Antimony Resources Corp. (CSE: ATMY) (OTCQB: ATMYF) (FSE: K8J0) Reports More Massive Antimony-bearing Stibnite (“Sb”) of 21.45% Antimony (Sb) over 1.10 meters (m) and 15.0% Sb over 0.8 m in a mineralized zone of 4.36% Sb over 13.0 m at the Main Zone.
Original announcement by cse on
- Company
- Antimony Resources Corp.
- Ticker
- ATMY
- Exchange
- CSE
- Region
- Unavailable
- Primary commodity
- Antimony
- Secondary commodities
- Gold, Arsenic
- Document categories
- Drill results, Resource update
- Extracted
- 2026-10-15 04:36:31 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Antimony Resources Corp. announced high-grade antimony drill results from its Bald Hill Antimony Project, including 21.45% Sb over 1.10m and 15.0% Sb over 0.8m within a 4.35% Sb over 13.0m mineralized zone at the Main Zone. These results extend the higher-grade mineralization towards the Central Zone and are part of a drill program aimed at infilling data gaps for a Maiden Resource Estimate. The technical content was approved by a Qualified Person, and QA/QC procedures were followed, with true widths estimated at 70-80% of intersected lengths.
Reasoning: Antimony Resources Corp. reported multiple high-grade antimony intercepts, including 21.45% Sb over 1.10m and 15.0% Sb over 0.8m within a broader 4.35% Sb over 13.0m zone, which extends mineralization towards the Central Zone and supports a future Maiden Resource Estimate. The results are strong compared to historical averages and comparable to the best historical grade-thickness, with true width estimated and QA/QC disclosed, though arsenic is present.
Positive factors
- High-grade intercepts
- Extension of mineralization
- Infill drilling for maiden resource
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Facts used in scoring: 102
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Antimony grade of 21.45% over 1.10m exceeds the exceptional threshold for antimony (>=2.5%).
Evidence · text
“21.45% Antimony (Sb) over 1.10 m”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Antimony grade of 15.0% over 0.8m exceeds the exceptional threshold for antimony (>=2.5%).
Evidence · text
“15.0% Sb over 0.8 m”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document states that true widths are estimated to be about 70% to 80% of the intersected lengths.
Evidence · text
“Note that these are intersected widths, and the true widths are estimated to be about 70% to 80% of these lengths.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release includes detailed QA/QC procedures, including standards, duplicates, blanks, and pulp duplicates, and mentions an internationally accredited laboratory.
Evidence · text
“Quality Assurance and Quality Control (QA/QC) samples are inserted in the sample runs which include a known standard for antimony and gold, a core duplicate, a blank, and a pulp duplicate. Activation Labs also has standard QA/QC protocols which are reported with each assay batch. Activation Laboratories in an internationally accredited assay Laboratory.”
QP/CP Signedpositive
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: The technical contents were reviewed and approved by Jim Atkinson, P. Geo., a qualified person as defined by NI 43-101.
Evidence · text
“The technical contents of this news release were reviewed and approved by Jim Atkinson, MSc., P. Geo., President and CEO of Antimony Resources Corp. who is a qualified person as defined by National Instrument 43-101.”
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: Arsenic is reported in the assay results, with several intervals showing high percentages.
Evidence · table
“As (%)”
Extracted facts
Stored fact records: 102. Some facts used in scoring do not have a stored record.
Drill Results (101)
BHW-26-19Bald Hill Antimony · antimonyGrade: 4.35Grade Unit: %Intercept: 13 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 4.35
- Grade Unit
- %
- Intercept
- 13 m
- True Width
- 9.75 m
- From
- 103.4 m
- To
- 116.4 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-116.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a significant width, comparable to the project's best historical grade-thickness, extending mineralization and supporting a future Maiden Resource Estimate.
Positive factors
- High-grade intercepts
- Extension of mineralization
- Infill drilling for maiden resource
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · text
“4.36% Sb over 13.0 m from 103.0 to 116.0 meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 21.45Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 21.45
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 0.825 m
- From
- 103.4 m
- To
- 104.5 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-104.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating high-grade zones within the broader mineralization, supporting future resource definition.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- Extension of mineralization
- Infill drilling for maiden resource
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · text
“21.45% Antimony (Sb) over 1.10 m”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.825
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 15Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 15
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 103.4 m
- To
- 104.2 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-104.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating high-grade zones within the broader mineralization, supporting future resource definition.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- Extension of mineralization
- Infill drilling for maiden resource
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · text
“15.0% Sb over 0.8 m”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 5.35Grade Unit: %Intercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 5.35
- Grade Unit
- %
- Intercept
- 2.8 m
- True Width
- 2.1 m
- From
- 123.4 m
- To
- 126.2 m
- Intercept Depth
- 123.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:123.4-126.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a good width, contributing to the understanding of mineralization continuity and supporting future resource definition.
