MHC: Drilling at Spectre Delivers 6.10m at 3.18% Cu, 1.37g/t Au

Original announcement by asx on

Company
Manhattan Gold Corporation Limited
Ticker
MHC
Exchange
ASX
Region
Nunavut, Canada
Primary commodity
Copper
Secondary commodities
Gold, Silver, Zinc, Lead
Document categories
Drill results
Extracted
2026-10-05 22:35:04 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Manhattan Gold Corporation Limited reported strong polymetallic assay results from maiden drilling at its Spectre target within the Hook Lake Project in Nunavut, Canada. Hole SPC26001 delivered 6.10m at 3.18% Cu, 1.37g/t Au, 147.9g/t Ag, and 1.35% Zn, including a high-grade zinc zone of 3.05m at 29.50% Zn. SPC26002 confirmed mineralization 77m along strike, with both holes establishing Spectre as a significant VMS target and diversifying the company's metal exposure.

Reasoning: Maiden drilling at the Spectre VMS target delivered exceptional polymetallic grades, particularly for zinc and copper, exceeding expectations and establishing a new high-priority target for the Hook Lake Project.

Positive factors

  • High-grade polymetallic intercepts (Cu, Au, Ag, Zn, Pb) from maiden drilling.
  • Maiden drilling at Spectre exceeded expectations of both grade and thickness.
  • Established Spectre as a new significant VMS target, diversifying metal exposure for the Hook Lake Project.
  • Mineralization extended along strike (77m) and to vertical depth (86m).
  • Comprehensive QA/QC procedures and JORC compliance disclosed.
  • QP signed off on the exploration results.

Negative factors

  • Reported intervals are downhole lengths, and true widths are not known.
  • Drilling orientation for SPC26001 and SPC26008 was down-dip, potentially introducing sample bias and exaggerating apparent width.
  • Data spacing is not yet sufficient to establish geological or grade continuity for resource estimation.

Facts used in scoring: 105

Classification and evidence

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes extensive QA/QC disclosure in JORC Table 1 Section 1, detailing sample preparation, analytical methods, and insertion of blanks, standards, and field duplicates.

Evidence · text

“Quality control samples are inserted into the sample stream at a rate of 10% consisting of coarse blanks CDN BL-10T or OREAS C26e, certified reference material OREAS 236b and CDN-GS-1P5X, and field duplicates. These are assessed by MHC technical staff”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that reported intervals are drilled lengths and true thicknesses are not known, and that drilling was partly down-dip, which may exaggerate apparent width.

Evidence · text

“Reported intervals are drilled lengths not true thicknesses.”

Maiden Resourceneutral · Story-specific tag

First formal MRE for the project — establishes baseline but typically exploration-stage with high Inferred component.

Why it applies: The announcement describes the drilling as 'Maiden Drilling at Spectre' and refers to Spectre as a 'new exploration frontier'.

Evidence · text

“Maiden Drilling at Spectre Delivers 6.10m at 3.18% Copper, 1.37g/t Gold, 147.9g/t Silver, and 1.35% Zinc”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: Hole SPC26002 is reported to repeat mineralization '77m along strike' from SPC26001, indicating an extension of the mineralized zone.

Evidence · text

“SPC26002 repeats copper, gold, silver and zinc 77m along strike”

Extracted facts

Stored fact records: 105. Some facts used in scoring do not have a stored record.

Drill Results (105)

SPC26001Hook Lake · goldGrade: 0.146Grade Unit: g/tIntercept: 19.82 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.146
Grade Unit
g/t
Intercept
19.82 m
From
9.14 m
To
28.96 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:9.14-28.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.146 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.146”

Context: 19.82

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 6.2Grade Unit: g/tIntercept: 19.82 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
6.2
Grade Unit
g/t
Intercept
19.82 m
From
9.14 m
To
28.96 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:9.14-28.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (6.2 g/t vs VMS weak 30 g/t).

Evidence · table

“6.2”

Context: 19.82

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 0.043Grade Unit: %Intercept: 19.82 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.043
Grade Unit
%
Intercept
19.82 m
From
9.14 m
To
28.96 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:9.14-28.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the VMS weak threshold (0.043% vs 0.4%).

