Inventus Expands Shallow High-Grade Main Layer and Identifies Broad Bulk-Tonnage Gold Potential at Pardo
Original announcement by orestocks on
- Company
- Inventus Mining Corp.
- Ticker
- IVS.V
- Exchange
- Unavailable
- Region
- Ontario
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results, Metallurgy, Resource update
- Extracted
- 2026-09-23 11:47:03 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Inventus Mining reported results from 100 drill holes at its Pardo "River of Gold" Project in Ontario, confirming shallow, high-grade gold mineralization in the Main Layer, including 30.04 g/t gold over 0.33 m within 2.09 m at 4.96 g/t gold from 2.72 m depth. The drilling also identified broad, lower-grade mineralization across multiple stacked layers, indicating significant bulk-tonnage potential. The company plans a maiden mineral resource estimate for Q4 2026, with 89 drill results pending and Phase 3 drilling to commence in mid-October.
Reasoning: The Phase 2 drill results confirm and expand shallow, high-grade gold mineralization in multiple zones, including bonanza grades, and delineate significant bulk-tonnage potential across several stacked layers, all supported by transparent QA/QC and true width reporting.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
- QA/QC Disclosed
- Shallow Mineralization
- Bulk-Tonnage Potential
Negative factors
- Cut-off Undisclosed
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 96
Classification and evidence
Heap Leach Routeneutral
Processing via heap leach — lower CAPEX and OPEX, lower recovery expected.
Why it applies: the document describes a heap_leach route ("heap leaching")
Extracted facts
Stored fact records: 96. Some facts used in scoring do not have a stored record.
Drill Results (96)
PD-26-301Pardo "River of · goldGrade: 0.43Grade Unit: g/tIntercept: 5.21 mView all detailsHide details
Identity
- Hole ID
- PD-26-301
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 5.21 m
- True Width
- 5.21 m
- From
- 25.86 m
- To
- 31.07 m
- Hole Depth
- 34 m
- Intercept Depth
- 25.86 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-301:25.86-31.07
- Mining Method
- open_pit
Location
- Location
- MiBC-MaC
- Easting
- 555814
- Northing
- 5183157
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A low-grade intercept, but contributes to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.43”
Context: 5.21
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.21
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-302Pardo "River of · goldGrade: 0.94Grade Unit: g/tIntercept: 2.01 mView all detailsHide details
Identity
- Hole ID
- PD-26-302
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.94
- Grade Unit
- g/t
- Intercept
- 2.01 m
- True Width
- 2.01 m
- From
- 30.5 m
- To
- 32.51 m
- Hole Depth
- 38.5 m
- Intercept Depth
- 30.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-302:30.5-32.51
- Mining Method
- open_pit
Location
- Location
- MiBC-MaC
- Easting
- 555836
- Northing
- 5183138
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade intercept contributing to the understanding of the deposit, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.94”
Context: 2.01
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.01
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-302Pardo "River of · goldGrade: 4.35Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- PD-26-302
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 4.35
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.3 m
- From
- 30.95 m
- To
- 31.25 m
- Hole Depth
- 38.5 m
- Intercept Depth
- 30.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-302:30.95-31.25
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555836
- Northing
- 5183138
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“4.35”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-304Pardo "River of · goldGrade: 0.51Grade Unit: g/tIntercept: 3.6 mView all detailsHide details
Identity
- Hole ID
- PD-26-304
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.51
- Grade Unit
- g/t
- Intercept
- 3.6 m
- True Width
- 3.6 m
- From
- 28.74 m
- To
- 32.34 m
- Hole Depth
- 38.5 m
- Intercept Depth
- 28.74 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-304:28.74-32.34
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555837
- Northing
- 5183190
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A low-grade intercept, but contributes to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.51”
Context: 3.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-304Pardo "River of · goldGrade: 1.2Grade Unit: g/tIntercept: 0.38 mView all detailsHide details
Identity
- Hole ID
- PD-26-304
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.2
- Grade Unit
- g/t
- Intercept
- 0.38 m
- True Width
- 0.38 m
- From
- 30.96 m
- To
- 31.34 m
- Hole Depth
- 38.5 m
- Intercept Depth
- 28.74 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-304:30.96-31.34
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555837
- Northing
- 5183190
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.20”
Context: 0.38
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-305Pardo "River of · goldGrade: 0.81Grade Unit: g/tIntercept: 2.95 mView all detailsHide details
Identity
- Hole ID
- PD-26-305
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 2.95 m
- True Width
- 2.95 m
- From
- 30.47 m
- To
- 33.42 m
- Hole Depth
- 41.5 m
- Intercept Depth
- 30.47 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-305:30.47-33.42
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555839
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade intercept contributing to the understanding of the deposit, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.81”
Context: 2.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-305Pardo "River of · goldGrade: 1.33Grade Unit: g/tIntercept: 1.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-305
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.33
- Grade Unit
- g/t
- Intercept
- 1.42 m
- True Width
- 1.42 m
- From
- 32 m
- To
- 33.42 m
- Hole Depth
- 41.5 m
- Intercept Depth
- 30.47 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-305:32-33.42
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555839
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.33”
Context: 1.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-305Pardo "River of · goldGrade: 2.58Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-305
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.58
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 32.42 m
- To
- 32.92 m
- Hole Depth
- 41.5 m
- Intercept Depth
- 30.47 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-305:32.42-32.92
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555839
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.58”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-306Pardo "River of · goldGrade: 0.48Grade Unit: g/tIntercept: 4.88 mView all detailsHide details
Identity
- Hole ID
- PD-26-306
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 4.88 m
- True Width
- 4.88 m
- From
- 28.5 m
- To
- 33.38 m
- Hole Depth
- 36.5 m
- Intercept Depth
- 28.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-306:28.5-33.38
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555837
- Northing
- 5183251
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A low-grade intercept, but contributes to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.48”
Context: 4.88
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.88
