Archive
Original announcement by thenewswire on
- Company
- Mithril Silver and Gold Limited
- Ticker
- MTH
- Exchange
- Unavailable
- Region
- Durango State, Mexico
- Primary commodity
- Silver
- Secondary commodities
- Gold, Lead, Zinc
- Document categories
- Drill results, Resource update, Other
- Extracted
- 2026-10-01 05:40:56 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Mithril Silver and Gold Limited announced high-grade silver and gold drill results from its maiden program at Target 5 within the Copalquin Project in Mexico, confirming a large epithermal system. The company also provided an update on ongoing resource drilling at Target 1 and re-stated its historical JORC/NI 43-101 compliant resource estimate for Target 1. Exploration efforts are continuing with further drilling planned to expand known mineralized zones and test new targets across the district.
Reasoning: Mithril reports high-grade silver and gold drill results from its maiden program at Target 5, confirming a significant epithermal system with expansion potential. The company also provides an update on ongoing resource drilling at Target 1 and re-states a historical JORC/NI 43-101 compliant resource estimate for context.
Positive factors
- High-grade silver and gold intercepts from maiden drilling at Target 5
- Confirmation of a large mineralized system with expansion potential
- Ongoing resource drilling at Target 1
- Detailed QA/QC procedures disclosed
- Metal equivalent assumptions clearly stated
- JORC and NI 43-101 compliant reporting for historical resource
Negative factors
- Intercepts reported as downhole length with true width not always known
- Resource estimate is historical, not a new update in this release
Facts used in scoring: 112
Extracted facts
Stored fact records: 112. Some facts used in scoring do not have a stored record.
Drill Results (112)
AP25-001Copalquin · goldGrade: 1.21Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.21
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 32 m
- To
- 32.5 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:32-32.5
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 124
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 1.21 g/t gold, which is a moderate grade for epithermal deposits, but the narrow width limits its materiality.
Negative factors
- Narrow intercept
Evidence · table
“1.21”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-001Copalquin · silverGrade: 124Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 124
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 32 m
- To
- 32.5 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:32-32.5
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 124
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 124 g/t AgEq, which is a moderate grade for epithermal deposits, but the narrow width limits its materiality.
Negative factors
- Narrow intercept
Evidence · table
“124”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-001Copalquin · goldGrade: 1.285Grade Unit: g/tIntercept: 0.52 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.285
- Grade Unit
- g/t
- Intercept
- 0.52 m
- From
- 279.83 m
- To
- 280.35 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:279.83-280.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 257
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.52m at 1.285 g/t gold, which is a moderate grade for epithermal deposits, but the narrow width limits its materiality.
Negative factors
- Narrow intercept
Evidence · table
“1.285”
Context: 0.52
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-001Copalquin · silverGrade: 257Grade Unit: g/tIntercept: 0.52 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 257
- Grade Unit
- g/t
- Intercept
- 0.52 m
- From
- 279.83 m
- To
- 280.35 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:279.83-280.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 257
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.52m at 257 g/t AgEq, which is a strong grade for epithermal deposits, but the narrow width limits its materiality.
Negative factors
- Narrow intercept
Evidence · table
“257”
Context: 0.52
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-002Copalquin · goldGrade: 1.26Grade Unit: g/tIntercept: 3.85 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 3.85 m
- From
- 31.45 m
- To
- 35.3 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-35.3
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 131
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 3.85m at 1.26 g/t gold, which is a moderate grade for epithermal deposits.
Evidence · table
“1.26”
Context: 3.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-002Copalquin · silverGrade: 131Grade Unit: g/tIntercept: 3.85 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 131
- Grade Unit
- g/t
- Intercept
- 3.85 m
- From
- 31.45 m
- To
- 35.3 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-35.3
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 131
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 3.85m at 131 g/t AgEq, which is a moderate grade for epithermal deposits.
