# Green Bridge Metals Intersects 195.0 Metres Grading 0.25% Cu and  10.18% TiO2 at Titac South, Minnesota; Step-Out Hole Confirms  Mineralization at Previously Untested Geophysical Target

Canonical Atlas analysis: https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff

Original source: https://webfiles-primary.thecse.com/news_releases/neutral/4185/46aca74b-bfe0-48a1-a256-a174aca69b36

Publisher: cse

Original announcement: 2026-09-10T16:07:44.000Z

Analysis by Minestarters Atlas

Atlas analysis published: 2026-10-01T01:23:54.903Z

Atlas analysis updated: 2026-10-01T01:23:54.903Z

- Company: Green Bridge Metals Corporation

- Ticker: GRBM

- Exchange: CSE

- Region: northeastern Minnesota, U.S.A.

- Primary commodity: Titanium

- Secondary commodities: Copper, Vanadium, Pge

- Document categories: Drill results, Other

- Extracted: 2026-10-01 01:23:55 UTC

Narrative sentiment: 0.60 · Bullish

## Minestarters Atlas summary

Green Bridge Metals reported final assay results from its Phase 1 diamond drill program at the Titac Project in Minnesota. Highlights include drill hole TS26-004a intersecting 195.0m grading 0.25% Cu and 10.18% TiO₂, including a higher-grade sub-interval. An exploratory step-out hole, TS26-007, successfully intersected mineralization at a previously untested geophysical target, validating the company's targeting approach. The company plans to accelerate its Phase 2 drilling program to expand the existing titanium resource and include copper, aiming to support a scoping study by the end of 2027.

Reasoning: The drill results confirm and extend mineralization at Titac South, with a significant step-out hole validating the exploration model. The grades for TiO2 are strong, and copper grades are moderate for a bulk tonnage deposit. The acceleration of Phase 2 drilling and plans for a scoping study indicate positive momentum, though the lack of true width disclosure and the inferred nature of the existing resource are minor drawbacks.

- Positive factor: Significant intercept lengths for copper and titanium dioxide, confirming and extending mineralization.

- Positive factor: Successful validation of 3D VTEM inversion modelling as an effective targeting tool for new mineralized zones.

- Positive factor: Step-out drilling intersected mineralization at a previously untested geophysical target, indicating exploration upside.

- Positive factor: All Phase 1 holes intersected sulphide mineralization, consistent with the geological model.

- Positive factor: Acceleration of Phase 2 drilling program to expand existing resource and include copper.

- Negative factor: True widths cannot currently be determined with confidence due to irregular geometry, potentially overstating apparent lengths.

- Negative factor: No specific QA/QC methods \(blanks, standards, duplicates\) disclosed in the release, only analytical methods.

- Negative factor: The existing resource is Inferred, which has a high degree of uncertainty.

Facts used in scoring: 56

## Classification and evidence

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The document explicitly states that 'True widths cannot currently be determined with confidence because of the irregular geometry of the mineralized zones.'

Evidence · text

> All reported intervals are downhole lengths. True widths cannot currently be determined with confidence because of the irregular geometry of the mineralized zones.

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: The release mentions that 'Green Bridge Metals exploration samples were collected in accordance with industry standards and best practices' and names 'Activation Laboratories Ltd.' as the analytical lab, which is independent of the Company. It also mentions a Qualified Person.

Evidence · text

> Green Bridge Metals exploration samples were collected in accordance with industry standards and best practices. All samples were submitted to Activation Laboratories Ltd. in Thunder Bay, Ontario, for geochemical analysis. Analytical methods included fire assay with ICP-OES analysis for gold and platinum group elements, sodium peroxide fusion with ICP-OES analysis for trace elements, and lithium metaborate fused-disc XRF analysis for major element composition. Activation Laboratories Ltd. is independent of the Company.

**QP/CP Signed**

Polarity: positive

Story-specific tag

Definition: Qualified Person \(QP\) or Competent Person \(CP\) named and signed off — a member of a recognized professional association \(e.g., AusIMM, SME, AIG, P.Geo\) with relevant experience.

Why it applies: The news release states that 'George Hudak, Chief Geologist of Green Bridge Metals Corporation, who is a Qualified Person as defined by NI 43-101' reviewed and approved the scientific and technical information.

Evidence · text

> The scientific and technical information contained in this news release has been reviewed and approved by George Hudak, Chief Geologist of Green Bridge Metals Corporation, who is a Qualified Person as defined by NI 43-101.

**Step-Out Extension**

Polarity: positive

Definition: Mineralization extended beyond the previously known limit.