Positive factors
- High-grade intercepts
- Extension of mineralization
- Infill drilling for maiden resource
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · text
“5.35% Sb over 3.45 meters from 123.4 to 126.2 meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · antimonyGrade: 2.89Grade Unit: %Intercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.89
- Grade Unit
- %
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 156.55 m
- To
- 157 m
- Intercept Depth
- 156.55 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:156.55-157
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.89”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · goldGrade: 0.193Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.193
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 156.55 m
- To
- 157 m
- Intercept Depth
- 156.55 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:156.55-157
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“193”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · arsenicGrade: 3.34Grade Unit: %Intercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 3.34
- Grade Unit
- %
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 156.55 m
- To
- 157 m
- Intercept Depth
- 156.55 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:156.55-157
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“3.34”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · antimonyGrade: 0.836Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.836
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 157 m
- To
- 158 m
- Intercept Depth
- 157 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:157-158
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.836”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · arsenicGrade: 0.01Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 157 m
- To
- 158 m
- Intercept Depth
- 157 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:157-158
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.01”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · antimonyGrade: 6.13Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 6.13
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.375 m
- From
- 158 m
- To
- 158.5 m
- Intercept Depth
- 158 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:158-158.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“6.13”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · goldGrade: 0.347Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.347
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.375 m
- From
- 158 m
- To
- 158.5 m
- Intercept Depth
- 158 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:158-158.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“347”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-16Bald Hill Antimony · arsenicGrade: 0.5Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- BHW-26-16
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.375 m
- From
- 158 m
- To
- 158.5 m
- Intercept Depth
- 158 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-16:158-158.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.5”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 13.1Grade Unit: %Intercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 13.1
- Grade Unit
- %
- Intercept
- 0.25 m
- True Width
- 0.1875 m
- From
- 55.05 m
- To
- 55.3 m
- Intercept Depth
- 55.05 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.05-55.3
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“13.1”
Context: 0.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 0.39Grade Unit: %Intercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 0.25 m
- True Width
- 0.1875 m
- From
- 55.05 m
- To
- 55.3 m
- Intercept Depth
- 55.05 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.05-55.3
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.39”
Context: 0.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 0.46Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 55.3 m
- To
- 55.9 m
- Intercept Depth
- 55.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.3-55.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.46”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.053Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.053
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 55.3 m
- To
- 55.9 m
- Intercept Depth
- 55.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.3-55.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“53”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 0.15Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 55.3 m
- To
- 55.9 m
- Intercept Depth
- 55.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.3-55.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.15”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 8.16Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 8.16
- Grade Unit
- %
- Intercept
- 0.2 m
- True Width
- 0.15 m
- From
- 55.9 m
- To
- 56.1 m
- Intercept Depth
- 55.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.9-56.1
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“8.16”
Context: 0.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.695Grade Unit: g/tIntercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.695
- Grade Unit
- g/t
- Intercept
- 0.2 m
- True Width
- 0.15 m
- From
- 55.9 m
- To
- 56.1 m
- Intercept Depth
- 55.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.9-56.1
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“695”
Context: 0.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 1.18Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.18
- Grade Unit
- %
- Intercept
- 0.2 m
- True Width
- 0.15 m
- From
- 55.9 m
- To
- 56.1 m
- Intercept Depth
- 55.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:55.9-56.1
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.18”
Context: 0.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 0.064Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.064
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 56.1 m
- To
- 56.7 m
- Intercept Depth
- 56.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.1-56.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak antimony grade over a narrow width, indicating lower-grade mineralization in this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.064”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.532Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.532
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 56.1 m
- To
- 56.7 m
- Intercept Depth
- 56.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.1-56.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“532”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 1.36Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.36
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 56.1 m
- To
- 56.7 m
- Intercept Depth
- 56.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.1-56.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.36”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 1.98Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.98
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 56.7 m
- To
- 57.25 m
- Intercept Depth
- 56.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.7-57.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.98”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.836Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.836
- Grade Unit
- g/t
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 56.7 m
- To
- 57.25 m
- Intercept Depth
- 56.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.7-57.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“836”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 1.21Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.21
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 56.7 m
- To
- 57.25 m
- Intercept Depth
- 56.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:56.7-57.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.21”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 1.72Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.72
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 57.25 m
- To
- 57.8 m
- Intercept Depth
- 57.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.25-57.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.72”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.186Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.186
- Grade Unit
- g/t
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 57.25 m
- To
- 57.8 m
- Intercept Depth
- 57.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.25-57.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“186”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 0.43Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.4125 m
- From
- 57.25 m
- To
- 57.8 m
- Intercept Depth
- 57.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.25-57.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.43”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 7.74Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 7.74
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 57.8 m
- To
- 58.2 m
- Intercept Depth
- 57.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.8-58.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“7.74”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.349Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.349
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 57.8 m
- To
- 58.2 m
- Intercept Depth
- 57.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.8-58.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“349”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 0.79Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.79