Evidence · table

“0.043”

Context: 19.82

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · leadGrade: 0.011Grade Unit: %Intercept: 19.82 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.011
Grade Unit
%
Intercept
19.82 m
From
9.14 m
To
28.96 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:9.14-28.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.011”

Context: 19.82

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 5.552Grade Unit: %Intercept: 19.82 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
5.552
Grade Unit
%
Intercept
19.82 m
From
9.14 m
To
28.96 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:9.14-28.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate zinc grade in a broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is moderate (5.552% vs VMS moderate 5%).

Evidence · table

“5.552”

Context: 19.82

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · goldGrade: 0.365Grade Unit: g/tIntercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.365
Grade Unit
g/t
Intercept
7.62 m
From
10.67 m
To
18.29 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.365 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.365”

Context: 7.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 12Grade Unit: g/tIntercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
12
Grade Unit
g/t
Intercept
7.62 m
From
10.67 m
To
18.29 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (12.0 g/t vs VMS weak 30 g/t).

Evidence · table

“12.0”

Context: 7.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 0.076Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.076
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the VMS weak threshold (0.076% vs 0.4%).

Evidence · table

“0.076”

Context: 7.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · leadGrade: 0.024Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.024
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.024”

Context: 7.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 13.982Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
13.982
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Strong zinc grade in a sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is strong (13.982% vs VMS strong 10%).

Evidence · table

“13.982”

Context: 7.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · goldGrade: 0.244Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.244
Grade Unit
g/t
Intercept
3.05 m
From
12.19 m
To
15.24 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a high-grade zinc sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.244 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.244”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 14.2Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
14.2
Grade Unit
g/t
Intercept
3.05 m
From
12.19 m
To
15.24 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a high-grade zinc sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (14.2 g/t vs VMS weak 30 g/t).

Evidence · table

“14.2”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 0.087Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.087
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a high-grade zinc sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the VMS weak threshold (0.087% vs 0.4%).

Evidence · table

“0.087”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · leadGrade: 0.041Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.041
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a high-grade zinc sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.041”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 29.5Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
29.5
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Exceptional zinc grade in a narrow sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is exceptional (29.500% vs VMS exceptional 18%).
  • Bonanza Intercept: Exceptionally high-grade zinc zone.

Evidence · table

“29.500”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: Zinc grade of 29.50% is well above the VMS exceptional threshold of 18%.

Evidence · table

“29.500”

Context: 3.05

SPC26001Hook Lake · goldGrade: 0.207Grade Unit: g/tIntercept: 82.3 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.207
Grade Unit
g/t
Intercept
82.3 m
From
38.1 m
To
120.4 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:38.1-120.4
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a very broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.207 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.207”

Context: 82.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 22.7Grade Unit: g/tIntercept: 82.3 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
22.7
Grade Unit
g/t
Intercept
82.3 m
From
38.1 m
To
120.4 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:38.1-120.4
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a very broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (22.7 g/t vs VMS weak 30 g/t).

Evidence · table

“22.7”

Context: 82.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 0.447Grade Unit: %Intercept: 82.3 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.447
Grade Unit
%
Intercept
82.3 m
From
38.1 m
To
120.4 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:38.1-120.4
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak copper grade in a very broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is weak (0.447% vs VMS weak 0.4%).

Evidence · table

“0.447”

Context: 82.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · leadGrade: 0.045Grade Unit: %Intercept: 82.3 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.045
Grade Unit
%
Intercept
82.3 m
From
38.1 m
To
120.4 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:38.1-120.4
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a very broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.045”

Context: 82.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 1.263Grade Unit: %Intercept: 82.3 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.263
Grade Unit
%
Intercept
82.3 m
From
38.1 m
To
120.4 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:38.1-120.4
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak zinc grade in a very broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is weak (1.263% vs VMS weak 2%).

Evidence · table

“1.263”

Context: 82.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · goldGrade: 0.804Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.804
Grade Unit
g/t
Intercept
19.81 m
From
42.67 m
To
62.48 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate gold grade in a significant sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Gold grade is moderate (0.804 g/t vs VMS moderate 1 g/t).

Evidence · table

“0.804”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 84.3Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
84.3
Grade Unit
g/t
Intercept
19.81 m
From
42.67 m
To
62.48 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate silver grade in a significant sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Silver grade is moderate (84.3 g/t vs VMS moderate 100 g/t).

