Independence Gold Confirms Balrog Vein at Depth and Intercepts 3.11 g/t Gold and 48.69 g/t Silver over 8.03 Metres at the Tommy Vein, 3Ts Project, BC
Original announcement by orestocks on
- Company
- Independence Gold Corp.
- Ticker
- IGO.V
- Exchange
- Unavailable
- Region
- British Columbia
- Primary commodity
- Gold
- Secondary commodities
- Silver
- Document categories
- Drill results
- Extracted
- 2026-09-24 09:20:20 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Independence Gold Corp. announced drill results from its 3Ts Project in British Columbia, confirming the Balrog vein's continuity at depth and intersecting high-grade gold and silver at the Tommy vein. Hole 3TS-26-50 at Balrog extended mineralization below a microdiorite sill, while infill drilling at Tommy, including 8.03 metres at 3.11 g/t gold and 48.69 g/t silver, provided additional high-grade intercepts. The company plans further exploration and drilling in Q4 2026.
Reasoning: The drill results confirm the continuity of the Balrog vein at depth, which is a significant exploration success, and provide high-grade infill results for the Tommy vein, enhancing resource confidence. The disclosure of true widths and robust QA/QC procedures adds to the confidence in the results.
Positive factors
- Confirms depth extension of Balrog vein, opening up new exploration potential
- High-grade gold and silver intercepts in Tommy vein, supporting resource infill
- True width estimates provided for all reported intercepts
- Comprehensive QA/QC disclosure and QP sign-off
Negative factors
- Some intercepts are narrow and/or low-grade, particularly in Balrog vein
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 23
Classification and evidence
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document explicitly states estimated true widths for all reported intercepts (e.g., 'Estimated true width of 3TS-26-32 vein Is 57% of the reported interval').
Evidence · text
“Estimated true width of 3TS-26-32 vein Is 57% of the reported interval”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC procedures, including the use of an ISO/IEC 17025 accredited laboratory (SGS Canada Inc.), insertion of certified reference materials, blank samples, and field duplicates, and sign-off by a Qualified Person.
Evidence · text
“All drill core was logged, photographed, cut and sampled at the Company's secure core facility. Samples consist of (NQ) drill core with one half retained for reference material and one-half placed in sealed bags and shipped to SGS Canada Inc., an independent ISO/IEC 17025 accredited laboratory, for sample preparation and analysis. Sample preparation and all analytical work were completed at the SGS Burnaby facility. Gold analyses were completed using a 30-gram fire assay with atomic absorption spectrometry finish (GO_FAA30V10). Multi-element analyses, including silver, lead, zinc, copper and pathfinder elements, were determined by aqua regia digestion followed by ICP-AES analysis (GE_ICP21B20). Samples returning values above analytical limits are re-analyzed using appropriate over-limit methods where required. The Company's quality assurance and quality control (QA/QC) program includes the routine insertion of certified reference materials, blank samples and field duplicates into each sample batch. Internal laboratory quality control procedures, including the analysis of certified standards, blanks and duplicate samples, were also completed by SGS as part of its analytical program. Review of the QA/QC results indicates that analytical accuracy and precision are within acceptable limits, and the Qualified Person is satisfied that the reported assay data are suitable for disclosure. Qualified Person The scientific and technical information contained in this news release has been reviewed and approved by Andrew Randell, P.Geo., an independent consultant of the Company and a Qualified Person as defined by National Instrument 43-101 - Standards of Disclosure for Mineral Projects. Mr. Randell has verified the data disclosed in this press release, including the sampling, analytical and test data underlying this information that has been collected.”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: Hole 3TS-26-50 at the Balrog vein represents the first test at depth beneath the microdiorite sill, extending known mineralization and supporting vertical continuity.
Evidence · text
“Hole 3TS-26-50 represents the first test of the Balrog vein at depth beneath the microdiorite sill. The hole intersected five separate mineralized intervals between 83.20 and 110.23 m, including 1.20 m grading 2.24 grams per tonne ("g/t") gold and 21.67 g/t silver. These results extend the known Balrog vein mineralization below the sill and supports the interpreted vertical continuity of this vein system, which remains open at depth and along strike.”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: Holes 3TS-26-32 and 3TS-26-33 at the Tommy Vein were completed primarily as resource infill within the upper portion of the mineralized corridor.