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-306Pardo "River of · goldGrade: 0.7Grade Unit: g/tIntercept: 2.58 mView all detailsHide details
Identity
- Hole ID
- PD-26-306
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 2.58 m
- True Width
- 2.58 m
- From
- 29.92 m
- To
- 32.5 m
- Hole Depth
- 36.5 m
- Intercept Depth
- 28.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-306:29.92-32.5
- Mining Method
- open_pit
Location
- Location
- MaC
- Easting
- 555837
- Northing
- 5183251
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.70”
Context: 2.58
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.58
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-308Pardo "River of · goldGrade: 0.2Grade Unit: g/tIntercept: 7.22 mView all detailsHide details
Identity
- Hole ID
- PD-26-308
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 7.22 m
- True Width
- 7.22 m
- From
- 2.67 m
- To
- 9.89 m
- Hole Depth
- 56.5 m
- Intercept Depth
- 2.67 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-308:2.67-9.89
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555909
- Northing
- 5183272
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.20”
Context: 7.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.22
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-308Pardo "River of · goldGrade: 0.2Grade Unit: g/tIntercept: 2.44 mView all detailsHide details
Identity
- Hole ID
- PD-26-308
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 2.44 m
- True Width
- 2.44 m
- From
- 12.24 m
- To
- 14.68 m
- Hole Depth
- 56.5 m
- Intercept Depth
- 2.67 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-308:12.24-14.68
- Mining Method
- open_pit
Location
- Location
- MiBS
- Easting
- 555909
- Northing
- 5183272
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.20”
Context: 2.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-309Pardo "River of · goldGrade: 0.25Grade Unit: g/tIntercept: 4.15 mView all detailsHide details
Identity
- Hole ID
- PD-26-309
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 4.15 m
- True Width
- 4.15 m
- From
- 3.63 m
- To
- 7.78 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 3.63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-309:3.63-7.78
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555896
- Northing
- 5183219
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.25”
Context: 4.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-312Pardo "River of · goldGrade: 0.35Grade Unit: g/tIntercept: 3.61 mView all detailsHide details
Identity
- Hole ID
- PD-26-312
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 3.61 m
- True Width
- 3.61 m
- From
- 0.64 m
- To
- 4.25 m
- Hole Depth
- 47.5 m
- Intercept Depth
- 0.64 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-312:0.64-4.25
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555951
- Northing
- 5183109
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.35”
Context: 3.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.61
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-313Pardo "River of · goldGrade: 0.23Grade Unit: g/tIntercept: 4.8 mView all detailsHide details
Identity
- Hole ID
- PD-26-313
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 4.8 m
- True Width
- 4.8 m
- From
- 0.23 m
- To
- 5.03 m
- Hole Depth
- 49 m
- Intercept Depth
- 0.23 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-313:0.23-5.03
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555955
- Northing
- 5183159
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.23”
Context: 4.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-314Pardo "River of · goldGrade: 0.24Grade Unit: g/tIntercept: 5.63 mView all detailsHide details
Identity
- Hole ID
- PD-26-314
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 5.63 m
- True Width
- 5.63 m
- From
- 0.68 m
- To
- 6.31 m
- Hole Depth
- 58 m
- Intercept Depth
- 0.68 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-314:0.68-6.31
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555956
- Northing
- 5183220
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.24”
Context: 5.63
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.63
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-315Pardo "River of · goldGrade: 0.16Grade Unit: g/tIntercept: 8.45 mView all detailsHide details
Identity
- Hole ID
- PD-26-315
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 8.45 m
- True Width
- 8.45 m
- From
- 0.31 m
- To
- 8.76 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 0.31 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-315:0.31-8.76
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555967
- Northing
- 5183275
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.16”
Context: 8.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-315Pardo "River of · goldGrade: 0.37Grade Unit: g/tIntercept: 1.43 mView all detailsHide details
Identity
- Hole ID
- PD-26-315
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.37
- Grade Unit
- g/t
- Intercept
- 1.43 m
- True Width
- 1.43 m
- From
- 13.45 m
- To
- 14.88 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 0.31 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-315:13.45-14.88
- Mining Method
- open_pit
Location
- Location
- MiBS
- Easting
- 555967
- Northing
- 5183275
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.37”
Context: 1.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.43
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-315Pardo "River of · goldGrade: 0.28Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- PD-26-315
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 3 m
- From
- 25.7 m
- To
- 28.7 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 0.31 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-315:25.7-28.7
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555967
- Northing
- 5183275
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.28”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-316Pardo "River of · goldGrade: 0.2Grade Unit: g/tIntercept: 7.28 mView all detailsHide details
Identity
- Hole ID
- PD-26-316
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 7.28 m
- True Width
- 7.28 m
- From
- 0.15 m
- To
- 7.43 m
- Hole Depth
- 49 m
- Intercept Depth
- 0.15 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-316:0.15-7.43
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555983
- Northing
- 5183176
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.20”
Context: 7.28
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.28
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-316Pardo "River of · goldGrade: 0.72Grade Unit: g/tIntercept: 1.84 mView all detailsHide details
Identity
- Hole ID
- PD-26-316
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.72
- Grade Unit
- g/t
- Intercept
- 1.84 m
- True Width
- 1.84 m
- From
- 19 m
- To
- 20.84 m
- Hole Depth
- 49 m
- Intercept Depth
- 0.15 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-316:19-20.84
- Mining Method
- open_pit
Location
- Location
- MiBS
- Easting
- 555983
- Northing
- 5183176
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.72”
Context: 1.84
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.84
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-316Pardo "River of · goldGrade: 0.32Grade Unit: g/tIntercept: 4.21 mView all detailsHide details
Identity
- Hole ID
- PD-26-316
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 4.21 m
- True Width
- 4.21 m
- From
- 25.03 m
- To
- 29.24 m
- Hole Depth
- 49 m
- Intercept Depth
- 0.15 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-316:25.03-29.24
