Unit
%
Intercept
1.75 m
True Width
1.5 m
From
296.45 m
To
298.2 m
Intercept Depth
296.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:296.45-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
286
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.8 %·m is below.

Negative factors

  • 0.43 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.43”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · zincGrade: 0.89Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.89
Grade Unit
%
Intercept
1.75 m
True Width
1.5 m
From
296.45 m
To
298.2 m
Intercept Depth
296.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:296.45-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
286
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.89 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.6 %·m is below.

Negative factors

  • 0.89 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.89”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · silverGrade: 355Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
355
Grade Unit
g/t
Intercept
0.5 m
True Width
0.43 m
From
297.7 m
To
298.2 m
Intercept Depth
297.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:297.7-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 355 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 177.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 355 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“355”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · goldGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
0.5 m
True Width
0.43 m
From
297.7 m
To
298.2 m
Intercept Depth
297.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:297.7-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.16 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · copperGrade: 0.16Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
%
Intercept
0.5 m
True Width
0.43 m
From
297.7 m
To
298.2 m
Intercept Depth
297.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:297.7-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.16 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · leadGrade: 0.46Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.46
Grade Unit
%
Intercept
0.5 m
True Width
0.43 m
From
297.7 m
To
298.2 m
Intercept Depth
297.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:297.7-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.46 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.46 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.46”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-242Alamos · zincGrade: 0.62Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-242
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.62
Grade Unit
%
Intercept
0.5 m
True Width
0.43 m
From
297.7 m
To
298.2 m
Intercept Depth
297.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-242:297.7-298.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.62 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.62 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.62”

Context: AL26-242

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-245Alamos · silverGrade: 99Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-245
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
99
Grade Unit
g/t
Intercept
0.55 m
True Width
0.45 m
From
289.95 m
To
290.5 m
Intercept Depth
289.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-245:289.95-290.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
174
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 99 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 54.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“99”

Context: AL26-245

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-245Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-245
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.55 m
True Width
0.45 m
From
289.95 m
To
290.5 m
Intercept Depth
289.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-245:289.95-290.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
174
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-245

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-245Alamos · copperGrade: 0.25Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-245
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.55 m
True Width
0.45 m
From
289.95 m
To
290.5 m
Intercept Depth
289.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-245:289.95-290.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
174
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.25”

Context: AL26-245

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-245Alamos · leadGrade: 0.39Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-245
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.39
Grade Unit
%
Intercept
0.55 m
True Width
0.45 m
From
289.95 m
To
290.5 m
Intercept Depth
289.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-245:289.95-290.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
174
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.39 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.39”

Context: AL26-245

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-245Alamos · zincGrade: 1.84Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-245
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.84
Grade Unit
%
Intercept
0.55 m
True Width
0.45 m
From
289.95 m
To
290.5 m
Intercept Depth
289.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-245:289.95-290.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
174
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.84 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.0 %·m is below.

Negative factors

  • 1.84 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.84”

Context: AL26-245

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · silverGrade: 180Grade Unit: g/tIntercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
180
Grade Unit
g/t
Intercept
1.75 m
True Width
1.25 m
From
143.05 m
To
144.8 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-144.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 180 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 315.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“180”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.75 m
True Width
1.25 m
From
143.05 m
To
144.8 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-144.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · copperGrade: 0.22Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.22
Grade Unit
%
Intercept
1.75 m
True Width
1.25 m
From
143.05 m
To
144.8 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-144.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.22 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.22”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · leadGrade: 0.4Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.4
Grade Unit
%
Intercept
1.75 m
True Width
1.25 m
From
143.05 m
To
144.8 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-144.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.7 %·m is below.

Negative factors

  • 0.4 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.40”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · zincGrade: 0.6Grade Unit: %Intercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.6
Grade Unit
%
Intercept
1.75 m
True Width
1.25 m
From
143.05 m
To
144.8 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-144.8
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.1 %·m is below.

Negative factors

  • 0.6 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.60”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.25

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · silverGrade: 303Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
303
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
143.05 m
To
143.45 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-143.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
375
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 303 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 121.2 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 303 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“303”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · goldGrade: 0.05Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
143.05 m
To
143.45 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-143.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
375
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.05 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · copperGrade: 0.35Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.35
Grade Unit
%
Intercept
0.4 m
True Width
0.3 m
From
143.05 m
To
143.45 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-143.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
375
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.35”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · leadGrade: 0.5Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.5
Grade Unit
%
Intercept
0.4 m
True Width
0.3 m
From
143.05 m
To
143.45 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-143.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
375
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.5 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.50”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · zincGrade: 1.2Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.2
Grade Unit
%
Intercept
0.4 m
True Width
0.3 m
From
143.05 m
To
143.45 m
Intercept Depth
143.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:143.05-143.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
375
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.5 %·m is below.

