Gold X2 Drilling Intersects a Combined 172.0m of 0.96 g/t Au in Infill Drilling
Original announcement by orestocks on
- Company
- Gold X2 Mining Inc.
- Ticker
- AUXX.V
- Exchange
- Unavailable
- Region
- Northwest Ontario, Canada
- Primary commodity
- Gold
- Secondary commodities
- Silver
- Document categories
- Drill results, Resource update
- Extracted
- 2026-10-14 11:44:10 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Gold X2 Mining announced positive infill drilling results from its Moss Gold Project in Northwest Ontario, Canada, targeting the Main and Southwest Zones. The program, aimed at converting Inferred to Indicated resources, delivered multiple wide zones of moderate-grade gold mineralization, showing positive reconciliation with the existing resource model despite some lower grades than predicted. These results are expected to significantly impact the updated Mineral Resource Estimate targeted for Q1 2027.
Reasoning: Infill drilling at the Moss Gold Project returned wide, moderate-grade gold intercepts that show positive reconciliation with the resource model, reinforcing confidence for an upcoming resource update, despite some localized geological model discrepancies and lower grades than initially modelled, which were offset by wider intercepts.
Positive factors
- infill_drilling_positive_reconciliation
- true_width_disclosed
- qaqc_disclosed
- qp_signed
- open_pit_potential
- resource_conversion
- wide_intercepts
Negative factors
- geological_model_discrepancies
Facts used in scoring: 101
Extracted facts
Stored fact records: 101. Some facts used in scoring do not have a stored record.
Drill Results (101)
MMD-26-430Moss · goldGrade: 0.96Grade Unit: g/tIntercept: 172 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.96
- Grade Unit
- g/t
- Intercept
- 172 m
- From
- 195 m
- To
- 367 m
- Hole Depth
- 461 m
- Intercept Depth
- 195 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:195-367
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Very wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
Evidence · text
“172.0m of 0.96 g/t Au from 195.0m in MMD-26-430”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 0.43Grade Unit: g/tIntercept: 9.35 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 9.35 m
- True Width
- 5.9 m
- From
- 207.65 m
- To
- 217 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:207.65-217
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.43”
Context: 9.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 1.35Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.35
- Grade Unit
- g/t
- Intercept
- 7 m
- True Width
- 4.5 m
- From
- 242 m
- To
- 249 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:242-249
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.35”
Context: 7.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 0.55Grade Unit: g/tIntercept: 11.5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 11.5 m
- True Width
- 7.4 m
- From
- 302 m
- To
- 313.5 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:302-313.5
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.55”
Context: 11.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 0.65Grade Unit: g/tIntercept: 14.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 14.8 m
- True Width
- 9.7 m
- From
- 371 m
- To
- 385.8 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:371-385.8
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.65”
Context: 14.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 1.02Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 7 m
- True Width
- 4.6 m
- From
- 371 m
- To
- 378 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:371-378
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.02”
Context: 7.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-420Moss · goldGrade: 0.95Grade Unit: g/tIntercept: 6.95 mView all detailsHide details
Identity
- Hole ID
- MMD-26-420
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.95
- Grade Unit
- g/t
- Intercept
- 6.95 m
- True Width
- 4.6 m
- From
- 399.45 m
- To
- 406.4 m
- Hole Depth
- 411 m
- Intercept Depth
- 207.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-420:399.45-406.4
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668097
- Northing
- 5378309
- Elevation
- 450 m
- Azimuth
- 140 °
- Dip
- -54.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“0.95”
Context: 6.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-421Moss · goldGrade: 0.35Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- MMD-26-421
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 2.75 m
- True Width
- 2.1 m
- From
- 333 m
- To
- 335.75 m
- Hole Depth
- 555 m
- Intercept Depth
- 333 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-421:333-335.75
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668181
- Northing
- 5378450
- Elevation
- 443 m
- Azimuth
- 126.1 °
- Dip
- -49.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.35”
Context: 2.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-421Moss · goldGrade: 0.45Grade Unit: g/tIntercept: 17.25 mView all detailsHide details
Identity
- Hole ID
- MMD-26-421
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 17.25 m
- True Width
- 13.6 m
- From
- 396.75 m
- To
- 414 m
- Hole Depth
- 555 m
- Intercept Depth
- 333 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-421:396.75-414
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668181
- Northing
- 5378450
- Elevation
- 443 m
- Azimuth
- 126.1 °
- Dip
- -49.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.45”
Context: 17.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-421Moss · goldGrade: 0.55Grade Unit: g/tIntercept: 60.65 mView all detailsHide details
Identity
- Hole ID
- MMD-26-421
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 60.65 m
- True Width
- 49 m
- From
- 471.45 m
- To
- 532.1 m
- Hole Depth
- 555 m
- Intercept Depth
- 333 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-421:471.45-532.1
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668181
- Northing
- 5378450
- Elevation
- 443 m
- Azimuth
- 126.1 °
- Dip
- -49.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.55”
Context: 60.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 49
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-421Moss · goldGrade: 2.5Grade Unit: g/tIntercept: 5.95 mView all detailsHide details
Identity
- Hole ID
- MMD-26-421
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.5
- Grade Unit
- g/t
- Intercept
- 5.95 m
- True Width
- 4.8 m
- From
- 472 m
- To
- 477.95 m