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555983
- Northing
- 5183176
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.32”
Context: 4.21
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.21
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-316Pardo "River of · goldGrade: 0.22Grade Unit: g/tIntercept: 2.47 mView all detailsHide details
Identity
- Hole ID
- PD-26-316
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 2.47 m
- True Width
- 2.47 m
- From
- 31.75 m
- To
- 34.22 m
- Hole Depth
- 49 m
- Intercept Depth
- 0.15 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-316:31.75-34.22
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555983
- Northing
- 5183176
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.22”
Context: 2.47
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.47
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-317Pardo "River of · goldGrade: 0.24Grade Unit: g/tIntercept: 1.87 mView all detailsHide details
Identity
- Hole ID
- PD-26-317
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 1.87 m
- True Width
- 1.87 m
- From
- 0.5 m
- To
- 2.37 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-317:0.5-2.37
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 555991
- Northing
- 5183234
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.24”
Context: 1.87
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.87
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-317Pardo "River of · goldGrade: 0.32Grade Unit: g/tIntercept: 2.45 mView all detailsHide details
Identity
- Hole ID
- PD-26-317
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 2.45 m
- True Width
- 2.45 m
- From
- 29.76 m
- To
- 32.21 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-317:29.76-32.21
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555991
- Northing
- 5183234
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.32”
Context: 2.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-317Pardo "River of · goldGrade: 0.46Grade Unit: g/tIntercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- PD-26-317
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 3.71 m
- True Width
- 3.71 m
- From
- 37.1 m
- To
- 40.81 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-317:37.1-40.81
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555991
- Northing
- 5183234
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.46”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.71
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-317Pardo "River of · goldGrade: 1.21Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- PD-26-317
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.21
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 1 m
- From
- 39.5 m
- To
- 40.5 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-317:39.5-40.5
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 555991
- Northing
- 5183234
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.21”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-318Pardo "River of · goldGrade: 0.23Grade Unit: g/tIntercept: 6.08 mView all detailsHide details
Identity
- Hole ID
- PD-26-318
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 6.08 m
- True Width
- 6.08 m
- From
- 0.75 m
- To
- 6.83 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-318:0.75-6.83
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556002
- Northing
- 5183259
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.23”
Context: 6.08
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.08
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-318Pardo "River of · goldGrade: 0.21Grade Unit: g/tIntercept: 4.89 mView all detailsHide details
Identity
- Hole ID
- PD-26-318
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 4.89 m
- True Width
- 4.89 m
- From
- 25.61 m
- To
- 30.5 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-318:25.61-30.5
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556002
- Northing
- 5183259
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.21”
Context: 4.89
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.89
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-318Pardo "River of · goldGrade: 0.55Grade Unit: g/tIntercept: 3.23 mView all detailsHide details
Identity
- Hole ID
- PD-26-318
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 3.23 m
- True Width
- 3.23 m
- From
- 37.86 m
- To
- 41.09 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-318:37.86-41.09
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556002
- Northing
- 5183259
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.55”
Context: 3.23
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-318Pardo "River of · goldGrade: 1.47Grade Unit: g/tIntercept: 0.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-318
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.47
- Grade Unit
- g/t
- Intercept
- 0.42 m
- True Width
- 0.42 m
- From
- 38.82 m
- To
- 39.24 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-318:38.82-39.24
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556002
- Northing
- 5183259
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.47”
Context: 0.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-319Pardo "River of · goldGrade: 0.23Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- PD-26-319
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 8 m
- From
- 0.5 m
- To
- 8.5 m
- Hole Depth
- 46 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-319:0.5-8.5
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556025
- Northing
- 5183319
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.23”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-319Pardo "River of · goldGrade: 0.23Grade Unit: g/tIntercept: 11.49 mView all detailsHide details
Identity
- Hole ID
- PD-26-319
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 11.49 m
- True Width
- 11.49 m
- From
- 31.61 m
- To
- 43.1 m
- Hole Depth
- 46 m
- Intercept Depth
- 0.5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-319:31.61-43.1
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556025
- Northing
- 5183319
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.23”
Context: 11.49
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 11.49
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-320Pardo "River of · goldGrade: 0.32Grade Unit: g/tIntercept: 4.67 mView all detailsHide details
Identity
- Hole ID
- PD-26-320
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 4.67 m
- True Width
- 4.67 m
- From
- 0.66 m
- To
- 5.33 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.66 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-320:0.66-5.33
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556016
- Northing
- 5183284
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.32”
Context: 4.67
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.67
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-320Pardo "River of · goldGrade: 1.23Grade Unit: g/tIntercept: 2.83 mView all detailsHide details
Identity
- Hole ID
- PD-26-320
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.23
- Grade Unit
- g/t
- Intercept
- 2.83 m
- True Width
- 2.83 m
- From
- 37.9 m
- To
- 40.73 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.66 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-320:37.9-40.73
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556016
- Northing
- 5183284
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.23”
Context: 2.83
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.83
