Grid Metals Announces Positive Mineralogical Results at Falcon West, Engages SGS Canada for Ore Sorting Test Work, and Announces Investor Relations Agreements
Original announcement by orestocks on
- Company
- Grid Metals Corp.
- Ticker
- GRDM.V
- Exchange
- Unavailable
- Region
- Manitoba
- Primary commodity
- Cesium
- Secondary commodities
- Lithium, Rubidium, Tantalum
- Document categories
- Drill results, Metallurgy, Other
- Extracted
- 2026-09-08 20:51:07 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Grid Metals announced positive mineralogical results from its Lucy South pegmatite at the Falcon West Property, confirming pollucite as the dominant cesium-bearing mineral. The company has engaged SGS Canada for initial ore sorting test work using X-Ray Transmission (XRT) to produce a marketable pollucite concentrate. Additionally, the release included high-grade cesium and lithium drill intercepts from the property and details of investor relations agreements.
Reasoning: Grid Metals announced positive mineralogical results confirming pollucite as the primary cesium host at its Falcon West property, which is a key step towards developing a cesium operation. The company is proceeding with initial ore sorting test work, a positive de-risking step, and reported high-grade cesium and lithium drill intercepts.
Positive factors
- Pollucite confirmed as dominant cesium host mineral at Lucy South
- Strong correlation between Cs2O grade and pollucite content
- Engagement of SGS Canada for initial ore sorting test work using XRT
- XRT is a well-proven approach for pollucite recovery
- High cesium and lithium grades reported in drill intercepts
Negative factors
- Ore sorting test work is initial, not pilot scale yet
- Target concentrate grade (10-20% Cs2O) is a goal, not a result
- True width of drill intercepts is estimated, not explicitly stated
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 106

Classification and evidence
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: the document describes a mill_cil route ("CIL")
Gravity Routeneutral
Gravity separation forms a material part of the flowsheet.
Why it applies: the document describes a gravity route ("Falcon")
Multi-Domain Testedpositive
Variability across ore domains (oxide, transition, fresh) has been addressed.
Why it applies: 2 distinct composites were tested
Extracted facts
Stored fact records: 106. Some facts used in scoring do not have a stored record.
Drill Results (78)
LU-12-1Falcon West · cesiumGrade: 7.59Grade Unit: %Intercept: 0.79 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-1
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 7.59
- Grade Unit
- %
- Intercept
- 0.79 m
- From
- 18.56 m
- To
- 19.35 m
- Hole Depth
- 173.5 m
- Intercept Depth
- 18.56 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-1:18.56-19.35
- Mining Method
- open_pit
Location
- Easting
- 321629
- Northing
- 5502623
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“7.59”
Context: 0.79
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-1Falcon West · lithiumGrade: 0.23Grade Unit: %Intercept: 0.79 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-1
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 0.79 m
- From
- 18.56 m
- To
- 19.35 m
- Hole Depth
- 173.5 m
- Intercept Depth
- 18.56 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-1:18.56-19.35
- Mining Method
- open_pit
Location
- Easting
- 321629
- Northing
- 5502623
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.23”
Context: 0.79
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-1Falcon West · rubidiumGrade: 0.37Grade Unit: %Intercept: 0.79 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-1
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 0.79 m
- From
- 18.56 m
- To
- 19.35 m
- Hole Depth
- 173.5 m
- Intercept Depth
- 18.56 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-1:18.56-19.35
- Mining Method
- open_pit
Location
- Easting
- 321629
- Northing
- 5502623
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.37”
Context: 0.79
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-1Falcon West · tantalumGrade: 1Grade Unit: ppmIntercept: 0.79 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-1
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 0.79 m
- From
- 18.56 m
- To
- 19.35 m
- Hole Depth
- 173.5 m
- Intercept Depth
- 18.56 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-1:18.56-19.35
- Mining Method
- open_pit
Location
- Easting
- 321629
- Northing
- 5502623
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1”
Context: 0.79
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-2Falcon West · cesiumGrade: 17.18Grade Unit: %Intercept: 1.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-2
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 17.18
- Grade Unit
- %
- Intercept
- 1.09 m
- From
- 26.8 m
- To
- 27.89 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 26.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-2:26.8-27.89
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502639
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 330.9 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“17.18”
Context: 1.09
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-2Falcon West · lithiumGrade: 0.28Grade Unit: %Intercept: 1.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-2
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 1.09 m
- From
- 26.8 m
- To
- 27.89 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 26.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-2:26.8-27.89
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502639
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 330.9 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.28”
Context: 1.09
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-2Falcon West · rubidiumGrade: 0.57Grade Unit: %Intercept: 1.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-2
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.57
- Grade Unit
- %
- Intercept
- 1.09 m
- From
- 26.8 m
- To
- 27.89 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 26.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-2:26.8-27.89
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502639
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 330.9 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.57”
Context: 1.09
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-2Falcon West · tantalumGrade: 4Grade Unit: ppmIntercept: 1.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-2
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 1.09 m
- From
- 26.8 m
- To
- 27.89 m
- Hole Depth
- 50.5 m
- Intercept Depth
- 26.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-2:26.8-27.89
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502639
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 330.9 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“4”
Context: 1.09
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-3Falcon West · cesiumGrade: 2Grade Unit: %Intercept: 0.96 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-3
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2
- Grade Unit
- %
- Intercept
- 0.96 m
- From
- 17.14 m
- To
- 18.1 m
- Hole Depth
- 46.5 m
- Intercept Depth
- 17.14 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-3:17.14-18.1
- Mining Method
- open_pit
Location
- Easting
- 321677
- Northing
- 5502689
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331.4 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a high cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- High Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“2.00”
Context: 0.96
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-3Falcon West · lithiumGrade: 3.06Grade Unit: %Intercept: 0.96 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-3
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 3.06
- Grade Unit
- %
- Intercept
- 0.96 m
- From
- 17.14 m
- To
- 18.1 m
- Hole Depth
- 46.5 m
- Intercept Depth
- 17.14 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-3:17.14-18.1
- Mining Method
- open_pit
Location
- Easting
- 321677
- Northing
- 5502689
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331.4 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high lithium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“3.06”
