G11: Beatrice Prospect now part of summer drill program

Original announcement by asx on

Company
G11 Resources Limited
Ticker
G11
Exchange
ASX
Region
Tasmania
Primary commodity
Gold
Secondary commodities
Silver, Copper, Lead, Zinc
Document categories
Other, Drill results
Extracted
2026-10-15 23:15:30 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

G11 Resources Limited announced a planned five-hole diamond drill program at its Beatrice Prospect in Tasmania, targeting polymetallic mineralization. The program is justified by historical drilling, including an intercept of 5.5m at 2.13 g/t Au, 28 g/t Ag, 0.21% Cu, 2.13% Pb, and 2.08% Zn from 58m in drillhole MS11. However, the company cautions that these historical results are not JORC 2012 compliant and have not been independently verified.

Reasoning: G11 Resources announced a planned drill program at the Beatrice Prospect, justified by historical polymetallic drill intercepts, but the data is old and not compliant with modern reporting standards, leading to low confidence in the results.

Positive factors

  • Planned drill program
  • Polymetallic target
  • Historical high-grade intercept (MS11)
  • Proximity to known deposits

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • Lack of modern QA/QC records for historical drilling

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 95

Extracted facts

Stored fact records: 95. Some facts used in scoring do not have a stored record.

Drill Results (95)

MS1Sedgewick Bluff · silverGrade: 1Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1
Grade Unit
g/t
Intercept
2 m
From
38 m
To
40 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:38-40
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 1.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · leadGrade: 0.07Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.07
Grade Unit
%
Intercept
2 m
From
38 m
To
40 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:38-40
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.07% over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.07”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · zincGrade: 1.5Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.5
Grade Unit
%
Intercept
2 m
From
38 m
To
40 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:38-40
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 1.5% over 2.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.50”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · silverGrade: 4Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
4
Grade Unit
g/t
Intercept
2 m
From
54 m
To
56 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:54-56
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 4.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“4.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · copperGrade: 0.02Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
54 m
To
56 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:54-56
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.02% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · leadGrade: 1.5Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.5
Grade Unit
%
Intercept
2 m
From
54 m
To
56 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:54-56
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 1.5% over 2.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.50”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · zincGrade: 0.24Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.24
Grade Unit
%
Intercept
2 m
From
54 m
To
56 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:54-56
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.24% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.24”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · goldGrade: 0.28Grade Unit: g/tIntercept: 8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.28
Grade Unit
g/t
Intercept
8 m
From
60 m
To
68 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:60-68
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.28 g/t over 8.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.28”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · silverGrade: 5.2Grade Unit: g/tIntercept: 8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
5.2
Grade Unit
g/t
Intercept
8 m
From
60 m
To
68 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:60-68
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 5.2 g/t over 8.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“5.2”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
8 m
From
60 m
To
68 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:60-68
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 8.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · leadGrade: 0.94Grade Unit: %Intercept: 8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.94
Grade Unit
%
Intercept
8 m
From
60 m
To
68 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:60-68
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.94% over 8.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.94”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · zincGrade: 1.61Grade Unit: %Intercept: 8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.61
Grade Unit
%
Intercept
8 m
From
60 m
To
68 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:60-68
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 1.61% over 8.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.61”

Context: 8.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · goldGrade: 0.2Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
2 m
From
111 m
To
113 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:111-113
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.20 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.20”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · silverGrade: 22Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
22
Grade Unit
g/t
Intercept
2 m
From
111 m
To
113 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:111-113
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 22.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“22.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · copperGrade: 0.14Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.14
Grade Unit
%
Intercept
2 m
From
111 m
To
113 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:111-113
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.14% over 2.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.14”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · leadGrade: 2.65Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
2.65
Grade Unit
%
Intercept
2 m
From
111 m
To
113 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:111-113
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 2.65% over 2.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“2.65”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS1Sedgewick Bluff · zincGrade: 5.05Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS1
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
5.05
Grade Unit
%
Intercept
2 m
From
111 m
To
113 m
Hole Depth
329.1 m
Intercept Depth
38 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS1:111-113
Mining Method
underground