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 57.8 m
- To
- 58.2 m
- Intercept Depth
- 57.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:57.8-58.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.79”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · antimonyGrade: 0.093Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.093
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 58.2 m
- To
- 58.5 m
- Intercept Depth
- 58.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:58.2-58.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak antimony grade over a narrow width, indicating lower-grade mineralization in this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.093”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · goldGrade: 0.008Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.008
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 58.2 m
- To
- 58.5 m
- Intercept Depth
- 58.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:58.2-58.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“8”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-18Bald Hill Antimony · arsenicGrade: 0.04Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-18
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 58.2 m
- To
- 58.5 m
- Intercept Depth
- 58.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-18:58.2-58.5
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.04”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 1.52Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.52
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 103.4 m
- To
- 103.8 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-103.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.52”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.876Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.876
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 103.4 m
- To
- 103.8 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-103.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“876”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.3Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.3
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 103.4 m
- To
- 103.8 m
- Intercept Depth
- 103.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.4-103.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.3”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 32.2Grade Unit: %Intercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 32.2
- Grade Unit
- %
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 103.8 m
- To
- 104.25 m
- Intercept Depth
- 103.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.8-104.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating a very high-grade zone within the mineralization.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“32.20”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.778Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.778
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 103.8 m
- To
- 104.25 m
- Intercept Depth
- 103.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.8-104.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“778”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.23Grade Unit: %Intercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.23
- Grade Unit
- %
- Intercept
- 0.45 m
- True Width
- 0.3375 m
- From
- 103.8 m
- To
- 104.25 m
- Intercept Depth
- 103.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:103.8-104.25
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.23”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 14Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 14
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 104.25 m
- To
- 104.9 m
- Intercept Depth
- 104.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.25-104.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating a very high-grade zone within the mineralization.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“14.00”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.567Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.567
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 104.25 m
- To
- 104.9 m
- Intercept Depth
- 104.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.25-104.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“567”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.52Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.52
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 104.25 m
- To
- 104.9 m
- Intercept Depth
- 104.25 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.25-104.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.52”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 1.37Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.37
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 104.9 m
- To
- 105.9 m
- Intercept Depth
- 104.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.9-105.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.37”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.269Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.269
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 104.9 m
- To
- 105.9 m
- Intercept Depth
- 104.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.9-105.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“269”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.22Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.22
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 104.9 m
- To
- 105.9 m
- Intercept Depth
- 104.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:104.9-105.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.22”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 2.21Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.21
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 105.9 m
- To
- 106.9 m
- Intercept Depth
- 105.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:105.9-106.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.21”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.558Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.558
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 105.9 m
- To
- 106.9 m
- Intercept Depth
- 105.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:105.9-106.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“558”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 2.71Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.71
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 105.9 m
- To
- 106.9 m
- Intercept Depth
- 105.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:105.9-106.9
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.71”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 3.41Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 3.41
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 106.9 m
- To
- 107.2 m
- Intercept Depth
- 106.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:106.9-107.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“3.41”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 1.08Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 106.9 m
- To
- 107.2 m
- Intercept Depth
- 106.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:106.9-107.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1080”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.98Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.98
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.225 m
- From
- 106.9 m
- To
- 107.2 m
- Intercept Depth
- 106.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:106.9-107.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.98”
Context: 0.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.225
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 1.82Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.82
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 107.2 m
- To
- 108 m
- Intercept Depth
- 107.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:107.2-108
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.82”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.539Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.539
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 107.2 m
- To
- 108 m
- Intercept Depth
- 107.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:107.2-108
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“539”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.08Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.08
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 107.2 m
- To
- 108 m
- Intercept Depth
- 107.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:107.2-108
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.08”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 6.15Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 6.15
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 108 m
- To
- 109 m
- Intercept Depth
- 108 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:108-109
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“6.15”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 1.64Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.64
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 108 m
- To
- 109 m
- Intercept Depth
- 108 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:108-109
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong gold grade, indicating a potentially valuable byproduct, and contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1640”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 5.1Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 5.1
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 108 m
- To
- 109 m
- Intercept Depth
- 108 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:108-109
