HRE: Subron On Track for High-Value HREO Resource Upgrade

Original announcement by asx on

Company
Heavy Rare Earths Limited
Ticker
HRE
Exchange
ASX
Region
Western Australia
Primary commodity
Rare earths
Secondary commodities
Gallium, Hafnium, Scandium, Thorium, Uranium
Document categories
Drill results, Resource update, Metallurgy
Extracted
2026-10-01 00:20:30 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Heavy Rare Earths Limited is on track to deliver a high-value, high-grade Heavy Rare Earth Oxide (HREO) resource upgrade for its Subron project by Q4 2026. This involves re-domaining the existing 159 Mt @ 870ppm TREO Inferred Resource to focus on smaller-tonnage but substantially higher-grade HREO domains, utilizing existing drill and assay data for a low-cost approach. Concurrently, metallurgical and mineralogical work is advancing to identify host minerals and processing routes, alongside re-assaying historical samples for critical minerals like gallium and hafnium to potentially add further value.

Reasoning: Heavy Rare Earths Limited is actively working towards a high-value, high-grade HREO resource upgrade for its Subron project by Q4 2026, leveraging existing data for a low-cost approach. This initiative is supported by ongoing metallurgical and mineralogical testwork, and re-assaying for additional critical minerals, which collectively enhance the project's potential, despite the current resource being historical and inferred, and the planned upgrade targeting a smaller tonnage.

Positive factors

  • resource_upgrade_planned
  • targeting_higher_grade_value
  • low_cost_approach
  • accelerating_metallurgical_program
  • identification_of_host_minerals
  • re_assaying_for_additional_critical_minerals
  • well_funded

Negative factors

  • resource_is_inferred
  • resource_is_historical
  • targeting_smaller_tonnage

Facts used in scoring: 99

Extracted facts

Stored fact records: 99. Some facts used in scoring do not have a stored record.

Drill Results (98)

AC1Subron Rare Earths · rare_earthsGrade: 1166Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC1
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1166
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
34 m
To
36 m
Intercept Depth
34 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC1:34-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1166”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1402Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1402
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1402”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1190Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1190
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1190”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1368Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1368
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1368”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1730Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1730
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1730”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1251Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1251
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1251”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC2Subron Rare Earths · rare_earthsGrade: 1193Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC2
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1193
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC2:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1193”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC4Subron Rare Earths · rare_earthsGrade: 1194Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC4
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1194
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC4:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1194”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC4Subron Rare Earths · rare_earthsGrade: 1087Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC4
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1087
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC4:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1087”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC4Subron Rare Earths · rare_earthsGrade: 1292Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC4
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1292
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
34 m
To
35 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC4:34-35

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1292”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC4Subron Rare Earths · rare_earthsGrade: 1066Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC4
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1066
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
35 m
To
36 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC4:35-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1066”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC5Subron Rare Earths · rare_earthsGrade: 1014Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC5
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1014
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
32 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC5:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1014”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC5Subron Rare Earths · rare_earthsGrade: 1582Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC5
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1582
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
34 m
To
36 m
Intercept Depth
32 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC5:34-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1582”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC6Subron Rare Earths · rare_earthsGrade: 1068Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC6
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1068
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC6:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1068”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC6Subron Rare Earths · rare_earthsGrade: 1175Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC6
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1175
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC6:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1175”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC6Subron Rare Earths · rare_earthsGrade: 1056Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC6
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1056
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC6:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1056”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC8Subron Rare Earths · rare_earthsGrade: 1414Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC8
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1414
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
24 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC8:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1414”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC8Subron Rare Earths · rare_earthsGrade: 2132Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC8
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2132
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
24 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC8:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2132”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC8Subron Rare Earths · rare_earthsGrade: 1107Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC8
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1107
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
28 m
To
29 m
Intercept Depth
24 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC8:28-29

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1107”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC9Subron Rare Earths · rare_earthsGrade: 1085Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC9
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1085
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
28 m
To
29 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC9:28-29