Location

Easting
385602
Northing
5347844
Elevation
755 m
Azimuth
304 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 5.05% over 2.0m is moderate grade for VMS but lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“5.05”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · silverGrade: 8.5Grade Unit: g/tIntercept: 3.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
8.5
Grade Unit
g/t
Intercept
3.9 m
From
60 m
To
63.9 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:60-63.9
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 8.5 g/t over 3.9m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“8.5”

Context: 3.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 3.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
3.9 m
From
60 m
To
63.9 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:60-63.9
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 3.9m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 3.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · leadGrade: 0.59Grade Unit: %Intercept: 3.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.59
Grade Unit
%
Intercept
3.9 m
From
60 m
To
63.9 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:60-63.9
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.59% over 3.9m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.59”

Context: 3.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · zincGrade: 0.78Grade Unit: %Intercept: 3.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.78
Grade Unit
%
Intercept
3.9 m
From
60 m
To
63.9 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:60-63.9
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.78% over 3.9m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.78”

Context: 3.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · silverGrade: 7Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
7
Grade Unit
g/t
Intercept
2 m
From
72 m
To
74 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:72-74
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 7.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“7.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
2 m
From
72 m
To
74 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:72-74
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · leadGrade: 0.38Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.38
Grade Unit
%
Intercept
2 m
From
72 m
To
74 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:72-74
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.38% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.38”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · zincGrade: 0.77Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.77
Grade Unit
%
Intercept
2 m
From
72 m
To
74 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:72-74
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.77% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.77”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · silverGrade: 6Grade Unit: g/tIntercept: 1.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.2 m
From
78 m
To
79.2 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:78-79.2
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 6.0 g/t over 1.2m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“6.0”

Context: 1.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · leadGrade: 0.52Grade Unit: %Intercept: 1.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.52
Grade Unit
%
Intercept
1.2 m
From
78 m
To
79.2 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:78-79.2
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.52% over 1.2m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.52”

Context: 1.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS2Sedgewick Bluff · zincGrade: 0.8Grade Unit: %Intercept: 1.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS2
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.8
Grade Unit
%
Intercept
1.2 m
From
78 m
To
79.2 m
Hole Depth
301 m
Intercept Depth
60 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS2:78-79.2
Mining Method
underground

Location

Easting
385362
Northing
5347624
Elevation
655 m
Azimuth
65 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.80% over 1.2m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.80”

Context: 1.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · goldGrade: 0.07Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
2 m
From
111.6 m
To
113.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:111.6-113.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.07 g/t over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.07”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · silverGrade: 6.5Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
6.5
Grade Unit
g/t
Intercept
2 m
From
111.6 m
To
113.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:111.6-113.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 6.5 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“6.5”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · copperGrade: 0.04Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.04
Grade Unit
%
Intercept
2 m
From
111.6 m
To
113.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:111.6-113.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.04% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.04”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · leadGrade: 0.63Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.63
Grade Unit
%
Intercept
2 m
From
111.6 m
To
113.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:111.6-113.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.63% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.63”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · zincGrade: 1.14Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.14
Grade Unit
%
Intercept
2 m
From
111.6 m
To
113.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:111.6-113.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 1.14% over 2.0m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.14”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · goldGrade: 0.1Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
2 m
From
116.6 m
To
118.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:116.6-118.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.10 g/t over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.10”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · silverGrade: 4Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
4
Grade Unit
g/t
Intercept
2 m
From
116.6 m
To
118.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:116.6-118.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 4.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“4.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
2 m
From
116.6 m
To
118.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:116.6-118.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · leadGrade: 0.55Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.55
Grade Unit
%
Intercept
2 m
From
116.6 m
To
118.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:116.6-118.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.55% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.55”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · zincGrade: 0.48Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.48
Grade Unit
%
Intercept
2 m
From
116.6 m
To
118.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:116.6-118.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.48% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.48”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · silverGrade: 8Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
8
Grade Unit
g/t
Intercept
2 m
From
126.6 m
To
128.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:126.6-128.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 8.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“8.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · copperGrade: 0.02Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
126.6 m
To
128.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:126.6-128.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.02% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · leadGrade: 0.35Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.35
Grade Unit
%
Intercept
2 m
From
126.6 m
To
128.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:126.6-128.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.35% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.35”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · zincGrade: 0.7Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.7
Grade Unit
%
Intercept
2 m
From
126.6 m
To
128.6 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:126.6-128.6
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.70% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.70”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · silverGrade: 4.2Grade Unit: g/tIntercept: 12 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
12 m
From
134 m
To
146 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:134-146
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 4.2 g/t over 12.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“4.2”