Evidence · text
“Results were also received from holes 3TS-26-32 and 3TS-26-33 at the Tommy Vein. These shallow holes were completed primarily as resource infill within the upper portion of the Tommy mineralized corridor.”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The intercept of 0.44m at 22.91 g/t gold in hole 3TS-26-33 is an exceptionally high-grade zone for an epithermal gold deposit, well above the exceptional threshold of 15 g/t Au for underground epithermal deposits.
Evidence · table
“22.91”
Context: 0.44
Extracted facts
Stored fact records: 23. Some facts used in scoring do not have a stored record.
Drill Results (23)
3TS-26-323Ts · goldGrade: 3.89Grade Unit: g/tIntercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-32
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 3.89
- Grade Unit
- g/t
- Intercept
- 3.2 m
- True Width
- 1.824 m
- From
- 9.65 m
- To
- 12.85 m
- Hole Depth
- 101 m
- Intercept Depth
- 9.65 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-32:9.65-12.85
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 220 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept provides infill data for the Tommy vein with a moderate gold grade, contributing to resource confidence but not representing a new discovery. The grade is below the project average for gold.
Positive factors
- True width disclosed
- QA/QC disclosed
Negative factors
- Grade is below project average
- Infill drilling, lower novelty
Evidence · table
“3.89”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.824
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-323Ts · silverGrade: 35Grade Unit: g/tIntercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-32
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 35
- Grade Unit
- g/t
- Intercept
- 3.2 m
- True Width
- 1.824 m
- From
- 9.65 m
- To
- 12.85 m
- Hole Depth
- 101 m
- Intercept Depth
- 9.65 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-32:9.65-12.85
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 220 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept provides infill data for the Tommy vein with a moderate silver grade, contributing to resource confidence but not representing a new discovery. The grade is below the project average for silver.
Positive factors
- True width disclosed
- QA/QC disclosed
Negative factors
- Grade is below project average
- Infill drilling, lower novelty
Evidence · table
“35.00”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.824
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-323Ts · goldGrade: 19.62Grade Unit: g/tIntercept: 1.57 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-32
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 19.62
- Grade Unit
- g/t
- Intercept
- 1.57 m
- True Width
- 0.8949 m
- From
- 17 m
- To
- 18.57 m
- Hole Depth
- 101 m
- Intercept Depth
- 9.65 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-32:17-18.57
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 220 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept shows an exceptional gold grade for an epithermal deposit, significantly above the project average, providing strong infill data for the Tommy vein. The narrow width slightly reduces its overall materiality.
Positive factors
- Exceptional gold grade for epithermal deposit
- True width disclosed
- QA/QC disclosed
Negative factors
- Narrow intercept length
- Infill drilling, lower novelty
Evidence · table
“19.62”
Context: 1.57
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8949
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-323Ts · silverGrade: 84.71Grade Unit: g/tIntercept: 1.57 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-32
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 84.71
- Grade Unit
- g/t
- Intercept
- 1.57 m
- True Width
- 0.8949 m
- From
- 17 m
- To
- 18.57 m
- Hole Depth
- 101 m
- Intercept Depth
- 9.65 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-32:17-18.57
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 220 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept provides infill data for the Tommy vein with a strong silver grade, contributing to resource confidence. The grade is below the project average for silver.
Positive factors
- True width disclosed
- QA/QC disclosed
Negative factors
- Grade is below project average
- Narrow intercept length
- Infill drilling, lower novelty
Evidence · table
“84.71”
Context: 1.57
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8949
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-333Ts · goldGrade: 3.11Grade Unit: g/tIntercept: 8.03 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 3.11
- Grade Unit
- g/t
- Intercept
- 8.03 m
- True Width
- 4.015 m
- From
- 10.8 m
- To
- 18.83 m
- Hole Depth
- 104 m
- Intercept Depth
- 10.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-33:10.8-18.83
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This infill intercept at the Tommy vein shows a moderate gold grade over a good width, contributing positively to resource confidence. The grade is below the project average for gold.