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-320Pardo "River of · goldGrade: 2.44Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- PD-26-320
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.44
- Grade Unit
- g/t
- Intercept
- 1.35 m
- True Width
- 1.35 m
- From
- 39.38 m
- To
- 40.73 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.66 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-320:39.38-40.73
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556016
- Northing
- 5183284
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.44”
Context: 1.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.35
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-320Pardo "River of · goldGrade: 5.21Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-320
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 5.21
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 40.23 m
- To
- 40.73 m
- Hole Depth
- 43 m
- Intercept Depth
- 0.66 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-320:40.23-40.73
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556016
- Northing
- 5183284
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“5.21”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-322Pardo "River of · goldGrade: 0.32Grade Unit: g/tIntercept: 5.47 mView all detailsHide details
Identity
- Hole ID
- PD-26-322
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 5.47 m
- True Width
- 5.47 m
- From
- 5.4 m
- To
- 10.87 m
- Hole Depth
- 19 m
- Intercept Depth
- 5.4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-322:5.4-10.87
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556023
- Northing
- 5183135
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.32”
Context: 5.47
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.47
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-322Pardo "River of · goldGrade: 1.6Grade Unit: g/tIntercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PD-26-322
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.6
- Grade Unit
- g/t
- Intercept
- 1.61 m
- True Width
- 1.61 m
- From
- 15.78 m
- To
- 17.39 m
- Hole Depth
- 19 m
- Intercept Depth
- 5.4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-322:15.78-17.39
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556023
- Northing
- 5183135
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.60”
Context: 1.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.61
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-322Pardo "River of · goldGrade: 2.62Grade Unit: g/tIntercept: 0.77 mView all detailsHide details
Identity
- Hole ID
- PD-26-322
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.62
- Grade Unit
- g/t
- Intercept
- 0.77 m
- True Width
- 0.77 m
- From
- 16.23 m
- To
- 17 m
- Hole Depth
- 19 m
- Intercept Depth
- 5.4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-322:16.23-17
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556023
- Northing
- 5183135
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.62”
Context: 0.77
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.77
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-323Pardo "River of · goldGrade: 0.26Grade Unit: g/tIntercept: 5.12 mView all detailsHide details
Identity
- Hole ID
- PD-26-323
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 5.12 m
- True Width
- 5.12 m
- From
- 9.62 m
- To
- 14.74 m
- Hole Depth
- 26.5 m
- Intercept Depth
- 9.62 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-323:9.62-14.74
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556012
- Northing
- 5183161
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.26”
Context: 5.12
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-323Pardo "River of · goldGrade: 0.29Grade Unit: g/tIntercept: 3.31 mView all detailsHide details
Identity
- Hole ID
- PD-26-323
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 3.31 m
- True Width
- 3.31 m
- From
- 22.25 m
- To
- 25.56 m
- Hole Depth
- 26.5 m
- Intercept Depth
- 9.62 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-323:22.25-25.56
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556012
- Northing
- 5183161
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.29”
Context: 3.31
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-324Pardo "River of · goldGrade: 1.05Grade Unit: g/tIntercept: 8.25 mView all detailsHide details
Identity
- Hole ID
- PD-26-324
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.05
- Grade Unit
- g/t
- Intercept
- 8.25 m
- True Width
- 8.25 m
- From
- 14.3 m
- To
- 22.55 m
- Hole Depth
- 25 m
- Intercept Depth
- 14.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-324:14.3-22.55
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556037
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, moderate-width shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.05”
Context: 8.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.25
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-324Pardo "River of · goldGrade: 3.01Grade Unit: g/tIntercept: 2.55 mView all detailsHide details
Identity
- Hole ID
- PD-26-324
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.01
- Grade Unit
- g/t
- Intercept
- 2.55 m
- True Width
- 2.55 m
- From
- 20 m
- To
- 22.55 m
- Hole Depth
- 25 m
- Intercept Depth
- 14.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-324:20-22.55
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556037
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.01”
Context: 2.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.55
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-324Pardo "River of · goldGrade: 9.49Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- PD-26-324
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 9.49
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.44 m
- From
- 20.93 m
- To
- 21.37 m
- Hole Depth
- 25 m
- Intercept Depth
- 14.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-324:20.93-21.37
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556037
- Northing
- 5183221
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“9.49”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-325Pardo "River of · goldGrade: 0.3Grade Unit: g/tIntercept: 5.03 mView all detailsHide details
Identity
- Hole ID
- PD-26-325
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 5.03 m
- True Width
- 5.03 m
- From
- 14.52 m
- To
- 19.55 m
- Hole Depth
- 23.5 m
- Intercept Depth
- 14.52 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-325:14.52-19.55
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556058
- Northing
- 5183262
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.30”
Context: 5.03
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.03
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-326Pardo "River of · goldGrade: 0.76Grade Unit: g/tIntercept: 3.38 mView all detailsHide details
Identity
- Hole ID
- PD-26-326
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.76
- Grade Unit
- g/t
- Intercept
- 3.38 m
- True Width
- 3.38 m
- From
- 6.7 m
- To
- 10.08 m
- Hole Depth
- 12 m
- Intercept Depth
- 6.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-326:6.7-10.08
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556335
- Northing
- 5183448
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.76”
Context: 3.38
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-326Pardo "River of · goldGrade: 1.26Grade Unit: g/tIntercept: 1.46 mView all detailsHide details
Identity
- Hole ID
- PD-26-326
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 1.46 m
- True Width
- 1.46 m