Context: 12.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 12 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
12 m
From
134 m
To
146 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:134-146
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 12.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 12.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · leadGrade: 0.47Grade Unit: %Intercept: 12 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.47
Grade Unit
%
Intercept
12 m
From
134 m
To
146 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:134-146
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.47% over 12.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.47”

Context: 12.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · zincGrade: 0.67Grade Unit: %Intercept: 12 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.67
Grade Unit
%
Intercept
12 m
From
134 m
To
146 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:134-146
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.67% over 12.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.67”

Context: 12.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · silverGrade: 3.5Grade Unit: g/tIntercept: 10 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
3.5
Grade Unit
g/t
Intercept
10 m
From
175 m
To
185 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:175-185
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 3.5 g/t over 10.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“3.5”

Context: 10.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 10 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
10 m
From
175 m
To
185 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:175-185
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 10.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 10.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · leadGrade: 0.41Grade Unit: %Intercept: 10 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.41
Grade Unit
%
Intercept
10 m
From
175 m
To
185 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:175-185
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.41% over 10.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.41”

Context: 10.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS3Sedgewick Bluff · zincGrade: 0.72Grade Unit: %Intercept: 10 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS3
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.72
Grade Unit
%
Intercept
10 m
From
175 m
To
185 m
Hole Depth
328 m
Intercept Depth
111.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS3:175-185
Mining Method
underground

Location

Easting
385432
Northing
5347734
Elevation
675 m
Azimuth
60 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.72% over 10.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.72”

Context: 10.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · silverGrade: 3Grade Unit: g/tIntercept: 2.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
3
Grade Unit
g/t
Intercept
2.8 m
From
26 m
To
28.8 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:26-28.8
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 3.0 g/t over 2.8m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“3.0”

Context: 2.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 2.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
2.8 m
From
26 m
To
28.8 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:26-28.8
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 2.8m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 2.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · leadGrade: 0.27Grade Unit: %Intercept: 2.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.27
Grade Unit
%
Intercept
2.8 m
From
26 m
To
28.8 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:26-28.8
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.27% over 2.8m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.27”

Context: 2.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · zincGrade: 0.95Grade Unit: %Intercept: 2.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.95
Grade Unit
%
Intercept
2.8 m
From
26 m
To
28.8 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:26-28.8
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.95% over 2.8m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.95”

Context: 2.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · silverGrade: 2Grade Unit: g/tIntercept: 1.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.7 m
From
116 m
To
117.7 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:116-117.7
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 2.0 g/t over 1.7m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“2.0”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · copperGrade: 0.02Grade Unit: %Intercept: 1.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
1.7 m
From
116 m
To
117.7 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:116-117.7
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.02% over 1.7m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · leadGrade: 0.13Grade Unit: %Intercept: 1.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.13
Grade Unit
%
Intercept
1.7 m
From
116 m
To
117.7 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:116-117.7
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.13% over 1.7m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.13”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · zincGrade: 1.65Grade Unit: %Intercept: 1.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.65
Grade Unit
%
Intercept
1.7 m
From
116 m
To
117.7 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:116-117.7
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 1.65% over 1.7m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.65”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · silverGrade: 3Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
3
Grade Unit
g/t
Intercept
2 m
From
144 m
To
146 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:144-146
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 3.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“3.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · copperGrade: 0.03Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.03
Grade Unit
%
Intercept
2 m
From
144 m
To
146 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:144-146
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.03% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.03”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · leadGrade: 0.16Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.16
Grade Unit
%
Intercept
2 m
From
144 m
To
146 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:144-146
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.16% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.16”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · zincGrade: 0.9Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.9
Grade Unit
%
Intercept
2 m
From
144 m
To
146 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:144-146
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.90% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.90”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · silverGrade: 3Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
3
Grade Unit
g/t
Intercept
2 m
From
148 m
To
150 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:148-150
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 3.0 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“3.0”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
2 m
From
148 m
To
150 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:148-150
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · leadGrade: 0.38Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.38
Grade Unit
%
Intercept
2 m
From
148 m
To
150 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:148-150
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.38% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.38”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS4Sedgewick Bluff · zincGrade: 0.78Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS4
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.78
Grade Unit
%
Intercept
2 m
From
148 m
To
150 m
Hole Depth
350 m
Intercept Depth
26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS4:148-150
Mining Method
underground