Negative factors

  • 1.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.20”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · silverGrade: 237Grade Unit: g/tIntercept: 3.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
237
Grade Unit
g/t
Intercept
3.4 m
True Width
2.5 m
From
394.1 m
To
397.5 m
Intercept Depth
394.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.1-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
397
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 237 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 805.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 237 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“237”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · goldGrade: 0.2Grade Unit: g/tIntercept: 3.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
3.4 m
True Width
2.5 m
From
394.1 m
To
397.5 m
Intercept Depth
394.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.1-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
397
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.20”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · copperGrade: 0.95Grade Unit: %Intercept: 3.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.95
Grade Unit
%
Intercept
3.4 m
True Width
2.5 m
From
394.1 m
To
397.5 m
Intercept Depth
394.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.1-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
397
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.95 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.95”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · leadGrade: 0.8Grade Unit: %Intercept: 3.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.8
Grade Unit
%
Intercept
3.4 m
True Width
2.5 m
From
394.1 m
To
397.5 m
Intercept Depth
394.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.1-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
397
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.7 %·m is below.

Negative factors

  • 0.8 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.80”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · zincGrade: 1.87Grade Unit: %Intercept: 3.4 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.87
Grade Unit
%
Intercept
3.4 m
True Width
2.5 m
From
394.1 m
To
397.5 m
Intercept Depth
394.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.1-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
397
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.87 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 6.4 %·m is below.

Negative factors

  • 1.87 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.87”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · silverGrade: 1135Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1135
Grade Unit
g/t
Intercept
0.3 m
True Width
0.2 m
From
394.85 m
To
395.15 m
Intercept Depth
394.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.85-395.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1433
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1135 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 340.5 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1135 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1135”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · goldGrade: 0.23Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.23
Grade Unit
g/t
Intercept
0.3 m
True Width
0.2 m
From
394.85 m
To
395.15 m
Intercept Depth
394.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.85-395.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1433
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.23 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.23”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · copperGrade: 2.26Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.26
Grade Unit
%
Intercept
0.3 m
True Width
0.2 m
From
394.85 m
To
395.15 m
Intercept Depth
394.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.85-395.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1433
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.26 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.7 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.26 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.26”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · leadGrade: 1.42Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.42
Grade Unit
%
Intercept
0.3 m
True Width
0.2 m
From
394.85 m
To
395.15 m
Intercept Depth
394.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.85-395.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1433
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.42 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.42”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · zincGrade: 2.36Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.36
Grade Unit
%
Intercept
0.3 m
True Width
0.2 m
From
394.85 m
To
395.15 m
Intercept Depth
394.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:394.85-395.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1433
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.36 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 0.7 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.36”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · silverGrade: 262Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
262
Grade Unit
g/t
Intercept
1.3 m
True Width
1 m
From
396.2 m
To
397.5 m
Intercept Depth
396.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:396.2-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
530
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 262 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 340.6 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 262 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“262”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · goldGrade: 0.33Grade Unit: g/tIntercept: 1.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.33
Grade Unit
g/t
Intercept
1.3 m
True Width
1 m
From
396.2 m
To
397.5 m
Intercept Depth
396.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:396.2-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
530
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-01-28T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.

Negative factors

  • 0.33 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.33”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · copperGrade: 1.63Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.63
Grade Unit
%
Intercept
1.3 m
True Width
1 m
From
396.2 m
To
397.5 m
Intercept Depth
396.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:396.2-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
530
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.63 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.1 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.63 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.63”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · leadGrade: 1.43Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.43
Grade Unit
%
Intercept
1.3 m
True Width
1 m
From
396.2 m
To
397.5 m
Intercept Depth
396.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:396.2-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
530
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.43 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.43”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-246Alamos · zincGrade: 3.02Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AL26-246
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.02
Grade Unit
%
Intercept
1.3 m
True Width
1 m
From
396.2 m
To
397.5 m
Intercept Depth
396.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-246:396.2-397.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
530
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.02 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 3.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.02”