- Hole Depth
- 555 m
- Intercept Depth
- 333 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-421:472-477.95
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668181
- Northing
- 5378450
- Elevation
- 443 m
- Azimuth
- 126.1 °
- Dip
- -49.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.50”
Context: 5.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-423Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 3.65 mView all detailsHide details
Identity
- Hole ID
- MMD-26-423
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 3.65 m
- True Width
- 2.4 m
- From
- 46.4 m
- To
- 50.05 m
- Hole Depth
- 117 m
- Intercept Depth
- 46.4 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-423:46.4-50.05
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 669009
- Northing
- 5379313
- Elevation
- 427 m
- Azimuth
- 322.1 °
- Dip
- -48.8 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 3.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-423Moss · goldGrade: 0.33Grade Unit: g/tIntercept: 24.75 mView all detailsHide details
Identity
- Hole ID
- MMD-26-423
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.33
- Grade Unit
- g/t
- Intercept
- 24.75 m
- True Width
- 16.6 m
- From
- 68.4 m
- To
- 93.15 m
- Hole Depth
- 117 m
- Intercept Depth
- 46.4 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-423:68.4-93.15
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 669009
- Northing
- 5379313
- Elevation
- 427 m
- Azimuth
- 322.1 °
- Dip
- -48.8 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.33”
Context: 24.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 16.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.35Grade Unit: g/tIntercept: 8.85 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 8.85 m
- True Width
- 5.3 m
- From
- 64.65 m
- To
- 73.5 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:64.65-73.5
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.35”
Context: 8.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.71Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.71
- Grade Unit
- g/t
- Intercept
- 4.1 m
- True Width
- 2.5 m
- From
- 144.9 m
- To
- 149 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:144.9-149
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.71”
Context: 4.10
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.43Grade Unit: g/tIntercept: 40 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 40 m
- True Width
- 25.3 m
- From
- 212 m
- To
- 252 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:212-252
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.43”
Context: 40.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 25.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 2.99Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.99
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 1.9 m
- From
- 246 m
- To
- 249 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:246-249
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.99”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.58Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 3.3 m
- True Width
- 2.1 m
- From
- 272.6 m
- To
- 275.9 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:272.6-275.9
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.58”
Context: 3.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.46Grade Unit: g/tIntercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 5.6 m
- True Width
- 3.6 m
- From
- 286.4 m
- To
- 292 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:286.4-292
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.46”
Context: 5.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.42Grade Unit: g/tIntercept: 69.55 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.42
- Grade Unit
- g/t
- Intercept
- 69.55 m
- True Width
- 45.3 m
- From
- 303.4 m
- To
- 372.95 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:303.4-372.95
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.42”
Context: 69.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 45.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 1.38Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.38
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 5.7 m
- From
- 356.2 m
- To
- 365 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:356.2-365
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.38”
Context: 8.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.6Grade Unit: g/tIntercept: 58.5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.6
- Grade Unit
- g/t
- Intercept
- 58.5 m
- True Width
- 38.6 m
- From
- 391.5 m
- To
- 450 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:391.5-450
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.60”
Context: 58.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 38.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 1.33Grade Unit: g/tIntercept: 9.5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.33
- Grade Unit
- g/t
- Intercept
- 9.5 m
- True Width
- 6.2 m
- From
- 396.5 m
- To
- 406 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:396.5-406
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.33”
Context: 9.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 2.25Grade Unit: g/tIntercept: 5.55 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.25
- Grade Unit
- g/t
- Intercept
- 5.55 m
- True Width
- 3.7 m
- From
- 417.95 m
- To
- 423.5 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:417.95-423.5
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.25”
Context: 5.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 0.68Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.68
- Grade Unit
- g/t
- Intercept
- 21 m
- True Width
- 14 m
- From
- 462 m
- To
- 483 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:462-483
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.68”
Context: 21.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-425Moss · goldGrade: 1.04Grade Unit: g/tIntercept: 11.1 mView all detailsHide details
Identity
- Hole ID
- MMD-26-425
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.04
- Grade Unit
- g/t
- Intercept
- 11.1 m
- True Width
- 7.4 m
- From
- 462.9 m
- To
- 474 m
- Hole Depth
- 513 m
- Intercept Depth
- 64.65 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-425:462.9-474
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668733
- Northing
- 5379231
- Elevation
- 436 m
- Azimuth
- 137 °
- Dip
- -53.7 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.04”
Context: 11.10