Location

Easting
385642
Northing
5348004
Elevation
795 m
Azimuth
306 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1980-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.78% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.78”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS7Sedgewick Bluff · goldGrade: 0.6Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS7
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
2 m
From
388 m
To
390 m
Hole Depth
550 m
Intercept Depth
388 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS7:388-390
Mining Method
underground

Location

Easting
385200
Northing
5347693
Elevation
706 m
Azimuth
60 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.60 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.60”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS7Sedgewick Bluff · silverGrade: 0.4Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS7
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
2 m
From
388 m
To
390 m
Hole Depth
550 m
Intercept Depth
388 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS7:388-390
Mining Method
underground

Location

Easting
385200
Northing
5347693
Elevation
706 m
Azimuth
60 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 0.4 g/t over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.4”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS7Sedgewick Bluff · leadGrade: 0.02Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS7
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
388 m
To
390 m
Hole Depth
550 m
Intercept Depth
388 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS7:388-390
Mining Method
underground

Location

Easting
385200
Northing
5347693
Elevation
706 m
Azimuth
60 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.02% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS7Sedgewick Bluff · zincGrade: 0.02Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS7
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
388 m
To
390 m
Hole Depth
550 m
Intercept Depth
388 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS7:388-390
Mining Method
underground

Location

Easting
385200
Northing
5347693
Elevation
706 m
Azimuth
60 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.02% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 18.4Grade Unit: g/tIntercept: 7.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
18.4
Grade Unit
g/t
Intercept
7.1 m
From
561.9 m
To
569 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:561.9-569
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 18.4 g/t over 7.1m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“18.4”

Context: 7.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 7.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
7.1 m
From
561.9 m
To
569 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:561.9-569
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 7.1m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 7.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.42Grade Unit: %Intercept: 7.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.42
Grade Unit
%
Intercept
7.1 m
From
561.9 m
To
569 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:561.9-569
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.42% over 7.1m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.42”

Context: 7.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 0.98Grade Unit: %Intercept: 7.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.98
Grade Unit
%
Intercept
7.1 m
From
561.9 m
To
569 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:561.9-569
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.98% over 7.1m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.98”

Context: 7.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 11.6Grade Unit: g/tIntercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
11.6
Grade Unit
g/t
Intercept
10.9 m
From
572.5 m
To
583.4 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:572.5-583.4
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 11.6 g/t over 10.9m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“11.6”

Context: 10.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.01Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.01
Grade Unit
%
Intercept
10.9 m
From
572.5 m
To
583.4 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:572.5-583.4
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.01% over 10.9m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.01”

Context: 10.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.5Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.5
Grade Unit
%
Intercept
10.9 m
From
572.5 m
To
583.4 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:572.5-583.4
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.50% over 10.9m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.50”

Context: 10.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 0.98Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.98
Grade Unit
%
Intercept
10.9 m
From
572.5 m
To
583.4 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:572.5-583.4
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.98% over 10.9m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.98”

Context: 10.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 6.7Grade Unit: g/tIntercept: 2.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
6.7
Grade Unit
g/t
Intercept
2.4 m
From
653.2 m
To
655.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:653.2-655.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 6.7 g/t over 2.4m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“6.7”

Context: 2.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.03Grade Unit: %Intercept: 2.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.03
Grade Unit
%
Intercept
2.4 m
From
653.2 m
To
655.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:653.2-655.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.03% over 2.4m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.03”