Positive factors
- Moderate intercept length
- True width disclosed
- QA/QC disclosed
Negative factors
- Grade is below project average
- Infill drilling, lower novelty
Evidence · table
“3.11”
Context: 8.03
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.015
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-333Ts · silverGrade: 48.69Grade Unit: g/tIntercept: 8.03 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 48.69
- Grade Unit
- g/t
- Intercept
- 8.03 m
- True Width
- 4.015 m
- From
- 10.8 m
- To
- 18.83 m
- Hole Depth
- 104 m
- Intercept Depth
- 10.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-33:10.8-18.83
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This infill intercept at the Tommy vein shows a moderate silver grade over a good width, contributing positively to resource confidence. The grade is below the project average for silver.
Positive factors
- Moderate intercept length
- True width disclosed
- QA/QC disclosed
Negative factors
- Grade is below project average
- Infill drilling, lower novelty
Evidence · table
“48.69”
Context: 8.03
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.015
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-333Ts · goldGrade: 22.91Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 22.91
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.22 m
- From
- 12 m
- To
- 12.44 m
- Hole Depth
- 104 m
- Intercept Depth
- 10.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-33:12-12.44
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept shows a bonanza gold grade, significantly above the project average, providing strong infill data for the Tommy vein. The very narrow width limits its overall materiality but highlights high-grade potential.
Positive factors
- Bonanza gold grade for epithermal deposit
- True width disclosed
- QA/QC disclosed
Negative factors
- Very narrow intercept length
- Infill drilling, lower novelty
Evidence · table
“22.91”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.22
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-333Ts · silverGrade: 168.18Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 168.18
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.22 m
- From
- 12 m
- To
- 12.44 m
- Hole Depth
- 104 m
- Intercept Depth
- 10.8 m
Classification
- Deposit Type
- epithermal
- Program
- resource
- Sample Type
- drill
- Group ID
- 3TS-26-33:12-12.44
- Mining Method
- underground
Location
- Location
- Tommy
- Easting
- 363685
- Northing
- 5876740
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1197 m
- Azimuth
- 270 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade, above the project average, providing good infill data for the Tommy vein. The very narrow width limits its overall materiality.
Positive factors
- Strong silver grade for epithermal deposit
- True width disclosed
- QA/QC disclosed
Negative factors
- Very narrow intercept length
- Infill drilling, lower novelty
Evidence · table
“168.18”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.22
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
3TS-26-503Ts · goldGrade: 1.64Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 1.64
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.512 m
- From
- 83.2 m
- To
- 84 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:83.2-84
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of gold mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low gold grade
- Very narrow intercept length
Evidence · table
“1.64”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.512
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · silverGrade: 4.62Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 4.62
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.512 m
- From
- 83.2 m
- To
- 84 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:83.2-84
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of silver mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low silver grade
- Very narrow intercept length
Evidence · table
“4.62”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.512
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · goldGrade: 0.61Grade Unit: g/tIntercept: 2.7 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 2.7 m
- True Width
- 1.728 m
- From
- 95.3 m
- To
- 98 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:95.3-98
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while low-grade, is significant for confirming the presence of gold mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low gold grade
Evidence · table
“0.61”
Context: 2.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.728
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · silverGrade: 7.04Grade Unit: g/tIntercept: 2.7 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 7.04
- Grade Unit
- g/t
- Intercept
- 2.7 m
- True Width
- 1.728 m
- From
- 95.3 m
- To
- 98 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:95.3-98
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while low-grade, is significant for confirming the presence of silver mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low silver grade
Evidence · table
“7.04”
Context: 2.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.728
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · goldGrade: 1.04Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 1.04
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.64 m
- From
- 101 m
- To
- 102 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:101-102
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of gold mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low gold grade
- Narrow intercept length
Evidence · table
“1.04”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.64
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · silverGrade: 5Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 5
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.64 m
- From
- 101 m
- To
- 102 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:101-102
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of silver mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low silver grade
- Narrow intercept length
Evidence · table
“5.00”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.64
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · goldGrade: 0.54Grade Unit: g/tIntercept: 1.94 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 1.94 m
- True Width
- 1.2416 m
- From
- 106 m
- To
- 107.94 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:106-107.94
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while low-grade, is significant for confirming the presence of gold mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low gold grade
Evidence · table
“0.54”
Context: 1.94
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2416
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · goldGrade: 2.24Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 2.24
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 0.768 m
- From
- 109.03 m
- To
- 110.23 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:109.03-110.23
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of gold mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low gold grade
- Narrow intercept length
Evidence · table
“2.24”
Context: 1.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.768
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-503Ts · silverGrade: 21.67Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-50
- Project
- 3Ts
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 21.67
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 0.768 m
- From
- 109.03 m
- To
- 110.23 m
- Hole Depth
- 186.73 m
- Intercept Depth
- 83.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- 3TS-26-50:109.03-110.23
- Mining Method
- underground
Location
- Location
- Balrog
- Easting
- 362730
- Northing
- 5876875
- CRS
- NAD83, Zone 10 Datum
- Elevation
- 1175 m
- Azimuth
- 90 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: This intercept, while narrow and low-grade, is significant for confirming the presence of silver mineralization at depth in the Balrog vein, which is a new exploration target.
