# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project in Southern Namibia

Canonical Atlas analysis: https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3

Original source: https://orestocks.com/company/KRY.V/press-releases/6859631530268782

Publisher: orestocks

Original announcement: 2026-09-22T11:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: 2026-09-22T12:24:53.552Z

Atlas analysis updated: 2026-09-22T12:24:53.552Z

- Company: Koryx Copper

- Ticker: KRY.V

- Exchange: Unavailable

- Region: southern Namibia

- Primary commodity: Copper

- Secondary commodities: Molybdenum, Gold

- Document categories: Drill results, Resource update

- Extracted: 2026-09-22 12:24:54 UTC

Narrative sentiment: 0.70 · Bullish

## Minestarters Atlas summary

Koryx Copper has completed its PFS drill program at the Haib Copper Project in southern Namibia, announcing further positive infill and expansion drill results from 18 holes totaling 7,074m. The results show very wide intercepts, including several higher-grade zones, particularly near surface in Target Area 3. The company is now focused on completing an updated Mineral Resource Estimate and Pre-Feasibility Study, both on track for publication before the end of 2026.

Reasoning: The announcement reports positive infill and expansion drill results from the Haib Copper Project, featuring very wide intercepts and some high-grade zones, which is highly material for a porphyry deposit. The completion of the PFS drill program ahead of an updated MRE and PFS adds confidence to the project's development timeline. While true widths are not disclosed, the overall results are consistent with expectations and the geological model, supporting the project's potential.

- Positive factor: Very wide intercepts, consistent with a porphyry deposit, confirming continuity and scale.

- Positive factor: Several higher-grade zones identified, particularly near surface in Target Area 3, which is scheduled for early mine development.

- Positive factor: Drilling program completed, de-risking the upcoming MRE and PFS.

- Positive factor: Robust QA/QC procedures disclosed, including certified labs and QP sign-off.

- Positive factor: Metal equivalent assumptions are fully disclosed, providing transparency.

- Negative factor: True widths are not stated, meaning reported lengths are apparent widths and may overstate true thickness.

- Negative factor: One hole \(HM200\) did not intersect predicted high-grade mineralization, indicating some geological uncertainty.

- Negative factor: Cut-off grade for compositing is based on CuEq, which can mask individual metal grades.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 105

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 105. Some facts used in scoring do not have a stored record.

## Drill Results (105)

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-0)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 324 m
- From: 0 m
- To: 324 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-324
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.31
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide intercept confirms mineralization over a significant length, consistent with the porphyry deposit model, and contributes to resource definition.

- Positive factor: Very wide intercept \(324m\) indicating significant mineralization continuity.

- Positive factor: Infill hole confirming expectations in Target Area 3.

- Negative factor: Grade is below the porphyry strong threshold \(0.8% Cu\).

Evidence · table

> 0.28

Context: 324

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-1)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 42
- Grade Unit: ppm
- Intercept: 324 m
- From: 0 m
- To: 324 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-324
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.31
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 42

Context: 324

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-2)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.018
- Grade Unit: g/t
- Intercept: 324 m
- From: 0 m
- To: 324 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-324
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.31
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.018

Context: 324

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-3)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.31
- Grade Unit: %
- Intercept: 324 m
- From: 0 m
- To: 324 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-324
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.31
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: The CuEq grade over a significant width indicates consistent mineralization, supporting the overall resource potential.

- Positive factor: Wide intercept \(324m\) with a CuEq grade above the porphyry weak threshold \(0.15% CuEq\).

Evidence · table

> 0.31

Context: 324

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-4)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.42
- Grade Unit: %
- Intercept: 58 m
- From: 0 m
- To: 58 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-58
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This near-surface intercept with a higher-than-predicted grade is positive for potential open-pit mining and resource upgrade.

- Positive factor: Good grade \(0.42% Cu\) over a significant width \(58m\) near surface.

- Positive factor: Significantly higher grade than predicted by the model for this near-surface intersection.