- From
- 8.62 m
- To
- 10.08 m
- Hole Depth
- 12 m
- Intercept Depth
- 6.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-326:8.62-10.08
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556335
- Northing
- 5183448
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.26”
Context: 1.46
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.46
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-326Pardo "River of · goldGrade: 3.26Grade Unit: g/tIntercept: 0.36 mView all detailsHide details
Identity
- Hole ID
- PD-26-326
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.26
- Grade Unit
- g/t
- Intercept
- 0.36 m
- True Width
- 0.36 m
- From
- 9.72 m
- To
- 10.08 m
- Hole Depth
- 12 m
- Intercept Depth
- 6.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-326:9.72-10.08
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556335
- Northing
- 5183448
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.26”
Context: 0.36
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.36
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-327Pardo "River of · goldGrade: 0.63Grade Unit: g/tIntercept: 4.61 mView all detailsHide details
Identity
- Hole ID
- PD-26-327
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 4.61 m
- True Width
- 4.61 m
- From
- 7.65 m
- To
- 12.26 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.65 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-327:7.65-12.26
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556320
- Northing
- 5183449
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.63”
Context: 4.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.61
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-327Pardo "River of · goldGrade: 1.43Grade Unit: g/tIntercept: 1.76 mView all detailsHide details
Identity
- Hole ID
- PD-26-327
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.43
- Grade Unit
- g/t
- Intercept
- 1.76 m
- True Width
- 1.76 m
- From
- 10.5 m
- To
- 12.26 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.65 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-327:10.5-12.26
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556320
- Northing
- 5183449
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.43”
Context: 1.76
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.76
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-327Pardo "River of · goldGrade: 3.83Grade Unit: g/tIntercept: 0.43 mView all detailsHide details
Identity
- Hole ID
- PD-26-327
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.83
- Grade Unit
- g/t
- Intercept
- 0.43 m
- True Width
- 0.43 m
- From
- 11 m
- To
- 11.43 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.65 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-327:11-11.43
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556320
- Northing
- 5183449
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.83”
Context: 0.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.43
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-328Pardo "River of · goldGrade: 1.02Grade Unit: g/tIntercept: 2.39 mView all detailsHide details
Identity
- Hole ID
- PD-26-328
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 2.39 m
- True Width
- 2.39 m
- From
- 9.76 m
- To
- 12.15 m
- Hole Depth
- 15.29 m
- Intercept Depth
- 9.76 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-328:9.76-12.15
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556321
- Northing
- 5183432
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.02”
Context: 2.39
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.39
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-328Pardo "River of · goldGrade: 2.71Grade Unit: g/tIntercept: 0.64 mView all detailsHide details
Identity
- Hole ID
- PD-26-328
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.71
- Grade Unit
- g/t
- Intercept
- 0.64 m
- True Width
- 0.64 m
- From
- 11.16 m
- To
- 11.8 m
- Hole Depth
- 15.29 m
- Intercept Depth
- 9.76 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-328:11.16-11.8
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556321
- Northing
- 5183432
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.71”
Context: 0.64
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.64
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-329Pardo "River of · goldGrade: 0.7Grade Unit: g/tIntercept: 2.44 mView all detailsHide details
Identity
- Hole ID
- PD-26-329
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 2.44 m
- True Width
- 2.44 m
- From
- 6.89 m
- To
- 9.33 m
- Hole Depth
- 15 m
- Intercept Depth
- 6.89 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-329:6.89-9.33
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556337
- Northing
- 5183419
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.70”
Context: 2.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-329Pardo "River of · goldGrade: 1.34Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- PD-26-329
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.34
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.44 m
- From
- 8.89 m
- To
- 9.33 m
- Hole Depth
- 15 m
- Intercept Depth
- 6.89 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-329:8.89-9.33
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556337
- Northing
- 5183419
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.34”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-332Pardo "River of · goldGrade: 2.48Grade Unit: g/tIntercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- PD-26-332
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.48
- Grade Unit
- g/t
- Intercept
- 3.71 m
- True Width
- 3.71 m
- From
- 7.95 m
- To
- 11.66 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.95 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-332:7.95-11.66
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556291
- Northing
- 5183347
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.48”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.71
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-332Pardo "River of · goldGrade: 8.44Grade Unit: g/tIntercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- PD-26-332
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 8.44
- Grade Unit
- g/t
- Intercept
- 0.97 m
- True Width
- 0.97 m
- From
- 9.24 m
- To
- 10.21 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.95 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-332:9.24-10.21
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556291
- Northing
- 5183347
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“8.44”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-332Pardo "River of · goldGrade: 12.61Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-332
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 12.61
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 9.24 m
- To
- 9.74 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 7.95 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-332:9.24-9.74
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556291
- Northing
- 5183347
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“12.61”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-333Pardo "River of · goldGrade: 2.03Grade Unit: g/tIntercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-333
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.03
- Grade Unit
- g/t
- Intercept
- 2.42 m
- True Width
- 2.42 m
- From
- 4 m
- To
- 6.42 m
- Hole Depth
- 11.5 m
- Intercept Depth
- 4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-333:4-6.42
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556443
