Archive
Original announcement by thenewswire on
- Company
- LAURION Mineral Exploration Inc.
- Ticker
- LME
- Exchange
- TSXV
- Region
- Greenstone, Ontario
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-10-01 06:17:54 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
LAURION Mineral Exploration announced encouraging results from its Summer 2025 drill exploration program at the Ishkõday Project in Ontario. The program, totaling 1,806 meters across four holes, successfully extended gold mineralization into previously untested ground between the historic Brenbar and Sturgeon River Mine areas. While the results are in the early stages of testing a geologically complex corridor, they provide valuable insights into mineralization continuity, with individual intercepts up to 2.67 g/t Au over 0.7 meters.
Reasoning: The exploration program successfully extended mineralization into new ground, but the reported gold grades are narrow and generally low to weak for an inferred underground mining method, and true widths are not yet determined, limiting the immediate economic significance.
Positive factors
- Exploration success in untested ground, extending mineralization continuity.
- QA/QC protocols are disclosed.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
- Early stages of testing in a geologically complex corridor.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 63
Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release explicitly states that 'LAURION employs an industry standard system of external standards, blanks and duplicates for all of its sampling, in addition to the QA/QC protocol employed by the laboratory.' and mentions ALS as the laboratory, with QP sign-off.
Evidence · text
“LAURION employs an industry standard system of external standards, blanks and duplicates for all of its sampling, in addition to the QA/QC protocol employed by the laboratory.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The document explicitly states that 'The true widths of the mineralized zones are not known at this time as there is insufficient information to determine the orientation of the mineralization.'
Evidence · text
“The true widths of the mineralized zones are not known at this time as there is insufficient information to determine the orientation of the mineralization.”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drilling program is described as 'stepping out to the northeast of the Brenbar historic mine shaft targeting the untested M50 Quartz vein series' and 'first time drilling has been completed across this untested structural corridor'.
Evidence · text
“stepping out to the northeast of the Brenbar historic mine shaft targeting the untested M50 Quartz vein series”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: The document does not disclose the cut-off grade used for compositing the reported intervals.
Evidence · text
“Note: (Intervals represent core length. The interval widths reported are down-hole widths. The true widths of the mineralized zones are not known at this time as there is insufficient information to determine the orientation of the mineralization. True widths are estimated at ~70–90% of reported intervals.)”
Low Gradenegative · Story-specific tag
No canonical definition is currently available.
Why it applies: The highest reported gold grade is 2.67 g/t Au over 0.7m, which is considered weak for an inferred underground mining method (threshold ≥2.5 g/t), and many other intercepts are below this.
Evidence · table
“2.67”
Context: 0.7
Extracted facts
Stored fact records: 63. Some facts used in scoring do not have a stored record.
Drill Results (63)
LME25-063Ishkõday · goldGrade: 0.38Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.38
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 11.6 m
- To
- 12.1 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:11.6-12.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.38”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.87Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.87
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 26.8 m
- To
- 27.5 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:26.8-27.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.87”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.45Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 33.5 m
- To
- 34.5 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:33.5-34.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.45”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.34Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 47 m
- To
- 48 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:47-48
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.34”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.91Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.91
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 85 m
- To
- 85.5 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:85-85.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.91”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 2.67Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 2.67
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 139.5 m
- To
- 140.2 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:139.5-140.2
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow intercept with a grade that is weak for an inferred underground mining method, in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“2.67”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.94Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.94
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 144.9 m
- To
- 145.5 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:144.9-145.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.94”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.58Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 228.4 m
- To
- 228.9 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:228.4-228.9
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.58”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.75Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.75
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 262.5 m
- To
- 264 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:262.5-264
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.75”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 0.52Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.52
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 251.5 m
- To
- 283 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:251.5-283
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.52”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-063Ishkõday · goldGrade: 1.26Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-063
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 393.4 m
- To
- 393.9 m
- Hole Depth
- 435 m
- Intercept Depth
- 11.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-063:393.4-393.9
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“1.26”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.29Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 22.5 m
- To
- 23.1 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:22.5-23.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.29”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.92Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.92
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 55 m
- To
- 56 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:55-56
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.92”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.2Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 83 m
- To
- 84.5 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:83-84.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.20”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.2Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 151 m
- To
- 152 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:151-152
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.20”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.26Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 218.8 m
- To
- 219.3 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:218.8-219.3
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.26”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.23Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 246 m
- To
- 247.1 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:246-247.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.23”
Context: 1.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.97Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.97
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 313 m
- To
- 313.5 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:313-313.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.97”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.27Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 331 m
- To
- 332 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:331-332
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.27”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.25Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 354 m
- To
- 354.5 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:354-354.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.25”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-064Ishkõday · goldGrade: 0.7Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-064
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 356.1 m
- To
- 356.6 m
- Hole Depth
- 366 m
- Intercept Depth
- 22.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-064:356.1-356.6
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.70”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.71Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.71
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 5.7 m
- To
- 6.2 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:5.7-6.2
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.71”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.31Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 8 m
- To
- 8.8 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:8-8.8
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.31”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.23Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 15.5 m
- To
- 17 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:15.5-17
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.23”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.48Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 40.3 m
- To
- 40.9 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:40.3-40.9
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.48”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.23Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 54.5 m
- To