Context: AL26-246

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 120Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
120
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
160.85 m
To
161.15 m
Intercept Depth
160.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:160.85-161.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 120 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 36.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“120”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.3 m
True Width
0.28 m
From
160.85 m
To
161.15 m
Intercept Depth
160.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:160.85-161.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.18Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
160.85 m
To
161.15 m
Intercept Depth
160.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:160.85-161.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.18 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.3Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
160.85 m
To
161.15 m
Intercept Depth
160.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:160.85-161.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.3 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.30”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 0.64Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.64
Grade Unit
%
Intercept
0.3 m
True Width
0.28 m
From
160.85 m
To
161.15 m
Intercept Depth
160.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:160.85-161.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.64 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.64 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.64”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 621Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
621
Grade Unit
g/t
Intercept
0.65 m
True Width
0.6 m
From
211.1 m
To
211.75 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:211.1-211.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
837
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 621 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 403.7 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 621 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“621”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.18Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
0.65 m
True Width
0.6 m
From
211.1 m
To
211.75 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:211.1-211.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
837
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.18 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.92Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.92
Grade Unit
%
Intercept
0.65 m
True Width
0.6 m
From
211.1 m
To
211.75 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:211.1-211.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
837
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.92 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.6 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.92”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 1.63Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.63
Grade Unit
%
Intercept
0.65 m
True Width
0.6 m
From
211.1 m
To
211.75 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:211.1-211.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
837
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.63 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.63”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 3.72Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.72
Grade Unit
%
Intercept
0.65 m
True Width
0.6 m
From
211.1 m
To
211.75 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:211.1-211.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
837
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.72 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.72”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 223Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
223
Grade Unit
g/t
Intercept
1.5 m
True Width
1.35 m
From
296.2 m
To
297.7 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-297.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
243
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 223 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 334.5 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 223 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“223”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
1.5 m
True Width
1.35 m
From
296.2 m
To
297.7 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-297.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
243
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.14Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.14
Grade Unit
%
Intercept
1.5 m
True Width
1.35 m
From
296.2 m
To
297.7 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-297.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
243
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.14 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.14”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.16Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
%
Intercept
1.5 m
True Width
1.35 m
From
296.2 m
To
297.7 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-297.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
243
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.16 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 0.16Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
%
Intercept
1.5 m
True Width
1.35 m
From
296.2 m
To
297.7 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-297.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
243
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.16 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 443Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
443
Grade Unit
g/t
Intercept
0.4 m
True Width
0.35 m
From
296.2 m
To
296.6 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-296.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
471
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 443 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 177.2 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 443 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“443”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.4 m
True Width
0.35 m
From
296.2 m
To
296.6 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-296.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
471
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.25Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.4 m
True Width
0.35 m
From
296.2 m
To
296.6 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-296.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
471
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.25”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.16Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
%
Intercept
0.4 m
True Width
0.35 m
From
296.2 m
To
296.6 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-296.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
471
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.16 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 0.06Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
%
Intercept
0.4 m
True Width
0.35 m
From
296.2 m
To
296.6 m
Intercept Depth
296.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:296.2-296.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
471
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.06 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 284Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
284
Grade Unit
g/t
Intercept
0.35 m
True Width
0.3 m
From
342.05 m
To
342.4 m
Intercept Depth
342.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:342.05-342.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
361
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 284 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 99.4 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 284 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“284”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.35 m
True Width
0.3 m
From
342.05 m
To
342.4 m
Intercept Depth
342.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:342.05-342.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
361
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.3Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
342.05 m
To
342.4 m
Intercept Depth
342.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:342.05-342.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
361
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.30”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.62Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.62
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
342.05 m
To
342.4 m
Intercept Depth
342.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:342.05-342.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
361
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.62 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.62 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.62”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 1.59Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.59
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
342.05 m
To
342.4 m
Intercept Depth
342.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:342.05-342.4
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
361
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.59 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 1.59 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.59”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 375Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
375
Grade Unit
g/t
Intercept
0.8 m
True Width
0.75 m
From
385.2 m
To
386 m
Intercept Depth
385.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.2-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 375 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 300.0 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 375 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“375”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.09Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.09
Grade Unit
g/t
Intercept
0.8 m
True Width
0.75 m
From
385.2 m
To
386 m
Intercept Depth
385.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.2-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.09 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.78Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.78
Grade Unit
%
Intercept
0.8 m
True Width
0.75 m
From
385.2 m
To
386 m
Intercept Depth
385.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.2-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.78 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.6 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.78”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.25Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.8 m
True Width
0.75 m
From
385.2 m
To
386 m
Intercept Depth
385.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.2-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.25 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.25”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 0.95Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.95
Grade Unit
%
Intercept
0.8 m
True Width
0.75 m
From
385.2 m
To
386 m
Intercept Depth
385.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.2-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.95 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.8 %·m is below.

Negative factors

  • 0.95 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.95”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 752Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
752
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
385.65 m
To
386 m
Intercept Depth
385.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.65-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
952
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 752 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 263.2 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 752 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“752”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.18Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
385.65 m
To
386 m
Intercept Depth
385.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.65-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
952
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.18 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 1.56Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.56
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
385.65 m
To
386 m
Intercept Depth
385.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.65-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
952
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.56 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.56 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.56”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.42Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.42
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
385.65 m
To
386 m
Intercept Depth
385.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.65-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
952
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.42 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.42 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.42”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 1.8Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.8
Grade Unit
%
Intercept
0.35 m
True Width
0.32 m
From
385.65 m
To
386 m
Intercept Depth
385.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:385.65-386
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
952
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.8 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 1.8 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.80”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 181Grade Unit: g/tIntercept: 5.05 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
181
Grade Unit
g/t
Intercept
5.05 m
True Width
4.55 m
From
411 m
To
416.05 m
Intercept Depth
411 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:411-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
248
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 181 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 914.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“181”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 5.05 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
5.05 m
True Width
4.55 m
From
411 m
To
416.05 m
Intercept Depth
411 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:411-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
248
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.35Grade Unit: %Intercept: 5.05 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.35
Grade Unit
%
Intercept
5.05 m
True Width
4.55 m
From
411 m
To
416.05 m
Intercept Depth
411 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:411-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
248
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.8 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.35”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.57Grade Unit: %Intercept: 5.05 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.57
Grade Unit
%
Intercept
5.05 m
True Width
4.55 m
From
411 m
To
416.05 m
Intercept Depth
411 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:411-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
248
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.9 %·m is below.