Context: 0.96
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-3Falcon West · rubidiumGrade: 0.11Grade Unit: %Intercept: 0.96 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-3
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.96 m
- From
- 17.14 m
- To
- 18.1 m
- Hole Depth
- 46.5 m
- Intercept Depth
- 17.14 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-3:17.14-18.1
- Mining Method
- open_pit
Location
- Easting
- 321677
- Northing
- 5502689
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331.4 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low rubidium grade, which is not significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Very low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.11”
Context: 0.96
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU-12-3Falcon West · tantalumGrade: 11800Grade Unit: ppmIntercept: 0.96 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- LU-12-3
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 11800
- Grade Unit
- ppm
- Intercept
- 0.96 m
- From
- 17.14 m
- To
- 18.1 m
- Hole Depth
- 46.5 m
- Intercept Depth
- 17.14 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU-12-3:17.14-18.1
- Mining Method
- open_pit
Location
- Easting
- 321677
- Northing
- 5502689
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 331.4 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2012-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high tantalum grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Ta2O5 grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“11800”
Context: 0.96
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-01Falcon West · cesiumGrade: 1.02Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-01
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 60.9 m
- To
- 61.35 m
- Hole Depth
- 102 m
- Intercept Depth
- 60.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-01:60.9-61.35
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 154.1 °
- Dip
- -43.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1.02”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-01Falcon West · lithiumGrade: 0.95Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-01
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.95
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 60.9 m
- To
- 61.35 m
- Hole Depth
- 102 m
- Intercept Depth
- 60.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-01:60.9-61.35
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 154.1 °
- Dip
- -43.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low lithium grade, which is less significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.95”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-01Falcon West · rubidiumGrade: 1.02Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-01
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 60.9 m
- To
- 61.35 m
- Hole Depth
- 102 m
- Intercept Depth
- 60.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-01:60.9-61.35
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 154.1 °
- Dip
- -43.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1.02”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-01Falcon West · tantalumGrade: 1Grade Unit: ppmIntercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-01
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 0.45 m
- From
- 60.9 m
- To
- 61.35 m
- Hole Depth
- 102 m
- Intercept Depth
- 60.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-01:60.9-61.35
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 154.1 °
- Dip
- -43.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-02Falcon West · cesiumGrade: 8.31Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-02
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 8.31
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 30.75 m
- To
- 30.95 m
- Hole Depth
- 102 m
- Intercept Depth
- 30.75 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-02:30.75-30.95
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 155.9 °
- Dip
- -65.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“8.31”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-02Falcon West · lithiumGrade: 2Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-02
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 30.75 m
- To
- 30.95 m
- Hole Depth
- 102 m
- Intercept Depth
- 30.75 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-02:30.75-30.95
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 155.9 °
- Dip
- -65.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high lithium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“2.00”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-02Falcon West · rubidiumGrade: 0.26Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-02
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 30.75 m
- To
- 30.95 m
- Hole Depth
- 102 m
- Intercept Depth
- 30.75 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-02:30.75-30.95
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 155.9 °
- Dip
- -65.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.26”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-02Falcon West · tantalumGrade: 33Grade Unit: ppmIntercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-02
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 33
- Grade Unit
- ppm
- Intercept
- 0.2 m
- From
- 30.75 m
- To
- 30.95 m
- Hole Depth
- 102 m
- Intercept Depth
- 30.75 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-02:30.75-30.95
- Mining Method
- open_pit
Location
- Easting
- 321690
- Northing
- 5502797
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328.4 m
- Azimuth
- 155.9 °
- Dip
- -65.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“33”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-09Falcon West · cesiumGrade: 11.66Grade Unit: %Intercept: 0.65 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-09
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 11.66
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 22.4 m
- To
- 23.05 m
- Hole Depth
- 51 m
- Intercept Depth
- 22.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-09:22.4-23.05
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502666
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 326 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“11.66”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-09Falcon West · lithiumGrade: 3.27Grade Unit: %Intercept: 0.65 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-09
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 3.27
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 22.4 m
- To
- 23.05 m
- Hole Depth
- 51 m
- Intercept Depth
- 22.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-09:22.4-23.05
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502666
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 326 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high lithium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“3.27”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-09Falcon West · rubidiumGrade: 0.35Grade Unit: %Intercept: 0.65 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-09
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 22.4 m
- To
- 23.05 m
- Hole Depth
- 51 m
- Intercept Depth
- 22.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-09:22.4-23.05
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502666
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 326 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.35”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-09Falcon West · tantalumGrade: 363Grade Unit: ppmIntercept: 0.65 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-09
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 363
- Grade Unit
- ppm
- Intercept
- 0.65 m
- From
- 22.4 m
- To
- 23.05 m
- Hole Depth
- 51 m
- Intercept Depth
- 22.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-09:22.4-23.05
- Mining Method
- open_pit
Location
- Easting
- 321668
- Northing
- 5502666
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 326 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good tantalum grade, which is significant, though the true width is estimated.