- Northing
- 5183206
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.03”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-333Pardo "River of · goldGrade: 4.02Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- PD-26-333
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 4.02
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 1 m
- From
- 4.93 m
- To
- 5.93 m
- Hole Depth
- 11.5 m
- Intercept Depth
- 4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-333:4.93-5.93
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556443
- Northing
- 5183206
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“4.02”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-333Pardo "River of · goldGrade: 5.74Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-333
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 5.74
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 4.93 m
- To
- 5.43 m
- Hole Depth
- 11.5 m
- Intercept Depth
- 4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-333:4.93-5.43
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556443
- Northing
- 5183206
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“5.74”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-335Pardo "River of · goldGrade: 1.86Grade Unit: g/tIntercept: 1.09 mView all detailsHide details
Identity
- Hole ID
- PD-26-335
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.86
- Grade Unit
- g/t
- Intercept
- 1.09 m
- True Width
- 1.09 m
- From
- 5.4 m
- To
- 6.49 m
- Hole Depth
- 10 m
- Intercept Depth
- 5.4 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-335:5.4-6.49
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556512
- Northing
- 5183213
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.86”
Context: 1.09
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-337Pardo "River of · goldGrade: 0.25Grade Unit: g/tIntercept: 3.58 mView all detailsHide details
Identity
- Hole ID
- PD-26-337
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 3.58 m
- True Width
- 3.58 m
- From
- 9.3 m
- To
- 12.88 m
- Hole Depth
- 43.16 m
- Intercept Depth
- 9.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-337:9.3-12.88
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556667
- Northing
- 5183323
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.25”
Context: 3.58
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.58
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-337Pardo "River of · goldGrade: 0.4Grade Unit: g/tIntercept: 4.28 mView all detailsHide details
Identity
- Hole ID
- PD-26-337
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 4.28 m
- True Width
- 4.28 m
- From
- 29 m
- To
- 33.28 m
- Hole Depth
- 43.16 m
- Intercept Depth
- 9.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-337:29-33.28
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556667
- Northing
- 5183323
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.40”
Context: 4.28
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.28
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-337Pardo "River of · goldGrade: 1.29Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-337
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.29
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 29.5 m
- To
- 30 m
- Hole Depth
- 43.16 m
- Intercept Depth
- 9.3 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-337:29.5-30
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556667
- Northing
- 5183323
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.29”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-338Pardo "River of · goldGrade: 0.33Grade Unit: g/tIntercept: 2.54 mView all detailsHide details
Identity
- Hole ID
- PD-26-338
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.33
- Grade Unit
- g/t
- Intercept
- 2.54 m
- True Width
- 2.54 m
- From
- 6 m
- To
- 8.54 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 6 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-338:6-8.54
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556599
- Northing
- 5183237
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.33”
Context: 2.54
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.54
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-338Pardo "River of · goldGrade: 0.3Grade Unit: g/tIntercept: 3.98 mView all detailsHide details
Identity
- Hole ID
- PD-26-338
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 3.98 m
- True Width
- 3.98 m
- From
- 30.12 m
- To
- 34.1 m
- Hole Depth
- 44.5 m
- Intercept Depth
- 6 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-338:30.12-34.1
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556599
- Northing
- 5183237
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.30”
Context: 3.98
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.98
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-339Pardo "River of · goldGrade: 0.4Grade Unit: g/tIntercept: 3.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-339
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 3.42 m
- True Width
- 3.42 m
- From
- 28.9 m
- To
- 32.32 m
- Hole Depth
- 47 m
- Intercept Depth
- 28.9 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-339:28.9-32.32
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556663
- Northing
- 5183277
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.40”
Context: 3.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-339Pardo "River of · goldGrade: 1.85Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- PD-26-339
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.85
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.44 m
- From
- 31.88 m
- To
- 32.32 m
- Hole Depth
- 47 m
- Intercept Depth
- 28.9 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-339:31.88-32.32
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556663
- Northing
- 5183277
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.85”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-342Pardo "River of · goldGrade: 0.34Grade Unit: g/tIntercept: 1.93 mView all detailsHide details
Identity
- Hole ID
- PD-26-342
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1.93 m
- True Width
- 1.93 m
- From
- 3.03 m
- To
- 4.96 m
- Hole Depth
- 49 m
- Intercept Depth
- 3.03 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-342:3.03-4.96
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556627
- Northing
- 5183196
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the overall understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.34”
Context: 1.93
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.93
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-345Pardo "River of · goldGrade: 1.71Grade Unit: g/tIntercept: 1.43 mView all detailsHide details
Identity
- Hole ID
- PD-26-345
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 1.43 m
- True Width
- 1.43 m
- From
- 3.35 m
- To
- 4.78 m
- Hole Depth
- 7.5 m
- Intercept Depth
- 3.35 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-345:3.35-4.78
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556485
- Northing
- 5183353
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.71”
Context: 1.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.43
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-345Pardo "River of · goldGrade: 3.56Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PD-26-345
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.56
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.5 m
- From
- 3.35 m
- To
- 3.85 m
- Hole Depth
- 7.5 m
- Intercept Depth
