Collective Mining Discovers High-Grade Tungsten and Gold Mineralization in Schist at Depth Outside the Apollo Breccia Body

Original announcement by cnw on

Company
Collective Mining Ltd.
Ticker
CNL
Exchange
Unavailable
Region
Caldas, Colombia
Primary commodity
Gold
Secondary commodities
Tungsten, Silver, Copper
Document categories
Drill results
Extracted
2026-09-24 10:34:45 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Collective Mining announced the discovery of high-grade tungsten and gold mineralization in schist at depth, outside the Apollo breccia body, marking a new exploration target. The company also reported multiple high-grade gold-silver-copper vein intercepts, including 1.15 meters grading 57.98 g/t AuEq, and extended the Ramp Zone mineralization westward. These results highlight significant exploration potential at the Guayabales Project.

Reasoning: The discovery of a new high-grade tungsten-gold zone in schist, combined with numerous high-grade gold intercepts and extensions to known mineralization, represents a significant positive development for the project's exploration potential and resource growth.

Positive factors

  • Discovery of new high-grade tungsten and gold mineralization in schist, opening a new exploration target outside the main breccia body.
  • Multiple high-grade gold intercepts, with several exceeding the 'strong' to 'exceptional' thresholds for orogenic deposits.
  • Extension of the Ramp Zone mineralization westward, indicating continued growth potential.
  • Comprehensive QA/QC procedures disclosed, including certified lab and QP sign-off.
  • Metal equivalent assumptions are transparently disclosed.

Negative factors

  • Intercepts are generally narrow, with true widths estimated to range from 60% to 100% of reported intervals, not explicitly stated for each.
  • Challenging drilling conditions were encountered, terminating some holes short of target depths.
  • Presence of deleterious elements (bismuth, tellurium, arsenopyrite) noted in Ramp Zone mineralization.

Facts used in scoring: 49

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept of 55.50 g/t Au over 1.15 m is exceptionally high-grade, well above the deposit-type norm for orogenic gold deposits.

Evidence · table

“55.50”

Context: 1.15

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept of 28.60 g/t Au over 1.25 m is exceptionally high-grade, well above the deposit-type norm for orogenic gold deposits.

Evidence · table

“28.60”

Context: 1.25

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states 'Ramp Zone mineralization extended approximately 35 meters westward from the current block model for the Ramp Zone along the southern axis of the breccia margin' and 'new high-grade veins have been discovered, including... in APC-171D. Seven veins lie outside the block model'.

Evidence · text

“Ramp Zone mineralization extended approximately 35 meters westward from the current block model for the Ramp Zone along the southern axis of the breccia margin.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release mentions that 'ALS is an accredited laboratory' and 'Blanks, duplicates, and certified reference standards are inserted into the sample stream'.

Evidence · text

“ALS is an accredited laboratory which is independent of the Company. Gold assays are obtained by fire assay fusion with AAS finish on a 50g sample (Au-AA24). Any samples returning > 10 g/t were then reanalyzed by fire assay with gravimetric finish on a 50g sample (Au-GRA22). Copper and silver were assayed by inductively coupled plasma - Atomic Emission Spectroscopy (ICP-AES) and Mass Spectrometry (ICP-MS) following a 4-acid digestion. Samples were also analyzed for a suite of 48 elements with ME-MS61 plus mercury and a sequential copper leach analysis was completed on each sample with copper greater than 10,000 parts per million. Blanks, duplicates, and certified reference standards are inserted into the sample stream to monitor laboratory performance.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: The release states that 'No capping has been applied to sample composites', indicating clear rules for interval reporting.

Evidence · text

“No capping has been applied to sample composites.”

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: The release mentions 'anomalous bismuth and tellurium' and 'minor bismuth, tellurium, and locally arsenopyrite-bearing sulphides' in the Ramp Zone mineralization.

Evidence · text

“anomalous bismuth and tellurium”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document states 'Intervals are down hole lengths. Estimated true widths range from 60% to 100% of reported intervals', but no specific true widths are provided for individual intercepts.