Positive factors
- Good Ta2O5 grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“363”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-21Falcon West · cesiumGrade: 1.02Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 37.8 m
- To
- 38 m
- Hole Depth
- 75 m
- Intercept Depth
- 37.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-21:37.8-38
- Mining Method
- open_pit
Location
- Easting
- 320806
- Northing
- 5502319
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 238.9 °
- Dip
- -88.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.02”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-21Falcon West · lithiumGrade: 0.69Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.69
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 37.8 m
- To
- 38 m
- Hole Depth
- 75 m
- Intercept Depth
- 37.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-21:37.8-38
- Mining Method
- open_pit
Location
- Easting
- 320806
- Northing
- 5502319
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 238.9 °
- Dip
- -88.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low lithium grade, which is less significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Low Li2O grade for pegmatite
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.69”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-21Falcon West · rubidiumGrade: 1.41Grade Unit: %Intercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.41
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 37.8 m
- To
- 38 m
- Hole Depth
- 75 m
- Intercept Depth
- 37.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-21:37.8-38
- Mining Method
- open_pit
Location
- Easting
- 320806
- Northing
- 5502319
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 238.9 °
- Dip
- -88.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.41”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
ADL24-21Falcon West · tantalumGrade: 36Grade Unit: ppmIntercept: 0.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- ADL24-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 36
- Grade Unit
- ppm
- Intercept
- 0.2 m
- From
- 37.8 m
- To
- 38 m
- Hole Depth
- 75 m
- Intercept Depth
- 37.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- ADL24-21:37.8-38
- Mining Method
- open_pit
Location
- Easting
- 320806
- Northing
- 5502319
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 238.9 °
- Dip
- -88.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“36”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-01Falcon West · cesiumGrade: 27.35Grade Unit: %Intercept: 0.42 mView all detailsHide details
Identity
- Hole ID
- LU25-01
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 27.35
- Grade Unit
- %
- Intercept
- 0.42 m
- From
- 27.1 m
- To
- 27.52 m
- Hole Depth
- 42 m
- Intercept Depth
- 27.1 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-01:27.1-27.52
- Mining Method
- open_pit
Location
- Easting
- 321671
- Northing
- 5502642
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 329.2 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“27.35”
Context: 0.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-01Falcon West · lithiumGrade: 0.59Grade Unit: %Intercept: 0.42 mView all detailsHide details
Identity
- Hole ID
- LU25-01
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 0.42 m
- From
- 27.1 m
- To
- 27.52 m
- Hole Depth
- 42 m
- Intercept Depth
- 27.1 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-01:27.1-27.52
- Mining Method
- open_pit
Location
- Easting
- 321671
- Northing
- 5502642
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 329.2 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.59”
Context: 0.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-01Falcon West · rubidiumGrade: 0.6Grade Unit: %Intercept: 0.42 mView all detailsHide details
Identity
- Hole ID
- LU25-01
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 0.42 m
- From
- 27.1 m
- To
- 27.52 m
- Hole Depth
- 42 m
- Intercept Depth
- 27.1 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-01:27.1-27.52
- Mining Method
- open_pit
Location
- Easting
- 321671
- Northing
- 5502642
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 329.2 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.60”
Context: 0.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-01Falcon West · tantalumGrade: 3Grade Unit: ppmIntercept: 0.42 mView all detailsHide details
Identity
- Hole ID
- LU25-01
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 0.42 m
- From
- 27.1 m
- To
- 27.52 m
- Hole Depth
- 42 m
- Intercept Depth
- 27.1 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-01:27.1-27.52
- Mining Method
- open_pit
Location
- Easting
- 321671
- Northing
- 5502642
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 329.2 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“3”
Context: 0.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-08Falcon West · cesiumGrade: 27.14Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LU25-08
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 27.14
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 21.76 m
- To
- 22.41 m
- Hole Depth
- 36 m
- Intercept Depth
- 21.76 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-08:21.76-22.41
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 215 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“27.14”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-08Falcon West · lithiumGrade: 0.29Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LU25-08
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 21.76 m
- To
- 22.41 m
- Hole Depth
- 36 m
- Intercept Depth
- 21.76 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-08:21.76-22.41
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 215 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.29”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-08Falcon West · rubidiumGrade: 0.78Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LU25-08
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.78
- Grade Unit
- %
- Intercept
- 0.65 m
- From
- 21.76 m
- To
- 22.41 m
- Hole Depth
- 36 m
- Intercept Depth
- 21.76 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-08:21.76-22.41
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 215 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.78”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-08Falcon West · tantalumGrade: 2Grade Unit: ppmIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LU25-08
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 0.65 m
- From
- 21.76 m
- To
- 22.41 m
- Hole Depth
- 36 m
- Intercept Depth
- 21.76 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-08:21.76-22.41
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 215 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“2”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-09Falcon West · cesiumGrade: 24.07Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-09