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-426Moss · goldGrade: 1.28Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-426
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.28
- Grade Unit
- g/t
- Intercept
- 3.8 m
- True Width
- 2.6 m
- From
- 6.2 m
- To
- 10 m
- Hole Depth
- 132 m
- Intercept Depth
- 6.2 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-426:6.2-10
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668957
- Northing
- 5379251
- Elevation
- 428 m
- Azimuth
- 322.2 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.28”
Context: 3.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-426Moss · goldGrade: 1.52Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-426
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.52
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.1 m
- From
- 7 m
- To
- 10 m
- Hole Depth
- 132 m
- Intercept Depth
- 6.2 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-426:7-10
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668957
- Northing
- 5379251
- Elevation
- 428 m
- Azimuth
- 322.2 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“1.52”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-426Moss · goldGrade: 0.64Grade Unit: g/tIntercept: 15.9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-426
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.64
- Grade Unit
- g/t
- Intercept
- 15.9 m
- True Width
- 11.1 m
- From
- 52.1 m
- To
- 68 m
- Hole Depth
- 132 m
- Intercept Depth
- 6.2 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-426:52.1-68
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668957
- Northing
- 5379251
- Elevation
- 428 m
- Azimuth
- 322.2 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.64”
Context: 15.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 11.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-426Moss · goldGrade: 1.39Grade Unit: g/tIntercept: 4.85 mView all detailsHide details
Identity
- Hole ID
- MMD-26-426
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.39
- Grade Unit
- g/t
- Intercept
- 4.85 m
- True Width
- 3.4 m
- From
- 59 m
- To
- 63.85 m
- Hole Depth
- 132 m
- Intercept Depth
- 6.2 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-426:59-63.85
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668957
- Northing
- 5379251
- Elevation
- 428 m
- Azimuth
- 322.2 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.39”
Context: 4.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.36Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 5.1 m
- From
- 180 m
- To
- 188 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:180-188
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.36”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.46Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.3 m
- From
- 231 m
- To
- 233 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:231-233
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.46”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.39Grade Unit: g/tIntercept: 3.85 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 3.85 m
- True Width
- 2.6 m
- From
- 293 m
- To
- 296.85 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:293-296.85
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.39”
Context: 3.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.53Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 4 m
- True Width
- 2.7 m
- From
- 311 m
- To
- 315 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:311-315
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.53”
Context: 4.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.3Grade Unit: g/tIntercept: 8.1 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 8.1 m
- True Width
- 5.5 m
- From
- 324.9 m
- To
- 333 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:324.9-333
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.30”
Context: 8.10
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 2.45Grade Unit: g/tIntercept: 6.35 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.45
- Grade Unit
- g/t
- Intercept
- 6.35 m
- True Width
- 4.4 m
- From
- 366.55 m
- To
- 372.9 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:366.55-372.9
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.45”
Context: 6.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 2.77Grade Unit: g/tIntercept: 5.45 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.77
- Grade Unit
- g/t
- Intercept
- 5.45 m
- True Width
- 3.8 m
- From
- 366.55 m
- To
- 372 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:366.55-372
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.77”
Context: 5.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.53Grade Unit: g/tIntercept: 39 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 39 m
- True Width
- 27.9 m
- From
- 413 m
- To
- 452 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:413-452
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.53”
Context: 39.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 1.03Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.03
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 7.3 m
- From
- 414 m
- To
- 424.3 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:414-424.3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.03”
Context: 10.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 0.58Grade Unit: g/tIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 18 m
- True Width
- 13.1 m
- From
- 473 m
- To
- 491 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:473-491
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.58”
Context: 18.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-428Moss · goldGrade: 2.21Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-428
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.21
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.5 m
- From
- 486 m
- To
- 488 m
- Hole Depth
- 507 m
- Intercept Depth
- 180 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-428:486-488
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668161
- Northing
- 5378336
- Elevation
- 447 m
- Azimuth
- 136.1 °
- Dip
- -53.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.21”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 8.62Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 8.62
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.3 m
- From
- 203 m
- To
- 205 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:203-205
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Exceptional-grade gold intercept from infill drilling.