Evidence · text

“Intervals are down hole lengths. Estimated true widths range from 60% to 100% of reported intervals.”

Extracted facts

Stored fact records: 49. Some facts used in scoring do not have a stored record.

Drill Results (49)

APC150-D4Guayabales · goldGrade: 8.47Grade Unit: g/tIntercept: 8.15 mView all details
Link to this fact

Identity

Hole ID
APC150-D4
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
8.47
Grade Unit
g/t
Intercept
8.15 m
From
128.75 m
To
136.9 m
Intercept Depth
128.75 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC150-D4:128.75-136.9
Mining Method
underground

Location

Location
Pad34
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
14.82
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept represents a strong gold grade within a new high-grade tungsten-gold discovery, significantly enhancing the project's exploration potential.

Positive factors

  • High gold grade (8.47 g/t) is strong for an orogenic deposit.
  • Part of a new tungsten-gold discovery in schist, indicating new exploration potential.
  • Metal equivalent grade of 14.82 g/t AuEq is very strong.

Negative factors

  • Intercept width is moderate (8.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“8.47”

Context: 8.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC150-D4Guayabales · silverGrade: 4Grade Unit: g/tIntercept: 8.15 mView all details
Link to this fact

Identity

Hole ID
APC150-D4
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
4
Grade Unit
g/t
Intercept
8.15 m
From
128.75 m
To
136.9 m
Intercept Depth
128.75 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC150-D4:128.75-136.9
Mining Method
underground

Location

Location
Pad34
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
14.82
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: While the silver grade is weak, this intercept is part of a significant new tungsten-gold discovery, contributing to the overall positive outlook.

Positive factors

  • Part of a new tungsten-gold discovery in schist, indicating new exploration potential.
  • Metal equivalent grade of 14.82 g/t AuEq is very strong.

Negative factors

  • Silver grade (4 g/t) is weak.
  • Intercept width is moderate (8.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“4”

Context: 8.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC150-D4Guayabales · tungstenGrade: 0.4Grade Unit: %Intercept: 8.15 mView all details
Link to this fact

Identity

Hole ID
APC150-D4
Project
Guayabales
Commodity
tungsten
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.4
Grade Unit
%
Intercept
8.15 m
From
128.75 m
To
136.9 m
Intercept Depth
128.75 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC150-D4:128.75-136.9
Mining Method
underground

Location

Location
Pad34
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
14.82
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept represents a significant new tungsten discovery in a previously untested geological setting, despite the grade being below default thresholds, its novelty and contribution to the high AuEq grade are highly positive.

Positive factors

  • First tungsten intersection in surrounding schist in this area, representing a new discovery.
  • Metal equivalent grade of 14.82 g/t AuEq is very strong.

Negative factors

  • Tungsten grade (0.40% WO3) is below the 'weak' threshold for default rubric, but its novelty is high.
  • Intercept width is moderate (8.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.40”

Context: 8.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC150-D4Guayabales · goldGrade: 13.55Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
APC150-D4
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
13.55
Grade Unit
g/t
Intercept
1.05 m
From
144.9 m
To
145.95 m
Intercept Depth
144.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC150-D4:144.9-145.95
Mining Method
underground

Location

Location
Pad34
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
13.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade within the new discovery zone, contributing positively despite its narrow width.

Positive factors

  • High gold grade (13.55 g/t) is strong for an orogenic deposit.
  • Part of a new tungsten-gold discovery in schist, indicating new exploration potential.

Negative factors

  • Intercept width is narrow (1.05 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“13.55”

Context: 1.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC150-D4Guayabales · silverGrade: 2Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
APC150-D4
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.05 m
From
144.9 m
To
145.95 m
Intercept Depth
144.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC150-D4:144.9-145.95
Mining Method
underground

Location

Location
Pad34
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
13.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new discovery and contributes to a high AuEq grade.

Positive factors

  • Part of a new tungsten-gold discovery in schist, indicating new exploration potential.
  • Metal equivalent grade of 13.58 g/t AuEq is very strong.