Negative factors

  • 0.57 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.57”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 1Grade Unit: %Intercept: 5.05 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1
Grade Unit
%
Intercept
5.05 m
True Width
4.55 m
From
411 m
To
416.05 m
Intercept Depth
411 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:411-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
248
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 5.0 %·m is below.

Negative factors

  • 1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.00”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 336Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
336
Grade Unit
g/t
Intercept
1.7 m
True Width
1.55 m
From
412.3 m
To
414 m
Intercept Depth
412.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:412.3-414
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
464
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 336 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 571.2 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 336 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“336”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.04Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
1.7 m
True Width
1.55 m
From
412.3 m
To
414 m
Intercept Depth
412.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:412.3-414
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
464
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.04 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.69Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.69
Grade Unit
%
Intercept
1.7 m
True Width
1.55 m
From
412.3 m
To
414 m
Intercept Depth
412.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:412.3-414
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
464
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.69 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.69”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 0.8Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.8
Grade Unit
%
Intercept
1.7 m
True Width
1.55 m
From
412.3 m
To
414 m
Intercept Depth
412.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:412.3-414
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
464
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.4 %·m is below.

Negative factors

  • 0.8 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.80”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 2.06Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.06
Grade Unit
%
Intercept
1.7 m
True Width
1.55 m
From
412.3 m
To
414 m
Intercept Depth
412.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:412.3-414
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
464
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.06 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 3.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.06”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.55

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · silverGrade: 311Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
311
Grade Unit
g/t
Intercept
0.5 m
True Width
0.45 m
From
415.55 m
To
416.05 m
Intercept Depth
415.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:415.55-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
390
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 311 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 155.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 311 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“311”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · goldGrade: 0.06Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
g/t
Intercept
0.5 m
True Width
0.45 m
From
415.55 m
To
416.05 m
Intercept Depth
415.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:415.55-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
390
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.06 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · copperGrade: 0.47Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.47
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
415.55 m
To
416.05 m
Intercept Depth
415.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:415.55-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
390
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.47”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · leadGrade: 1.24Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.24
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
415.55 m
To
416.05 m
Intercept Depth
415.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:415.55-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
390
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.24 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 0.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.24”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-247Alamos · zincGrade: 0.37Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-247
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.37
Grade Unit
%
Intercept
0.5 m
True Width
0.45 m
From
415.55 m
To
416.05 m
Intercept Depth
415.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-247:415.55-416.05
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
390
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.37 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.37”

Context: AL26-247

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-252Alamos · silverGrade: 84Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AL26-252
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
84
Grade Unit
g/t
Intercept
1.35 m
True Width
0.95 m
From
135.8 m
To
137.15 m
Intercept Depth
135.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-252:135.8-137.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
176
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 84 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 113.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“84”

Context: AL26-252

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-252Alamos · goldGrade: 0.3Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AL26-252
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
1.35 m
True Width
0.95 m
From
135.8 m
To
137.15 m
Intercept Depth
135.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-252:135.8-137.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
176
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.

Negative factors

  • 0.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.30”

Context: AL26-252

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-252Alamos · copperGrade: 0.31Grade Unit: %Intercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AL26-252
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.31
Grade Unit
%
Intercept
1.35 m
True Width
0.95 m
From
135.8 m
To
137.15 m
Intercept Depth
135.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-252:135.8-137.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
176
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.31”

Context: AL26-252

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-252Alamos · leadGrade: 0.5Grade Unit: %Intercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AL26-252
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.5
Grade Unit
%
Intercept
1.35 m
True Width
0.95 m
From
135.8 m
To
137.15 m
Intercept Depth
135.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-252:135.8-137.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
176
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.7 %·m is below.

Negative factors

  • 0.5 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.50”

Context: AL26-252

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-252Alamos · zincGrade: 1.23Grade Unit: %Intercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AL26-252
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.23
Grade Unit
%
Intercept
1.35 m
True Width
0.95 m
From
135.8 m
To
137.15 m
Intercept Depth
135.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-252:135.8-137.15
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
176
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.23 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.7 %·m is below.