Positive factors
- Confirms mineralization at depth in a new area
- True width disclosed
- QA/QC disclosed
Negative factors
- Low silver grade
- Narrow intercept length
Evidence · table
“21.67”
Context: 1.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.768
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andand this first test beneath the microdiorite sill provides encouraging evidence that the mineralized · goldGrade: 84.71Grade Unit: g/tIntercept: 19.62 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- and this first test beneath the microdiorite sill provides encouraging evidence that the mineralized
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 84.71
- Grade Unit
- g/t
- Intercept
- 19.62 m
- From
- 18.57 m
- To
- 1.57 m
- Intercept Depth
- 18.57 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:18.57-1.57
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 84.71 g/t gold is exceptional against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1662.0 g/t·m is exceptional.
Positive factors
- 84.71 g/t gold is exceptional on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“84.71”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-333Ts · goldGrade: 48.69Grade Unit: g/tIntercept: 3.11 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 48.69
- Grade Unit
- g/t
- Intercept
- 3.11 m
- From
- 18.83 m
- To
- 8.03 m
- Intercept Depth
- 18.83 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- 3TS-26-33:18.83-8.03
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 48.69 g/t gold is exceptional against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 151.4 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 48.69 g/t gold is exceptional on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“48.69”
Context: 3TS-26-33
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
3TS-26-333Ts · goldGrade: 168.18Grade Unit: g/tIntercept: 22.91 mView all detailsHide details
Identity
- Hole ID
- 3TS-26-33
- Project
- 3Ts
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 168.18
- Grade Unit
- g/t
- Intercept
- 22.91 m
- From
- 12.44 m
- To
- 0.44 m
- Intercept Depth
- 12.44 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- 3TS-26-33:12.44-0.44
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 168.18 g/t gold is exceptional against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3853.0 g/t·m is exceptional.
Positive factors
- 168.18 g/t gold is exceptional on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“168.18”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andand this first test beneath the microdiorite sill provides encouraging evidence that the mineralized · goldGrade: 7.04Grade Unit: g/tIntercept: 0.61 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- and this first test beneath the microdiorite sill provides encouraging evidence that the mineralized
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 7.04
- Grade Unit
- g/t
- Intercept
- 0.61 m
- From
- 98 m
- To
- 2.7 m
- Intercept Depth
- 98 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:98-2.7
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 7.04 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 7.04 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.04”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andand this first test beneath the microdiorite sill provides encouraging evidence that the mineralized · goldGrade: 5Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- and this first test beneath the microdiorite sill provides encouraging evidence that the mineralized
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 5
- Grade Unit
- g/t
- Intercept
- 1.04 m
- From
- 102 m
- To
- 1 m
- Intercept Depth
- 102 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:102-1
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.2 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.00”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andand this first test beneath the microdiorite sill provides encouraging evidence that the mineralized · goldGrade: 21.67Grade Unit: g/tIntercept: 2.24 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- and this first test beneath the microdiorite sill provides encouraging evidence that the mineralized
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- IGO.V
Geometry
- Grade
- 21.67
- Grade Unit
- g/t
- Intercept
- 2.24 m
- From
- 110.23 m
- To
- 1.2 m
- Intercept Depth
- 110.23 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:110.23-1.2
- Mining Method
- underground
Location
- CRS
- NAD83, Zone 10 Datum
QA/QC
- Laboratory
- SGS Canada Inc.
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 21.67 g/t gold is exceptional against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 48.5 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 21.67 g/t gold is exceptional on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“21.67”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.