Negative factors

  • Silver grade (2 g/t) is weak.
  • Intercept width is narrow (1.05 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“2”

Context: 1.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 7.82Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
7.82
Grade Unit
g/t
Intercept
1.3 m
From
311.05 m
To
312.35 m
Intercept Depth
311.05 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:311.05-312.35
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.93
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery outside the existing block model, indicating expansion potential.

Positive factors

  • High gold grade (7.82 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.

Negative factors

  • Intercept width is narrow (1.30 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“7.82”

Context: 1.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 6Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.3 m
From
311.05 m
To
312.35 m
Intercept Depth
311.05 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:311.05-312.35
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.93
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery and contributes to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 7.93 g/t AuEq is strong.

Negative factors

  • Silver grade (6 g/t) is weak.
  • Intercept width is narrow (1.30 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6”

Context: 1.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 3Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
3
Grade Unit
g/t
Intercept
1.1 m
From
775.55 m
To
776.65 m
Intercept Depth
775.55 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:775.55-776.65
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade from a new vein discovery outside the existing block model, contributing to the overall expansion potential.

Positive factors

  • Gold grade (3.00 g/t) is above the 'weak' threshold for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 6.81 g/t AuEq is strong.

Negative factors

  • Intercept width is narrow (1.10 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“3.00”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 163Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
163
Grade Unit
g/t
Intercept
1.1 m
From
775.55 m
To
776.65 m
Intercept Depth
775.55 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:775.55-776.65
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade from a new vein discovery outside the existing block model, contributing to the overall expansion potential.

Positive factors

  • High silver grade (163 g/t) is strong.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 6.81 g/t AuEq is strong.

Negative factors

  • Intercept width is narrow (1.10 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“163”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · copperGrade: 0.6Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.6
Grade Unit
%
Intercept
1.1 m
From
775.55 m
To
776.65 m
Intercept Depth
775.55 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:775.55-776.65
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate copper grade from a new vein discovery outside the existing block model, contributing to the overall expansion potential.

Positive factors

  • Copper grade (0.60%) is moderate for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 6.81 g/t AuEq is strong.

Negative factors

  • Intercept width is narrow (1.10 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.60”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 55.5Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
55.5
Grade Unit
g/t
Intercept
1.15 m
From
823.15 m
To
824.3 m
Intercept Depth
823.15 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:823.15-824.3
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
57.98
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept represents an exceptional bonanza gold grade from a new vein discovery, significantly enhancing the project's potential despite its narrow width.

Positive factors

  • Exceptional gold grade (55.50 g/t) is a bonanza intercept for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 57.98 g/t AuEq is exceptional.

Negative factors

  • Intercept width is narrow (1.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“55.50”

Context: 1.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 109Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
109
Grade Unit
g/t
Intercept
1.15 m
From
823.15 m
To
824.3 m
Intercept Depth
823.15 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:823.15-824.3
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
57.98
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade from a new vein discovery, contributing to an exceptional AuEq grade.

Positive factors

  • High silver grade (109 g/t) is moderate.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 57.98 g/t AuEq is exceptional.

Negative factors

  • Intercept width is narrow (1.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“109”

Context: 1.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · copperGrade: 0.35Grade Unit: %Intercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.35
Grade Unit
%
Intercept
1.15 m
From
823.15 m
To
824.3 m
Intercept Depth
823.15 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:823.15-824.3
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
57.98
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The copper grade is weak, but the intercept is part of a new vein discovery and contributes to an exceptional AuEq grade.

Positive factors

  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 57.98 g/t AuEq is exceptional.

Negative factors

  • Copper grade (0.35%) is weak for an orogenic deposit.
  • Intercept width is narrow (1.15 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.35”

Context: 1.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 8.12Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
8.12
Grade Unit
g/t
Intercept
1.2 m
From
940.9 m
To
942.1 m
Intercept Depth
940.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:940.9-942.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery within the existing block model, indicating higher grades than previously estimated.

Positive factors

  • High gold grade (8.12 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model, exceeding estimates.

Negative factors

  • Intercept width is narrow (1.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“8.12”

Context: 1.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 14Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
14
Grade Unit
g/t
Intercept
1.2 m
From
940.9 m
To
942.1 m
Intercept Depth
940.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:940.9-942.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model, exceeding estimates.
  • Metal equivalent grade of 8.43 g/t AuEq is strong.