Evidence · table
“131”
Context: 3.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-002Copalquin · goldGrade: 7.74Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 7.74
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 31.45 m
- To
- 31.95 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-31.95
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 729
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 0.5m at 7.74 g/t gold, which is strong for epithermal deposits.
Positive factors
- High grade
Negative factors
- Narrow intercept
Evidence · table
“7.74”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-002Copalquin · silverGrade: 729Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 729
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 31.45 m
- To
- 31.95 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-31.95
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 729
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, bonanza-grade intercept of 0.5m at 729 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Bonanza intercept
- High grade
Negative factors
- Narrow intercept
Evidence · table
“729”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · goldGrade: 0.393Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.393
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 34.5 m
- To
- 35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:34.5-35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 90
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.393 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.393”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · silverGrade: 90Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 90
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 34.5 m
- To
- 35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:34.5-35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 90
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 90 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“90”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · goldGrade: 2.28Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 2.28
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 93.6 m
- To
- 96.35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:93.6-96.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 660
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 2.75m at 2.28 g/t gold, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Evidence · table
“2.28”
Context: 2.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · silverGrade: 660Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 660
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 93.6 m
- To
- 96.35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:93.6-96.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 660
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 2.75m at 660 g/t AgEq, which is an exceptional grade for epithermal deposits.
Positive factors
- Exceptional grade
Evidence · table
“660”
Context: 2.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · goldGrade: 5.8Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 5.8
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 94.7 m
- To
- 95.7 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:94.7-95.7
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1714
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 1.0m at 5.8 g/t gold, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“5.8”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · silverGrade: 1714Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1714
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 94.7 m
- To
- 95.7 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:94.7-95.7
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1714
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, bonanza-grade intercept of 1.0m at 1714 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Bonanza intercept
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“1,714”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · goldGrade: 2.89Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 2.89
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 214 m
- To
- 215.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:214-215.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 203
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.3m at 2.89 g/t gold, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Negative factors
- Narrow intercept
Evidence · table
“2.89”
Context: 1.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · silverGrade: 203Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 203
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 214 m
- To
- 215.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:214-215.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 203
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.3m at 203 g/t AgEq, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Negative factors
- Narrow intercept
Evidence · table
“203”
Context: 1.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · goldGrade: 2.38Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 2.38
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 231.6 m
- To
- 232.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:231.6-232.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 168
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.7m at 2.38 g/t gold, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Negative factors
- Narrow intercept
Evidence · table
“2.38”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-003Copalquin · silverGrade: 168Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 168
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 231.6 m
- To
- 232.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:231.6-232.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 168
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.7m at 168 g/t AgEq, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Negative factors
- Narrow intercept
Evidence · table
“168”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-004Copalquin · goldGrade: 0.57Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- AP25-004
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 89.2 m
- To
- 90.65 m
- Hole Depth
- 291 m
- Intercept Depth
- 89.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-004:89.2-90.65
- Mining Method
- mixed
Location
- Easting
- 287903.2
- Northing
- 2822590
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 760.85 m
- Azimuth
- 30 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 150
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.45m at 0.57 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.57”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-004Copalquin · silverGrade: 150Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- AP25-004
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 150
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 89.2 m
- To
- 90.65 m
- Hole Depth
- 291 m
- Intercept Depth
- 89.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-004:89.2-90.65
- Mining Method
- mixed
Location
- Easting
- 287903.2
- Northing
- 2822590
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 760.85 m
- Azimuth
- 30 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 150
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.45m at 150 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“150”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 4.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 4.05 m
- From
- 35.65 m
- To
- 39.7 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:35.65-39.7
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 4.05m at 0.19 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Weak grade
Evidence · table
“0.19”
Context: 4.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · silverGrade: 75Grade Unit: g/tIntercept: 4.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 75
- Grade Unit
- g/t
- Intercept
- 4.05 m
- From
- 35.65 m
- To
- 39.7 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:35.65-39.7
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 4.05m at 75 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Weak grade
Evidence · table
“75”
Context: 4.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · goldGrade: 0.41Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 1.6 m
- From
- 36.75 m
- To
- 38.35 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:36.75-38.35
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.6m at 0.41 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.41”
Context: 1.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · silverGrade: 159Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 159
- Grade Unit
- g/t
- Intercept
- 1.6 m
- From
- 36.75 m
- To
- 38.35 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:36.75-38.35
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.6m at 159 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“159”
Context: 1.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · goldGrade: 1.71Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 90.15 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:90.15-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 366
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 3.35m at 1.71 g/t gold, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Evidence · table
“1.71”
Context: 3.35
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · silverGrade: 366Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 366
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 90.15 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:90.15-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 366
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 3.35m at 366 g/t AgEq, which is an exceptional grade for epithermal deposits.