- 3.35 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-345:3.35-3.85
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556485
- Northing
- 5183353
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.56”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-348Pardo "River of · goldGrade: 4.96Grade Unit: g/tIntercept: 2.09 mView all detailsHide details
Identity
- Hole ID
- PD-26-348
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 4.96
- Grade Unit
- g/t
- Intercept
- 2.09 m
- True Width
- 2.09 m
- From
- 2.72 m
- To
- 4.81 m
- Hole Depth
- 10.5 m
- Intercept Depth
- 2.72 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-348:2.72-4.81
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556497
- Northing
- 5183338
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“4.96”
Context: 2.09
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-348Pardo "River of · goldGrade: 30.04Grade Unit: g/tIntercept: 0.33 mView all detailsHide details
Identity
- Hole ID
- PD-26-348
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 30.04
- Grade Unit
- g/t
- Intercept
- 0.33 m
- True Width
- 0.33 m
- From
- 2.72 m
- To
- 3.05 m
- Hole Depth
- 10.5 m
- Intercept Depth
- 2.72 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-348:2.72-3.05
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556497
- Northing
- 5183338
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“30.04”
Context: 0.33
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.33
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-349Pardo "River of · goldGrade: 0.95Grade Unit: g/tIntercept: 0.93 mView all detailsHide details
Identity
- Hole ID
- PD-26-349
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.95
- Grade Unit
- g/t
- Intercept
- 0.93 m
- True Width
- 0.93 m
- From
- 1.75 m
- To
- 2.68 m
- Hole Depth
- 7.5 m
- Intercept Depth
- 1.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-349:1.75-2.68
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556495
- Northing
- 5183318
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.95”
Context: 0.93
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.93
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-354Pardo "River of · goldGrade: 1.38Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- PD-26-354
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.38
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.75 m
- From
- 0 m
- To
- 0.75 m
- Hole Depth
- 5.5 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-354:0-0.75
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556455
- Northing
- 5183315
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.38”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-355Pardo "River of · goldGrade: 2.12Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- PD-26-355
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.12
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.75 m
- From
- 1 m
- To
- 1.75 m
- Hole Depth
- 4.5 m
- Intercept Depth
- 1 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-355:1-1.75
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556454
- Northing
- 5183304
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.12”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-356Pardo "River of · goldGrade: 1.02Grade Unit: g/tIntercept: 4.24 mView all detailsHide details
Identity
- Hole ID
- PD-26-356
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 4.24 m
- True Width
- 4.24 m
- From
- 0.71 m
- To
- 4.95 m
- Hole Depth
- 6 m
- Intercept Depth
- 0.71 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-356:0.71-4.95
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556455
- Northing
- 5183281
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.02”
Context: 4.24
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.24
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-356Pardo "River of · goldGrade: 2.34Grade Unit: g/tIntercept: 1.49 mView all detailsHide details
Identity
- Hole ID
- PD-26-356
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.34
- Grade Unit
- g/t
- Intercept
- 1.49 m
- True Width
- 1.49 m
- From
- 2.95 m
- To
- 4.44 m
- Hole Depth
- 6 m
- Intercept Depth
- 0.71 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-356:2.95-4.44
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556455
- Northing
- 5183281
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.34”
Context: 1.49
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.49
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-356Pardo "River of · goldGrade: 6.13Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- PD-26-356
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 6.13
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.3 m
- From
- 3.31 m
- To
- 3.61 m
- Hole Depth
- 6 m
- Intercept Depth
- 0.71 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-356:3.31-3.61
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556455
- Northing
- 5183281
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“6.13”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-357Pardo "River of · goldGrade: 0.41Grade Unit: g/tIntercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-357
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 2.42 m
- True Width
- 2.42 m
- From
- 1.25 m
- To
- 3.67 m
- Hole Depth
- 7.5 m
- Intercept Depth
- 1.25 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-357:1.25-3.67
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556453
- Northing
- 5183290
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.41”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-358Pardo "River of · goldGrade: 1.88Grade Unit: g/tIntercept: 1.42 mView all detailsHide details
Identity
- Hole ID
- PD-26-358
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.88
- Grade Unit
- g/t
- Intercept
- 1.42 m
- True Width
- 1.42 m
- From
- 8.7 m
- To
- 10.12 m
- Hole Depth
- 12 m
- Intercept Depth
- 8.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-358:8.7-10.12
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556205
- Northing
- 5183370
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.88”
Context: 1.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-358Pardo "River of · goldGrade: 3.14Grade Unit: g/tIntercept: 0.79 mView all detailsHide details
Identity
- Hole ID
- PD-26-358
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.14
- Grade Unit
- g/t
- Intercept
- 0.79 m
- True Width
- 0.79 m
- From
- 9.33 m
- To
- 10.12 m
- Hole Depth
- 12 m
- Intercept Depth
- 8.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-358:9.33-10.12
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556205
- Northing
- 5183370
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.14”
Context: 0.79
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.79
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-358Pardo "River of · goldGrade: 4.96Grade Unit: g/tIntercept: 0.39 mView all detailsHide details
Identity
- Hole ID
- PD-26-358
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 4.96
- Grade Unit
- g/t
- Intercept
- 0.39 m
- True Width
- 0.39 m
- From
- 9.73 m
- To
- 10.12 m
- Hole Depth
- 12 m
- Intercept Depth
- 8.7 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-358:9.73-10.12
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556205
- Northing
- 5183370
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“4.96”
Context: 0.39
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.39
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-359Pardo "River of · goldGrade: 1.38Grade Unit: g/tIntercept: 4.78 mView all detailsHide details