Negative factors

  • Silver grade (14 g/t) is weak.
  • Intercept width is narrow (1.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“14”

Context: 1.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · copperGrade: 0.04Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.04
Grade Unit
%
Intercept
1.2 m
From
940.9 m
To
942.1 m
Intercept Depth
940.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:940.9-942.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The copper grade is very weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model, exceeding estimates.
  • Metal equivalent grade of 8.43 g/t AuEq is strong.

Negative factors

  • Copper grade (0.04%) is very weak.
  • Intercept width is narrow (1.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.04”

Context: 1.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 28.6Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
28.6
Grade Unit
g/t
Intercept
1.25 m
From
949.65 m
To
950.9 m
Intercept Depth
949.65 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:949.65-950.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
28.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept represents an exceptional bonanza gold grade from a new vein discovery, significantly enhancing the project's potential despite its narrow width.

Positive factors

  • Exceptional gold grade (28.60 g/t) is a bonanza intercept for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model, exceeding estimates.

Negative factors

  • Intercept width is narrow (1.25 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“28.60”

Context: 1.25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 6Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.25 m
From
949.65 m
To
950.9 m
Intercept Depth
949.65 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:949.65-950.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
28.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to an exceptional AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model, exceeding estimates.
  • Metal equivalent grade of 28.73 g/t AuEq is exceptional.

Negative factors

  • Silver grade (6 g/t) is weak.
  • Intercept width is narrow (1.25 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6”

Context: 1.25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · goldGrade: 5.82Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
5.82
Grade Unit
g/t
Intercept
2.2 m
From
990.35 m
To
992.55 m
Intercept Depth
990.35 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:990.35-992.55
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery within the existing block model, contributing positively to the project.

Positive factors

  • High gold grade (5.82 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model.

Negative factors

  • Intercept width is narrow (2.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“5.82”

Context: 2.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC-171DGuayabales · silverGrade: 12Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
APC-171D
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
12
Grade Unit
g/t
Intercept
2.2 m
From
990.35 m
To
992.55 m
Intercept Depth
990.35 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC-171D:990.35-992.55
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model.
  • Metal equivalent grade of 6.05 g/t AuEq is strong.

Negative factors

  • Silver grade (12 g/t) is weak.
  • Intercept width is narrow (2.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“12”

Context: 2.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 6.23Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6.23
Grade Unit
g/t
Intercept
1.2 m
From
130.8 m
To
132 m
Intercept Depth
130.8 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:130.8-132
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery outside the existing block model, indicating expansion potential.

Positive factors

  • High gold grade (6.23 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.

Negative factors

  • Intercept width is narrow (1.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6.23”

Context: 1.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 56Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
56
Grade Unit
g/t
Intercept
1.2 m
From
130.8 m
To
132 m
Intercept Depth
130.8 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:130.8-132
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade from a new vein discovery outside the existing block model, contributing to the overall expansion potential.

Positive factors

  • High silver grade (56 g/t) is strong.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 7.31 g/t AuEq is strong.

Negative factors

  • Intercept width is narrow (1.20 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“56”

Context: 1.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 4.28Grade Unit: g/tIntercept: 9.7 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
4.28
Grade Unit
g/t
Intercept
9.7 m
From
145.3 m
To
155 m
Intercept Depth
145.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:145.3-155
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
4.54
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good width from a new vein discovery outside the existing block model, indicating expansion potential.

Positive factors

  • High gold grade (4.28 g/t) is moderate for an orogenic deposit.
  • Good intercept width (9.70 m).
  • Part of new high-grade veins discovered outside the block model.

Negative factors

  • True width not explicitly stated, only estimated range.

Evidence · table

“4.28”

Context: 9.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 11Grade Unit: g/tIntercept: 9.7 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
11
Grade Unit
g/t
Intercept
9.7 m
From
145.3 m
To
155 m
Intercept Depth
145.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:145.3-155
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
4.54
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery and contributes to a moderate AuEq grade over a good width.