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 24.07
- Grade Unit
- %
- Intercept
- 0.92 m
- From
- 17.08 m
- To
- 18 m
- Hole Depth
- 39 m
- Intercept Depth
- 17.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-09:17.08-18
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 285.2 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“24.07”
Context: 0.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-09Falcon West · lithiumGrade: 1.02Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-09
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.02
- Grade Unit
- %
- Intercept
- 0.92 m
- From
- 17.08 m
- To
- 18 m
- Hole Depth
- 39 m
- Intercept Depth
- 17.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-09:17.08-18
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 285.2 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good lithium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1.02”
Context: 0.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-09Falcon West · rubidiumGrade: 0.94Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-09
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.94
- Grade Unit
- %
- Intercept
- 0.92 m
- From
- 17.08 m
- To
- 18 m
- Hole Depth
- 39 m
- Intercept Depth
- 17.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-09:17.08-18
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 285.2 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.94”
Context: 0.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-09Falcon West · tantalumGrade: 7Grade Unit: ppmIntercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-09
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 7
- Grade Unit
- ppm
- Intercept
- 0.92 m
- From
- 17.08 m
- To
- 18 m
- Hole Depth
- 39 m
- Intercept Depth
- 17.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-09:17.08-18
- Mining Method
- open_pit
Location
- Easting
- 321676
- Northing
- 5502680
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327.4 m
- Azimuth
- 285.2 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“7”
Context: 0.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · cesiumGrade: 1.58Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.58
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 62.85 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 62.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:62.85-62.95
- Mining Method
- open_pit
Location
- Easting
- 321648
- Northing
- 5502583
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.58”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · lithiumGrade: 3.77Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 3.77
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 62.85 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 62.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:62.85-62.95
- Mining Method
- open_pit
Location
- Easting
- 321648
- Northing
- 5502583
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high lithium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“3.77”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · rubidiumGrade: 0.12Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 62.85 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 62.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:62.85-62.95
- Mining Method
- open_pit
Location
- Easting
- 321648
- Northing
- 5502583
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low rubidium grade, which is not significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Very low Rb2O grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.12”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · tantalumGrade: 82Grade Unit: ppmIntercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 82
- Grade Unit
- ppm
- Intercept
- 0.1 m
- From
- 62.85 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 62.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:62.85-62.95
- Mining Method
- open_pit
Location
- Easting
- 321648
- Northing
- 5502583
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“82”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · cesiumGrade: 20.25Grade Unit: %Intercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 20.25
- Grade Unit
- %
- Intercept
- 0.25 m
- From
- 25.5 m
- To
- 25.75 m
- Hole Depth
- 36 m
- Intercept Depth
- 25.5 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:25.5-25.75
- Mining Method
- open_pit
Location
- Easting
- 321630
- Northing
- 5502621
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 335.5 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“20.25”
Context: 0.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · lithiumGrade: 1Grade Unit: %Intercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 0.25 m
- From
- 25.5 m
- To
- 25.75 m
- Hole Depth
- 36 m
- Intercept Depth
- 25.5 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:25.5-25.75
- Mining Method
- open_pit
Location
- Easting
- 321630
- Northing
- 5502621
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 335.5 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good lithium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.00”
Context: 0.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · rubidiumGrade: 0.39Grade Unit: %Intercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 0.25 m
- From
- 25.5 m
- To
- 25.75 m
- Hole Depth
- 36 m
- Intercept Depth
- 25.5 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:25.5-25.75
- Mining Method
- open_pit
Location
- Easting
- 321630
- Northing
- 5502621
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 335.5 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.39”
Context: 0.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · tantalumGrade: 72Grade Unit: ppmIntercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 72
- Grade Unit
- ppm
- Intercept
- 0.25 m
- From
- 25.5 m
- To
- 25.75 m
- Hole Depth
- 36 m
- Intercept Depth
- 25.5 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:25.5-25.75
- Mining Method
- open_pit
Location
- Easting
- 321630
- Northing
- 5502621
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 335.5 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“72”
Context: 0.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · cesiumGrade: 0.22Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.22
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 25.83 m
- To
- 26.2 m
- Hole Depth
- 51 m
- Intercept Depth
- 25.83 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:25.83-26.2
- Mining Method
- open_pit
Location
- Easting
- 321628
- Northing
- 5502601
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.6 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows trace cesium grade, which is not significant, and the true width is estimated.