Negative factors

  • 1.23 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.23”

Context: AL26-252

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · silverGrade: 112Grade Unit: g/tIntercept: 3.15 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
112
Grade Unit
g/t
Intercept
3.15 m
True Width
2.8 m
From
352.85 m
To
356 m
Intercept Depth
352.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:352.85-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
180
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 112 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 352.8 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“112”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · goldGrade: 0.04Grade Unit: g/tIntercept: 3.15 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
3.15 m
True Width
2.8 m
From
352.85 m
To
356 m
Intercept Depth
352.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:352.85-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
180
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.04 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · copperGrade: 0.34Grade Unit: %Intercept: 3.15 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.34
Grade Unit
%
Intercept
3.15 m
True Width
2.8 m
From
352.85 m
To
356 m
Intercept Depth
352.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:352.85-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
180
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.34”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · leadGrade: 0.74Grade Unit: %Intercept: 3.15 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.74
Grade Unit
%
Intercept
3.15 m
True Width
2.8 m
From
352.85 m
To
356 m
Intercept Depth
352.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:352.85-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
180
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.74 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.3 %·m is below.

Negative factors

  • 0.74 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.74”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · zincGrade: 0.86Grade Unit: %Intercept: 3.15 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.86
Grade Unit
%
Intercept
3.15 m
True Width
2.8 m
From
352.85 m
To
356 m
Intercept Depth
352.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:352.85-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
180
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.86 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.7 %·m is below.

Negative factors

  • 0.86 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.86”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · silverGrade: 185Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
185
Grade Unit
g/t
Intercept
0.55 m
True Width
0.5 m
From
353.75 m
To
354.3 m
Intercept Depth
353.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:353.75-354.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
298
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 185 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 101.8 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“185”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.55 m
True Width
0.5 m
From
353.75 m
To
354.3 m
Intercept Depth
353.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:353.75-354.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
298
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · copperGrade: 0.8Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.8
Grade Unit
%
Intercept
0.55 m
True Width
0.5 m
From
353.75 m
To
354.3 m
Intercept Depth
353.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:353.75-354.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
298
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.80”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · leadGrade: 0.82Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.82
Grade Unit
%
Intercept
0.55 m
True Width
0.5 m
From
353.75 m
To
354.3 m
Intercept Depth
353.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:353.75-354.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
298
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.82 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.5 %·m is below.

Negative factors

  • 0.82 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.82”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · zincGrade: 1.14Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.14
Grade Unit
%
Intercept
0.55 m
True Width
0.5 m
From
353.75 m
To
354.3 m
Intercept Depth
353.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:353.75-354.3
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
298
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.14 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 1.14 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.14”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · silverGrade: 104Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
104
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
355.7 m
To
356 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:355.7-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
324
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 104 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 31.2 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“104”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · goldGrade: 0.27Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
0.3 m
True Width
0.27 m
From
355.7 m
To
356 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:355.7-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
324
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.27 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · copperGrade: 0.45Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.45
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
355.7 m
To
356 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:355.7-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
324
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.45”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · leadGrade: 4.2Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
4.2
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
355.7 m
To
356 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:355.7-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
324
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 1.3 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.20”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · zincGrade: 3.05Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.05
Grade Unit
%
Intercept
0.3 m
True Width
0.27 m
From
355.7 m
To
356 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:355.7-356
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
324
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.05 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 0.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.05”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · silverGrade: 75Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
75
Grade Unit
g/t
Intercept
1.9 m
True Width
1.7 m
From
371.8 m
To
373.7 m
Intercept Depth
371.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:371.8-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
136
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 75 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 142.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“75”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · goldGrade: 0.06Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
g/t
Intercept
1.9 m
True Width
1.7 m
From
371.8 m
To
373.7 m
Intercept Depth
371.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:371.8-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
136
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.06 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · copperGrade: 0.47Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.47
Grade Unit
%
Intercept
1.9 m
True Width
1.7 m
From
371.8 m
To
373.7 m
Intercept Depth
371.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:371.8-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
136
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.47”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · leadGrade: 0.41Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.41
Grade Unit
%
Intercept
1.9 m
True Width
1.7 m
From
371.8 m
To
373.7 m
Intercept Depth
371.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:371.8-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
136
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.41 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.8 %·m is below.

Negative factors

  • 0.41 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.41”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · zincGrade: 0.29Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.29
Grade Unit
%
Intercept
1.9 m
True Width
1.7 m
From
371.8 m
To
373.7 m
Intercept Depth
371.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:371.8-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
136
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 0.29 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.29”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · silverGrade: 184Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
184
Grade Unit
g/t
Intercept
0.4 m
True Width
0.37 m
From
373.3 m
To
373.7 m
Intercept Depth
373.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:373.3-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
337
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 184 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 73.6 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“184”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · goldGrade: 0.11Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
0.4 m
True Width
0.37 m
From
373.3 m
To
373.7 m
Intercept Depth
373.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:373.3-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
337
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.11 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · copperGrade: 1.32Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.32
Grade Unit
%
Intercept
0.4 m
True Width
0.37 m
From
373.3 m
To
373.7 m
Intercept Depth
373.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:373.3-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
337
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.32 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.32 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.32”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · leadGrade: 0.66Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.66
Grade Unit
%
Intercept
0.4 m
True Width
0.37 m
From
373.3 m
To
373.7 m
Intercept Depth
373.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:373.3-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
337
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.66 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.66 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.66”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-253Alamos · zincGrade: 0.72Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-253
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.72
Grade Unit
%
Intercept
0.4 m
True Width
0.37 m
From
373.3 m
To
373.7 m
Intercept Depth
373.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-253:373.3-373.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
337
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.72 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.72 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.72”