Positive factors

  • Good intercept width (9.70 m).
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 4.54 g/t AuEq is moderate.

Negative factors

  • Silver grade (11 g/t) is weak.
  • True width not explicitly stated, only estimated range.

Evidence · table

“11”

Context: 9.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · copperGrade: 0.05Grade Unit: %Intercept: 9.7 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.05
Grade Unit
%
Intercept
9.7 m
From
145.3 m
To
155 m
Intercept Depth
145.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:145.3-155
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
4.54
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The copper grade is very weak, but the intercept is part of a new vein discovery and contributes to a moderate AuEq grade over a good width.

Positive factors

  • Good intercept width (9.70 m).
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 4.54 g/t AuEq is moderate.

Negative factors

  • Copper grade (0.05%) is very weak.
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.05”

Context: 9.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 5.56Grade Unit: g/tIntercept: 5.3 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
5.56
Grade Unit
g/t
Intercept
5.3 m
From
43.7 m
To
49 m
Intercept Depth
43.7 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:43.7-49
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.75
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade over a moderate width from a new vein discovery outside the existing block model, indicating expansion potential.

Positive factors

  • High gold grade (5.56 g/t) is strong for an orogenic deposit.
  • Moderate intercept width (5.30 m).
  • Part of new high-grade veins discovered outside the block model.

Negative factors

  • True width not explicitly stated, only estimated range.

Evidence · table

“5.56”

Context: 5.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 53Grade Unit: g/tIntercept: 5.3 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
53
Grade Unit
g/t
Intercept
5.3 m
From
43.7 m
To
49 m
Intercept Depth
43.7 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:43.7-49
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.75
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a moderate width from a new vein discovery, contributing to a strong AuEq grade.

Positive factors

  • High silver grade (53 g/t) is strong.
  • Moderate intercept width (5.30 m).
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 6.75 g/t AuEq is strong.

Negative factors

  • True width not explicitly stated, only estimated range.

Evidence · table

“53”

Context: 5.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · copperGrade: 0.15Grade Unit: %Intercept: 5.3 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.15
Grade Unit
%
Intercept
5.3 m
From
43.7 m
To
49 m
Intercept Depth
43.7 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:43.7-49
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.75
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The copper grade is very weak, but the intercept is part of a new vein discovery and contributes to a strong AuEq grade over a moderate width.

Positive factors

  • Moderate intercept width (5.30 m).
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 6.75 g/t AuEq is strong.

Negative factors

  • Copper grade (0.15%) is very weak.
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.15”

Context: 5.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 7.37Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
7.37
Grade Unit
g/t
Intercept
1 m
From
89.9 m
To
90.9 m
Intercept Depth
89.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:89.9-90.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery outside the existing block model, indicating expansion potential.

Positive factors

  • High gold grade (7.37 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered outside the block model.

Negative factors

  • Intercept width is narrow (1.00 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“7.37”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 57Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
57
Grade Unit
g/t
Intercept
1 m
From
89.9 m
To
90.9 m
Intercept Depth
89.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:89.9-90.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade from a new vein discovery, contributing to a strong AuEq grade.

Positive factors

  • High silver grade (57 g/t) is strong.
  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 8.64 g/t AuEq is strong.

Negative factors

  • Intercept width is narrow (1.00 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“57”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · copperGrade: 0.16Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
copper
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
0.16
Grade Unit
%
Intercept
1 m
From
89.9 m
To
90.9 m
Intercept Depth
89.9 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:89.9-90.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The copper grade is very weak, but the intercept is part of a new vein discovery and contributes to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered outside the block model.
  • Metal equivalent grade of 8.64 g/t AuEq is strong.

Negative factors

  • Copper grade (0.16%) is very weak.
  • Intercept width is narrow (1.00 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“0.16”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 6.14Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6.14
Grade Unit
g/t
Intercept
2.6 m
From
181.5 m
To
184.1 m
Intercept Depth
181.5 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:181.5-184.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery within the existing block model, indicating higher grades than previously estimated.

Positive factors

  • High gold grade (6.14 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model, exceeding estimates.