Evidence · table

> 0.42

Context: 58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-5)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 30
- Grade Unit: ppm
- Intercept: 58 m
- From: 0 m
- To: 58 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-58
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a significant interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 30

Context: 58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-6)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.026
- Grade Unit: g/t
- Intercept: 58 m
- From: 0 m
- To: 58 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-58
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a significant interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.026

Context: 58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-7)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 58 m
- From: 0 m
- To: 58 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:0-58
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This near-surface intercept with a higher-than-predicted CuEq grade is positive for potential open-pit mining and resource upgrade.

- Positive factor: Good CuEq grade \(0.45% CuEq\) over a significant width \(58m\) near surface, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.45

Context: 58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-8)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.53
- Grade Unit: %
- Intercept: 4 m
- From: 8 m
- To: 12 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:8-12
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.59
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, higher-grade intercept contributes positively to the overall grade profile of the near-surface mineralization.

- Positive factor: Good copper grade \(0.53% Cu\) for a porphyry deposit.

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.53

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-9)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 61
- Grade Unit: ppm
- Intercept: 4 m
- From: 8 m
- To: 12 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:8-12
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.59
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 61

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-10)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.048
- Grade Unit: g/t
- Intercept: 4 m
- From: 8 m
- To: 12 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:8-12
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.59
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.048

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-11)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 4 m
- From: 8 m
- To: 12 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:8-12
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.59
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, higher-grade CuEq intercept contributes positively to the overall grade profile of the near-surface mineralization.

- Positive factor: Good CuEq grade \(0.59% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.59

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-12)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 20 m
- From: 24 m
- To: 44 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:24-44
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.63
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This strong copper intercept near surface enhances the potential for early open-pit mining.

- Positive factor: Strong copper grade \(0.59% Cu\) over a good width \(20m\) near surface.

Evidence · table

> 0.59

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-13)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 43
- Grade Unit: ppm
- Intercept: 20 m
- From: 24 m
- To: 44 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:24-44
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.63
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a good interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 43

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-14)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.039
- Grade Unit: g/t
- Intercept: 20 m
- From: 24 m
- To: 44 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:24-44
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.63
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a good interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.039

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-15)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.63
- Grade Unit: %
- Intercept: 20 m
- From: 24 m
- To: 44 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:24-44
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.63
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This strong CuEq intercept near surface enhances the potential for early open-pit mining.

- Positive factor: Strong CuEq grade \(0.63% CuEq\) over a good width \(20m\) near surface, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.63

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-16)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 8 m
- From: 64 m
- To: 72 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:64-72
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Copper grade is above the porphyry weak threshold \(0.15% Cu\).

Evidence · table

> 0.30

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-17)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 8 m
- From: 64 m
- To: 72 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:64-72
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 8

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-18)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.021
- Grade Unit: g/t
- Intercept: 8 m
- From: 64 m
- To: 72 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:64-72
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.021

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-19)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 8 m
- From: 64 m
- To: 72 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:64-72
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: CuEq grade is above the porphyry weak threshold \(0.15% CuEq\).

Evidence · table

> 0.32

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-20)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 42 m
- From: 112 m
- To: 154 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:112-154
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.32% Cu\) over a significant width \(42m\).

Evidence · table

> 0.32

Context: 42

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-21)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 178
- Grade Unit: ppm
- Intercept: 42 m
- From: 112 m
- To: 154 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:112-154
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Elevated molybdenum grades over a significant width contribute positively to the overall economic potential of the intercept.

- Positive factor: Molybdenum grade is above the average for the project.

Evidence · table

> 178

Context: 42

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-22)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.025
- Grade Unit: g/t
- Intercept: 42 m
- From: 112 m
- To: 154 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:112-154
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a significant interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.025

Context: 42

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-23)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 42 m
- From: 112 m
- To: 154 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:112-154
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.40% CuEq\) over a significant width \(42m\), above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.40

Context: 42

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-24)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 6 m
- From: 124 m
- To: 130 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:124-130
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This higher-grade sub-interval contributes positively to the overall grade profile.

- Positive factor: Good copper grade \(0.45% Cu\) for a porphyry deposit.

