Antimony Resources Corp. (CSE: ATMY) (OTCQB: ATMYF) (FSE: K8J0) Reports High-Grade Antimony (Sb) Assays – Drills 27.3 % Sb over 0.3 meters (m) within a zone of 2.28% Sb over a length of 9.12 m

Original announcement by cse on

Company
Antimony Resources Corp.
Ticker
ATMY
Exchange
CSE
Region
New Brunswick
Primary commodity
Antimony
Secondary commodities
Gold
Document categories
Drill results
Extracted
2026-09-30 16:49:50 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Antimony Resources Corp. announced high-grade antimony and gold assay results from its Bald Hill Antimony Project in New Brunswick, Canada. Drilling in the Main Zone returned 27.3% antimony over 0.3 meters within a wider zone of 2.28% antimony over 9.12 meters, with associated gold. Initial drilling in the newly identified Central Zone also confirmed antimony mineralization, including 10.3% antimony over 0.4 meters within 2.63% antimony over 2.2 meters, marking a significant step in expanding the project's resource potential.

Reasoning: The announcement reports a bonanza-grade antimony intercept in the Main Zone and confirms significant mineralization in the newly identified Central Zone, indicating potential for resource expansion. While some wider intercepts show lower grades than prior averages, the overall program advances understanding of the deposit, supported by robust QA/QC.

Positive factors

  • High-grade antimony intercept
  • Discovery of new mineralization in Central Zone
  • Drilling aimed at expanding Main Zone mineralization and infilling data gaps
  • Comprehensive QA/QC disclosure and certified laboratory

Negative factors

  • Wider intercepts in Main Zone show lower antimony grades compared to historical averages
  • True width is estimated as a range rather than precisely stated for each interval

Facts used in scoring: 23

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept of 27.3% Sb over 0.3m is an exceptionally high-grade zone for antimony, well above typical deposit norms.

Evidence · text

“27.3 % Sb over 0.3 meters (m)”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section mentioning certified lab, QP sign-off, and specific methods like blanks, standards, duplicates, and pulp duplicates.

Evidence · text

“Quality Assurance and Quality Control (QA/QC) samples are inserted in the sample runs which include a known standard for antimony and gold, a core duplicate, a blank, and a pulp duplicate. Activation Labs also has standard QA/QC protocols which are reported with each assay batch. Activation Laboratories in an internationally accredited assay Laboratory.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: Drilling in the Central Zone is described as a 'preliminary test of the mineralization below the surface trenches' in a newly identified zone, extending mineralization beyond previously drilled areas.

Evidence · text

“Drilling is being completed on the newly identified Central zone where trenching by ATMY and previous operators has identified antimony-bearing stibnite mineralization. ... our current program will be a preliminary test of the mineralization below the surface trenches.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Drilling in the Main Zone is explicitly stated as 'focusing on in-filling gaps in the data by intersecting areas where there was little or no drill information'.

Evidence · text

“The drilling has been focusing on in-filling gaps in the data by intersecting areas where there was little or no drill information to attempt to develop a more detailed picture of the deposit.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document states that true widths are 'estimated to be about 70% to 80% of these lengths' rather than providing precise true widths for each interval, indicating that the reported lengths are primarily downhole.

Evidence · text

“Note that these are intersected widths, and the true widths are estimated to be about 70% to 80% of these lengths.”

Extracted facts

Stored fact records: 23. Some facts used in scoring do not have a stored record.

Drill Results (23)

BH-26-21Bald Hill Antimony · antimonyGrade: 2.28Grade Unit: %Intercept: 9.12 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
2.28
Grade Unit
%
Intercept
9.12 m
True Width
6.84 m
From
144.38 m
To
153.5 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:144.38-153.5

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This intercept provides a good width of antimony mineralization, contributing to the understanding and potential expansion of the Main Zone, although the grade is lower than the project's historical average.

Positive factors

  • Good intercept length for antimony
  • Contributes to resource expansion in Main Zone

Negative factors

  • Antimony grade is below the project's prior average
  • True width is an estimate (70-80% of downhole length)

Evidence · text

“2.28% Sb over a length of 9.12 m from 144.38 to 153.5 m depth”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · goldGrade: 0.93Grade Unit: g/tIntercept: 9.12 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.93
Grade Unit
g/t
Intercept
9.12 m
True Width
6.84 m
From
144.38 m
To
153.5 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:144.38-153.5

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept, while a byproduct, adds to the overall mineralization profile of the Main Zone, though the grade is below the project's historical average for gold.

Positive factors

  • Good intercept length for gold byproduct

Negative factors

  • Gold grade is below the project's prior average
  • True width is an estimate (70-80% of downhole length)

Evidence · text

“The corresponding gold assay is 0.93 g/t over the same width”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · antimonyGrade: 27.3Grade Unit: %Intercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
27.3
Grade Unit
%
Intercept
0.3 m
True Width
0.225 m
From
144.38 m
To
144.68 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:144.38-144.68

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This bonanza-grade antimony intercept is highly significant, demonstrating the presence of very high-grade mineralization within the Main Zone, despite its narrow width.