Evidence · table

“84.3”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 1.771Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.771
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Strong copper grade in a significant sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is strong (1.771% vs VMS strong 1.5%).

Evidence · table

“1.771”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · leadGrade: 0.105Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.105
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Lead grade is above cutoff in a significant sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Lead grade is above the 0.1% cutoff.

Evidence · table

“0.105”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 2.302Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
2.302
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak zinc grade in a significant sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is weak (2.302% vs VMS weak 2%).

Evidence · table

“2.302”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · goldGrade: 1.373Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.373
Grade Unit
g/t
Intercept
6.1 m
From
45.72 m
To
51.82 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate gold grade in a high-grade polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Gold grade is moderate (1.373 g/t vs VMS moderate 1 g/t).

Evidence · table

“1.373”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · silverGrade: 147.9Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
147.9
Grade Unit
g/t
Intercept
6.1 m
From
45.72 m
To
51.82 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Strong silver grade in a high-grade polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Silver grade is strong (147.9 g/t vs VMS strong 200 g/t).

Evidence · table

“147.9”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · copperGrade: 3.18Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
3.18
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Exceptional copper grade in a high-grade polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is exceptional (3.180% vs VMS exceptional 2.5%).
  • Bonanza Intercept: Exceptionally high-grade copper zone.

Evidence · table

“3.180”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: Copper grade of 3.18% is well above the VMS exceptional threshold of 2.5%.

Evidence · table

“3.180”

Context: 6.10

SPC26001Hook Lake · leadGrade: 0.034Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.034
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a high-grade polymetallic sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.034”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001Hook Lake · zincGrade: 1.346Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.346
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Hole Depth
187.45 m
Intercept Depth
9.14 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26001:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
Easting
647405
Northing
6852089
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak zinc grade in a high-grade polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is weak (1.346% vs VMS weak 2%).

Evidence · table

“1.346”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.018Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.018
Grade Unit
g/t
Intercept
6.1 m
From
30.48 m
To
36.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:30.48-36.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak gold grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is below the 0.1 g/t cutoff.

Evidence · table

“0.018”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 1.1Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
6.1 m
From
30.48 m
To
36.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:30.48-36.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak silver grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is below the VMS weak threshold (1.1 g/t vs 30 g/t).

Evidence · table

“1.1”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 0.016Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.016
Grade Unit
%
Intercept
6.1 m
From
30.48 m
To
36.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:30.48-36.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the 0.1% cutoff.

Evidence · table

“0.016”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.001Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.001
Grade Unit
%
Intercept
6.1 m
From
30.48 m
To
36.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:30.48-36.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.001”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 0.41Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.41
Grade Unit
%
Intercept
6.1 m
From
30.48 m
To
36.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:30.48-36.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak zinc grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Zinc grade is below the VMS weak threshold (0.410% vs 2%).

Evidence · table

“0.410”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.148Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.148
Grade Unit
g/t
Intercept
6.1 m
From
35.05 m
To
41.15 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:35.05-41.15
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.148 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.148”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 9.4Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
9.4
Grade Unit
g/t
Intercept
6.1 m
From
35.05 m
To
41.15 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:35.05-41.15
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (9.4 g/t vs VMS weak 30 g/t).

Evidence · table

“9.4”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 0.225Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.225
Grade Unit
%
Intercept
6.1 m
From
35.05 m
To
41.15 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:35.05-41.15
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak copper grade in an intercept from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is weak (0.225% vs VMS weak 0.4%).

Evidence · table

“0.225”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.003Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.003
Grade Unit
%
Intercept
6.1 m
From
35.05 m
To
41.15 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:35.05-41.15
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.003”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 0.134Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.134
Grade Unit
%
Intercept
6.1 m
From
35.05 m
To
41.15 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:35.05-41.15
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak zinc grade in an intercept from maiden drilling at a new VMS target.

Negative factors

  • Zinc grade is below the VMS weak threshold (0.134% vs 2%).

Evidence · table

“0.134”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.085Grade Unit: g/tIntercept: 39.62 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.085
Grade Unit
g/t
Intercept
39.62 m
From
59.44 m
To
99.06 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-99.06
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak gold grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is below the 0.1 g/t cutoff.