Evidence · table

> 0.45

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-25)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 615
- Grade Unit: ppm
- Intercept: 6 m
- From: 124 m
- To: 130 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:124-130
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This high molybdenum grade contributes significantly to the overall economic potential of the intercept.

- Positive factor: High molybdenum grade \(615 ppm\) for the project, significantly above the average.

Evidence · table

> 615

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-26)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 6 m
- From: 124 m
- To: 130 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:124-130
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.030

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-27)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 6 m
- From: 124 m
- To: 130 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:124-130
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This higher-grade CuEq sub-interval contributes positively to the overall grade profile.

- Positive factor: Good CuEq grade \(0.70% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.70

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-28)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.77
- Grade Unit: %
- Intercept: 2 m
- From: 136 m
- To: 138 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:136-138
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.98
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very narrow, high-grade intercept contributes positively to the overall grade profile.

- Positive factor: Strong copper grade \(0.77% Cu\) for a porphyry deposit.

- Negative factor: Very narrow intercept length \(2m\).

Evidence · table

> 0.77

Context: 2

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-29)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 252
- Grade Unit: ppm
- Intercept: 2 m
- From: 136 m
- To: 138 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:136-138
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.98
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This elevated molybdenum grade contributes positively to the overall economic potential of the intercept.

- Positive factor: Elevated molybdenum grade \(252 ppm\) for the project.

- Negative factor: Very narrow intercept length \(2m\).

Evidence · table

> 252

Context: 2

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-30)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.165
- Grade Unit: g/t
- Intercept: 2 m
- From: 136 m
- To: 138 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:136-138
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.98
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This gold grade, while narrow, is above the weak threshold for porphyry deposits and contributes positively to the overall economic potential.

- Positive factor: Gold grade is above the porphyry weak threshold \(0.15 g/t Au\).

- Negative factor: Very narrow intercept length \(2m\).

Evidence · table

> 0.165

Context: 2

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-31)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 2 m
- From: 136 m
- To: 138 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:136-138
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.98
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very narrow, high-grade CuEq intercept contributes positively to the overall grade profile.

- Positive factor: Strong CuEq grade \(0.98% CuEq\) for a porphyry deposit, above the porphyry strong threshold \(0.4% CuEq\).

- Negative factor: Very narrow intercept length \(2m\).

Evidence · table

> 0.98

Context: 2

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-32)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 4 m
- From: 160 m
- To: 164 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:160-164
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.73
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, high-grade intercept contributes positively to the overall grade profile.

- Positive factor: Strong copper grade \(0.70% Cu\) for a porphyry deposit.

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.70

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-33)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 4 m
- From: 160 m
- To: 164 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:160-164
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.73
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 29

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-34)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.027
- Grade Unit: g/t
- Intercept: 4 m
- From: 160 m
- To: 164 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:160-164
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.73
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.027

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-35)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 4 m
- From: 160 m
- To: 164 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:160-164
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.73
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, high-grade CuEq intercept contributes positively to the overall grade profile.

- Positive factor: Strong CuEq grade \(0.73% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.73

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-36)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 18 m
- From: 176 m
- To: 194 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:176-194
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.45% Cu\) over a good width \(18m\).

Evidence · table

> 0.45

Context: 18

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-37)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 19
- Grade Unit: ppm
- Intercept: 18 m
- From: 176 m
- To: 194 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:176-194
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 19

Context: 18

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-38)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.022
- Grade Unit: g/t
- Intercept: 18 m
- From: 176 m
- To: 194 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:176-194
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.022

Context: 18

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-39)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.48
- Grade Unit: %
- Intercept: 18 m
- From: 176 m
- To: 194 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:176-194
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.48
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.48% CuEq\) over a good width \(18m\), above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.48

Context: 18

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-40)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.76
- Grade Unit: %
- Intercept: 4 m
- From: 186 m
- To: 190 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:186-190
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, high-grade intercept contributes positively to the overall grade profile.

- Positive factor: Strong copper grade \(0.76% Cu\) for a porphyry deposit.