Positive factors
- exceptional_grade
- true_width_disclosed
Evidence · table
“8.62”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.55Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.55
- Grade Unit
- g/t
- Intercept
- 2.8 m
- True Width
- 1.9 m
- From
- 276.15 m
- To
- 278.95 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:276.15-278.95
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.55”
Context: 2.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.37Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.37
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 5.5 m
- From
- 302 m
- To
- 310 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:302-310
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.37”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.49Grade Unit: g/tIntercept: 5.9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 5.9 m
- True Width
- 4.2 m
- From
- 374.1 m
- To
- 380 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:374.1-380
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.49”
Context: 5.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.32Grade Unit: g/tIntercept: 25 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 25 m
- True Width
- 17.8 m
- From
- 397 m
- To
- 422 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:397-422
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.32”
Context: 25.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 17.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.54Grade Unit: g/tIntercept: 12.6 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 12.6 m
- True Width
- 9.1 m
- From
- 461.05 m
- To
- 473.65 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:461.05-473.65
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.54”
Context: 12.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.58Grade Unit: g/tIntercept: 39 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 39 m
- True Width
- 28.8 m
- From
- 489 m
- To
- 528 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:489-528
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.58”
Context: 39.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 28.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-429Moss · goldGrade: 0.31Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-429
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 3.7 m
- From
- 538.35 m
- To
- 543.35 m
- Hole Depth
- 546.3 m
- Intercept Depth
- 203 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-429:538.35-543.35
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668144
- Northing
- 5378379
- Elevation
- 442 m
- Azimuth
- 124.1 °
- Dip
- -53.4 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.31”
Context: 5.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.41Grade Unit: g/tIntercept: 9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 9 m
- True Width
- 5.4 m
- From
- 8 m
- To
- 17 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:8-17
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.41”
Context: 9.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 1.46Grade Unit: g/tIntercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.46
- Grade Unit
- g/t
- Intercept
- 12.2 m
- True Width
- 7.4 m
- From
- 34 m
- To
- 46.2 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:34-46.2
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.46”
Context: 12.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 2.63Grade Unit: g/tIntercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.63
- Grade Unit
- g/t
- Intercept
- 6.2 m
- True Width
- 3.7 m
- From
- 40 m
- To
- 46.2 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:40-46.2
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.63”
Context: 6.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.52Grade Unit: g/tIntercept: 31.15 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.52
- Grade Unit
- g/t
- Intercept
- 31.15 m
- True Width
- 18.8 m
- From
- 71.85 m
- To
- 103 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:71.85-103
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.52”
Context: 31.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.54Grade Unit: g/tIntercept: 2.9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 2.9 m
- True Width
- 1.8 m
- From
- 134.3 m
- To
- 137.2 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:134.3-137.2
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.54”
Context: 2.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.49Grade Unit: g/tIntercept: 26 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 26 m
- True Width
- 15.8 m
- From
- 155 m
- To
- 181 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:155-181
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.49”
Context: 26.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 15.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 1.09Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.09
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 4.9 m
- From
- 168 m
- To
- 176 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:168-176
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.09”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 1.31Grade Unit: g/tIntercept: 39 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.31
- Grade Unit
- g/t
- Intercept
- 39 m
- True Width
- 23.7 m
- From
- 195 m
- To
- 234 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:195-234
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
- true_width_disclosed
Evidence · table
“1.31”
Context: 39.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 23.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 2.44Grade Unit: g/tIntercept: 18.5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.44
- Grade Unit
- g/t
- Intercept
- 18.5 m
- True Width
- 11.3 m
- From
- 209.5 m
- To
- 228 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:209.5-228
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, strong-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- strong_grade
- true_width_disclosed
Evidence · table
“2.44”
Context: 18.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 11.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.97Grade Unit: g/tIntercept: 67 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.97
- Grade Unit
- g/t
- Intercept
- 67 m
- True Width
- 41.1 m
- From
- 255 m
- To
- 322 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:255-322
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Very wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
- true_width_disclosed
Evidence · table
“0.97”