- 55.1 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:54.5-55.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.23”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.27Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 64.7 m
- To
- 65.4 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:64.7-65.4
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.27”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.69Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.69
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 75.4 m
- To
- 76 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:75.4-76
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.69”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 1.78Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 1.78
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 91.1 m
- To
- 91.6 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:91.1-91.6
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“1.78”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.32Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 94 m
- To
- 95 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:94-95
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.32”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.95Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.95
- Grade Unit
- g/t
- Intercept
- 1.8 m
- From
- 149.6 m
- To
- 151.4 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:149.6-151.4
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.95”
Context: 1.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 1.9Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 1.9
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 150.6 m
- To
- 151.4 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:150.6-151.4
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade sub-interval in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“1.90”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.44Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 20.08 m
- To
- 209 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:20.08-209
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.44”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.2Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 223.5 m
- To
- 224 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:223.5-224
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.20”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.4Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 235 m
- To
- 236 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:235-236
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.40”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.29Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 243.5 m
- To
- 245 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:243.5-245
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.29”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 1.32Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 1.32
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 292.3 m
- To
- 292.8 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:292.3-292.8
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“1.32”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.25Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 309.9 m
- To
- 310.4 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:309.9-310.4
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.25”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.21Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 319.7 m
- To
- 320.9 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:319.7-320.9
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.21”
Context: 1.2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.32Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 319.7 m
- To
- 320.2 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:319.7-320.2
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.32”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.27Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 365 m
- To
- 365.5 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:365-365.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.27”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.22Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 391.2 m
- To
- 391.7 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:391.2-391.7
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.22”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 417.3 m
- To
- 417.8 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:417.3-417.8
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.80”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-065Ishkõday · goldGrade: 0.38Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LME25-065
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.38
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 487.4 m
- To
- 488.2 m
- Hole Depth
- 513 m
- Intercept Depth
- 5.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-065:487.4-488.2
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.38”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.21Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1.04 m
- From
- 5.46 m
- To
- 6.5 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:5.46-6.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.21”
Context: 1.04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.37Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.37
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 13.3 m
- To
- 14.75 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:13.3-14.75
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.37”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.26Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 85 m
- To
- 89 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:85-89
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.26”
Context: 4.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.53Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 86.25 m
- To
- 87.1 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:86.25-87.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.53”
Context: 0.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.67Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.67
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 117 m
- To
- 118 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:117-118
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.67”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.25Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 1.8 m
- From
- 223.7 m
- To
- 225.5 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:223.7-225.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.25”
Context: 1.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.34Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 251.5 m
- To
- 252.1 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:251.5-252.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.34”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.46Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 257.4 m
- To
- 258.15 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:257.4-258.15
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.46”
Context: 0.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 1.02Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 272.5 m
- To
- 274 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:272.5-274
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“1.02”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.41Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 303 m
- To
- 303.5 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:303-303.5
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.41”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.94Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.94
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 307.8 m
- To
- 308.3 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:307.8-308.3
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.94”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.7Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 310.2 m
- To
- 310.7 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:310.2-310.7
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.70”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.46Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 324.6 m
- To
- 325.1 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:324.6-325.1
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.46”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.93Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.93
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 327.4 m
- To
- 327.9 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:327.4-327.9
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.93”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.25Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 339 m
- To
- 340 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:339-340
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.25”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 2.42Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 2.42
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 389 m
- To
- 389.7 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:389-389.7
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow intercept with a grade that is weak for an inferred underground mining method, in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“2.42”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.84Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.84
- Grade Unit
- g/t
- Intercept
- 0.65 m
- From
- 400 m
- To
- 400.65 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:400-400.65
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.84”
Context: 0.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.21Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 413.8 m
- To
- 414.3 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:413.8-414.3
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.21”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
LME25-066Ishkõday · goldGrade: 0.2Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LME25-066
- Project
- Ishkõday
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- LME
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 465.2 m
- To
- 465.8 m
- Hole Depth
- 492 m
- Intercept Depth
- 5.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LME25-066:465.2-465.8
- Mining Method
- underground
Location
- Azimuth
- 150 °
- Dip
- -50 °
- Loc. Confidence
- high
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-25T00:00:00.000Z
Reasoning: A narrow, low-grade intercept in an exploration program with unknown true width.
Negative factors
- Apparent width only, true width not known.
- Gold grades are generally low to weak for an inferred underground mining method.
Evidence · table
“0.20”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.