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.76

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-41)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 45
- Grade Unit: ppm
- Intercept: 4 m
- From: 186 m
- To: 190 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:186-190
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 45

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-42)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.031
- Grade Unit: g/t
- Intercept: 4 m
- From: 186 m
- To: 190 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:186-190
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.031

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-43)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.8
- Grade Unit: %
- Intercept: 4 m
- From: 186 m
- To: 190 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:186-190
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, high-grade CuEq intercept contributes positively to the overall grade profile.

- Positive factor: Strong CuEq grade \(0.80% CuEq\) for a porphyry deposit, above the porphyry strong threshold \(0.4% CuEq\).

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.80

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-44)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 10 m
- From: 206 m
- To: 216 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:206-216
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.36
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Copper grade is above the porphyry weak threshold \(0.15% Cu\).

Evidence · table

> 0.34

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-45)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 10 m
- From: 206 m
- To: 216 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:206-216
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.36
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 8

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-46)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.018
- Grade Unit: g/t
- Intercept: 10 m
- From: 206 m
- To: 216 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:206-216
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.36
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.018

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-47)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 10 m
- From: 206 m
- To: 216 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:206-216
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.36
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: CuEq grade is above the porphyry weak threshold \(0.15% CuEq\).

Evidence · table

> 0.36

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-48)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 8 m
- From: 224 m
- To: 232 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:224-232
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Copper grade is above the porphyry weak threshold \(0.15% Cu\).

Evidence · table

> 0.25

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-49)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 115
- Grade Unit: ppm
- Intercept: 8 m
- From: 224 m
- To: 232 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:224-232
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Elevated molybdenum grades contribute positively to the overall economic potential of the intercept.

- Positive factor: Molybdenum grade is above the average for the project.

Evidence · table

> 115

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-50)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.014
- Grade Unit: g/t
- Intercept: 8 m
- From: 224 m
- To: 232 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:224-232
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.014

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-51)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 8 m
- From: 224 m
- To: 232 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:224-232
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: CuEq grade is at the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.30

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-52)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 6 m
- From: 242 m
- To: 248 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:242-248
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.45% Cu\) for a porphyry deposit.

Evidence · table

> 0.45

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-53)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 6 m
- From: 242 m
- To: 248 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:242-248
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 7

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-54)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.024
- Grade Unit: g/t
- Intercept: 6 m
- From: 242 m
- To: 248 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:242-248
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.024

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-55)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 6 m
- From: 242 m
- To: 248 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:242-248
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.47% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.47

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-56)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 4 m
- From: 274 m
- To: 278 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:274-278
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.43% Cu\) for a porphyry deposit.

Evidence · table

> 0.43

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-57)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 4 m
- From: 274 m
- To: 278 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:274-278
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 15

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-58)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.049
- Grade Unit: g/t
- Intercept: 4 m
- From: 274 m
- To: 278 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:274-278
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.049

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-59)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 4 m
- From: 274 m
- To: 278 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:274-278
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.47
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.47% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.47

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-60)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 8 m
- From: 308 m
- To: 316 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:308-316
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.40% Cu\) for a porphyry deposit.

Evidence · table

> 0.40

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-61)

Haib · molybdenum

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 8 m
- From: 308 m
- To: 316 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:308-316
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 11

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-62)

Haib · gold

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.028
- Grade Unit: g/t
- Intercept: 8 m
- From: 308 m
- To: 316 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:308-316
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.028

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM182

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-63)

Haib · copper

#### Identity

- Hole ID: HM182
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 8 m
- From: 308 m
- To: 316 m
- Hole Depth: 324 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM182:308-316
- Mining Method: open\_pit

#### Location

- Easting: 780571
- Northing: 6823302
- Elevation: 538 m
- Azimuth: 33 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.43% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.43

Context: 8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-64)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 429 m
- From: 0 m
- To: 429 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:0-429
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide intercept confirms mineralization over a significant length, consistent with the porphyry deposit model, and contributes to resource definition.

- Positive factor: Very wide intercept \(429m\) indicating significant mineralization continuity.

- Positive factor: Infill hole confirming expectations.

- Negative factor: Grade is below the porphyry strong threshold \(0.8% Cu\).