Positive factors
- Cs2O present
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
- Trace Cs2O grade
Evidence · table
“0.22”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · lithiumGrade: 0.36Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 25.83 m
- To
- 26.2 m
- Hole Depth
- 51 m
- Intercept Depth
- 25.83 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:25.83-26.2
- Mining Method
- open_pit
Location
- Easting
- 321628
- Northing
- 5502601
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.6 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.36”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · rubidiumGrade: 0.14Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 25.83 m
- To
- 26.2 m
- Hole Depth
- 51 m
- Intercept Depth
- 25.83 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:25.83-26.2
- Mining Method
- open_pit
Location
- Easting
- 321628
- Northing
- 5502601
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.6 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low rubidium grade, which is not significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Very low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.14”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · tantalumGrade: 1Grade Unit: ppmIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 0.37 m
- From
- 25.83 m
- To
- 26.2 m
- Hole Depth
- 51 m
- Intercept Depth
- 25.83 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:25.83-26.2
- Mining Method
- open_pit
Location
- Easting
- 321628
- Northing
- 5502601
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.6 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 30.43Grade Unit: %Intercept: 0.53 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 30.43
- Grade Unit
- %
- Intercept
- 0.53 m
- From
- 19.08 m
- To
- 19.61 m
- Hole Depth
- 33 m
- Intercept Depth
- 19.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-19.61
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“30.43”
Context: 0.53
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 0.34Grade Unit: %Intercept: 0.53 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.34
- Grade Unit
- %
- Intercept
- 0.53 m
- From
- 19.08 m
- To
- 19.61 m
- Hole Depth
- 33 m
- Intercept Depth
- 19.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-19.61
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.34”
Context: 0.53
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.82Grade Unit: %Intercept: 0.53 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.82
- Grade Unit
- %
- Intercept
- 0.53 m
- From
- 19.08 m
- To
- 19.61 m
- Hole Depth
- 33 m
- Intercept Depth
- 19.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-19.61
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low rubidium grade, which is less significant, and the true width is estimated.
Positive factors
- Rubidium present
Negative factors
- Low Rb2O grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.82”
Context: 0.53
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 2Grade Unit: ppmIntercept: 0.53 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2
- Grade Unit
- ppm
- Intercept
- 0.53 m
- From
- 19.08 m
- To
- 19.61 m
- Hole Depth
- 33 m
- Intercept Depth
- 19.08 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-19.61
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“2”
Context: 0.53
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-29Falcon West · cesiumGrade: 1.45Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-29
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.45
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 61.4 m
- To
- 61.5 m
- Hole Depth
- 63 m
- Intercept Depth
- 61.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-29:61.4-61.5
- Mining Method
- open_pit
Location
- Easting
- 321645
- Northing
- 5502610
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.4 m
- Azimuth
- 58.2 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.45”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-29Falcon West · lithiumGrade: 0.96Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-29
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 61.4 m
- To
- 61.5 m
- Hole Depth
- 63 m
- Intercept Depth
- 61.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-29:61.4-61.5
- Mining Method
- open_pit
Location
- Easting
- 321645
- Northing
- 5502610
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.4 m
- Azimuth
- 58.2 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low lithium grade, which is less significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Low Li2O grade for pegmatite
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.96”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-29Falcon West · rubidiumGrade: 1.2Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-29
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.2
- Grade Unit
- %
- Intercept
- 0.1 m
- From
- 61.4 m
- To
- 61.5 m
- Hole Depth
- 63 m
- Intercept Depth
- 61.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-29:61.4-61.5
- Mining Method
- open_pit
Location
- Easting
- 321645
- Northing
- 5502610
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.4 m
- Azimuth
- 58.2 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.20”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-29Falcon West · tantalumGrade: 19Grade Unit: ppmIntercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- LU25-29
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 19
- Grade Unit
- ppm
- Intercept
- 0.1 m
- From
- 61.4 m
- To
- 61.5 m
- Hole Depth
- 63 m
- Intercept Depth
- 61.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-29:61.4-61.5
- Mining Method
- open_pit
Location
- Easting
- 321645
- Northing
- 5502610
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334.4 m
- Azimuth
- 58.2 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“19”
Context: 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-51Falcon West · cesiumGrade: 30Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-51
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 30
- Grade Unit
- %
- Intercept
- 0.95 m
- From
- 24.05 m
- To
- 25 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-51:24.05-25
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 233 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows an exceptionally high cesium grade, which is highly significant for the project, though the true width is estimated.