Evidence · table

“0.085”

Context: 39.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 23.5Grade Unit: g/tIntercept: 39.62 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
23.5
Grade Unit
g/t
Intercept
39.62 m
From
59.44 m
To
99.06 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-99.06
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (23.5 g/t vs VMS weak 30 g/t).

Evidence · table

“23.5”

Context: 39.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 0.279Grade Unit: %Intercept: 39.62 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.279
Grade Unit
%
Intercept
39.62 m
From
59.44 m
To
99.06 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-99.06
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak copper grade in a broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is weak (0.279% vs VMS weak 0.4%).

Evidence · table

“0.279”

Context: 39.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.141Grade Unit: %Intercept: 39.62 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.141
Grade Unit
%
Intercept
39.62 m
From
59.44 m
To
99.06 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-99.06
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Lead grade is above cutoff in a broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Lead grade is above the 0.1% cutoff.

Evidence · table

“0.141”

Context: 39.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 1.321Grade Unit: %Intercept: 39.62 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.321
Grade Unit
%
Intercept
39.62 m
From
59.44 m
To
99.06 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-99.06
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak zinc grade in a broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is weak (1.321% vs VMS weak 2%).

Evidence · table

“1.321”

Context: 39.62

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.055Grade Unit: g/tIntercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.055
Grade Unit
g/t
Intercept
9.14 m
From
59.44 m
To
68.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak gold grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is below the 0.1 g/t cutoff.

Evidence · table

“0.055”

Context: 9.14

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 26.2Grade Unit: g/tIntercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
26.2
Grade Unit
g/t
Intercept
9.14 m
From
59.44 m
To
68.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Silver grade is weak (26.2 g/t vs VMS weak 30 g/t).

Evidence · table

“26.2”

Context: 9.14

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 0.067Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.067
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the 0.1% cutoff.

Evidence · table

“0.067”

Context: 9.14

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.448Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.448
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Lead grade is above cutoff in a sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Lead grade is above the 0.1% cutoff.

Evidence · table

“0.448”

Context: 9.14

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 2.802Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
2.802
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak zinc grade in a sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is weak (2.802% vs VMS weak 2%).

Evidence · table

“2.802”

Context: 9.14

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.274Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.274
Grade Unit
g/t
Intercept
6.1 m
From
73.15 m
To
79.25 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Gold grade is weak (0.274 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.274”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 88.3Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
88.3
Grade Unit
g/t
Intercept
6.1 m
From
73.15 m
To
79.25 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate silver grade in a polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Silver grade is moderate (88.3 g/t vs VMS moderate 100 g/t).

Evidence · table

“88.3”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 1.103Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.103
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Moderate copper grade in a polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is moderate (1.103% vs VMS moderate 0.8%).

Evidence · table

“1.103”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.147Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.147
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Lead grade is above cutoff in a polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Lead grade is above the 0.1% cutoff.

Evidence · table

“0.147”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 3.34Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
3.34
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Exceptional zinc grade in a polymetallic sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Zinc grade is exceptional (3.340% vs VMS exceptional 2.5%).

Evidence · table

“3.340”

Context: 6.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.217Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.217
Grade Unit
g/t
Intercept
1.52 m
From
91.44 m
To
92.96 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a narrow sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is weak (0.217 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.217”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 31.9Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
31.9
Grade Unit
g/t
Intercept
1.52 m
From
91.44 m
To
92.96 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a narrow sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Silver grade is weak (31.9 g/t vs VMS weak 30 g/t).

Evidence · table

“31.9”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 1.495Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.495
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Strong copper grade in a narrow sub-interval from maiden drilling at a new VMS target.

Positive factors

  • Copper grade is strong (1.495% vs VMS strong 1.5%).

Evidence · table

“1.495”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.018Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.018
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a narrow sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.018”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 0.12Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak zinc grade in a narrow sub-interval from maiden drilling at a new VMS target.

Negative factors

  • Zinc grade is below the VMS weak threshold (0.120% vs 2%).

Evidence · table

“0.120”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · goldGrade: 0.007Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.007
Grade Unit
g/t
Intercept
19.81 m
From
135.64 m
To
155.45 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:135.64-155.45
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak gold grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Gold grade is below the 0.1 g/t cutoff.