Positive factors
- Exceptional grade
Evidence · table
“366”
Context: 3.35
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · goldGrade: 5.35Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 5.35
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:92.45-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 1.05m at 5.35 g/t gold, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“5.35”
Context: 1.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-005Copalquin · silverGrade: 1146Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1146
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:92.45-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, bonanza-grade intercept of 1.05m at 1146 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Bonanza intercept
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“1,146”
Context: 1.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · goldGrade: 4.548Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 4.548
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 119.2 m
- To
- 120.45 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:119.2-120.45
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 727
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 1.25m at 4.548 g/t gold, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“4.548”
Context: 1.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · silverGrade: 727Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 727
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 119.2 m
- To
- 120.45 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:119.2-120.45
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 727
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, bonanza-grade intercept of 1.25m at 727 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Bonanza intercept
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“727”
Context: 1.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · goldGrade: 2.41Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 2.41
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 138.1 m
- To
- 139 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:138.1-139
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 616
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.9m at 2.41 g/t gold, which is a strong grade for epithermal deposits.
Positive factors
- Strong grade
Negative factors
- Narrow intercept
Evidence · table
“2.41”
Context: 0.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · silverGrade: 616Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 616
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 138.1 m
- To
- 139 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:138.1-139
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 616
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 0.9m at 616 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“616”
Context: 0.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · goldGrade: 1.51Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.51
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 149.75 m
- To
- 150.55 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:149.75-150.55
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 427
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.8m at 1.51 g/t gold, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“1.51”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · silverGrade: 427Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 427
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 149.75 m
- To
- 150.55 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:149.75-150.55
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 427
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 0.8m at 427 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“427”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 301.4 m
- To
- 301.9 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:301.4-301.9
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.19 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.19”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-006Copalquin · silverGrade: 86Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 86
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 301.4 m
- To
- 301.9 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:301.4-301.9
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 86 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“86”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · goldGrade: 0.23Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 51 m
- To
- 52.5 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:51-52.5
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 31
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.5m at 0.23 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.23”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · silverGrade: 31Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 31
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 51 m
- To
- 52.5 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:51-52.5
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 31
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.5m at 31 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“31”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · goldGrade: 0.27Grade Unit: g/tIntercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2.05 m
- From
- 62.75 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:62.75-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 107
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 2.05m at 0.27 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.27”
Context: 2.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · silverGrade: 107Grade Unit: g/tIntercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 107
- Grade Unit
- g/t
- Intercept
- 2.05 m
- From
- 62.75 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:62.75-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 107
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 2.05m at 107 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“107”
Context: 2.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · goldGrade: 0.9Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.9
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 64.3 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:64.3-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.9 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.90”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-007Copalquin · silverGrade: 374Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 374
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 64.3 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:64.3-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 374
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 0.5m at 374 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“374”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-008Copalquin · goldGrade: 0.34Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-008
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 78.2 m
- To
- 78.9 m
- Hole Depth
- 177 m
- Intercept Depth
- 78.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-008:78.2-78.9
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -77 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 36
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.7m at 0.34 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.34”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-008Copalquin · silverGrade: 36Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-008
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 36
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 78.2 m
- To
- 78.9 m
- Hole Depth
- 177 m
- Intercept Depth
- 78.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-008:78.2-78.9
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -77 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 36
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.7m at 36 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“36”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 85 m
- To
- 85.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:85-85.8
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 30