Positive factors
- Exceptional Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“30.00”
Context: 0.95
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-51Falcon West · lithiumGrade: 0.48Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-51
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.48
- Grade Unit
- %
- Intercept
- 0.95 m
- From
- 24.05 m
- To
- 25 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-51:24.05-25
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 233 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.48”
Context: 0.95
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-51Falcon West · rubidiumGrade: 0.96Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-51
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 0.95 m
- From
- 24.05 m
- To
- 25 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-51:24.05-25
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 233 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.96”
Context: 0.95
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-51Falcon West · tantalumGrade: 3Grade Unit: ppmIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-51
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 3
- Grade Unit
- ppm
- Intercept
- 0.95 m
- From
- 24.05 m
- To
- 25 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-51:24.05-25
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 233 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“3”
Context: 0.95
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-52Falcon West · cesiumGrade: 1.81Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LU25-52
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.81
- Grade Unit
- %
- Intercept
- 0.8 m
- From
- 23.2 m
- To
- 24 m
- Hole Depth
- 42 m
- Intercept Depth
- 23.2 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-52:23.2-24
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 255.6 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1.81”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-52Falcon West · lithiumGrade: 0.08Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LU25-52
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 0.8 m
- From
- 23.2 m
- To
- 24 m
- Hole Depth
- 42 m
- Intercept Depth
- 23.2 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-52:23.2-24
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 255.6 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low lithium grade, which is not significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Very low Li2O grade for pegmatite
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.08”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-52Falcon West · rubidiumGrade: 2.16Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LU25-52
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2.16
- Grade Unit
- %
- Intercept
- 0.8 m
- From
- 23.2 m
- To
- 24 m
- Hole Depth
- 42 m
- Intercept Depth
- 23.2 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-52:23.2-24
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 255.6 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very high rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Very high Rb2O grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“2.16”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-52Falcon West · tantalumGrade: 102Grade Unit: ppmIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LU25-52
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 102
- Grade Unit
- ppm
- Intercept
- 0.8 m
- From
- 23.2 m
- To
- 24 m
- Hole Depth
- 42 m
- Intercept Depth
- 23.2 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-52:23.2-24
- Mining Method
- open_pit
Location
- Easting
- 321684
- Northing
- 5502677
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 328 m
- Azimuth
- 255.6 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good tantalum grade, which is significant, though the true width is estimated.
Positive factors
- Good Ta2O5 grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“102”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-65Falcon West · cesiumGrade: 2.35Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- LU25-65
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2.35
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 21.65 m
- To
- 21.85 m
- Hole Depth
- 42 m
- Intercept Depth
- 21.65 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-65:21.65-21.85
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 180 °
- Dip
- -78 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a high cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- High Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“2.35”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-65Falcon West · lithiumGrade: 0.73Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- LU25-65
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.73
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 21.65 m
- To
- 21.85 m
- Hole Depth
- 42 m
- Intercept Depth
- 21.65 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-65:21.65-21.85
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 180 °
- Dip
- -78 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a low lithium grade, which is less significant compared to the cesium, and the true width is estimated.
Positive factors
- Lithium present
Negative factors
- Low Li2O grade for pegmatite
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“0.73”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-65Falcon West · rubidiumGrade: 1.64Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- LU25-65
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.64
- Grade Unit
- %
- Intercept
- 0.2 m
- From
- 21.65 m
- To
- 21.85 m
- Hole Depth
- 42 m
- Intercept Depth
- 21.65 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-65:21.65-21.85
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 180 °
- Dip
- -78 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1.64”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-65Falcon West · tantalumGrade: 1Grade Unit: ppmIntercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- LU25-65
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1
- Grade Unit
- ppm
- Intercept
- 0.2 m
- From
- 21.65 m
- To
- 21.85 m
- Hole Depth
- 42 m
- Intercept Depth
- 21.65 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-65:21.65-21.85
- Mining Method
- open_pit
Location
- Easting
- 321633
- Northing
- 5502629
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 334 m
- Azimuth
- 180 °
- Dip
- -78 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a very low tantalum grade, which is not significant, and the true width is estimated.
Positive factors
- Tantalum present
Negative factors
- Very low Ta2O5 grade
- True width estimated, not stated
- Very narrow intercept length
Evidence · table
“1”
Context: 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-01Falcon West · cesiumGrade: 0.7Grade Unit: %Intercept: 0.66 mView all detailsHide details
Identity
- Hole ID
- LU26-01
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 0.66 m
- From
- 17.34 m
- To
- 18 m
- Hole Depth
- 30 m
- Intercept Depth
- 17.34 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-01:17.34-18
- Mining Method
- open_pit
Location
- Easting
- 321683
- Northing
- 5502697
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 317.1 °
- Dip
- -64.2 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.70”
Context: 0.66
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-01Falcon West · lithiumGrade: 1.45Grade Unit: %Intercept: 0.66 mView all detailsHide details
Identity
- Hole ID
- LU26-01
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 1.45
- Grade Unit
- %
- Intercept
- 0.66 m
- From
- 17.34 m
- To
- 18 m
- Hole Depth
- 30 m
- Intercept Depth
- 17.34 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-01:17.34-18
- Mining Method
- open_pit
Location
- Easting
- 321683
- Northing
- 5502697
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 317.1 °
- Dip
- -64.2 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a strong lithium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Strong Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“1.45”
Context: 0.66
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-01Falcon West · rubidiumGrade: 0.88Grade Unit: %Intercept: 0.66 mView all detailsHide details
Identity
- Hole ID
- LU26-01
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.88
- Grade Unit
- %
- Intercept
- 0.66 m
- From
- 17.34 m
- To
- 18 m
- Hole Depth
- 30 m
- Intercept Depth
- 17.34 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-01:17.34-18
- Mining Method
- open_pit
Location
- Easting
- 321683
- Northing
- 5502697
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 317.1 °
- Dip
- -64.2 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good rubidium grade, which is significant, though the true width is estimated.