Context: AL26-253

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · silverGrade: 235Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
235
Grade Unit
g/t
Intercept
0.95 m
True Width
0.75 m
From
167.65 m
To
168.6 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 235 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 223.3 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 235 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“235”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.95 m
True Width
0.75 m
From
167.65 m
To
168.6 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · copperGrade: 0.2Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.95 m
True Width
0.75 m
From
167.65 m
To
168.6 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.20”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · leadGrade: 0.11Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.95 m
True Width
0.75 m
From
167.65 m
To
168.6 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · zincGrade: 0.07Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.95 m
True Width
0.75 m
From
167.65 m
To
168.6 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.6
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · silverGrade: 374Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
374
Grade Unit
g/t
Intercept
0.45 m
True Width
0.35 m
From
167.65 m
To
168.1 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 374 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 168.3 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 374 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“374”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.45 m
True Width
0.35 m
From
167.65 m
To
168.1 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · copperGrade: 0.3Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.45 m
True Width
0.35 m
From
167.65 m
To
168.1 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.30”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · leadGrade: 0.18Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.18
Grade Unit
%
Intercept
0.45 m
True Width
0.35 m
From
167.65 m
To
168.1 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.18 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-255Alamos · zincGrade: 0.1Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-255
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.45 m
True Width
0.35 m
From
167.65 m
To
168.1 m
Intercept Depth
167.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-255:167.65-168.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
406
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: AL26-255

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.35

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-231Alamos · silverGrade: 74Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AL26-231
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
74
Grade Unit
g/t
Intercept
1.1 m
True Width
0.95 m
From
310.4 m
To
311.5 m
Intercept Depth
310.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-231:310.4-311.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 74 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 81.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“74”

Context: AL26-231

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-231Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AL26-231
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.1 m
True Width
0.95 m
From
310.4 m
To
311.5 m
Intercept Depth
310.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-231:310.4-311.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-231

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-231Alamos · copperGrade: 0.34Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AL26-231
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.34
Grade Unit
%
Intercept
1.1 m
True Width
0.95 m
From
310.4 m
To
311.5 m
Intercept Depth
310.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-231:310.4-311.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.34”

Context: AL26-231

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-231Alamos · leadGrade: 0.12Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AL26-231
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.1 m
True Width
0.95 m
From
310.4 m
To
311.5 m
Intercept Depth
310.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-231:310.4-311.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.12 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.12”

Context: AL26-231

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-231Alamos · zincGrade: 0.03Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AL26-231
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
%
Intercept
1.1 m
True Width
0.95 m
From
310.4 m
To
311.5 m
Intercept Depth
310.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-231:310.4-311.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-231

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-238Alamos · silverGrade: 93.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-238
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
93.4
Grade Unit
g/t
Intercept
0.6 m
True Width
0.56 m
From
150.15 m
To
150.75 m
Intercept Depth
150.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-238:150.15-150.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
106
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 93.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 56.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“93.4”

Context: AL26-238

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.56

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-238Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-238
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.6 m
True Width
0.56 m
From
150.15 m
To
150.75 m
Intercept Depth
150.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-238:150.15-150.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
106
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: AL26-238

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.56

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-238Alamos · copperGrade: 0.1Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-238
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.6 m
True Width
0.56 m
From
150.15 m
To
150.75 m
Intercept Depth
150.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-238:150.15-150.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
106
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: AL26-238

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.56

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-238Alamos · leadGrade: 0.07Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-238
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.6 m
True Width
0.56 m
From
150.15 m
To
150.75 m
Intercept Depth
150.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-238:150.15-150.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
106
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.07 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: AL26-238

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.56

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-238Alamos · zincGrade: 0.08Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AL26-238
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.08
Grade Unit
%
Intercept
0.6 m
True Width
0.56 m
From
150.15 m
To
150.75 m
Intercept Depth
150.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-238:150.15-150.75
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
106
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.08 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.08”

Context: AL26-238

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.56

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · silverGrade: 142Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
142
Grade Unit
g/t
Intercept
5 m
True Width
4 m
From
210.5 m
To
215.5 m
Intercept Depth
210.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:210.5-215.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
171
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 142 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 710.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“142”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
5 m
True Width
4 m
From
210.5 m
To
215.5 m
Intercept Depth
210.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:210.5-215.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
171
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · copperGrade: 0.16Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.16
Grade Unit
%
Intercept
5 m
True Width
4 m
From
210.5 m
To
215.5 m
Intercept Depth
210.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:210.5-215.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
171
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.8 %·m is below.