Negative factors

  • Intercept width is narrow (2.60 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6.14”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 10Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
10
Grade Unit
g/t
Intercept
2.6 m
From
181.5 m
To
184.1 m
Intercept Depth
181.5 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:181.5-184.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model, exceeding estimates.
  • Metal equivalent grade of 6.34 g/t AuEq is strong.

Negative factors

  • Silver grade (10 g/t) is weak.
  • Intercept width is narrow (2.60 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“10”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 6.95Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6.95
Grade Unit
g/t
Intercept
1.35 m
From
188.85 m
To
190.2 m
Intercept Depth
188.85 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:188.85-190.2
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.07
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery within the existing block model, contributing positively to the project.

Positive factors

  • High gold grade (6.95 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model.

Negative factors

  • Intercept width is narrow (1.35 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6.95”

Context: 1.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 6Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.35 m
From
188.85 m
To
190.2 m
Intercept Depth
188.85 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:188.85-190.2
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
7.07
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model.
  • Metal equivalent grade of 7.07 g/t AuEq is strong.

Negative factors

  • Silver grade (6 g/t) is weak.
  • Intercept width is narrow (1.35 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6”

Context: 1.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 8.2Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
8.2
Grade Unit
g/t
Intercept
1.25 m
From
299.45 m
To
300.7 m
Intercept Depth
299.45 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:299.45-300.7
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a new vein discovery within the existing block model, contributing positively to the project.

Positive factors

  • High gold grade (8.20 g/t) is strong for an orogenic deposit.
  • Part of new high-grade veins discovered within the block model.

Negative factors

  • Intercept width is narrow (1.25 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“8.20”

Context: 1.25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 5Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
5
Grade Unit
g/t
Intercept
1.25 m
From
299.45 m
To
300.7 m
Intercept Depth
299.45 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:299.45-300.7
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
8.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a new vein discovery within the existing block model, contributing to a strong AuEq grade.

Positive factors

  • Part of new high-grade veins discovered within the block model.
  • Metal equivalent grade of 8.29 g/t AuEq is strong.

Negative factors

  • Silver grade (5 g/t) is weak.
  • Intercept width is narrow (1.25 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“5”

Context: 1.25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 5.25Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
5.25
Grade Unit
g/t
Intercept
2.6 m
From
116 m
To
118.6 m
Intercept Depth
116 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:116-118.6
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
5.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • High gold grade (5.25 g/t) is strong for an orogenic deposit.
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • Intercept width is narrow (2.60 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“5.25”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 5Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
5
Grade Unit
g/t
Intercept
2.6 m
From
116 m
To
118.6 m
Intercept Depth
116 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:116-118.6
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
5.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a Ramp Zone step-out and contributes to a strong AuEq grade.

Positive factors

  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 5.35 g/t AuEq is strong.

Negative factors

  • Silver grade (5 g/t) is weak.
  • Intercept width is narrow (2.60 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“5”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 2.24Grade Unit: g/tIntercept: 13.85 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
2.24
Grade Unit
g/t
Intercept
13.85 m
From
188.05 m
To
201.9 m
Intercept Depth
188.05 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:188.05-201.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good width from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • Gold grade (2.24 g/t) is above the 'weak' threshold for an orogenic deposit.
  • Good intercept width (13.85 m).
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • True width not explicitly stated, only estimated range.

Evidence · table

“2.24”

Context: 13.85

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 3Grade Unit: g/tIntercept: 13.85 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
3
Grade Unit
g/t
Intercept
13.85 m
From
188.05 m
To
201.9 m
Intercept Depth
188.05 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:188.05-201.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is very weak, but the intercept is part of a Ramp Zone step-out and contributes to a weak AuEq grade over a good width.

Positive factors

  • Good intercept width (13.85 m).
  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 2.30 g/t AuEq is weak.

Negative factors

  • Silver grade (3 g/t) is very weak.
  • True width not explicitly stated, only estimated range.