Evidence · table

“0.007”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · silverGrade: 1.4Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
19.81 m
From
135.64 m
To
155.45 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:135.64-155.45
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak silver grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is below the VMS weak threshold (1.4 g/t vs 30 g/t).

Evidence · table

“1.4”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · copperGrade: 0.008Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.008
Grade Unit
%
Intercept
19.81 m
From
135.64 m
To
155.45 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:135.64-155.45
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the 0.1% cutoff.

Evidence · table

“0.008”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · leadGrade: 0.008Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.008
Grade Unit
%
Intercept
19.81 m
From
135.64 m
To
155.45 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:135.64-155.45
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.008”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002Hook Lake · zincGrade: 0.228Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26002
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.228
Grade Unit
%
Intercept
19.81 m
From
135.64 m
To
155.45 m
Hole Depth
175.26 m
Intercept Depth
30.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26002:135.64-155.45
Mining Method
underground

Location

Location
Upper Zone
Easting
647349
Northing
6852038
CRS
NAD83 UTM Zone 15N
Elevation
88 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak zinc grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Zinc grade is below the VMS weak threshold (0.228% vs 2%).

Evidence · table

“0.228”

Context: 19.81

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26003Hook Lake · goldGrade: 0.126Grade Unit: g/tIntercept: 15.24 mView all details
Link to this fact

Identity

Hole ID
SPC26003
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.126
Grade Unit
g/t
Intercept
15.24 m
From
74.68 m
To
89.92 m
Hole Depth
167.64 m
Intercept Depth
74.68 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26003:74.68-89.92
Mining Method
underground

Location

Location
Upper Zone
Easting
647623
Northing
6852240
CRS
NAD83 UTM Zone 15N
Elevation
92 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak gold grade in a broad intercept from maiden drilling at a new VMS target.

Positive factors

  • Gold grade is weak (0.126 g/t vs VMS weak 0.3 g/t).

Evidence · table

“0.126”

Context: 15.24

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26003Hook Lake · silverGrade: 23.7Grade Unit: g/tIntercept: 15.24 mView all details
Link to this fact

Identity

Hole ID
SPC26003
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
23.7
Grade Unit
g/t
Intercept
15.24 m
From
74.68 m
To
89.92 m
Hole Depth
167.64 m
Intercept Depth
74.68 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26003:74.68-89.92
Mining Method
underground

Location

Location
Upper Zone
Easting
647623
Northing
6852240
CRS
NAD83 UTM Zone 15N
Elevation
92 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Weak silver grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Silver grade is weak (23.7 g/t vs VMS weak 30 g/t).

Evidence · table

“23.7”

Context: 15.24

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26003Hook Lake · copperGrade: 0.004Grade Unit: %Intercept: 15.24 mView all details
Link to this fact

Identity

Hole ID
SPC26003
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.004
Grade Unit
%
Intercept
15.24 m
From
74.68 m
To
89.92 m
Hole Depth
167.64 m
Intercept Depth
74.68 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26003:74.68-89.92
Mining Method
underground

Location

Location
Upper Zone
Easting
647623
Northing
6852240
CRS
NAD83 UTM Zone 15N
Elevation
92 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak copper grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Copper grade is below the 0.1% cutoff.

Evidence · table

“0.004”

Context: 15.24

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26003Hook Lake · leadGrade: 0.014Grade Unit: %Intercept: 15.24 mView all details
Link to this fact

Identity

Hole ID
SPC26003
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.014
Grade Unit
%
Intercept
15.24 m
From
74.68 m
To
89.92 m
Hole Depth
167.64 m
Intercept Depth
74.68 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26003:74.68-89.92
Mining Method
underground

Location

Location
Upper Zone
Easting
647623
Northing
6852240
CRS
NAD83 UTM Zone 15N
Elevation
92 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak lead grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Lead grade is below the 0.1% cutoff.

