CORE SILVER COMMENCES DIAMOND DRILLING AT THE TOULEARY PROJECT
Original announcement by cse on
- Company
- Core Silver Corp.
- Ticker
- CC
- Exchange
- CSE
- Region
- Yukon Territory
- Primary commodity
- Copper
- Secondary commodities
- Gold, Zinc, Silver
- Document categories
- Drill results
- Extracted
- 2026-10-01 01:45:14 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Core Silver Corp. has commenced a 3,000-meter diamond drilling program at its Touleary Project in Yukon Territory, marking the first drilling since 2011. The program will initially focus on the Discovery Zone, following up on strong historical polymetallic VMS intercepts from 2011, and will also test new targets with no prior drilling. The company notes significant untested strike length and VMS potential, but no new assay results are reported in this announcement.
Reasoning: Core Silver Corp. has commenced a diamond drilling program at the Touleary Project, highlighting strong historical polymetallic VMS intercepts and identifying significant untested strike length and new targets, but no new results are presented in this release and true widths are not determined for the historical data.
Positive factors
- Drill program commenced
- Strong historical polymetallic intercepts
- Untested strike length and new targets identified
- VMS potential
- QP signed off on historical data
Negative factors
- No new drill results reported in this release
- Historical results only
- True width not determined for historical intercepts
- Northern Access Route still under construction
Facts used in scoring: 24
Classification and evidence
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The document explicitly states that 'Reported intervals represent drill-core lengths. True widths of the mineralized intervals have not yet been determined.'
Evidence · text
“Reported intervals represent drill-core lengths. True widths of the mineralized intervals have not yet been determined.”
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: All highlighted drill results are from the 2011 drilling campaign, making them historical data re-released in the context of a new program.
Evidence · text
“results from the 2011 drilling campaign”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Nicholas Rodway, P.Geo, a qualified person, has supervised the preparation, verified and approved the technical content, including reviewing historical assessment reports and laboratory certificates.
Evidence · text
“Nicholas Rodway, P.Geo, (Licence No. 46541) (Permit to Practice No. 1000359) is President, CEO and Director of Core Silver, and qualified person as defined by National Instrument 43-101- Standards of Disclosure for Mineral Projects. Mr. Rodway has supervised the preparation, verified and approved the technical content in this release on behalf of both Arcus and Core. Verification included reviewing historical assessment reports and laboratory certificates. No limitations were noted during the verification process.”
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: The document emphasizes 'Proximity to improving regional infrastructure, including the proposed Northern Access Route' and positions the project adjacent to the Finlayson District, suggesting value based on location rather than solely on current results.
Evidence · text
“Proximity to improving regional infrastructure, including the proposed Northern Access Route.”
Exploration Drillingneutral · Story-specific tag
No canonical definition is currently available.
Why it applies: The 2026 program is designed to follow up historical intersections and test compelling undrilled targets elsewhere on the Project, indicating an exploration focus.
Evidence · text
“The program is designed to follow up the significant copper-gold-zinc-silver intersections encountered by historical drilling while also providing flexibility to test compelling undrilled targets elsewhere on the Project.”
Extracted facts
Stored fact records: 24. Some facts used in scoring do not have a stored record.
Drill Results (24)
TL-11-005Touleary · copperGrade: 7.18Grade Unit: %Intercept: 2.25 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 7.18
- Grade Unit
- %
- Intercept
- 2.25 m
- From
- 115.62 m
- To
- 117.87 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:115.62-117.87
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows an exceptional copper grade and strong gold grade, along with moderate silver, for a VMS deposit, indicating high-grade mineralization, though it is an old result with undetermined true width.