Why it applies: The document highlights an 'Exploratory step-out hole TS26-007, testing a previously untested geophysical target' which successfully intersected mineralization.

Evidence · text

> Exploratory step-out hole TS26-007, testing a previously untested geophysical target, returned 12.0 m @ 0.20% Cu, 8.33% TiO₂, 0.15% V₂O₅, intersecting mineralization associated with the geophysical anomaly.

**Inferred Resource**

Polarity: negative

Story-specific tag

Definition: Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: The document mentions an 'inferred mineral resource estimate of 46.6 million tonnes grading 15% TiO₂' at Titac South.

Evidence · text

> Titac South hosts an inferred mineral resource estimate of 46.6 million tonnes grading 15% TiO₂

## Extracted facts

Stored fact records: 56. Some facts used in scoring do not have a stored record.

## Drill Results (56)

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-0)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept confirms existing mineralization with a good length and moderate copper grade for an Oxide Ultramafic Intrusion deposit, contributing positively to the project's understanding.

- Positive factor: Significant intercept length of 195.0m.

- Positive factor: Moderate copper grade for a bulk tonnage deposit.

- Positive factor: Confirms existing mineralization.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> At Titac South, drill hole TS26-004a intersected 195.0m grading 0.25% Cu and 10.18% TiO₂, including 62.0m grading 0.29% Cu and 10.54% TiO₂. The core hole transected the southwest portion of the mineralized zone from southeast to northwest and confirmed the existing mineralization.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-1)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 10.18
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept confirms existing mineralization with a good length and strong titanium dioxide grade, which is a primary commodity for the project, contributing positively to the project's understanding.

- Positive factor: Significant intercept length of 195.0m.

- Positive factor: Strong titanium dioxide grade for an Oxide Ultramafic Intrusion deposit.

- Positive factor: Confirms existing mineralization.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> At Titac South, drill hole TS26-004a intersected 195.0m grading 0.25% Cu and 10.18% TiO₂, including 62.0m grading 0.29% Cu and 10.54% TiO₂. The core hole transected the southwest portion of the mineralized zone from southeast to northwest and confirmed the existing mineralization.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-2)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a higher-grade sub-interval within a broader intercept, indicating a more concentrated zone of copper mineralization.

- Positive factor: Good intercept length of 62.0m.

- Positive factor: Higher copper grade than the broader interval.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> At Titac South, drill hole TS26-004a intersected 195.0m grading 0.25% Cu and 10.18% TiO₂, including 62.0m grading 0.29% Cu and 10.54% TiO₂.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-3)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 10.54
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a higher-grade sub-interval within a broader intercept, indicating a more concentrated zone of titanium dioxide mineralization.

- Positive factor: Good intercept length of 62.0m.

- Positive factor: Strong titanium dioxide grade, slightly higher than the broader interval.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> At Titac South, drill hole TS26-004a intersected 195.0m grading 0.25% Cu and 10.18% TiO₂, including 62.0m grading 0.29% Cu and 10.54% TiO₂.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-4)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept is highly novel as it validates the company's exploration model by confirming mineralization at a new target, opening up significant exploration potential, despite the moderate grade and narrow width.

- Positive factor: Successfully intersected mineralization at a previously untested geophysical target.

- Positive factor: Validates the 3D VTEM inversion model as an effective targeting tool.

- Positive factor: Moderate copper grade for a bulk tonnage deposit.

- Negative factor: Relatively narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> Exploratory step-out hole TS26-007, testing a previously untested geophysical target, returned 12.0 m @ 0.20% Cu, 8.33% TiO₂, 0.15% V₂O₅, intersecting mineralization associated with the geophysical anomaly.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-5)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 8.33
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept is highly novel as it validates the company's exploration model by confirming mineralization at a new target, opening up significant exploration potential, despite the narrow width.

- Positive factor: Successfully intersected mineralization at a previously untested geophysical target.

- Positive factor: Validates the 3D VTEM inversion model as an effective targeting tool.

- Positive factor: Strong titanium dioxide grade.

- Negative factor: Relatively narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> Exploratory step-out hole TS26-007, testing a previously untested geophysical target, returned 12.0 m @ 0.20% Cu, 8.33% TiO₂, 0.15% V₂O₅, intersecting mineralization associated with the geophysical anomaly.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-6)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept is highly novel as it validates the company's exploration model by confirming mineralization at a new target, opening up significant exploration potential, despite the narrow width.

- Positive factor: Successfully intersected mineralization at a previously untested geophysical target.

- Positive factor: Validates the 3D VTEM inversion model as an effective targeting tool.