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1085”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC12Subron Rare Earths · rare_earthsGrade: 2313Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC12
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2313
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC12:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2313”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC12Subron Rare Earths · rare_earthsGrade: 1232Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC12
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1232
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC12:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1232”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC13Subron Rare Earths · rare_earthsGrade: 1038Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC13
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1038
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC13:20-21

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1038”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC16Subron Rare Earths · rare_earthsGrade: 1040Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC16
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1040
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC16:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1040”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC16Subron Rare Earths · rare_earthsGrade: 1533Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC16
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1533
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC16:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1533”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC16Subron Rare Earths · rare_earthsGrade: 1679Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC16
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1679
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC16:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1679”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC16Subron Rare Earths · rare_earthsGrade: 1089Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC16
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1089
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC16:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1089”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC17Subron Rare Earths · rare_earthsGrade: 1332Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC17
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1332
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC17:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1332”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC17Subron Rare Earths · rare_earthsGrade: 1042Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC17
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1042
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC17:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1042”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC17Subron Rare Earths · rare_earthsGrade: 1266Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC17
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1266
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC17:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1266”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC17Subron Rare Earths · rare_earthsGrade: 1188Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC17
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1188
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
34 m
To
36 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC17:34-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1188”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC18Subron Rare Earths · rare_earthsGrade: 1711Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC18
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1711
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC18:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1711”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC21Subron Rare Earths · rare_earthsGrade: 1292Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC21
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1292
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC21:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1292”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC21Subron Rare Earths · rare_earthsGrade: 1009Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC21
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1009
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC21:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1009”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC21Subron Rare Earths · rare_earthsGrade: 1561Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC21
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1561
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
26 m
To
27 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC21:26-27

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1561”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC21Subron Rare Earths · rare_earthsGrade: 1082Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC21
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1082
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
27 m
To
28 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC21:27-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1082”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC27Subron Rare Earths · rare_earthsGrade: 1043Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC27
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1043
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
30 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC27:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1043”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC27Subron Rare Earths · rare_earthsGrade: 1342Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC27
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1342
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
30 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC27:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1342”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1315Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1315
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
14 m
To
16 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:14-16

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1315”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1468Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1468
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1468”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1436Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1436
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1436”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 2807Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2807
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2807”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1884Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1884
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1884”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1045Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1045
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
34 m
To
36 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:34-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1045”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC28Subron Rare Earths · rare_earthsGrade: 1080Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC28
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1080
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
38 m
To
39 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC28:38-39

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1080”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 3677Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
3677
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“3677”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 1861Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1861
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1861”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 1614Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1614
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1614”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 2883Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2883
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2883”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 1426Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1426
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1426”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC29Subron Rare Earths · rare_earthsGrade: 2252Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC29
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2252
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC29:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2252”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC30Subron Rare Earths · rare_earthsGrade: 1241Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC30
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1241
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
30 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC30:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1241”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC33Subron Rare Earths · rare_earthsGrade: 1606Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC33
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1606
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC33:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1606”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC33Subron Rare Earths · rare_earthsGrade: 1431Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC33
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1431
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC33:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1431”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC35Subron Rare Earths · rare_earthsGrade: 2383Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC35
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2383
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC35:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2383”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC35Subron Rare Earths · rare_earthsGrade: 1181Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC35
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1181
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC35:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1181”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC35Subron Rare Earths · rare_earthsGrade: 1106Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC35
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1106
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC35:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1106”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC36Subron Rare Earths · rare_earthsGrade: 1040Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC36
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1040
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
28 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC36:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1040”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC37Subron Rare Earths · rare_earthsGrade: 1350Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC37
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1350
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC37:20-21

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1350”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC41Subron Rare Earths · rare_earthsGrade: 1308Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC41
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1308
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
14 m
To
16 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC41:14-16

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1308”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC41Subron Rare Earths · rare_earthsGrade: 1001Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC41
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1001
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC41:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1001”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC42Subron Rare Earths · rare_earthsGrade: 1038Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC42
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1038
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
12 m
To
14 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC42:12-14