Positive factors
- Exceptional copper grade for VMS deposit type
- Strong gold grade
- Moderate silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
Evidence · text
“2.25m @ 7.18% Cu, 3.55g/t Au, 4.30% Zn, 116g/t Ag (115.62 – 117.87m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · goldGrade: 3.55Grade Unit: g/tIntercept: 2.25 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 3.55
- Grade Unit
- g/t
- Intercept
- 2.25 m
- From
- 115.62 m
- To
- 117.87 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:115.62-117.87
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong gold grade, along with exceptional copper and moderate silver, for a VMS deposit, indicating high-grade polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Strong gold grade for VMS deposit type
- Exceptional copper grade
- Moderate silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
Evidence · text
“2.25m @ 7.18% Cu, 3.55g/t Au, 4.30% Zn, 116g/t Ag (115.62 – 117.87m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · zincGrade: 4.3Grade Unit: %Intercept: 2.25 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 4.3
- Grade Unit
- %
- Intercept
- 2.25 m
- From
- 115.62 m
- To
- 117.87 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:115.62-117.87
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak zinc grade, alongside exceptional copper, strong gold, and moderate silver, for a VMS deposit, indicating polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Weak zinc grade for VMS deposit type
- Exceptional copper grade
- Strong gold grade
- Moderate silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
Evidence · text
“2.25m @ 7.18% Cu, 3.55g/t Au, 4.30% Zn, 116g/t Ag (115.62 – 117.87m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · silverGrade: 116Grade Unit: g/tIntercept: 2.25 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 116
- Grade Unit
- g/t
- Intercept
- 2.25 m
- From
- 115.62 m
- To
- 117.87 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:115.62-117.87
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a moderate silver grade, along with exceptional copper and strong gold, for a VMS deposit, indicating high-grade polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Moderate silver grade for VMS deposit type
- Exceptional copper grade
- Strong gold grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
Evidence · text
“2.25m @ 7.18% Cu, 3.55g/t Au, 4.30% Zn, 116g/t Ag (115.62 – 117.87m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · copperGrade: 1.45Grade Unit: %Intercept: 14.15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 1.45
- Grade Unit
- %
- Intercept
- 14.15 m
- From
- 124.5 m
- To
- 138.65 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:124.5-138.65
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong copper grade over a significant length for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Strong copper grade for VMS deposit type
- Significant intercept length
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Weak gold grade
- Below weak zinc grade
- Below weak silver grade
Evidence · text
“14.15m @ 1.45% Cu, 0.73g/t Au, 0.28% Zn, 16.5g/t Ag (124.5 – 138.65m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · goldGrade: 0.73Grade Unit: g/tIntercept: 14.15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 0.73
- Grade Unit
- g/t
- Intercept
- 14.15 m
- From
- 124.5 m
- To
- 138.65 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:124.5-138.65
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak gold grade over a significant length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Significant intercept length
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Weak gold grade for VMS deposit type
- Below weak zinc grade
- Below weak silver grade
Evidence · text
“14.15m @ 1.45% Cu, 0.73g/t Au, 0.28% Zn, 16.5g/t Ag (124.5 – 138.65m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · zincGrade: 0.28Grade Unit: %Intercept: 14.15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 14.15 m
- From
- 124.5 m
- To
- 138.65 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:124.5-138.65
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak zinc grade over a significant length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Significant intercept length
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade for VMS deposit type
- Weak gold grade
- Below weak silver grade
Evidence · text
“14.15m @ 1.45% Cu, 0.73g/t Au, 0.28% Zn, 16.5g/t Ag (124.5 – 138.65m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-005Touleary · silverGrade: 16.5Grade Unit: g/tIntercept: 14.15 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-005
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 16.5
- Grade Unit
- g/t
- Intercept
- 14.15 m
- From
- 124.5 m
- To
- 138.65 m
- Intercept Depth
- 115.62 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-005:124.5-138.65
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak silver grade over a significant length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Significant intercept length
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak silver grade for VMS deposit type
- Weak gold grade
- Below weak zinc grade
Evidence · text
“14.15m @ 1.45% Cu, 0.73g/t Au, 0.28% Zn, 16.5g/t Ag (124.5 – 138.65m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-002Touleary · copperGrade: 2.38Grade Unit: %Intercept: 3.17 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-002
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 2.38
- Grade Unit
- %
- Intercept
- 3.17 m
- From
- 124 m
- To
- 127.17 m
- Intercept Depth
- 124 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-002:124-127.17
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong copper grade and strong gold grade, along with weak silver, for a VMS deposit, indicating good polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Strong copper grade for VMS deposit type
- Strong gold grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade
Evidence · text
“3.17m @ 2.38% Cu, 2.01g/t Au, 1.38% Zn, 32.9g/t Ag (124 - 127.17m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-002Touleary · goldGrade: 2.01Grade Unit: g/tIntercept: 3.17 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-002
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 2.01
- Grade Unit
- g/t
- Intercept
- 3.17 m
- From
- 124 m
- To
- 127.17 m
- Intercept Depth
- 124 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-002:124-127.17
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong gold grade and strong copper grade, along with weak silver, for a VMS deposit, indicating good polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Strong gold grade for VMS deposit type
- Strong copper grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade
Evidence · text
“3.17m @ 2.38% Cu, 2.01g/t Au, 1.38% Zn, 32.9g/t Ag (124 - 127.17m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-002Touleary · zincGrade: 1.38Grade Unit: %Intercept: 3.17 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-002
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 1.38
- Grade Unit
- %
- Intercept
- 3.17 m
- From
- 124 m
- To
- 127.17 m
- Intercept Depth
- 124 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-002:124-127.17
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak zinc grade, alongside strong copper, strong gold, and weak silver, for a VMS deposit, indicating polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Strong copper grade
- Strong gold grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade for VMS deposit type
Evidence · text
“3.17m @ 2.38% Cu, 2.01g/t Au, 1.38% Zn, 32.9g/t Ag (124 - 127.17m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-002Touleary · silverGrade: 32.9Grade Unit: g/tIntercept: 3.17 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-002
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 32.9
- Grade Unit
- g/t
- Intercept
- 3.17 m
- From
- 124 m
- To
- 127.17 m
- Intercept Depth
- 124 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-002:124-127.17
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak silver grade, alongside strong copper and strong gold, for a VMS deposit, indicating polymetallic mineralization, though it is an old result with undetermined true width.