Negative factors

  • 0.16 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · leadGrade: 0.39Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.39
Grade Unit
%
Intercept
5 m
True Width
4 m
From
210.5 m
To
215.5 m
Intercept Depth
210.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:210.5-215.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
171
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.0 %·m is below.

Negative factors

  • 0.39 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.39”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · zincGrade: 0.26Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.26
Grade Unit
%
Intercept
5 m
True Width
4 m
From
210.5 m
To
215.5 m
Intercept Depth
210.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:210.5-215.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
171
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.26 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.3 %·m is below.

Negative factors

  • 0.26 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.26”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · silverGrade: 284Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
284
Grade Unit
g/t
Intercept
0.4 m
True Width
0.33 m
From
211.1 m
To
211.5 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:211.1-211.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
343
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 284 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 113.6 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 284 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“284”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.33

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.4 m
True Width
0.33 m
From
211.1 m
To
211.5 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:211.1-211.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
343
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.33

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · copperGrade: 0.51Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.51
Grade Unit
%
Intercept
0.4 m
True Width
0.33 m
From
211.1 m
To
211.5 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:211.1-211.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
343
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.51 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.51”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.33

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · leadGrade: 0.5Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.5
Grade Unit
%
Intercept
0.4 m
True Width
0.33 m
From
211.1 m
To
211.5 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:211.1-211.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
343
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.5 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.50”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.33

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-241Alamos · zincGrade: 0.15Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
AL26-241
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.15
Grade Unit
%
Intercept
0.4 m
True Width
0.33 m
From
211.1 m
To
211.5 m
Intercept Depth
211.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-241:211.1-211.5
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
343
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.15 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: AL26-241

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.33

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-244Alamos · silverGrade: 68.3Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-244
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
68.3
Grade Unit
g/t
Intercept
0.35 m
True Width
0.3 m
From
191.65 m
To
192 m
Intercept Depth
191.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-244:191.65-192
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 68.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 23.9 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“68.3”

Context: AL26-244

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-244Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-244
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.35 m
True Width
0.3 m
From
191.65 m
To
192 m
Intercept Depth
191.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-244:191.65-192
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-244

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-244Alamos · copperGrade: 0.06Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-244
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
191.65 m
To
192 m
Intercept Depth
191.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-244:191.65-192
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.06 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: AL26-244

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-244Alamos · leadGrade: 0.1Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-244
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
191.65 m
To
192 m
Intercept Depth
191.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-244:191.65-192
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: AL26-244

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-244Alamos · zincGrade: 0.04Grade Unit: %Intercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
AL26-244
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.04
Grade Unit
%
Intercept
0.35 m
True Width
0.3 m
From
191.65 m
To
192 m
Intercept Depth
191.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-244:191.65-192
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.04 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: AL26-244

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · silverGrade: 1103Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1103
Grade Unit
g/t
Intercept
0.9 m
True Width
0.85 m
From
162.8 m
To
163.7 m
Intercept Depth
162.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:162.8-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1469
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1103 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 992.7 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1103 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1103”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · goldGrade: 0.26Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.26
Grade Unit
g/t
Intercept
0.9 m
True Width
0.85 m
From
162.8 m
To
163.7 m
Intercept Depth
162.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:162.8-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1469
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.26 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.26 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.26”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · copperGrade: 2.42Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.42
Grade Unit
%
Intercept
0.9 m
True Width
0.85 m
From
162.8 m
To
163.7 m
Intercept Depth
162.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:162.8-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1469
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.42 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.2 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.42 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.42”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · leadGrade: 2.8Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.8
Grade Unit
%
Intercept
0.9 m
True Width
0.85 m
From
162.8 m
To
163.7 m
Intercept Depth
162.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:162.8-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1469
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 2.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.80”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · zincGrade: 3.35Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.35
Grade Unit
%
Intercept
0.9 m
True Width
0.85 m
From
162.8 m
To
163.7 m
Intercept Depth
162.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:162.8-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1469
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.35 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 3.0 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.35”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · silverGrade: 1910Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1910
Grade Unit
g/t
Intercept
0.5 m
True Width
0.48 m
From
163.2 m
To
163.7 m
Intercept Depth
163.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:163.2-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2425
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1910 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 955.0 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1910 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1910”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · goldGrade: 0.43Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.43
Grade Unit
g/t
Intercept
0.5 m
True Width
0.48 m
From
163.2 m
To
163.7 m
Intercept Depth
163.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:163.2-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2425
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.43 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.43”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · copperGrade: 3.9Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.9
Grade Unit
%
Intercept
0.5 m
True Width
0.48 m
From
163.2 m
To
163.7 m
Intercept Depth
163.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:163.2-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2425
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.9 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.9 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.9 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.90”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · leadGrade: 1.59Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.59
Grade Unit
%
Intercept
0.5 m
True Width
0.48 m
From
163.2 m
To
163.7 m
Intercept Depth
163.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:163.2-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2425
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.59 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 0.8 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.59”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-249Alamos · zincGrade: 4.71Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AL26-249
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
4.71
Grade Unit
%
Intercept
0.5 m
True Width
0.48 m
From
163.2 m
To
163.7 m
Intercept Depth
163.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-249:163.2-163.7
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2425
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 4.71 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.71”

Context: AL26-249

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-251Alamos · silverGrade: 18Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-251
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.65 m
True Width
0.5 m
From
146.9 m
To
147.55 m
Intercept Depth
146.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-251:146.9-147.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
30
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 18 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.7 g/t·m is below.