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Very high arsenic grade, indicating a significant deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“5.1”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 15Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 15
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 109 m
- To
- 109.65 m
- Intercept Depth
- 109 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109-109.65
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating a very high-grade zone within the mineralization.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“15.00”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 1.15Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.15
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 109 m
- To
- 109.65 m
- Intercept Depth
- 109 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109-109.65
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1150”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 3.31Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 3.31
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.4875 m
- From
- 109 m
- To
- 109.65 m
- Intercept Depth
- 109 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109-109.65
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“3.31”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.52Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.52
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 109.65 m
- To
- 110.45 m
- Intercept Depth
- 109.65 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109.65-110.45
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.52”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.531Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.531
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 109.65 m
- To
- 110.45 m
- Intercept Depth
- 109.65 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109.65-110.45
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“531”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.61Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.61
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 109.65 m
- To
- 110.45 m
- Intercept Depth
- 109.65 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:109.65-110.45
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.61”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 5.39Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 5.39
- Grade Unit
- %
- Intercept
- 0.95 m
- True Width
- 0.7125 m
- From
- 110.45 m
- To
- 111.4 m
- Intercept Depth
- 110.45 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:110.45-111.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“5.39”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.46Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.7125 m
- From
- 110.45 m
- To
- 111.4 m
- Intercept Depth
- 110.45 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:110.45-111.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“460”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 2.41Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.41
- Grade Unit
- %
- Intercept
- 0.95 m
- True Width
- 0.7125 m
- From
- 110.45 m
- To
- 111.4 m
- Intercept Depth
- 110.45 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:110.45-111.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.41”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7125
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 3.19Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 3.19
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 111.4 m
- To
- 112.4 m
- Intercept Depth
- 111.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:111.4-112.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“3.19”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.46Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 111.4 m
- To
- 112.4 m
- Intercept Depth
- 111.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:111.4-112.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“460”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.69Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 111.4 m
- To
- 112.4 m
- Intercept Depth
- 111.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:111.4-112.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.69”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.56Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.56
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 112.4 m
- To
- 113.4 m
- Intercept Depth
- 112.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:112.4-113.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.56”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.491Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.491
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 112.4 m
- To
- 113.4 m
- Intercept Depth
- 112.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:112.4-113.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“491”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.43Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.43
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 112.4 m
- To
- 113.4 m
- Intercept Depth
- 112.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:112.4-113.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.43”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.58Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.58
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 113.4 m
- To
- 114.4 m
- Intercept Depth
- 113.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:113.4-114.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.58”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.414Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.414
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 113.4 m
- To
- 114.4 m
- Intercept Depth
- 113.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:113.4-114.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“414”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.45Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.45
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 113.4 m
- To
- 114.4 m
- Intercept Depth
- 113.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:113.4-114.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.45”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.42Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.42
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 114.4 m
- To
- 115.4 m
- Intercept Depth
- 114.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:114.4-115.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.42”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.084Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.084
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 114.4 m
- To
- 115.4 m
- Intercept Depth
- 114.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:114.4-115.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“84”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.28Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 114.4 m
- To
- 115.4 m
- Intercept Depth
- 114.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:114.4-115.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.28”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.08Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 115.4 m
- To
- 116.4 m
- Intercept Depth
- 115.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:115.4-116.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak antimony grade over a moderate width, indicating lower-grade mineralization in this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.08”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.316Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.316
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 115.4 m
- To
- 116.4 m
- Intercept Depth
- 115.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:115.4-116.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“316”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.56Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.56
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 115.4 m
- To
- 116.4 m
- Intercept Depth
- 115.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:115.4-116.4
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.56”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.32Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 123.4 m
- To
- 124.2 m
- Intercept Depth
- 123.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:123.4-124.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.32”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.145Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.145
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 123.4 m
- To
- 124.2 m
- Intercept Depth
- 123.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:123.4-124.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“145”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.46Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.6 m
- From
- 123.4 m
- To
- 124.2 m
- Intercept Depth
- 123.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:123.4-124.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.46”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 21Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 21
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 124.2 m
- To
- 124.8 m
- Intercept Depth
- 124.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.2-124.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Exceptional antimony grade over a narrow width, indicating a very high-grade zone within the mineralization.