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.8m at 0.09 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.09”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · silverGrade: 30Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 30
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 85 m
- To
- 85.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:85-85.8
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 30
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.8m at 30 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“30”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · goldGrade: 0.3Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 89.45 m
- To
- 95.55 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:89.45-95.55
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 43
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 6.1m at 0.3 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Weak grade
Evidence · table
“0.30”
Context: 6.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · silverGrade: 43Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 43
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 89.45 m
- To
- 95.55 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:89.45-95.55
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 43
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A moderate intercept of 6.1m at 43 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Weak grade
Evidence · table
“43”
Context: 6.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 99.6 m
- To
- 100.1 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:99.6-100.1
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 18
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.1 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.10”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-009Copalquin · silverGrade: 18Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 18
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 99.6 m
- To
- 100.1 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:99.6-100.1
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 18
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 18 g/t AgEq, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“18”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · goldGrade: 0.5Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.5
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 96 m
- To
- 96.5 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:96-96.5
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 83
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.5 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.50”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · silverGrade: 83Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 83
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 96 m
- To
- 96.5 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:96-96.5
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 83
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 83 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“83”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · goldGrade: 0.45Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 443
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.45 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.45”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · silverGrade: 443Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 443
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 443
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow, high-grade intercept of 0.5m at 443 g/t AgEq, which is exceptional for epithermal deposits.
Positive factors
- Exceptional grade
Negative factors
- Narrow intercept
Evidence · table
“443”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · leadGrade: 3.4Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 3.4
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 3.4% lead, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · text
“3.4% lead”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-010Copalquin · zincGrade: 1.7Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.7
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 1.7% zinc, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · text
“1.70% zinc”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-011Copalquin · goldGrade: 0.06Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-011
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 263.15 m
- To
- 263.65 m
- Hole Depth
- 381 m
- Intercept Depth
- 263.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-011:263.15-263.65
- Mining Method
- mixed
Location
- Easting
- 287859
- Northing
- 2822568
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 744.79 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.06 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.06”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-011Copalquin · silverGrade: 29Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-011
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 29
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 263.15 m
- To
- 263.65 m
- Hole Depth
- 381 m
- Intercept Depth
- 263.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-011:263.15-263.65
- Mining Method
- mixed
Location
- Easting
- 287859
- Northing
- 2822568
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 744.79 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 29 g/t AgEq, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“29”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · goldGrade: 0.22Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 84.45 m
- To
- 84.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:84.45-84.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 121
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 0.22 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.22”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · silverGrade: 121Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 121
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 84.45 m
- To
- 84.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:84.45-84.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 121
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.5m at 121 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“121”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · goldGrade: 0.14Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232.95 m
- To
- 233.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:232.95-233.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 115
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.0m at 0.14 g/t gold, which is a very weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.14”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · silverGrade: 115Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 115
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232.95 m
- To
- 233.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:232.95-233.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 115
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 1.0m at 115 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“115”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · goldGrade: 0.63Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 347.05 m
- To
- 347.65 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:347.05-347.65
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 130
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.6m at 0.63 g/t gold, which is a weak grade for epithermal deposits.
Negative factors
- Narrow intercept
- Weak grade
Evidence · table
“0.63”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
AP25-012Copalquin · silverGrade: 130Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 130
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 347.05 m
- To
- 347.65 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:347.05-347.65
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 130
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.25
- Cutoff Unit
- g/t AuEq
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: A narrow intercept of 0.6m at 130 g/t AgEq, which is a moderate grade for epithermal deposits.