Evidence · table

> 0.26

Context: 429

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-65)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 57
- Grade Unit: ppm
- Intercept: 429 m
- From: 0 m
- To: 429 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:0-429
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 57

Context: 429

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-66)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 429 m
- From: 0 m
- To: 429 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:0-429
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.020

Context: 429

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-67)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 429 m
- From: 0 m
- To: 429 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:0-429
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide intercept confirms mineralization over a significant length, consistent with the porphyry deposit model, and contributes to resource definition.

- Positive factor: Very wide intercept \(429m\) with CuEq grade at the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.30

Context: 429

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-68)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 38 m
- From: 54 m
- To: 92 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:54-92
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.35% Cu\) over a significant width \(38m\).

Evidence · table

> 0.35

Context: 38

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-69)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 142
- Grade Unit: ppm
- Intercept: 38 m
- From: 54 m
- To: 92 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:54-92
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Elevated molybdenum grades over a significant width contribute positively to the overall economic potential of the intercept.

- Positive factor: Molybdenum grade is above the average for the project.

Evidence · table

> 142

Context: 38

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-70)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 38 m
- From: 54 m
- To: 92 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:54-92
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.020

Context: 38

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-71)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.41
- Grade Unit: %
- Intercept: 38 m
- From: 54 m
- To: 92 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:54-92
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.41% CuEq\) over a significant width \(38m\), above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.41

Context: 38

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-72)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 6 m
- From: 76 m
- To: 82 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:76-82
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.62
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, higher-grade intercept contributes positively to the overall grade profile.

- Positive factor: Good copper grade \(0.47% Cu\) for a porphyry deposit.

- Negative factor: Narrow intercept length \(6m\).

Evidence · table

> 0.47

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-73)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 390
- Grade Unit: ppm
- Intercept: 6 m
- From: 76 m
- To: 82 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:76-82
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.62
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This high molybdenum grade contributes significantly to the overall economic potential of the intercept.

- Positive factor: High molybdenum grade \(390 ppm\) for the project, significantly above the average.

- Negative factor: Narrow intercept length \(6m\).

Evidence · table

> 390

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-74)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.018
- Grade Unit: g/t
- Intercept: 6 m
- From: 76 m
- To: 82 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:76-82
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.62
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.018

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-75)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.62
- Grade Unit: %
- Intercept: 6 m
- From: 76 m
- To: 82 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:76-82
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.62
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, higher-grade CuEq intercept contributes positively to the overall grade profile.

- Positive factor: Good CuEq grade \(0.62% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

- Negative factor: Narrow intercept length \(6m\).

Evidence · table

> 0.62

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-76)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 32 m
- From: 102 m
- To: 134 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:102-134
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.38
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.35% Cu\) over a significant width \(32m\).

Evidence · table

> 0.35

Context: 32

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-77)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 58
- Grade Unit: ppm
- Intercept: 32 m
- From: 102 m
- To: 134 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:102-134
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.38
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a significant interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 58

Context: 32

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-78)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.021
- Grade Unit: g/t
- Intercept: 32 m
- From: 102 m
- To: 134 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:102-134
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.38
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.021

Context: 32

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-79)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.38
- Grade Unit: %
- Intercept: 32 m
- From: 102 m
- To: 134 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:102-134
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.38
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.38% CuEq\) over a significant width \(32m\), above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.38

Context: 32

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-80)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.51
- Grade Unit: %
- Intercept: 82 m
- From: 314 m
- To: 396 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:314-396
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.56
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide, strong copper intercept significantly enhances the resource potential.

- Positive factor: Strong copper grade \(0.51% Cu\) over a very wide intercept \(82m\).

Evidence · table

> 0.51

Context: 82

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-81)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 65
- Grade Unit: ppm
- Intercept: 82 m
- From: 314 m
- To: 396 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:314-396
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.56
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a very wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 65

Context: 82

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-82)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.037
- Grade Unit: g/t
- Intercept: 82 m
- From: 314 m
- To: 396 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:314-396
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.56
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a very wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.037

Context: 82

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-83)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.56
- Grade Unit: %
- Intercept: 82 m
- From: 314 m
- To: 396 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:314-396
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.56
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide, strong CuEq intercept significantly enhances the resource potential.