Positive factors
- Bonanza Intercept
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“21.00”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 1.09Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.09
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 124.2 m
- To
- 124.8 m
- Intercept Depth
- 124.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.2-124.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1090”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 1.74Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 1.74
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.45 m
- From
- 124.2 m
- To
- 124.8 m
- Intercept Depth
- 124.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.2-124.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: High arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“1.74”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.45
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 2.02Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.02
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 124.8 m
- To
- 125.8 m
- Intercept Depth
- 124.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.8-125.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.02”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.61Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 124.8 m
- To
- 125.8 m
- Intercept Depth
- 124.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.8-125.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“610”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.61Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.61
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 124.8 m
- To
- 125.8 m
- Intercept Depth
- 124.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:124.8-125.8
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.61”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.25Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 125.8 m
- To
- 126.2 m
- Intercept Depth
- 125.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:125.8-126.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak antimony grade over a narrow width, indicating lower-grade mineralization in this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.25”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.027Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.027
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 125.8 m
- To
- 126.2 m
- Intercept Depth
- 125.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:125.8-126.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“27”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.03Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 125.8 m
- To
- 126.2 m
- Intercept Depth
- 125.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:125.8-126.2
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.03”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 0.21Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.21
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 130.3 m
- To
- 131.3 m
- Intercept Depth
- 130.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:130.3-131.3
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak antimony grade over a moderate width, indicating lower-grade mineralization in this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.21”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.014Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.014
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 130.3 m
- To
- 131.3 m
- Intercept Depth
- 130.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:130.3-131.3
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“14”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.02Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.75 m
- From
- 130.3 m
- To
- 131.3 m
- Intercept Depth
- 130.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:130.3-131.3
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Low arsenic grade, indicating minimal deleterious impact for this interval.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.02”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · antimonyGrade: 2.45Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 2.45
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 131.3 m
- To
- 131.7 m
- Intercept Depth
- 131.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:131.3-131.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Strong antimony grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- High-grade intercepts
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“2.45”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · goldGrade: 0.29Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- gold
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 131.3 m
- To
- 131.7 m
- Intercept Depth
- 131.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:131.3-131.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Weak gold grade, likely a byproduct, but contributes to the overall understanding of the polymetallic nature of the deposit.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“290”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
BHW-26-19Bald Hill Antimony · arsenicGrade: 0.33Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- BHW-26-19
- Project
- Bald Hill Antimony
- Commodity
- arsenic
- Region
- canada_nb
- Reported Region
- canada_nb
- Ticker
- ATMY
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 131.3 m
- To
- 131.7 m
- Intercept Depth
- 131.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- BHW-26-19:131.3-131.7
- Mining Method
- unknown
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Labs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: Moderate arsenic grade, indicating a potential deleterious element that could impact processing or concentrate quality.
Positive factors
- QP/CP Signed
- QA/QC Disclosed
- True Width Disclosed
Negative factors
- Deleterious Elements Present
Evidence · table
“0.33”
Context: 0.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Resource Estimates (1)
inferredBald Hill Antimony Project · antimonyTonnes: 2700000Grade: 3.5Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Bald Hill Antimony Project
- Commodity
- antimony
- Region
- canada_nb
- Reported Region
- New Brunswick, Canada
- Ticker
- ATMY
Resource scope
- Estimate type
- resource
- Reporting standards
- ni_43_101
- QP Signed
- Yes
- Qualified person names
- John Langton
- Resource group id
- resource:9e0857ec8d80c1ec7695
- Deposit or zone
- Main Zone
Resource Data
- Category
- inferred
- Tonnes
- 2700000
- Grade
- 3.5
- Grade Unit
- %
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-03-02T00:00:00.000Z
Dates
- Event date
- 2026-10-15T00:00:00.000Z
Reasoning: This is a historical and conceptual estimate, not a current resource, and is entirely in the inferred category, limiting its economic confidence.
Negative factors
- Historical Estimate Only
- All Inferred
Evidence · text
“approximately 2.7 million tonnes with a grade between 3% and 4% antimony”
Tags used in scoring
Inferred Resourcenegative
Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.
Why it applies: category is "inferred"
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
QP/CP Signedpositive
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: qp_signed is true
NI 43-101 Compliantpositive
Resource estimate prepared in compliance with NI 43-101 (Canada) — high reporting standard.
Why it applies: reporting_standards includes ni_43_101
No Contained Metalnegative
Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.
Why it applies: contained_metal was not reported
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.