Evidence · table

“0.014”

Context: 15.24

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26003Hook Lake · zincGrade: 0.055Grade Unit: %Intercept: 15.24 mView all details
Link to this fact

Identity

Hole ID
SPC26003
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.055
Grade Unit
%
Intercept
15.24 m
From
74.68 m
To
89.92 m
Hole Depth
167.64 m
Intercept Depth
74.68 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
SPC26003:74.68-89.92
Mining Method
underground

Location

Location
Upper Zone
Easting
647623
Northing
6852240
CRS
NAD83 UTM Zone 15N
Elevation
92 m
Azimuth
340 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t Au or %
Dilution Disclosed
Yes
Max Dilution
4.56 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Very weak zinc grade in a broad intercept from maiden drilling at a new VMS target.

Negative factors

  • Zinc grade is below the 0.1% cutoff.

Evidence · table

“0.055”

Context: 15.24

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · goldGrade: 0.365Grade Unit: g/tIntercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.365
Grade Unit
g/t
Intercept
7.62 m
From
10.67 m
To
18.29 m
Intercept Depth
10.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.365 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.8 g/t·m is below.

Negative factors

  • 0.365 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.365”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · silverGrade: 12Grade Unit: g/tIntercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
12
Grade Unit
g/t
Intercept
7.62 m
From
10.67 m
To
18.29 m
Intercept Depth
10.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 91.4 g/t·m is below.

Negative factors

  • 12 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.0”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · copperGrade: 0.076Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.076
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Intercept Depth
10.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.076 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.6 %·m is below.

Negative factors

  • 0.076 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.076”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · leadGrade: 0.024Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.024
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Intercept Depth
10.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.024 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.024 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.024”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · zincGrade: 13.982Grade Unit: %Intercept: 7.62 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
13.982
Grade Unit
%
Intercept
7.62 m
From
10.67 m
To
18.29 m
Intercept Depth
10.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:10.67-18.29
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.982 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 106.5 %·m is strong.

Positive factors

  • 13.982 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.982”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · goldGrade: 0.244Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.244
Grade Unit
g/t
Intercept
3.05 m
From
12.19 m
To
15.24 m
Intercept Depth
12.19 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.244 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.244 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.244”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · silverGrade: 14.2Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
14.2
Grade Unit
g/t
Intercept
3.05 m
From
12.19 m
To
15.24 m
Intercept Depth
12.19 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 14.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 43.3 g/t·m is below.

Negative factors

  • 14.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.2”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · copperGrade: 0.087Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.087
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Intercept Depth
12.19 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.087 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.087 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.087”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · leadGrade: 0.041Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.041
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Intercept Depth
12.19 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.041 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.041 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.041”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · zincGrade: 29.5Grade Unit: %Intercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
29.5
Grade Unit
%
Intercept
3.05 m
From
12.19 m
To
15.24 m
Intercept Depth
12.19 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:12.19-15.24
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 29.5 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 90.0 %·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 29.5 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“29.500”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · goldGrade: 0.804Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.804
Grade Unit
g/t
Intercept
19.81 m
From
42.67 m
To
62.48 m
Intercept Depth
42.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.804 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 15.9 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.804”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · silverGrade: 84.3Grade Unit: g/tIntercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
84.3
Grade Unit
g/t
Intercept
19.81 m
From
42.67 m
To
62.48 m
Intercept Depth
42.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 84.3 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1670.0 g/t·m is moderate (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“84.3”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · copperGrade: 1.771Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.771
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Intercept Depth
42.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.771 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 35.1 %·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 1.771 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.771”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · leadGrade: 0.105Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.105
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Intercept Depth
42.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.105 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.1 %·m is below.

Negative factors

  • 0.105 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.105”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · zincGrade: 2.302Grade Unit: %Intercept: 19.81 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
2.302
Grade Unit
%
Intercept
19.81 m
From
42.67 m
To
62.48 m
Intercept Depth
42.67 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:42.67-62.48
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.302 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 45.6 %·m is moderate (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.302”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · goldGrade: 1.373Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.373
Grade Unit
g/t
Intercept
6.1 m
From
45.72 m
To
51.82 m
Intercept Depth
45.72 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.373 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 1.373 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.373”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · silverGrade: 147.9Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
147.9
Grade Unit
g/t
Intercept
6.1 m
From
45.72 m
To
51.82 m
Intercept Depth
45.72 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 147.9 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 902.2 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“147.9”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · copperGrade: 3.18Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
3.18
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Intercept Depth
45.72 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.18 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 19.4 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.18 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.180”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · leadGrade: 0.034Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.034
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Intercept Depth
45.72 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.034 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.034 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.034”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26001 includingHook Lake · zincGrade: 1.346Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26001 including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.346
Grade Unit
%
Intercept
6.1 m
From
45.72 m
To
51.82 m
Intercept Depth
45.72 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26001 including:45.72-51.82
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.346 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 8.2 %·m is below.