- Negative factor: Relatively narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · text

> Exploratory step-out hole TS26-007, testing a previously untested geophysical target, returned 12.0 m @ 0.20% Cu, 8.33% TiO₂, 0.15% V₂O₅, intersecting mineralization associated with the geophysical anomaly.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-7)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows very broad, but low-grade copper mineralization, which is common in bulk tonnage deposits but may not be economically significant on its own.

- Positive factor: Very long intercept length of 272.8m.

- Negative factor: Weak copper grade for a bulk tonnage deposit.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.08

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-8)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 4.53
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows very broad, moderate-grade titanium dioxide mineralization, which is positive for a bulk tonnage deposit.

- Positive factor: Very long intercept length of 272.8m.

- Positive factor: Moderate titanium dioxide grade for a bulk tonnage deposit.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 4.53

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-9)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 1.34
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows very broad, good-grade vanadium mineralization, which could be a valuable byproduct.

- Positive factor: Very long intercept length of 272.8m.

- Positive factor: Good vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 1.34

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-10)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 14.1
- Grade Unit: ppb
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a very long intercept, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Very long intercept length of 272.8m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 14.1

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-11)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a moderate length with a weak copper grade, contributing to the overall mineralization but not highly significant on its own.

- Positive factor: Good intercept length of 34.8m.

- Negative factor: Weak copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.13

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-12)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 5.89
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a moderate length with a moderate titanium dioxide grade, contributing positively to the overall mineralization.

- Positive factor: Good intercept length of 34.8m.

- Positive factor: Moderate titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 5.89

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-13)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a moderate length with a weak vanadium grade, which is less significant.

- Positive factor: Good intercept length of 34.8m.

- Negative factor: Weak vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.06

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-14)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 15
- Grade Unit: ppb
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a good length, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Good intercept length of 34.8m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 15.0

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-15)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a good length with a weak copper grade, contributing to the overall mineralization but not highly significant on its own.

- Positive factor: Good intercept length of 70.0m.

- Negative factor: Weak copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.14

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-16)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 7.54
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a good length with a moderate titanium dioxide grade, contributing positively to the overall mineralization.

- Positive factor: Good intercept length of 70.0m.

- Positive factor: Moderate titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 7.54

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-17)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This sub-interval shows a good length with a weak vanadium grade, which is less significant.

- Positive factor: Good intercept length of 70.0m.

- Negative factor: Weak vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.09

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-18)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 18.7
- Grade Unit: ppb
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a good length, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Good intercept length of 70.0m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 18.7

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-19)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow intercept shows a moderate copper grade, indicating a higher-grade zone within the broader mineralization.

- Positive factor: Moderate copper grade.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.25

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-20)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 11.23
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow intercept shows a strong titanium dioxide grade, indicating a higher-grade zone within the broader mineralization.

- Positive factor: Strong titanium dioxide grade.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 11.23

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-21)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow intercept shows a moderate vanadium grade, which is a positive byproduct.

- Positive factor: Moderate vanadium grade.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.11

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-22)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 20.8
- Grade Unit: ppb
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: The PGE grade is very low and unlikely to be economically significant, even within this narrow interval.

- Negative factor: Very low PGE grade.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 20.8

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-23)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length and grade for copper, contributing to the overall mineralization.

- Positive factor: Moderate intercept length of 20.0m.

- Positive factor: Moderate copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.19

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-24)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 6.17
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length and grade for titanium dioxide, contributing positively to the overall mineralization.

- Positive factor: Moderate intercept length of 20.0m.

- Positive factor: Moderate titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 6.17

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-25)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length with a weak vanadium grade, which is less significant.

- Positive factor: Moderate intercept length of 20.0m.

- Negative factor: Weak vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.08

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-001

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-26)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 21.5
- Grade Unit: ppb
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 26.2 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: The PGE grade is very low and unlikely to be economically significant, even within this interval.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 21.5

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-27)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a very long intercept with a moderate copper grade, indicating significant bulk tonnage potential.

- Positive factor: Exceptional intercept length of 267.0m.

- Positive factor: Moderate copper grade for a bulk tonnage deposit.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.23

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-28)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 10.28
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a very long intercept with a strong titanium dioxide grade, indicating significant bulk tonnage potential for the primary commodity.

- Positive factor: Exceptional intercept length of 267.0m.

- Positive factor: Strong titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 10.28

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-29)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a very long intercept with a moderate vanadium grade, indicating significant byproduct potential.

- Positive factor: Exceptional intercept length of 267.0m.