Negative factors

  • 18 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“18”

Context: AL26-251

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-251Alamos · goldGrade: 0Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-251
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.65 m
True Width
0.5 m
From
146.9 m
To
147.55 m
Intercept Depth
146.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-251:146.9-147.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
30
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: AL26-251

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-251Alamos · copperGrade: 0.14Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-251
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.14
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
146.9 m
To
147.55 m
Intercept Depth
146.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-251:146.9-147.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
30
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.14 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.14”

Context: AL26-251

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-251Alamos · leadGrade: 0Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-251
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
146.9 m
To
147.55 m
Intercept Depth
146.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-251:146.9-147.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
30
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: AL26-251

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-251Alamos · zincGrade: 0.01Grade Unit: %Intercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AL26-251
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.65 m
True Width
0.5 m
From
146.9 m
To
147.55 m
Intercept Depth
146.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-251:146.9-147.55
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
30
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AL26-251

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · silverGrade: 133Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
133
Grade Unit
g/t
Intercept
0.75 m
True Width
0.68 m
From
162.45 m
To
163.2 m
Intercept Depth
162.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:162.45-163.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
167
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 133 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 99.8 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“133”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · goldGrade: 0.02Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.02
Grade Unit
g/t
Intercept
0.75 m
True Width
0.68 m
From
162.45 m
To
163.2 m
Intercept Depth
162.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:162.45-163.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
167
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · copperGrade: 0.36Grade Unit: %Intercept: 0.75 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.36
Grade Unit
%
Intercept
0.75 m
True Width
0.68 m
From
162.45 m
To
163.2 m
Intercept Depth
162.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:162.45-163.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
167
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2026-08-25T00:00:00.000Z

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.3 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.36”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · leadGrade: 0.03Grade Unit: %Intercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
%
Intercept
0.75 m
True Width
0.68 m
From
162.45 m
To
163.2 m
Intercept Depth
162.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:162.45-163.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
167
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · zincGrade: 0.07Grade Unit: %Intercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.75 m
True Width
0.68 m
From
162.45 m
To
163.2 m
Intercept Depth
162.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:162.45-163.2
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
167
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · silverGrade: 83Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
83
Grade Unit
g/t
Intercept
1.8 m
True Width
1.65 m
From
275.65 m
To
277.45 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-277.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 83 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 149.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“83”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · goldGrade: 0.01Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
1.8 m
True Width
1.65 m
From
275.65 m
To
277.45 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-277.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · copperGrade: 0.06Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.06
Grade Unit
%
Intercept
1.8 m
True Width
1.65 m
From
275.65 m
To
277.45 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-277.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.06 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · leadGrade: 2.18Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
2.18
Grade Unit
%
Intercept
1.8 m
True Width
1.65 m
From
275.65 m
To
277.45 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-277.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 2.18 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 3.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.18”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · zincGrade: 1.15Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
1.15
Grade Unit
%
Intercept
1.8 m
True Width
1.65 m
From
275.65 m
To
277.45 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-277.45
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 1.15 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.1 %·m is below.

Negative factors

  • 1.15 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.15”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · silverGrade: 165Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
165
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
275.65 m
To
276.1 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-276.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
265
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 165 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 74.3 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“165”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · goldGrade: 0.03Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.45 m
True Width
0.4 m
From
275.65 m
To
276.1 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-276.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
265
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · copperGrade: 0.05Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.05
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
275.65 m
To
276.1 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-276.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
265
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.05 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · leadGrade: 3.58Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
3.58
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
275.65 m
To
276.1 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-276.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
265
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 3.58 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 1.6 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.58”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

AL26-254Alamos · zincGrade: 0.91Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
AL26-254
Project
Alamos
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MGG

Geometry

Grade
0.91
Grade Unit
%
Intercept
0.45 m
True Width
0.4 m
From
275.65 m
To
276.1 m
Intercept Depth
275.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AL26-254:275.65-276.1
Mining Method
underground

QA/QC

Laboratory
ALS Minerals
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
265
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: Expanded from assay table. 0.91 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.91 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.91”

Context: AL26-254

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Minaurum Resource Step-Out Drilling Returns: 3.40 m of 397 g/t AgEq at Europa Sur, 1.90 m of 323 g/t AgEq at Quintera, a"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.