- Positive factor: Strong CuEq grade \(0.56% CuEq\) over a very wide intercept \(82m\), above the porphyry strong threshold \(0.4% CuEq\).

Evidence · table

> 0.56

Context: 82

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-84)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.94
- Grade Unit: %
- Intercept: 4 m
- From: 334 m
- To: 338 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:334-338
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, exceptional grade intercept significantly enhances the overall grade profile.

- Positive factor: Exceptional copper grade \(0.94% Cu\) for a porphyry deposit, above the porphyry strong threshold \(0.8% Cu\).

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 0.94

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-85)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 31
- Grade Unit: ppm
- Intercept: 4 m
- From: 334 m
- To: 338 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:334-338
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Molybdenum grade is very low.

Evidence · table

> 31

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-86)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.093
- Grade Unit: g/t
- Intercept: 4 m
- From: 334 m
- To: 338 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:334-338
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.093

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-87)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 1.01
- Grade Unit: %
- Intercept: 4 m
- From: 334 m
- To: 338 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:334-338
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.01
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This narrow, exceptional CuEq grade intercept significantly enhances the overall grade profile.

- Positive factor: Exceptional CuEq grade \(1.01% CuEq\) for a porphyry deposit, above the porphyry strong threshold \(0.4% CuEq\).

- Negative factor: Narrow intercept length \(4m\).

Evidence · table

> 1.01

Context: 4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-88)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.95
- Grade Unit: %
- Intercept: 20 m
- From: 354 m
- To: 374 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:354-374
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.05
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This exceptional copper intercept over a good width significantly enhances the resource potential.

- Positive factor: Exceptional copper grade \(0.95% Cu\) over a good width \(20m\) for a porphyry deposit, above the porphyry strong threshold \(0.8% Cu\).

Evidence · table

> 0.95

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-89)

Haib · molybdenum

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 105
- Grade Unit: ppm
- Intercept: 20 m
- From: 354 m
- To: 374 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:354-374
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.05
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Elevated molybdenum grades over a good width contribute positively to the overall economic potential of the intercept.

- Positive factor: Molybdenum grade is above the average for the project.

Evidence · table

> 105

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-90)

Haib · gold

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.083
- Grade Unit: g/t
- Intercept: 20 m
- From: 354 m
- To: 374 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:354-374
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.05
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a good interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.083

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM191

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-91)

Haib · copper

#### Identity

- Hole ID: HM191
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 1.05
- Grade Unit: %
- Intercept: 20 m
- From: 354 m
- To: 374 m
- Hole Depth: 429 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM191:354-374
- Mining Method: open\_pit

#### Location

- Easting: 780755
- Northing: 6823351
- Elevation: 526 m
- Azimuth: 10 °
- Dip: -59 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 1.05
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This exceptional CuEq intercept over a good width significantly enhances the resource potential.

- Positive factor: Exceptional CuEq grade \(1.05% CuEq\) over a good width \(20m\) for a porphyry deposit, above the porphyry strong threshold \(0.4% CuEq\).

Evidence · table

> 1.05

Context: 20

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-92)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 648 m
- From: 0 m
- To: 648 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:0-648
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide intercept confirms mineralization over a significant length, consistent with the porphyry deposit model, and contributes to resource definition.

- Positive factor: Very wide intercept \(648m\) indicating significant mineralization continuity.

- Positive factor: Infill hole correlating well with existing grade model.

- Negative factor: Grade is below the porphyry strong threshold \(0.8% Cu\).

Evidence · table

> 0.18

Context: 648

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-93)

Haib · molybdenum

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 65
- Grade Unit: ppm
- Intercept: 648 m
- From: 0 m
- To: 648 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:0-648
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a very wide interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 65

Context: 648

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-94)

Haib · gold

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.021
- Grade Unit: g/t
- Intercept: 648 m
- From: 0 m
- To: 648 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:0-648
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.021

Context: 648

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-95)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 648 m
- From: 0 m
- To: 648 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:0-648
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This very wide intercept confirms mineralization over a significant length, consistent with the porphyry deposit model, and contributes to resource definition.