Context: 67.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 41.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 1.57Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.57
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.2 m
- From
- 272 m
- To
- 274 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:272-274
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“1.57”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 2.1Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.1
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.2 m
- From
- 282 m
- To
- 284 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:282-284
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.10”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 3.74Grade Unit: g/tIntercept: 2.4 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 3.74
- Grade Unit
- g/t
- Intercept
- 2.4 m
- True Width
- 1.5 m
- From
- 305.6 m
- To
- 308 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:305.6-308
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Exceptional-grade gold intercept from infill drilling.
Positive factors
- exceptional_grade
- true_width_disclosed
Evidence · table
“3.74”
Context: 2.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 15.85Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 15.85
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.2 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:320-322
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Bonanza-grade gold intercept from infill drilling.
Positive factors
- bonanza_intercept
- true_width_disclosed
Evidence · table
“15.85”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.96Grade Unit: g/tIntercept: 33 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.96
- Grade Unit
- g/t
- Intercept
- 33 m
- True Width
- 20.2 m
- From
- 334 m
- To
- 367 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:334-367
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
- true_width_disclosed
Evidence · table
“0.96”
Context: 33.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 20.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 2.5Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 2.5
- Grade Unit
- g/t
- Intercept
- 7 m
- True Width
- 4.3 m
- From
- 334 m
- To
- 341 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:334-341
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“2.50”
Context: 7.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 1.37Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.37
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 4.9 m
- From
- 358 m
- To
- 366 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:358-366
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.37”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-430Moss · goldGrade: 0.46Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- MMD-26-430
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 20 m
- True Width
- 12.3 m
- From
- 420 m
- To
- 440 m
- Hole Depth
- 461 m
- Intercept Depth
- 8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-430:420-440
- Mining Method
- open_pit
Location
- Location
- Southwest Zone
- Easting
- 668902
- Northing
- 5379229
- Elevation
- 431 m
- Azimuth
- 140.1 °
- Dip
- -53.6 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.46”
Context: 20.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.31Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 14 m
- True Width
- 8.2 m
- From
- 10 m
- To
- 24 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:10-24
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.31”
Context: 14.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 1.27Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.27
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.2 m
- From
- 22 m
- To
- 24 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:22-24
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.27”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 10 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 10 m
- True Width
- 5.9 m
- From
- 28 m
- To
- 38 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:28-38
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.72Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.72
- Grade Unit
- g/t
- Intercept
- 3.8 m
- True Width
- 2.3 m
- From
- 73.2 m
- To
- 77 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:73.2-77
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.72”
Context: 3.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 9 m
- True Width
- 5.5 m
- From
- 107 m
- To
- 116 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:107-116
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 9.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.47Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.47
- Grade Unit
- g/t
- Intercept
- 2.5 m
- True Width
- 1.5 m
- From
- 141.5 m
- To
- 144 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:141.5-144
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.47”
Context: 2.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.32Grade Unit: g/tIntercept: 19.2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 19.2 m
- True Width
- 12.3 m
- From
- 194.8 m
- To
- 214 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:194.8-214
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.32”
Context: 19.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 12.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.39Grade Unit: g/tIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 27 m
- True Width
- 17.4 m
- From
- 226 m
- To
- 253 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:226-253
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.39”
Context: 27.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 17.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.3 m
- From
- 291 m
- To
- 293 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:291-293
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.68Grade Unit: g/tIntercept: 28.4 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.68
- Grade Unit
- g/t
- Intercept
- 28.4 m
- True Width
- 18.9 m
- From
- 309.9 m
- To
- 338.3 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:309.9-338.3
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.68”
Context: 28.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 18.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 1.63Grade Unit: g/tIntercept: 4.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.63
- Grade Unit
- g/t
- Intercept
- 4.8 m
- True Width
- 3.2 m
- From
- 328 m
- To
- 332.8 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:328-332.8
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Strong-grade gold intercept from infill drilling.