Context: 2.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.33Grade Unit: %Intercept: 2.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.33
Grade Unit
%
Intercept
2.4 m
From
653.2 m
To
655.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:653.2-655.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.33% over 2.4m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.33”

Context: 2.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 0.97Grade Unit: %Intercept: 2.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.97
Grade Unit
%
Intercept
2.4 m
From
653.2 m
To
655.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:653.2-655.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.97% over 2.4m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.97”

Context: 2.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 6Grade Unit: g/tIntercept: 1.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.1 m
From
696.5 m
To
697.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:696.5-697.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 6.0 g/t over 1.1m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“6.0”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.03Grade Unit: %Intercept: 1.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.03
Grade Unit
%
Intercept
1.1 m
From
696.5 m
To
697.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:696.5-697.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.03% over 1.1m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.03”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.26Grade Unit: %Intercept: 1.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.26
Grade Unit
%
Intercept
1.1 m
From
696.5 m
To
697.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:696.5-697.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.26% over 1.1m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.26”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 0.91Grade Unit: %Intercept: 1.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.91
Grade Unit
%
Intercept
1.1 m
From
696.5 m
To
697.6 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:696.5-697.6
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.91% over 1.1m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.91”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 5.5Grade Unit: g/tIntercept: 1.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
1.3 m
From
735.2 m
To
736.5 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:735.2-736.5
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 5.5 g/t over 1.3m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“5.5”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.04Grade Unit: %Intercept: 1.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.04
Grade Unit
%
Intercept
1.3 m
From
735.2 m
To
736.5 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:735.2-736.5
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.04% over 1.3m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.04”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.29Grade Unit: %Intercept: 1.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.29
Grade Unit
%
Intercept
1.3 m
From
735.2 m
To
736.5 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:735.2-736.5
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.29% over 1.3m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.29”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 1.4Grade Unit: %Intercept: 1.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
1.4
Grade Unit
%
Intercept
1.3 m
From
735.2 m
To
736.5 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:735.2-736.5
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 1.40% over 1.3m is low grade for VMS and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“1.40”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · silverGrade: 7.7Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
silver
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
7.7
Grade Unit
g/t
Intercept
2 m
From
772.8 m
To
774.8 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:772.8-774.8
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical silver intercept of 7.7 g/t over 2.0m is low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“7.7”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · copperGrade: 0.02Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
copper
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
772.8 m
To
774.8 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:772.8-774.8
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical copper intercept of 0.02% over 2.0m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.02”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · leadGrade: 0.3Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
lead
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.3
Grade Unit
%
Intercept
2 m
From
772.8 m
To
774.8 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:772.8-774.8
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical lead intercept of 0.30% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.30”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · zincGrade: 0.84Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
zinc
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.84
Grade Unit
%
Intercept
2 m
From
772.8 m
To
774.8 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:772.8-774.8
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
% Pb+Zn
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical zinc intercept of 0.84% over 2.0m is below cutoff and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.84”

Context: 2.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

MS8Sedgewick Bluff · goldGrade: 0.11Grade Unit: g/tIntercept: 2.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
MS8
Project
Sedgewick Bluff
Commodity
gold
Region
australia_tas
Reported Region
australia_tas
Ticker
G11

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
2.7 m
From
779.7 m
To
782.4 m
Hole Depth
798.7 m
Intercept Depth
561.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
MS8:779.7-782.4
Mining Method
underground

Location

Easting
385222
Northing
5348443
Elevation
955 m
Azimuth
112 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
No
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t Au
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
low_confidence
Historical
Yes
Historical Source Date
1998-12-31T00:00:00.000Z

Dates

Event date
2026-10-15T00:00:00.000Z

Reasoning: Historical gold intercept of 0.11 g/t over 2.7m is very low grade and lacks modern verification.

Negative factors

  • Historical data not JORC 2012 compliant
  • Not independently verified
  • True width unknown
  • No QA/QC disclosure for historical drilling

Evidence · table

“0.11”

Context: 2.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.