Evidence · table

“3”

Context: 13.85

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 2.69Grade Unit: g/tIntercept: 8.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
2.69
Grade Unit
g/t
Intercept
8.6 m
From
209.3 m
To
217.9 m
Intercept Depth
209.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:209.3-217.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.71
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good width from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • Gold grade (2.69 g/t) is above the 'weak' threshold for an orogenic deposit.
  • Good intercept width (8.60 m).
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • True width not explicitly stated, only estimated range.

Evidence · table

“2.69”

Context: 8.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 1Grade Unit: g/tIntercept: 8.6 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
1
Grade Unit
g/t
Intercept
8.6 m
From
209.3 m
To
217.9 m
Intercept Depth
209.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:209.3-217.9
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.71
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is very weak, but the intercept is part of a Ramp Zone step-out and contributes to a weak AuEq grade over a good width.

Positive factors

  • Good intercept width (8.60 m).
  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 2.71 g/t AuEq is weak.

Negative factors

  • Silver grade (1 g/t) is very weak.
  • True width not explicitly stated, only estimated range.

Evidence · table

“1”

Context: 8.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · goldGrade: 6.58Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
6.58
Grade Unit
g/t
Intercept
1 m
From
246 m
To
247 m
Intercept Depth
246 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:246-247
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • High gold grade (6.58 g/t) is strong for an orogenic deposit.
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • Intercept width is narrow (1.00 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“6.58”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D1Guayabales · silverGrade: 1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
APC171-D1
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
1
Grade Unit
g/t
Intercept
1 m
From
246 m
To
247 m
Intercept Depth
246 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D1:246-247
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
6.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is very weak, but the intercept is part of a Ramp Zone step-out and contributes to a strong AuEq grade.

Positive factors

  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 6.60 g/t AuEq is strong.

Negative factors

  • Silver grade (1 g/t) is very weak.
  • Intercept width is narrow (1.00 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“1”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 8.97Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
8.97
Grade Unit
g/t
Intercept
2.1 m
From
604 m
To
606.1 m
Intercept Depth
604 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:604-606.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
9.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • High gold grade (8.97 g/t) is strong for an orogenic deposit.
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • Intercept width is narrow (2.10 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“8.97”

Context: 2.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 13Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
13
Grade Unit
g/t
Intercept
2.1 m
From
604 m
To
606.1 m
Intercept Depth
604 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:604-606.1
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
9.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is weak, but the intercept is part of a Ramp Zone step-out and contributes to a strong AuEq grade.

Positive factors

  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 9.21 g/t AuEq is strong.

Negative factors

  • Silver grade (13 g/t) is weak.
  • Intercept width is narrow (2.10 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“13”

Context: 2.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · goldGrade: 2.58Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
2.58
Grade Unit
g/t
Intercept
2.75 m
From
616.3 m
To
619.05 m
Intercept Depth
616.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:616.3-619.05
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade from a Ramp Zone step-out, extending known mineralization westward.

Positive factors

  • Gold grade (2.58 g/t) is above the 'weak' threshold for an orogenic deposit.
  • Part of Ramp Zone step-outs, extending mineralization westward.

Negative factors

  • Intercept width is narrow (2.75 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“2.58”

Context: 2.75

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

APC171-D2Guayabales · silverGrade: 1Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
APC171-D2
Project
Guayabales
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
CNL

Geometry

Grade
1
Grade Unit
g/t
Intercept
2.75 m
From
616.3 m
To
619.05 m
Intercept Depth
616.3 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
APC171-D2:616.3-619.05
Mining Method
underground

Location

Location
Pad24
Loc. Source
document

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
bismuth, tellurium, arsenic

Metal Equivalent

Metal Eq. Grade
2.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-24T00:00:00.000Z

Reasoning: The silver grade is very weak, but the intercept is part of a Ramp Zone step-out and contributes to a weak AuEq grade.

Positive factors

  • Part of Ramp Zone step-outs, extending mineralization westward.
  • Metal equivalent grade of 2.60 g/t AuEq is weak.

Negative factors

  • Silver grade (1 g/t) is very weak.
  • Intercept width is narrow (2.75 m).
  • True width not explicitly stated, only estimated range.

Evidence · table

“1”

Context: 2.75

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.