Collective Mining Discovers High-Grade Tungsten and Gold Mineralization in Schist at Depth Outside the Apollo Breccia Body
Original announcement by orestocks on
- Company
- Collective Mining Ltd.
- Ticker
- CNL
- Exchange
- Unavailable
- Region
- Caldas, Colombia
- Primary commodity
- Tungsten
- Secondary commodities
- Gold, Silver, Copper
- Document categories
- Drill results, Other
- Extracted
- 2026-09-24 11:56:26 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Collective Mining has discovered high-grade tungsten and gold mineralization in schist hosted outside the southern margin of the Apollo breccia body. The results include a significant 8.15m intercept at 14.82 g/t AuEq (containing 0.40% WO3) and the identification of 13 new high-grade veins. This discovery establishes a new exploration target at depth, approximately 680m below the existing shallow tungsten zone.
Reasoning: The discovery of a new high-grade tungsten-gold style in the surrounding schist represents a significant expansion of the project's exploration potential beyond the known Apollo breccia body.
Positive factors
- New high-grade tungsten discovery in schist outside the main breccia body
- Discovery of multiple high-grade veins (13 new veins)
- Significant vertical depth (680m below existing tungsten zone)
- High-grade gold intercepts (up to 55.5 g/t Au)
- Step-out extension of Ramp Zone mineralization
Negative factors
- Challenging drilling conditions caused early termination of some holes
- Assays still pending for 17 holes
Facts used in scoring: 49
Classification and evidence
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: Mineralization extended beyond the current block model for the Ramp Zone and into the surrounding schist.
Evidence · text
“Ramp Zone mineralization extended approximately 35 meters westward from the current block model”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The 1.15m intercept at 55.50 g/t Au is exceptionally high grade.
Evidence · table
“55.50”
Context: 1.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release details assay methods (fire assay, ICP-AES, ICP-MS) and mentions use of blanks, duplicates, and standards.
Evidence · text
“Blanks, duplicates, and certified reference standards are inserted into the sample stream”
Extracted facts
Stored fact records: 49. Some facts used in scoring do not have a stored record.
Drill Results (49)
APC150-D4Apollo · tungstenGrade: 0.4Grade Unit: %Intercept: 8.15 mView all detailsHide details
Identity
- Hole ID
- APC150-D4
- Project
- Apollo
- Commodity
- tungsten
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 8.15 m
- From
- 128.75 m
- To
- 136.9 m
- Intercept Depth
- 128.75 m
Classification
- Sample Type
- drill
- Group ID
- APC150-D4:128.75-136.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: High-grade tungsten intercept in a new geological setting (schist) outside the main breccia.
Positive factors
- First tungsten intersection in surrounding schist
Evidence · table
“0.40”
Context: 8.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC150-D4Apollo · goldGrade: 8.47Grade Unit: g/tIntercept: 8.15 mView all detailsHide details
Identity
- Hole ID
- APC150-D4
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 8.47
- Grade Unit
- g/t
- Intercept
- 8.15 m
- From
- 128.75 m
- To
- 136.9 m
- Intercept Depth
- 128.75 m
Classification
- Sample Type
- drill
- Group ID
- APC150-D4:128.75-136.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Strong gold grade accompanying the new tungsten discovery.
Evidence · table
“8.47”
Context: 8.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC150-D4Apollo · silverGrade: 4Grade Unit: g/tIntercept: 8.15 mView all detailsHide details
Identity
- Hole ID
- APC150-D4
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 4
- Grade Unit
- g/t
- Intercept
- 8.15 m
- From
- 128.75 m
- To
- 136.9 m
- Intercept Depth
- 128.75 m
Classification
- Sample Type
- drill
- Group ID
- APC150-D4:128.75-136.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Silver byproduct in the new tungsten-gold zone.
Evidence · table
“4”
Context: 8.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC150-D4Apollo · goldGrade: 13.55Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- APC150-D4
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 13.55
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 144.9 m
- To
- 145.95 m
- Intercept Depth
- 144.9 m
Classification
- Sample Type
- drill
- Group ID
- APC150-D4:144.9-145.95
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: High-grade gold sub-interval in the new schist zone.
Evidence · table
“13.55”
Context: 1.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 55.5Grade Unit: g/tIntercept: 1.15 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 55.5
- Grade Unit
- g/t
- Intercept
- 1.15 m
- From
- 823.15 m
- To
- 824.3 m
- Intercept Depth
- 823.15 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:823.15-824.3
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Exceptionally high gold grade in a new vein.
Positive factors
- Bonanza grade gold
Evidence · table
“55.50”
Context: 1.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 109Grade Unit: g/tIntercept: 1.15 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 109
- Grade Unit
- g/t
- Intercept
- 1.15 m
- From
- 823.15 m
- To
- 824.3 m
- Intercept Depth
- 823.15 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:823.15-824.3
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: High silver grade in the new high-grade vein.