Negative factors

  • 1.346 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.346”

Context: SPC26001 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 includingHook Lake · goldGrade: 0.055Grade Unit: g/tIntercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002 including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.055
Grade Unit
g/t
Intercept
9.14 m
From
59.44 m
To
68.58 m
Intercept Depth
59.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 including:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.055 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.055 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.055”

Context: SPC26002 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 includingHook Lake · silverGrade: 26.2Grade Unit: g/tIntercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002 including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
26.2
Grade Unit
g/t
Intercept
9.14 m
From
59.44 m
To
68.58 m
Intercept Depth
59.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 including:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 26.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 239.5 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“26.2”

Context: SPC26002 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 includingHook Lake · copperGrade: 0.067Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002 including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.067
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Intercept Depth
59.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 including:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.067 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.6 %·m is below.

Negative factors

  • 0.067 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.067”

Context: SPC26002 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 includingHook Lake · leadGrade: 0.448Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002 including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.448
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Intercept Depth
59.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 including:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.448 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 4.1 %·m is below.

Negative factors

  • 0.448 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.448”

Context: SPC26002 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 includingHook Lake · zincGrade: 2.802Grade Unit: %Intercept: 9.14 mView all details
Link to this fact

Identity

Hole ID
SPC26002 including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
2.802
Grade Unit
%
Intercept
9.14 m
From
59.44 m
To
68.58 m
Intercept Depth
59.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 including:59.44-68.58
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.802 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 25.6 %·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.802”

Context: SPC26002 including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · goldGrade: 0.274Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.274
Grade Unit
g/t
Intercept
6.1 m
From
73.15 m
To
79.25 m
Intercept Depth
73.15 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.274 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 0.274 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.274”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · silverGrade: 88.3Grade Unit: g/tIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
88.3
Grade Unit
g/t
Intercept
6.1 m
From
73.15 m
To
79.25 m
Intercept Depth
73.15 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 88.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 538.6 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“88.3”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · copperGrade: 1.103Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.103
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Intercept Depth
73.15 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.103 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 6.7 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.103”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · leadGrade: 0.147Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.147
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Intercept Depth
73.15 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.147 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.9 %·m is below.

Negative factors

  • 0.147 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.147”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · zincGrade: 3.34Grade Unit: %Intercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
3.34
Grade Unit
%
Intercept
6.1 m
From
73.15 m
To
79.25 m
Intercept Depth
73.15 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:73.15-79.25
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.34 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 20.4 %·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.340”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · goldGrade: 0.217Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
gold
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.217
Grade Unit
g/t
Intercept
1.52 m
From
91.44 m
To
92.96 m
Intercept Depth
91.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.217 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.217 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.217”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · silverGrade: 31.9Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
silver
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
31.9
Grade Unit
g/t
Intercept
1.52 m
From
91.44 m
To
92.96 m
Intercept Depth
91.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 31.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 48.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“31.9”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · copperGrade: 1.495Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
copper
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
1.495
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Intercept Depth
91.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.495 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.3 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.495”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · leadGrade: 0.018Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
lead
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.018
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Intercept Depth
91.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.018 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.018 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.018”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

SPC26002 IncludingHook Lake · zincGrade: 0.12Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
SPC26002 Including
Project
Hook Lake
Commodity
zinc
Region
canada_nu
Reported Region
canada_nu
Ticker
MHC

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.52 m
From
91.44 m
To
92.96 m
Intercept Depth
91.44 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
SPC26002 Including:91.44-92.96
Mining Method
underground

Location

Location
Upper Zone
CRS
NAD83 UTM Zone 15N
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.12 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.120”

Context: SPC26002 Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Key Highlights ▪ SPC26001 hits high-grade copper, gold, silver and zinc in maiden drilling at Spectre: o 6.10m @ 3.18% C"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.