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1038”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC58Subron Rare Earths · rare_earthsGrade: 1506Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC58
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1506
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC58:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1506”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC60Subron Rare Earths · rare_earthsGrade: 1092Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC60
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1092
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
26 m
To
27 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC60:26-27

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1092”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC70Subron Rare Earths · rare_earthsGrade: 1017Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC70
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1017
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC70:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1017”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC81Subron Rare Earths · rare_earthsGrade: 3095Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC81
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
3095
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
24 m
To
26 m
Intercept Depth
24 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC81:24-26

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“3095”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC81Subron Rare Earths · rare_earthsGrade: 2970Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC81
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2970
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
24 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC81:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2970”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC89Subron Rare Earths · rare_earthsGrade: 1299Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC89
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1299
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC89:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1299”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC89Subron Rare Earths · rare_earthsGrade: 2133Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC89
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2133
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC89:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2133”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC89Subron Rare Earths · rare_earthsGrade: 1316Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC89
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1316
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC89:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1316”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC89Subron Rare Earths · rare_earthsGrade: 1040Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC89
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1040
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
30 m
To
32 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC89:30-32

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1040”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC90Subron Rare Earths · rare_earthsGrade: 1332Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC90
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1332
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
32 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC90:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1332”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC90Subron Rare Earths · rare_earthsGrade: 1092Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC90
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1092
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
34 m
To
36 m
Intercept Depth
32 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC90:34-36

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1092”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC101Subron Rare Earths · rare_earthsGrade: 1194Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC101
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1194
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC101:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1194”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC101Subron Rare Earths · rare_earthsGrade: 1085Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC101
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1085
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
24 m
To
25 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC101:24-25

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1085”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC104Subron Rare Earths · rare_earthsGrade: 1133Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC104
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1133
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC104:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1133”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC104Subron Rare Earths · rare_earthsGrade: 1143Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC104
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1143
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
28 m
To
30 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC104:28-30

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1143”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC110Subron Rare Earths · rare_earthsGrade: 1727Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC110
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1727
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC110:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1727”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC110Subron Rare Earths · rare_earthsGrade: 1287Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC110
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1287
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
28 m
To
29 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC110:28-29

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1287”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC111Subron Rare Earths · rare_earthsGrade: 1068Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC111
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1068
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
22 m
To
24 m
Intercept Depth
22 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC111:22-24

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1068”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC112Subron Rare Earths · rare_earthsGrade: 1482Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC112
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1482
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
21 m
To
23 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC112:21-23

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1482”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC115Subron Rare Earths · rare_earthsGrade: 1922Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC115
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1922
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
26 m
To
28 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC115:26-28

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1922”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC115Subron Rare Earths · rare_earthsGrade: 1639Grade Unit: ppmIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC115
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1639
Grade Unit
ppm
Intercept
1 m
True Width
1 m
From
28 m
To
29 m
Intercept Depth
26 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC115:28-29

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1639”

Context: 1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC119Subron Rare Earths · rare_earthsGrade: 1148Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC119
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1148
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC119:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1148”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC122Subron Rare Earths · rare_earthsGrade: 2255Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC122
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2255
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC122:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2255”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC123Subron Rare Earths · rare_earthsGrade: 1230Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC123
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1230
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
15 m
To
17 m
Intercept Depth
15 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC123:15-17

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1230”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC129Subron Rare Earths · rare_earthsGrade: 1930Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC129
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1930
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
21 m
To
23 m
Intercept Depth
21 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC129:21-23

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1930”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC130Subron Rare Earths · rare_earthsGrade: 1212Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC130
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1212
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
20 m
To
22 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC130:20-22

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1212”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC130Subron Rare Earths · rare_earthsGrade: 1013Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC130
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1013
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
32 m
To
34 m
Intercept Depth
20 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC130:32-34

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1013”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC131Subron Rare Earths · rare_earthsGrade: 1000Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC131
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1000
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
23 m
To
25 m
Intercept Depth
23 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC131:23-25