Positive factors
- Moderate grade
Negative factors
- Narrow intercept
Evidence · table
“130”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
(IncludingCopalquin · goldGrade: 5.35Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- (Including
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 5.35
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Intercept Depth
- 92.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- (Including:92.45-93.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 5.35 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.6 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.35 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.35”
Context: (Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
(IncludingCopalquin · silverGrade: 771Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- (Including
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 771
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Intercept Depth
- 92.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- (Including:92.45-93.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 771 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 809.6 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 771 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“771”
Context: (Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.05Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 73.65 m
- To
- 74.4 m
- Intercept Depth
- 73.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:73.65-74.4
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.05 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 15.6Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 15.6
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 73.65 m
- To
- 74.4 m
- Intercept Depth
- 73.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:73.65-74.4
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 15.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.7 g/t·m is below.
Negative factors
- 15.6 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“15.6”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.44Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 78.75 m
- To
- 79.25 m
- Intercept Depth
- 78.75 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:78.75-79.25
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.44 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.44”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 55.5Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 55.5
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 78.75 m
- To
- 79.25 m
- Intercept Depth
- 78.75 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:78.75-79.25
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 55.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 27.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“55.5”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.16Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 384.2 m
- To
- 384.9 m
- Intercept Depth
- 384.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:384.2-384.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 15
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.16 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 3.8Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 3.8
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 384.2 m
- To
- 384.9 m
- Intercept Depth
- 384.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:384.2-384.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 15
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 3.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 3.8 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.8”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 0.13Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 78 m
- To
- 78.55 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:78-78.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 65.9Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 65.9
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 78 m
- To
- 78.55 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:78-78.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 65.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 36.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“65.9”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 1.14Grade Unit: g/tIntercept: 2.85 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.14
- Grade Unit
- g/t
- Intercept
- 2.85 m
- From
- 79.6 m
- To
- 82.45 m
- Intercept Depth
- 79.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:79.6-82.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 145
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.14 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.2 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.14”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 64.7Grade Unit: g/tIntercept: 2.85 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 64.7
- Grade Unit
- g/t
- Intercept
- 2.85 m
- From
- 79.6 m
- To
- 82.45 m
- Intercept Depth
- 79.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:79.6-82.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 145
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 64.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 184.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“64.7”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 1.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 1.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 185.5 m
- To
- 186 m
- Intercept Depth
- 185.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:185.5-186
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 163
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.4 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.40”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 64.7Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 64.7
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 185.5 m
- To
- 186 m
- Intercept Depth
- 185.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:185.5-186
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 163
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 64.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 32.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“64.7”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 0.34Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 407.7 m
- To
- 408.9 m
- Intercept Depth
- 407.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:407.7-408.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 82
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.34 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.34”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 57.9Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 57.9
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 407.7 m
- To
- 408.9 m
- Intercept Depth
- 407.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:407.7-408.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 82
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 57.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 69.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“57.9”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.26Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 9 m
- To
- 10 m
- Intercept Depth
- 9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:9-10
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 47
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.26 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.26 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.26”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 29.1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 29.1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 9 m
- To
- 10 m
- Intercept Depth
- 9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:9-10
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 47
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 29.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 29.1 g/t·m is below.
Negative factors
- 29.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29.1”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 57.6 m
- To
- 58.1 m
- Intercept Depth
- 57.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:57.6-58.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 24
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 17.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 17.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 57.6 m
- To
- 58.1 m
- Intercept Depth
- 57.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:57.6-58.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 24
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 17.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.6 g/t·m is below.
Negative factors
- 17.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.1”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.18Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 63 m
- To
- 63.75 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:63-63.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 32
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 19.2Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 19.2
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 63 m
- To
- 63.75 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:63-63.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 32
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 19.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.4 g/t·m is below.