Positive factors
- Good Rb2O grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.88”
Context: 0.66
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-01Falcon West · tantalumGrade: 174Grade Unit: ppmIntercept: 0.66 mView all detailsHide details
Identity
- Hole ID
- LU26-01
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 174
- Grade Unit
- ppm
- Intercept
- 0.66 m
- From
- 17.34 m
- To
- 18 m
- Hole Depth
- 30 m
- Intercept Depth
- 17.34 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-01:17.34-18
- Mining Method
- open_pit
Location
- Easting
- 321683
- Northing
- 5502697
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 317.1 °
- Dip
- -64.2 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good tantalum grade, which is significant, though the true width is estimated.
Positive factors
- Good Ta2O5 grade
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“174”
Context: 0.66
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-02Falcon West · cesiumGrade: 0.64Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- LU26-02
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 0.64
- Grade Unit
- %
- Intercept
- 0.82 m
- From
- 25 m
- To
- 25.82 m
- Hole Depth
- 33 m
- Intercept Depth
- 25 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-02:25-25.82
- Mining Method
- open_pit
Location
- Easting
- 321694
- Northing
- 5502692
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 316.5 °
- Dip
- -64.8 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: This drill intercept shows a good cesium grade, which is significant for the project, though the true width is estimated.
Positive factors
- Good Cs2O grade
- Resource delineation drilling
Negative factors
- True width estimated, not stated
- Narrow intercept length
Evidence · table
“0.64”
Context: 0.82
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU26-02Falcon West · lithiumGrade: 2.61Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- LU26-02
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM.V
Geometry
- Grade
- 2.61
- Grade Unit
- %
- Intercept
- 0.82 m
- From
- 25 m
- To
- 25.82 m
- Hole Depth
- 33 m
- Intercept Depth
- 25 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU26-02:25-25.82
- Mining Method
- open_pit
Location
- Easting
- 321694
- Northing
- 5502692
- CRS
- NAD 83 / UTM Zone 15N
- Elevation
- 327 m
- Azimuth
- 316.5 °
- Dip
- -64.8 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Positive factors
- Exceptional Li2O grade for pegmatite
- Resource delineation drilling
Negative factors
- True width estimated, not stated
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The **Donner Property**(**Li-Cs**) is adjacent to the Mayville Property, and Grid owns 75% of the project."
Metallurgical Results (28)
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 7.59Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU-12-01, Sample 4504
Recovery
- Head Grade
- 7.59
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- High Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“7.59”
Context: 24.8
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 17.2Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU-12-02, Sample 4526
Recovery
- Head Grade
- 17.2
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a very high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Very high Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“17.2”
Context: 47.1
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 2Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU-12-03, Sample 4537
Recovery
- Head Grade
- 2
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a good Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Good Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“2.00”
Context: 16.0
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 12.4Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole ADL24-09, Sample 1299
Recovery
- Head Grade
- 12.4
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a very high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Very high Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“12.4”
Context: 24.0
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 30.4Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-21, Sample 2559
Recovery
- Head Grade
- 30.4
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“30.4”
Context: 77.8
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 30Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-51, Sample 1279
Recovery
- Head Grade
- 30
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“30.0”
Context: 81.0
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 24.1Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-09, Sample 2202
Recovery
- Head Grade
- 24.1
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“24.1”
Context: 76.4
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 27.1Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-08, Sample 2172
Recovery
- Head Grade
- 27.1
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“27.1”
Context: 77.5
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 20.3Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-18, Sample 2481
Recovery
- Head Grade
- 20.3
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“20.3”
Context: 52.4
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 27.4Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU25-01, Sample 2011
Recovery
- Head Grade
- 27.4
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows an exceptionally high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Exceptional Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“27.4”
Context: 75.4
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.64Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU26-02, Sample 3019
Recovery
- Head Grade
- 0.64
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host, but shows a low Cs2O head grade for this sample.
Positive factors
- Pollucite confirmed as dominant cesium host
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“0.64”
Context: 1.40
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.36Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU26-03, Sample 3035
Recovery
- Head Grade
- 0.36
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host, but shows a very low Cs2O head grade for this sample.