Evidence · table
“109”
Context: 1.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · copperGrade: 0.35Grade Unit: %Intercept: 1.15 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 1.15 m
- From
- 823.15 m
- To
- 824.3 m
- Intercept Depth
- 823.15 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:823.15-824.3
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Trace copper in the high-grade vein.
Evidence · table
“0.35”
Context: 1.15
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC150-D4Apollo · silverGrade: 2Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- APC150-D4
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 2
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 144.9 m
- To
- 145.95 m
- Intercept Depth
- 144.9 m
Classification
- Sample Type
- drill
- Group ID
- APC150-D4:144.9-145.95
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.1 g/t·m is below.
Negative factors
- 2 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2”
Context: APC150-D4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 7.82Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 7.82
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 311.05 m
- To
- 312.35 m
- Intercept Depth
- 311.05 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:311.05-312.35
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 7.82 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 10.2 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 7.82 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.82”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 6Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 311.05 m
- To
- 312.35 m
- Intercept Depth
- 311.05 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:311.05-312.35
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.8 g/t·m is below.
Negative factors
- 6 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 3Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 3
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 775.55 m
- To
- 776.65 m
- Intercept Depth
- 775.55 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:775.55-776.65
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 3 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 3 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.00”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 163Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 163
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 775.55 m
- To
- 776.65 m
- Intercept Depth
- 775.55 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:775.55-776.65
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 163 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 179.3 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“163”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · copperGrade: 0.6Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 775.55 m
- To
- 776.65 m
- Intercept Depth
- 775.55 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:775.55-776.65
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 0.6 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.7 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.60”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 8.12Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 8.12
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 940.9 m
- To
- 942.1 m
- Intercept Depth
- 940.9 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:940.9-942.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 8.12 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 9.7 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.12 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.12”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 14Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 14
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 940.9 m
- To
- 942.1 m
- Intercept Depth
- 940.9 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:940.9-942.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 14 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.8 g/t·m is below.
Negative factors
- 14 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · copperGrade: 0.04Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 1.2 m
- From
- 940.9 m
- To
- 942.1 m
- Intercept Depth
- 940.9 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:940.9-942.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.04 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 28.6Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 28.6
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 949.65 m
- To
- 950.9 m
- Intercept Depth
- 949.65 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:949.65-950.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 28.6 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 35.8 g/t·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 28.6 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“28.60”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 6Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 949.65 m
- To
- 950.9 m
- Intercept Depth
- 949.65 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:949.65-950.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.5 g/t·m is below.
Negative factors
- 6 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · goldGrade: 5.82Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 5.82
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 990.35 m
- To
- 992.55 m
- Intercept Depth
- 990.35 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:990.35-992.55
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5.82 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 12.8 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.82 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.82”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC-171DApollo · silverGrade: 12Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- APC-171D
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 12
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 990.35 m
- To
- 992.55 m
- Intercept Depth
- 990.35 m
Classification
- Sample Type
- drill
- Group ID
- APC-171D:990.35-992.55
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 12 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 26.4 g/t·m is below.
Negative factors
- 12 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“12”
Context: APC-171D
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 6.23Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6.23
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 130.8 m
- To
- 132 m
- Intercept Depth
- 130.8 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:130.8-132
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6.23 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 7.5 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.23 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.23”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 56Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 56
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 130.8 m
- To
- 132 m
- Intercept Depth
- 130.8 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:130.8-132
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 56 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 67.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“56”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 4.28Grade Unit: g/tIntercept: 9.7 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 4.28
- Grade Unit
- g/t
- Intercept
- 9.7 m
- From
- 145.3 m
- To
- 155 m
- Intercept Depth
- 145.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:145.3-155
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 4.28 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 41.5 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 4.28 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.28”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 11Grade Unit: g/tIntercept: 9.7 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 11
- Grade Unit
- g/t
- Intercept
- 9.7 m
- From
- 145.3 m
- To
- 155 m
- Intercept Depth
- 145.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:145.3-155
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 11 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 106.7 g/t·m is below.
Negative factors
- 11 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“11”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · copperGrade: 0.05Grade Unit: %Intercept: 9.7 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 9.7 m
- From
- 145.3 m
- To
- 155 m
- Intercept Depth
- 145.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:145.3-155
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.5 %·m is below.
Negative factors
- 0.05 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 5.56Grade Unit: g/tIntercept: 5.3 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 5.56
- Grade Unit
- g/t
- Intercept
- 5.3 m
- From
- 43.7 m
- To
- 49 m
- Intercept Depth
- 43.7 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:43.7-49
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5.56 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 29.5 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.56 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.56”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 53Grade Unit: g/tIntercept: 5.3 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 53
- Grade Unit
- g/t
- Intercept
- 5.3 m
- From
- 43.7 m
- To
- 49 m
- Intercept Depth
- 43.7 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:43.7-49
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 53 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 280.9 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“53”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · copperGrade: 0.15Grade Unit: %Intercept: 5.3 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 5.3 m
- From
- 43.7 m
- To
- 49 m
- Intercept Depth
- 43.7 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:43.7-49
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.8 %·m is below.