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1000”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC134Subron Rare Earths · rare_earthsGrade: 1602Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC134
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1602
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
14 m
To
16 m
Intercept Depth
14 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC134:14-16

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1602”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC136Subron Rare Earths · rare_earthsGrade: 1457Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC136
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1457
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
18 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC136:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1457”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC137Subron Rare Earths · rare_earthsGrade: 1024Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC137
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1024
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
17 m
To
19 m
Intercept Depth
17 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC137:17-19

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1024”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC137Subron Rare Earths · rare_earthsGrade: 1132Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC137
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1132
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
25 m
To
27 m
Intercept Depth
17 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC137:25-27

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1132”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC142Subron Rare Earths · rare_earthsGrade: 1526Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC142
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1526
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC142:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1526”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC175Subron Rare Earths · rare_earthsGrade: 1286Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC175
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1286
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
12 m
To
14 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC175:12-14

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“1286”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC179Subron Rare Earths · rare_earthsGrade: 2176Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC179
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
2176
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
16 m
To
18 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC179:16-18

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This historical intercept shows a moderate TREO grade over a narrow width, contributing to the overall resource. The true width is disclosed, and QA/QC procedures are mentioned, but the data is historical and part of an inferred resource.

Positive factors

  • true_width_disclosed
  • qa_qc_disclosed

Negative factors

  • stale_data_re_release
  • inferred_resource
  • no_metal_equivalent_assumptions

Evidence · table

“2176”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

AC179Subron Rare Earths · rare_earthsGrade: 1177Grade Unit: ppmIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
AC179
Project
Subron Rare Earths
Commodity
rare_earths
Region
australia_wa
Reported Region
australia_wa
Ticker
HRE

Geometry

Grade
1177
Grade Unit
ppm
Intercept
2 m
True Width
2 m
From
18 m
To
20 m
Intercept Depth
16 m

Classification

Program
exploration
Sample Type
drill
Group ID
AC179:18-20

QA/QC

Laboratory
LabWest Minerals Analysis
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
thorium, uranium

Metal Equivalent

Assumptions Disclosed
No

Compositing

Cutoff Grade
1000
Cutoff Unit
ppm
Dilution Disclosed
Yes

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2022-12-31T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Positive factors

  • true_width_disclosed

Evidence · table

“1177”

Context: 2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Resource Estimates (1)

inferredSubron Rare Earths Project · rare_earthsTonnes: 159000000Grade: 870Grade Unit: ppmHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Project
Subron Rare Earths Project
Commodity
rare_earths
Region
australia_wa
Reported Region
Western Australia
Ticker
HRE

Resource scope

Estimate type
resource
Reporting standards
jorc
QP Signed
Yes
Qualified person names
Mr Claudio Sheriff
Resource group id
resource:93b20cada735887f0dcf

Resource Data

Category
inferred
Tonnes
159000000
Grade
870
Grade Unit
ppm

Prior Estimate

Resource Date
2023-10-03

Review

Needs Review
Yes
Review Reason
historical_restatement
Historical
Yes
Historical Source Date
2023-10-03T00:00:00.000Z

Dates

Event date
2026-09-30T00:00:00.000Z

Reasoning: This is a historical inferred resource estimate that the company is planning to upgrade, indicating its current status as a baseline for future work.

Negative factors

  • resource_is_inferred
  • resource_is_historical

Evidence · text

“existing 159Mt @ 870ppm TREO JORC Inferred Resource1”

Tags used in scoring

Inferred Resourcenegative

Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: category is "inferred"

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

QP/CP Signedpositive

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: qp_signed is true

JORC Compliantpositive

Resource estimate prepared in compliance with JORC Code (Australia) — high reporting standard.

Why it applies: reporting_standards includes jorc

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

Resource Updateneutral

Revised estimate for an existing resource — compare to prior to assess progress.

Why it applies: the release compares against a previous estimate

Stale Estimatenegative

Effective date is >2 years old — data currency concern, may not reflect current geological understanding.

Why it applies: effective date is 3.0 years before this release

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.