Positive factors
- strong_grade
- true_width_disclosed
Evidence · table
“1.63”
Context: 4.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.53Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.4 m
- From
- 380 m
- To
- 382 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:380-382
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.53”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.43Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 3.4 m
- From
- 398 m
- To
- 403 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:398-403
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.43”
Context: 5.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-433Moss · goldGrade: 0.37Grade Unit: g/tIntercept: 38.35 mView all detailsHide details
Identity
- Hole ID
- MMD-26-433
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.37
- Grade Unit
- g/t
- Intercept
- 38.35 m
- True Width
- 26.2 m
- From
- 422.65 m
- To
- 461 m
- Hole Depth
- 468 m
- Intercept Depth
- 10 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-433:422.65-461
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668202
- Northing
- 5378273
- Elevation
- 455 m
- Azimuth
- 120 °
- Dip
- -54.3 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.37”
Context: 38.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 26.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.4Grade Unit: g/tIntercept: 14.65 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 14.65 m
- True Width
- 10.2 m
- From
- 188.35 m
- To
- 203 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:188.35-203
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.40”
Context: 14.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 10.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 1.21Grade Unit: g/tIntercept: 3.55 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.21
- Grade Unit
- g/t
- Intercept
- 3.55 m
- True Width
- 2.5 m
- From
- 198.45 m
- To
- 202 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:198.45-202
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.21”
Context: 3.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.56Grade Unit: g/tIntercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.56
- Grade Unit
- g/t
- Intercept
- 3.2 m
- True Width
- 2.3 m
- From
- 227.3 m
- To
- 230.5 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:227.3-230.5
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.56”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.61Grade Unit: g/tIntercept: 4.8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 4.8 m
- True Width
- 3.4 m
- From
- 244 m
- To
- 248.8 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:244-248.8
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.61”
Context: 4.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.47Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.47
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.2 m
- From
- 295 m
- To
- 298 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:295-298
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.47”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.59Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.59
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.2 m
- From
- 310 m
- To
- 313 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:310-313
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.59”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.58Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 345 m
- To
- 348 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:345-348
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.58”
Context: 3.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.5 m
- From
- 353 m
- To
- 355 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:353-355
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.34Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 8 m
- True Width
- 6.1 m
- From
- 359 m
- To
- 367 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:359-367
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.34”
Context: 8.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.76Grade Unit: g/tIntercept: 28 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.76
- Grade Unit
- g/t
- Intercept
- 28 m
- True Width
- 21.4 m
- From
- 379 m
- To
- 407 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:379-407
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
- true_width_disclosed
Evidence · table
“0.76”
Context: 28.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 21.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 1.4Grade Unit: g/tIntercept: 10 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.4
- Grade Unit
- g/t
- Intercept
- 10 m
- True Width
- 7.7 m
- From
- 397 m
- To
- 407 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:397-407
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.40”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.3Grade Unit: g/tIntercept: 36.05 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 36.05 m
- True Width
- 27.9 m
- From
- 420 m
- To
- 456.05 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:420-456.05
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.30”
Context: 36.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 27.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-436Moss · goldGrade: 0.48Grade Unit: g/tIntercept: 22.9 mView all detailsHide details
Identity
- Hole ID
- MMD-26-436
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 22.9 m
- True Width
- 17.8 m
- From
- 458.1 m
- To
- 481 m
- Hole Depth
- 489.3 m
- Intercept Depth
- 188.35 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-436:458.1-481
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668223
- Northing
- 5378403
- Elevation
- 440 m
- Azimuth
- 141.1 °
- Dip
- -51.1 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.48”
Context: 22.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 17.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-437Moss · goldGrade: 0.86Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-437
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.3 m
- From
- 124 m
- To
- 126 m
- Hole Depth
- 333 m
- Intercept Depth
- 124 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-437:124-126
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668531
- Northing
- 5378567
- Elevation
- 436 m
- Azimuth
- 129.1 °
- Dip
- -51 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.86”
Context: 2.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-437Moss · goldGrade: 0.36Grade Unit: g/tIntercept: 49 mView all detailsHide details
Identity
- Hole ID
- MMD-26-437
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 49 m
- True Width
- 32.7 m
- From
- 188 m
- To
- 237 m
- Hole Depth
- 333 m
- Intercept Depth
- 124 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-437:188-237
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668531
- Northing
- 5378567
- Elevation
- 436 m
- Azimuth
- 129.1 °
- Dip
- -51 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, weak-grade gold intercept from infill drilling.