- Positive factor: Very wide intercept \(648m\) with CuEq grade at the porphyry weak threshold \(0.15% CuEq\).

Evidence · table

> 0.22

Context: 648

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-96)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 10 m
- From: 318 m
- To: 328 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:318-328
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.36% Cu\) for a porphyry deposit.

Evidence · table

> 0.36

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-97)

Haib · molybdenum

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 83
- Grade Unit: ppm
- Intercept: 10 m
- From: 318 m
- To: 328 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:318-328
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Molybdenum is present as a credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Molybdenum contributes to the overall CuEq grade.

- Negative factor: Molybdenum grade is relatively low.

Evidence · table

> 83

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-98)

Haib · gold

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.045
- Grade Unit: g/t
- Intercept: 10 m
- From: 318 m
- To: 328 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:318-328
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present as a minor credit over a narrow interval, contributing to the overall economic potential of the intercept.

- Positive factor: Gold contributes to the overall CuEq grade.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.045

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-99)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.42
- Grade Unit: %
- Intercept: 10 m
- From: 318 m
- To: 328 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:318-328
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.42% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.42

Context: 10

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-100)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 6 m
- From: 352 m
- To: 358 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:352-358
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.36% Cu\) for a porphyry deposit.

Evidence · table

> 0.36

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-101)

Haib · molybdenum

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: molybdenum
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 134
- Grade Unit: ppm
- Intercept: 6 m
- From: 352 m
- To: 358 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:352-358
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Elevated molybdenum grades contribute positively to the overall economic potential of the intercept.

- Positive factor: Molybdenum grade is above the average for the project.

Evidence · table

> 134

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-102)

Haib · gold

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: gold
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.026
- Grade Unit: g/t
- Intercept: 6 m
- From: 352 m
- To: 358 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:352-358
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: Gold is present but at very low grades, contributing minimally to the overall economic potential.

- Negative factor: Gold grade is very low, below the porphyry weak threshold \(0.15 g/t Au\).

Evidence · table

> 0.026

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-103)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 6 m
- From: 352 m
- To: 358 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:352-358
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.43
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good CuEq grade \(0.43% CuEq\) for a porphyry deposit, above the porphyry moderate threshold \(0.25% CuEq\).

Evidence · table

> 0.43

Context: 6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

### HM189

[Link to this fact](https://atlas-staging.minestarters.com/news/koryx-copper-completes-pfs-drill-program-announces-further-positive-infill-drill--b1e23a8f-4cd0-4381-80e6-11b08e4b00b3#fact-drill-facts-104)

Haib · copper

#### Identity

- Hole ID: HM189
- Project: Haib
- Commodity: copper
- Region: namibia
- Reported Region: namibia
- Ticker: KRY.V

#### Geometry

- Grade: 0.46
- Grade Unit: %
- Intercept: 14 m
- From: 434 m
- To: 448 m
- Hole Depth: 648 m
- Intercept Depth: 0 m

#### Classification

- Deposit Type: porphyry
- Program: mixed
- Sample Type: drill
- Group ID: HM189:434-448
- Mining Method: open\_pit

#### Location

- Easting: 781453
- Northing: 6822386
- Elevation: 551 m
- Azimuth: 17 °
- Dip: -71 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS Laboratories Ltd. in Johannesburg, South Africa and ActLabs in Canada
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Metal Eq. Grade: 0.59
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Compositing

- Cutoff Grade: 0.3
- Cutoff Unit: % CuEq

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-22T00:00:00.000Z

Reasoning: This intercept contributes to the overall mineralization profile, consistent with the deposit model.

- Positive factor: Good copper grade \(0.46% Cu\) over a good width \(14m\).

Evidence · table

> 0.46

Context: 14

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "\# Koryx Copper Completes PFS Drill Program, Announces Further Positive Infill Drill Results at the Haib Copper Project i"

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