Positive factors
- Pollucite confirmed as dominant cesium host
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Very low Cs2O grade
Evidence · table
“0.36”
Context: 0.57
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 10.5Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU26-11, Sample 3195
Recovery
- Head Grade
- 10.5
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a very high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- Very high Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“10.5”
Context: 31.0
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 4.11Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU26-33, Sample 3658
Recovery
- Head Grade
- 4.11
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host and shows a high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host
- High Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“4.11”
Context: 12.5
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.08Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Pollucite Zone, Drill Hole LU26-55, Sample 4141
Recovery
- Head Grade
- 1.08
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host, but shows a low Cs2O head grade for this sample.
Positive factors
- Pollucite confirmed as dominant cesium host
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.08”
Context: 1.32
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.58Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South SPOD Zone, Drill Hole LU25-12, Sample 2296
Recovery
- Head Grade
- 1.58
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the spodumene zone, but at a low head grade.
Positive factors
- Cs2O present in spodumene zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.58”
Context: tr
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.7Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South LEP Zone, Drill Hole LU26-01, Sample 3003
Recovery
- Head Grade
- 0.7
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the lepidolite zone, but at a very low head grade.
Positive factors
- Cs2O present in lepidolite zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Very low Cs2O grade
Evidence · table
“0.70”
Context: 1.00
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.22Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Wall Zone, Drill Hole LU25-19, Sample 2499
Recovery
- Head Grade
- 0.22
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows trace Cs2O present in the wall zone.
Positive factors
- Cs2O present in wall zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Trace Cs2O grade
Evidence · table
“0.22”
Context: 0.00
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.42Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Aplite Zone, Drill Hole LU26-41, Sample 3872
Recovery
- Head Grade
- 0.42
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows trace Cs2O present in the aplite zone.
Positive factors
- Cs2O present in aplite zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Trace Cs2O grade
Evidence · table
“0.42”
Context: tr
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.81Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Contact Zone, Drill Hole LU25-52, Sample 1302
Recovery
- Head Grade
- 1.81
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the contact zone, but at a low head grade.
Positive factors
- Cs2O present in contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.81”
Context: 5.61
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 2.35Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Contact Zone, Drill Hole LU25-65, Sample 1599
Recovery
- Head Grade
- 2.35
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the contact zone at a good head grade.
Positive factors
- Cs2O present in contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Good Cs2O grade
Evidence · table
“2.35”
Context: 0.03
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.45Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Contact Zone, Drill Hole LU25-29, Sample 2805
Recovery
- Head Grade
- 1.45
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the contact zone, but at a low head grade.
Positive factors
- Cs2O present in contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.45”
Context: tr
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.35Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Contact Zone, Drill Hole LU26-05, Sample 3082
Recovery
- Head Grade
- 0.35
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows trace Cs2O present in the contact zone.
Positive factors
- Cs2O present in contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Trace Cs2O grade
Evidence · table
“0.35”
Context: 0.00
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.49Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy South Contact Zone, Drill Hole LU26-12, Sample 3225
Recovery
- Head Grade
- 0.49
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows trace Cs2O present in the contact zone.
Positive factors
- Cs2O present in contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Trace Cs2O grade
Evidence · table
“0.49”
Context: tr
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.08Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy North Contact Zone, Drill Hole ADL24-01, Sample 1076
Recovery
- Head Grade
- 1.08
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the Lucy North contact zone, but at a low head grade.
Positive factors
- Cs2O present in Lucy North contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.08”
Context: 0.03
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 8.81Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy North Pollucite Zone, Drill Hole ADL24-02, Sample 1115
Recovery
- Head Grade
- 8.81
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis confirms pollucite as the dominant cesium host in Lucy North and shows a high Cs2O head grade.
Positive factors
- Pollucite confirmed as dominant cesium host in Lucy North
- High Cs2O grade
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
Evidence · table
“8.81”
Context: 27.1
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 0.96Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Lucy North Contact Zone, Drill Hole LU26-48, Sample 3972
Recovery
- Head Grade
- 0.96
- Head Grade Unit
- %
Lab
- Laboratory
- ACT
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the Lucy North contact zone, but at a low head grade.
Positive factors
- Cs2O present in Lucy North contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“0.96”
Context: tr
QEMSCAN/MLAS analysisFalcon West Property · cesiumHead Grade: 1.08Head Grade Unit: %View all detailsHide details
Identity
- Project
- Falcon West Property
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- Manitoba
- Ticker
- GRDM.V
Test Work
- Program Status
- scoping
- Test Type
- QEMSCAN/MLAS analysis
- Sample
- Artdon Contact Zone, Drill Hole ADL24-21, Sample 1824
Recovery
- Head Grade
- 1.08
- Head Grade Unit
- %
Lab
- Laboratory
- SGS
Review
- Needs Review
- No
- Historical
- No
Dates
- Event date
- 2026-09-08T00:00:00.000Z
Reasoning: Mineralogical analysis shows Cs2O present in the Artdon contact zone, but at a low head grade.
Positive factors
- Cs2O present in Artdon contact zone
Negative factors
- Only mineralogical analysis, not recovery test work
- Bench scale only
- Low Cs2O grade
Evidence · table
“1.08”
Context: 0.05
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.