Positive factors
- wide_intercept
- true_width_disclosed
Evidence · table
“0.36”
Context: 49.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 32.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-437Moss · goldGrade: 1.03Grade Unit: g/tIntercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- MMD-26-437
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.03
- Grade Unit
- g/t
- Intercept
- 12.2 m
- True Width
- 8.2 m
- From
- 255 m
- To
- 267.2 m
- Hole Depth
- 333 m
- Intercept Depth
- 124 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-437:255-267.2
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668531
- Northing
- 5378567
- Elevation
- 436 m
- Azimuth
- 129.1 °
- Dip
- -51 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.03”
Context: 12.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-437Moss · goldGrade: 1.15Grade Unit: g/tIntercept: 9.55 mView all detailsHide details
Identity
- Hole ID
- MMD-26-437
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.15
- Grade Unit
- g/t
- Intercept
- 9.55 m
- True Width
- 6.5 m
- From
- 257 m
- To
- 266.55 m
- Hole Depth
- 333 m
- Intercept Depth
- 124 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-437:257-266.55
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668531
- Northing
- 5378567
- Elevation
- 436 m
- Azimuth
- 129.1 °
- Dip
- -51 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.15”
Context: 9.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-438Moss · goldGrade: 0.43Grade Unit: g/tIntercept: 5.85 mView all detailsHide details
Identity
- Hole ID
- MMD-26-438
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 5.85 m
- True Width
- 4 m
- From
- 132.6 m
- To
- 138.45 m
- Hole Depth
- 288 m
- Intercept Depth
- 132.6 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-438:132.6-138.45
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668297
- Northing
- 5378299
- Elevation
- 453 m
- Azimuth
- 120 °
- Dip
- -48.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Weak-grade gold intercept from infill drilling.
Positive factors
- true_width_disclosed
Evidence · table
“0.43”
Context: 5.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-438Moss · goldGrade: 0.78Grade Unit: g/tIntercept: 33.25 mView all detailsHide details
Identity
- Hole ID
- MMD-26-438
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 0.78
- Grade Unit
- g/t
- Intercept
- 33.25 m
- True Width
- 23.4 m
- From
- 195.75 m
- To
- 229 m
- Hole Depth
- 288 m
- Intercept Depth
- 132.6 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-438:195.75-229
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668297
- Northing
- 5378299
- Elevation
- 453 m
- Azimuth
- 120 °
- Dip
- -48.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Wide, moderate-grade gold intercept from infill drilling, contributing to positive resource reconciliation.
Positive factors
- wide_intercept
- moderate_grade
- true_width_disclosed
Evidence · table
“0.78”
Context: 33.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 23.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
MMD-26-438Moss · goldGrade: 1.47Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- MMD-26-438
- Project
- Moss
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- AUXX.V
Geometry
- Grade
- 1.47
- Grade Unit
- g/t
- Intercept
- 14 m
- True Width
- 9.9 m
- From
- 208 m
- To
- 222 m
- Hole Depth
- 288 m
- Intercept Depth
- 132.6 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- MMD-26-438:208-222
- Mining Method
- open_pit
Location
- Location
- Main Zone
- Easting
- 668297
- Northing
- 5378299
- Elevation
- 453 m
- Azimuth
- 120 °
- Dip
- -48.9 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Paragon Geochemical and Activation Laboratories
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-14T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from infill drilling.
Positive factors
- moderate_grade
- true_width_disclosed
Evidence · table
“1.47”
Context: 14.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.