Positive factors
- Weak silver grade for VMS deposit type
- Strong copper grade
- Strong gold grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade
Evidence · text
“3.17m @ 2.38% Cu, 2.01g/t Au, 1.38% Zn, 32.9g/t Ag (124 - 127.17m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-001Touleary · copperGrade: 1.37Grade Unit: %Intercept: 6.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-001
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 1.37
- Grade Unit
- %
- Intercept
- 6.09 m
- From
- 85.61 m
- To
- 91.7 m
- Intercept Depth
- 85.61 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-001:85.61-91.7
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong copper grade over a moderate length for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Strong copper grade for VMS deposit type
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Weak gold grade
- Below weak zinc grade
- Below weak silver grade
Evidence · text
“6.09m @ 1.37% Cu, 0.80g/t Au, 0.41% Zn, 14.5g/t Ag (85.61 – 91.7m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-001Touleary · goldGrade: 0.8Grade Unit: g/tIntercept: 6.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-001
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 6.09 m
- From
- 85.61 m
- To
- 91.7 m
- Intercept Depth
- 85.61 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-001:85.61-91.7
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak gold grade over a moderate length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Weak gold grade for VMS deposit type
- Below weak zinc grade
- Below weak silver grade
Evidence · text
“6.09m @ 1.37% Cu, 0.80g/t Au, 0.41% Zn, 14.5g/t Ag (85.61 – 91.7m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-001Touleary · zincGrade: 0.41Grade Unit: %Intercept: 6.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-001
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 0.41
- Grade Unit
- %
- Intercept
- 6.09 m
- From
- 85.61 m
- To
- 91.7 m
- Intercept Depth
- 85.61 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-001:85.61-91.7
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak zinc grade over a moderate length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak zinc grade for VMS deposit type
- Weak gold grade
- Below weak silver grade
Evidence · text
“6.09m @ 1.37% Cu, 0.80g/t Au, 0.41% Zn, 14.5g/t Ag (85.61 – 91.7m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-001Touleary · silverGrade: 14.5Grade Unit: g/tIntercept: 6.09 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-001
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 14.5
- Grade Unit
- g/t
- Intercept
- 6.09 m
- From
- 85.61 m
- To
- 91.7 m
- Intercept Depth
- 85.61 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-001:85.61-91.7
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak silver grade over a moderate length, alongside a strong copper grade, for a VMS deposit, though it is an old result with undetermined true width and lower grades for other metals.