Negative factors
- 19.2 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“19.2”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 3.05 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 3.05 m
- From
- 193.05 m
- To
- 196.1 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 170
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 165Grade Unit: g/tIntercept: 3.05 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 165
- Grade Unit
- g/t
- Intercept
- 3.05 m
- From
- 193.05 m
- To
- 196.1 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 170
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 165 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 503.2 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“165”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.11Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 193.05 m
- To
- 193.9 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-193.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 237
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.11 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 229Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 229
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 193.05 m
- To
- 193.9 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-193.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 237
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 229 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 194.7 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 229 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“229”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.65 m
- From
- 195.45 m
- To
- 196.1 m
- Intercept Depth
- 195.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:195.45-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 271
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 265Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 265
- Grade Unit
- g/t
- Intercept
- 0.65 m
- From
- 195.45 m
- To
- 196.1 m
- Intercept Depth
- 195.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:195.45-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 271
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 265 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 172.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 265 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“265”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 36.5 m
- To
- 37.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:36.5-37.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · silverGrade: 21.9Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 21.9
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 36.5 m
- To
- 37.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:36.5-37.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 21.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 21.9 g/t·m is below.
Negative factors
- 21.9 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“21.9”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · goldGrade: 0.18Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 57.1 m
- To
- 60.45 m
- Intercept Depth
- 57.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:57.1-60.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 46
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · silverGrade: 33.7Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 33.7
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 57.1 m
- To
- 60.45 m
- Intercept Depth
- 57.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:57.1-60.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 46
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 33.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 112.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“33.7”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 35.65 m
- To
- 36.35 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:35.65-36.35
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 41
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 34.8Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 34.8
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 35.65 m
- To
- 36.35 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:35.65-36.35
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 41
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 34.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 24.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“34.8”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 77.35 m
- To
- 77.85 m
- Intercept Depth
- 77.35 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:77.35-77.85
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 66
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.19 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.19 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.19”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 52.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 52.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 77.35 m
- To
- 77.85 m
- Intercept Depth
- 77.35 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:77.35-77.85
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 66
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 52.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 26.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“52.8”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.39Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.85 m
- To
- 81.1 m
- Intercept Depth
- 79.85 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:79.85-81.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 57
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.39 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.39”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 29.4Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 29.4
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.85 m
- To
- 81.1 m
- Intercept Depth
- 79.85 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:79.85-81.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 57
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 29.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 36.8 g/t·m is below.
Negative factors
- 29.4 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29.4”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 33.8 m
- To
- 34.55 m
- Intercept Depth
- 33.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:33.8-34.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 26
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · silverGrade: 21.3Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 21.3
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 33.8 m
- To
- 34.55 m
- Intercept Depth
- 33.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:33.8-34.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 26
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 21.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.0 g/t·m is below.
Negative factors
- 21.3 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“21.3”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 45.65 m
- To
- 46.5 m
- Intercept Depth
- 45.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:45.65-46.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 45
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · silverGrade: 37.4Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 37.4
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 45.65 m
- To
- 46.5 m
- Intercept Depth
- 45.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:45.65-46.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 45
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 37.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 31.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“37.4”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-004Copalquin · goldGrade: 0.53Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-004
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.5 m
- To
- 80.75 m
- Intercept Depth
- 79.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-004:79.5-80.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 103
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: TA25-004
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-004Copalquin · silverGrade: 66.35Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-004
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 66.35
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.5 m
- To
- 80.75 m
- Intercept Depth
- 79.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-004:79.5-80.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 103
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 66.35 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 82.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“66.35”
Context: TA25-004
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · goldGrade: 0.13Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 1 m
- To
- 3 m
- Intercept Depth
- 1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:1-3
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 28
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · silverGrade: 18.55Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 18.55
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 1 m
- To
- 3 m
- Intercept Depth
- 1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:1-3
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 28
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 18.55 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 37.1 g/t·m is below.
Negative factors
- 18.55 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“18.55”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 141 m
- To
- 141.55 m
- Intercept Depth
- 141 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:141-141.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 89
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · silverGrade: 82.2Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MTH
Geometry
- Grade
- 82.2
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 141 m
- To
- 141.55 m
- Intercept Depth
- 141 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:141-141.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 89
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 82.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“82.2”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.