Identity
- Hole ID
- PD-26-359
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.38
- Grade Unit
- g/t
- Intercept
- 4.78 m
- True Width
- 4.78 m
- From
- 5.48 m
- To
- 10.26 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 5.48 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-359:5.48-10.26
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556175
- Northing
- 5183376
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.38”
Context: 4.78
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-359Pardo "River of · goldGrade: 2.6Grade Unit: g/tIntercept: 2.35 mView all detailsHide details
Identity
- Hole ID
- PD-26-359
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.6
- Grade Unit
- g/t
- Intercept
- 2.35 m
- True Width
- 2.35 m
- From
- 7.07 m
- To
- 9.42 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 5.48 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-359:7.07-9.42
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556175
- Northing
- 5183376
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.60”
Context: 2.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.35
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-359Pardo "River of · goldGrade: 6.27Grade Unit: g/tIntercept: 0.43 mView all detailsHide details
Identity
- Hole ID
- PD-26-359
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 6.27
- Grade Unit
- g/t
- Intercept
- 0.43 m
- True Width
- 0.43 m
- From
- 7.07 m
- To
- 7.5 m
- Hole Depth
- 13.5 m
- Intercept Depth
- 5.48 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-359:7.07-7.5
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556175
- Northing
- 5183376
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: An exceptional-grade sub-interval, indicating bonanza-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“6.27”
Context: 0.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.43
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-362Pardo "River of · goldGrade: 0.51Grade Unit: g/tIntercept: 1.63 mView all detailsHide details
Identity
- Hole ID
- PD-26-362
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.51
- Grade Unit
- g/t
- Intercept
- 1.63 m
- True Width
- 1.63 m
- From
- 11.6 m
- To
- 13.23 m
- Hole Depth
- 17 m
- Intercept Depth
- 11.6 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-362:11.6-13.23
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556162
- Northing
- 5183407
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.51”
Context: 1.63
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.63
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-362Pardo "River of · goldGrade: 1.73Grade Unit: g/tIntercept: 0.31 mView all detailsHide details
Identity
- Hole ID
- PD-26-362
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.73
- Grade Unit
- g/t
- Intercept
- 0.31 m
- True Width
- 0.31 m
- From
- 12.45 m
- To
- 12.76 m
- Hole Depth
- 17 m
- Intercept Depth
- 11.6 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-362:12.45-12.76
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556162
- Northing
- 5183407
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.73”
Context: 0.31
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-363Pardo "River of · goldGrade: 1.08Grade Unit: g/tIntercept: 2.57 mView all detailsHide details
Identity
- Hole ID
- PD-26-363
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
- Intercept
- 2.57 m
- True Width
- 2.57 m
- From
- 9.75 m
- To
- 12.32 m
- Hole Depth
- 16.5 m
- Intercept Depth
- 9.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-363:9.75-12.32
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556146
- Northing
- 5183411
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A moderate-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“1.08”
Context: 2.57
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-363Pardo "River of · goldGrade: 3.57Grade Unit: g/tIntercept: 0.35 mView all detailsHide details
Identity
- Hole ID
- PD-26-363
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 3.57
- Grade Unit
- g/t
- Intercept
- 0.35 m
- True Width
- 0.35 m
- From
- 10.15 m
- To
- 10.5 m
- Hole Depth
- 16.5 m
- Intercept Depth
- 9.75 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-363:10.15-10.5
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556146
- Northing
- 5183411
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“3.57”
Context: 0.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.35
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-364Pardo "River of · goldGrade: 0.41Grade Unit: g/tIntercept: 2.9 mView all detailsHide details
Identity
- Hole ID
- PD-26-364
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 2.9 m
- True Width
- 2.9 m
- From
- 9.29 m
- To
- 12.19 m
- Hole Depth
- 15 m
- Intercept Depth
- 9.29 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-364:9.29-12.19
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556162
- Northing
- 5183425
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.41”
Context: 2.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-365Pardo "River of · goldGrade: 0.26Grade Unit: g/tIntercept: 1.68 mView all detailsHide details
Identity
- Hole ID
- PD-26-365
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 1.68 m
- True Width
- 1.68 m
- From
- 2.97 m
- To
- 4.65 m
- Hole Depth
- 16.5 m
- Intercept Depth
- 2.97 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-365:2.97-4.65
- Mining Method
- open_pit
Location
- Location
- MiPC
- Easting
- 556146
- Northing
- 5183440
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A weak-grade, very shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“0.26”
Context: 1.68
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.68
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-365Pardo "River of · goldGrade: 2.23Grade Unit: g/tIntercept: 1.81 mView all detailsHide details
Identity
- Hole ID
- PD-26-365
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 2.23
- Grade Unit
- g/t
- Intercept
- 1.81 m
- True Width
- 1.81 m
- From
- 12.95 m
- To
- 14.76 m
- Hole Depth
- 16.5 m
- Intercept Depth
- 2.97 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-365:12.95-14.76
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556146
- Northing
- 5183440
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade, shallow intercept, contributing to the understanding of the deposit's bulk-tonnage potential, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“2.23”
Context: 1.81
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.81
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
PD-26-365Pardo "River of · goldGrade: 4Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- PD-26-365
- Project
- Pardo "River of
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- IVS.V
Geometry
- Grade
- 4
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.95 m
- From
- 13.81 m
- To
- 14.76 m
- Hole Depth
- 16.5 m
- Intercept Depth
- 2.97 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- PD-26-365:13.81-14.76
- Mining Method
- open_pit
Location
- Location
- MiBC
- Easting
- 556146
- Northing
- 5183440
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MSA Labs and Paragon Geochemical
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-23T00:00:00.000Z
Reasoning: A strong-grade sub-interval, indicating higher-grade zones within the broader mineralization, with true width disclosed and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Shallow Mineralization
Negative factors
- Cut-off Undisclosed
Evidence · table
“4.00”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.