Positive factors
- Strong copper grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Below weak silver grade for VMS deposit type
- Weak gold grade
- Below weak zinc grade
Evidence · text
“6.09m @ 1.37% Cu, 0.80g/t Au, 0.41% Zn, 14.5g/t Ag (85.61 – 91.7m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · copperGrade: 1.42Grade Unit: %Intercept: 0.59 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 1.42
- Grade Unit
- %
- Intercept
- 0.59 m
- From
- 64.21 m
- To
- 64.8 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:64.21-64.8
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows strong copper, moderate gold, weak zinc, and weak silver grades, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Strong copper grade for VMS deposit type
- Moderate gold grade
- Weak zinc grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
Evidence · text
“0.59m @ 1.42% Cu, 1.15g/t Au, 2.81% Zn, 36.4g/t Ag (64.21 – 64.80m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · goldGrade: 1.15Grade Unit: g/tIntercept: 0.59 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 1.15
- Grade Unit
- g/t
- Intercept
- 0.59 m
- From
- 64.21 m
- To
- 64.8 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:64.21-64.8
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows moderate gold, strong copper, weak zinc, and weak silver grades, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Moderate gold grade for VMS deposit type
- Strong copper grade
- Weak zinc grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
Evidence · text
“0.59m @ 1.42% Cu, 1.15g/t Au, 2.81% Zn, 36.4g/t Ag (64.21 – 64.80m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · zincGrade: 2.81Grade Unit: %Intercept: 0.59 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 2.81
- Grade Unit
- %
- Intercept
- 0.59 m
- From
- 64.21 m
- To
- 64.8 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:64.21-64.8
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak zinc grade, alongside strong copper, moderate gold, and weak silver grades, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Weak zinc grade for VMS deposit type
- Strong copper grade
- Moderate gold grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
Evidence · text
“0.59m @ 1.42% Cu, 1.15g/t Au, 2.81% Zn, 36.4g/t Ag (64.21 – 64.80m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · silverGrade: 36.4Grade Unit: g/tIntercept: 0.59 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 36.4
- Grade Unit
- g/t
- Intercept
- 0.59 m
- From
- 64.21 m
- To
- 64.8 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:64.21-64.8
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak silver grade, alongside strong copper, moderate gold, and weak zinc grades, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Weak silver grade for VMS deposit type
- Strong copper grade
- Moderate gold grade
- Weak zinc grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
Evidence · text
“0.59m @ 1.42% Cu, 1.15g/t Au, 2.81% Zn, 36.4g/t Ag (64.21 – 64.80m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · copperGrade: 4.01Grade Unit: %Intercept: 0.61 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- copper
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 4.01
- Grade Unit
- %
- Intercept
- 0.61 m
- From
- 90.36 m
- To
- 90.97 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:90.36-90.97
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows an exceptional copper grade and strong gold grade, along with weak silver, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Exceptional copper grade for VMS deposit type
- Strong gold grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
- Below weak zinc grade
Evidence · text
“0.61m @ 4.01% Cu, 2.18g/t Au, 0.93% Zn, 73.9g/t Ag (90.36 – 90.97m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · goldGrade: 2.18Grade Unit: g/tIntercept: 0.61 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- gold
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 2.18
- Grade Unit
- g/t
- Intercept
- 0.61 m
- From
- 90.36 m
- To
- 90.97 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:90.36-90.97
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a strong gold grade and exceptional copper grade, along with weak silver, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Strong gold grade for VMS deposit type
- Exceptional copper grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
- Below weak zinc grade
Evidence · text
“0.61m @ 4.01% Cu, 2.18g/t Au, 0.93% Zn, 73.9g/t Ag (90.36 – 90.97m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · zincGrade: 0.93Grade Unit: %Intercept: 0.61 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- zinc
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 0.93
- Grade Unit
- %
- Intercept
- 0.61 m
- From
- 90.36 m
- To
- 90.97 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:90.36-90.97
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a below-weak zinc grade, alongside exceptional copper, strong gold, and weak silver, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Exceptional copper grade
- Strong gold grade
- Weak silver grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
- Below weak zinc grade for VMS deposit type
Evidence · text
“0.61m @ 4.01% Cu, 2.18g/t Au, 0.93% Zn, 73.9g/t Ag (90.36 – 90.97m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
TL-11-003Touleary · silverGrade: 73.9Grade Unit: g/tIntercept: 0.61 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- TL-11-003
- Project
- Touleary
- Commodity
- silver
- Region
- canada_yt
- Reported Region
- canada_yt
- Ticker
- CC
Geometry
- Grade
- 73.9
- Grade Unit
- g/t
- Intercept
- 0.61 m
- From
- 90.36 m
- To
- 90.97 m
- Intercept Depth
- 64.21 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- TL-11-003:90.36-90.97
QA/QC
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2011-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-09T00:00:00.000Z
Reasoning: This historical intercept shows a weak silver grade, alongside exceptional copper and strong gold, but over a very narrow length, though it is an old result with undetermined true width.
Positive factors
- Weak silver grade for VMS deposit type
- Exceptional copper grade
- Strong gold grade
- QP signed off on historical data
Negative factors
- Historical result only
- Apparent width only
- Narrow intercept length
- Below weak zinc grade
Evidence · text
“0.61m @ 4.01% Cu, 2.18g/t Au, 0.93% Zn, 73.9g/t Ag (90.36 – 90.97m)”
Tags used in scoring
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "• Interpreted potential of the Discovery Zone indicates approximately 3.5 kilometres of untested strike-length."
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.