Negative factors
- 0.15 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 7.37Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 7.37
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 89.9 m
- To
- 90.9 m
- Intercept Depth
- 89.9 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:89.9-90.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 7.37 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 7.4 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 7.37 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.37”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 57Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 57
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 89.9 m
- To
- 90.9 m
- Intercept Depth
- 89.9 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:89.9-90.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 57 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 57.0 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“57”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · copperGrade: 0.16Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- copper
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 1 m
- From
- 89.9 m
- To
- 90.9 m
- Intercept Depth
- 89.9 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:89.9-90.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.16 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 6.14Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6.14
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 181.5 m
- To
- 184.1 m
- Intercept Depth
- 181.5 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:181.5-184.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6.14 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 16.0 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.14 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.14”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 10Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 10
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 181.5 m
- To
- 184.1 m
- Intercept Depth
- 181.5 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:181.5-184.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 10 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 26.0 g/t·m is below.
Negative factors
- 10 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 6.95Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6.95
- Grade Unit
- g/t
- Intercept
- 1.35 m
- From
- 188.85 m
- To
- 190.2 m
- Intercept Depth
- 188.85 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:188.85-190.2
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6.95 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 9.4 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.95 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.95”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 6Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6
- Grade Unit
- g/t
- Intercept
- 1.35 m
- From
- 188.85 m
- To
- 190.2 m
- Intercept Depth
- 188.85 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:188.85-190.2
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.1 g/t·m is below.
Negative factors
- 6 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 8.2Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 8.2
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 299.45 m
- To
- 300.7 m
- Intercept Depth
- 299.45 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:299.45-300.7
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 8.2 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 10.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.2 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.20”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 5Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 5
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 299.45 m
- To
- 300.7 m
- Intercept Depth
- 299.45 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:299.45-300.7
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.3 g/t·m is below.
Negative factors
- 5 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 5.25Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 5.25
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 116 m
- To
- 118.6 m
- Intercept Depth
- 116 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:116-118.6
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5.25 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 13.7 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.25 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.25”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 5Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 5
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 116 m
- To
- 118.6 m
- Intercept Depth
- 116 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:116-118.6
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.0 g/t·m is below.
Negative factors
- 5 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 2.24Grade Unit: g/tIntercept: 13.85 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 2.24
- Grade Unit
- g/t
- Intercept
- 13.85 m
- From
- 188.05 m
- To
- 201.9 m
- Intercept Depth
- 188.05 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:188.05-201.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 2.24 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 31.0 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 2.24 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.24”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 3Grade Unit: g/tIntercept: 13.85 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 3
- Grade Unit
- g/t
- Intercept
- 13.85 m
- From
- 188.05 m
- To
- 201.9 m
- Intercept Depth
- 188.05 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:188.05-201.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 41.5 g/t·m is below.
Negative factors
- 3 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 2.69Grade Unit: g/tIntercept: 8.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 2.69
- Grade Unit
- g/t
- Intercept
- 8.6 m
- From
- 209.3 m
- To
- 217.9 m
- Intercept Depth
- 209.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:209.3-217.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 2.69 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 23.1 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 2.69 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.69”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 1Grade Unit: g/tIntercept: 8.6 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 1
- Grade Unit
- g/t
- Intercept
- 8.6 m
- From
- 209.3 m
- To
- 217.9 m
- Intercept Depth
- 209.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:209.3-217.9
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.6 g/t·m is below.
Negative factors
- 1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · goldGrade: 6.58Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 6.58
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 246 m
- To
- 247 m
- Intercept Depth
- 246 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:246-247
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 6.58 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 6.6 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 6.58 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.58”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D1Apollo · silverGrade: 1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- APC171-D1
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 246 m
- To
- 247 m
- Intercept Depth
- 246 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D1:246-247
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.0 g/t·m is below.
Negative factors
- 1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1”
Context: APC171-D1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 8.97Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 8.97
- Grade Unit
- g/t
- Intercept
- 2.1 m
- From
- 604 m
- To
- 606.1 m
- Intercept Depth
- 604 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:604-606.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 8.97 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 18.8 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 8.97 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.97”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 13Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 13
- Grade Unit
- g/t
- Intercept
- 2.1 m
- From
- 604 m
- To
- 606.1 m
- Intercept Depth
- 604 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:604-606.1
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 13 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 27.3 g/t·m is below.
Negative factors
- 13 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · goldGrade: 2.58Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 2.58
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 616.3 m
- To
- 619.05 m
- Intercept Depth
- 616.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:616.3-619.05
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 2.58 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 7.1 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 2.58 g/t gold is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.58”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
APC171-D2Apollo · silverGrade: 1Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- APC171-D2
- Project
- Apollo
- Commodity
- silver
- Region
- colombia
- Reported Region
- colombia
- Ticker
- CNL
Geometry
- Grade
- 1
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 616.3 m
- To
- 619.05 m
- Intercept Depth
- 616.3 m
Classification
- Sample Type
- drill
- Group ID
- APC171-D2:616.3-619.05
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-24T00:00:00.000Z
Reasoning: Expanded from assay table. 1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.8 g/t·m is below.
Negative factors
- 1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1”
Context: APC171-D2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.