- Positive factor: Moderate vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.10

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-30)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 22.1
- Grade Unit: ppb
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a very long intercept, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Exceptional intercept length of 267.0m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 22.1

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-31)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a good length with a moderate copper grade, indicating a higher-grade zone near surface.

- Positive factor: Good intercept length of 24.0m.

- Positive factor: Moderate copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.32

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-32)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 10.92
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a good length with a strong titanium dioxide grade, indicating a higher-grade zone near surface for the primary commodity.

- Positive factor: Good intercept length of 24.0m.

- Positive factor: Strong titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 10.92

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-33)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a good length with a moderate vanadium grade, indicating a positive byproduct near surface.

- Positive factor: Good intercept length of 24.0m.

- Positive factor: Moderate vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.11

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-34)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 107
- Grade Unit: ppb
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a good length, the PGE grade is low and unlikely to be economically significant.

- Positive factor: Good intercept length of 24.0m.

- Negative factor: Low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 107.0

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-35)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a very long intercept with a moderate vanadium grade, indicating significant byproduct potential.

- Positive factor: Exceptional intercept length of 195.0m.

- Positive factor: Moderate vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.09

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-36)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 13.9
- Grade Unit: ppb
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a very long intercept, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Exceptional intercept length of 195.0m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 13.9

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-37)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This is a good length intercept with a moderate vanadium grade, indicating a positive byproduct.

- Positive factor: Good intercept length of 62.0m.

- Positive factor: Moderate vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.09

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-38)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 13.9
- Grade Unit: ppb
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: While a good length, the PGE grade is very low and unlikely to be economically significant.

- Positive factor: Good intercept length of 62.0m.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 13.9

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-39)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length and grade for copper, contributing to the overall mineralization.

- Positive factor: Moderate intercept length of 20.0m.

- Positive factor: Moderate copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.18

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-40)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 12.55
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length and strong grade for titanium dioxide, contributing positively to the overall mineralization.

- Positive factor: Moderate intercept length of 20.0m.

- Positive factor: Strong titanium dioxide grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 12.55

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-41)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This intercept shows a moderate length and good grade for vanadium, indicating a positive byproduct.

- Positive factor: Moderate intercept length of 20.0m.

- Positive factor: Good vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.14

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-004a

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-42)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 11.4
- Grade Unit: ppb
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: OUI
- Program: mixed
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: The PGE grade is very low and unlikely to be economically significant, even within this interval.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 11.4

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-43)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This very long intercept, while low-grade for copper, is highly novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Exceptional intercept length of 362.0m.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Weak copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.06

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-44)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 3.4
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This very long intercept, with a moderate titanium dioxide grade, is highly novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Exceptional intercept length of 362.0m.

- Positive factor: Moderate titanium dioxide grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 3.40

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-45)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This very long intercept, while low-grade for vanadium, is highly novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Exceptional intercept length of 362.0m.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Weak vanadium grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.06

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-46)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 12.6
- Grade Unit: ppb
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This very long intercept, while very low-grade for PGE, is highly novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Exceptional intercept length of 362.0m.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 12.6

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-47)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow, weak-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Narrow intercept length.

- Negative factor: Weak copper grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.10

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-48)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 5.92
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow, moderate-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Moderate titanium dioxide grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 5.92

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-49)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow, good-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Good vanadium grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Narrow intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.16

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-50)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 9.6
- Grade Unit: ppb
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow, very low-grade PGE intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Narrow intercept length.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 9.6

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-51)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 17.7
- Grade Unit: ppb
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This narrow, very low-grade PGE intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Narrow intercept length.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 17.7

Context: 12.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-52)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This moderate-length, moderate-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Moderate copper grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Moderate intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.17

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-53)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 6.19
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This moderate-length, moderate-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Moderate titanium dioxide grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Moderate intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 6.19

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-54)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This moderate-length, moderate-grade intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Moderate vanadium grade.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Moderate intercept length.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 0.10

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-staging.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--f45abd16-cf00-4c0e-bf26-b974a6b183ff#fact-drill-facts-55)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: usa
- Reported Region: usa
- Ticker: GRBM

#### Geometry

- Grade: 23.2
- Grade Unit: ppb
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 20 m

#### Classification

- Deposit Type: OUI
- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: open\_pit

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-10T00:00:00.000Z

Reasoning: This moderate-length, very low-grade PGE intercept is still novel as it confirms mineralization at a new target, validating the exploration model.

- Positive factor: Intersected mineralization at a previously untested geophysical target.

- Negative factor: Moderate intercept length.

- Negative factor: Very low PGE grade.

- Negative factor: True width not determined, potentially overstating length.

Evidence · table

> 23.2

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