Positive factors

  • Exceptional high-grade antimony intercept (Bonanza Intercept)
  • Significantly above project's prior average grade
  • Confirms presence of very high-grade mineralization

Negative factors

  • Very narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · text

“27.3 % Sb over 0.3 meters (m) within a zone of 2.28% Sb over a length of 9.12 m”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.225

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · goldGrade: 0.68Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.68
Grade Unit
g/t
Intercept
0.3 m
True Width
0.225 m
From
144.38 m
To
144.68 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:144.38-144.68

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This narrow gold intercept is of low grade and contributes minimally to the overall prospectivity, though it is associated with a bonanza antimony intercept.

Negative factors

  • Low gold grade for a narrow intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.68”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.225

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · antimonyGrade: 1.9Grade Unit: %Intercept: 5.2 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
1.9
Grade Unit
%
Intercept
5.2 m
True Width
3.9 m
From
159.8 m
To
165 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:159.8-165

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This intercept provides a good width of antimony mineralization, supporting infill efforts in the Main Zone, though the grade is below the project's historical average.

Positive factors

  • Good intercept length for antimony
  • Contributes to infill drilling in Main Zone

Negative factors

  • Antimony grade is below the project's prior average
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“1.90”

Context: 5.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · goldGrade: 0.19Grade Unit: g/tIntercept: 5.2 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
5.2 m
True Width
3.9 m
From
159.8 m
To
165 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:159.8-165

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of low grade and contributes minimally to the overall prospectivity of the Main Zone.

Negative factors

  • Low gold grade for a wider intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.19”

Context: 5.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · antimonyGrade: 9.05Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
9.05
Grade Unit
%
Intercept
0.55 m
True Width
0.4125 m
From
161.6 m
To
162.15 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:161.6-162.15

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This high-grade antimony sub-interval is positive, indicating localized high-grade mineralization within the broader Main Zone, despite its narrowness.

Positive factors

  • High-grade antimony intercept

Negative factors

  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“9.05”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4125

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · goldGrade: 0.085Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.085
Grade Unit
g/t
Intercept
0.55 m
True Width
0.4125 m
From
161.6 m
To
162.15 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:161.6-162.15

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.085”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4125

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · antimonyGrade: 3.05Grade Unit: %Intercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
3.05
Grade Unit
%
Intercept
0.85 m
True Width
0.6375 m
From
164.15 m
To
165 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:164.15-165

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This intercept shows a good antimony grade over a narrow width, contributing to the understanding of mineralization within the Main Zone.

Positive factors

  • Good antimony grade

Negative factors

  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“3.05”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6375

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-19Bald Hill Antimony · goldGrade: 0.965Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
BH-26-19
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.965
Grade Unit
g/t
Intercept
0.85 m
True Width
0.6375 m
From
164.15 m
To
165 m
Intercept Depth
159.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-19:164.15-165

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of moderate grade over a narrow width, providing some byproduct potential.

Negative factors

  • Moderate gold grade for a narrow intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.965”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6375

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · goldGrade: 3.66Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
3.66
Grade Unit
g/t
Intercept
1 m
True Width
0.75 m
From
152.5 m
To
153.5 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:152.5-153.5

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This high-grade gold intercept is positive, exceeding the project's prior average and indicating localized high-grade gold mineralization within the Main Zone.

Positive factors

  • High-grade gold intercept
  • Above project's prior average gold grade

Negative factors

  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“3.66”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · antimonyGrade: 0.95Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.95
Grade Unit
%
Intercept
1 m
True Width
0.75 m
From
152.5 m
To
153.5 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:152.5-153.5

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This antimony intercept is of low grade and narrow, contributing minimally to the overall prospectivity, though it is associated with a high-grade gold intercept.

Negative factors

  • Low antimony grade for a narrow intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.95”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · antimonyGrade: 0.94Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.94
Grade Unit
%
Intercept
0.8 m
True Width
0.6 m
From
155.4 m
To
156.2 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:155.4-156.2

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This antimony intercept is of low grade and narrow, contributing minimally to the overall prospectivity of the Main Zone.

Negative factors

  • Low antimony grade for a narrow intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.94”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BH-26-21Bald Hill Antimony · goldGrade: 1.22Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
BH-26-21
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
1.22
Grade Unit
g/t
Intercept
0.8 m
True Width
0.6 m
From
155.4 m
To
156.2 m
Intercept Depth
144.38 m

Classification

Program
mixed
Sample Type
drill
Group ID
BH-26-21:155.4-156.2

Location

Location
Main Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of moderate grade over a narrow width, providing some byproduct potential.

Negative factors

  • Moderate gold grade for a narrow intercept
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“1.22”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

BHC-26-01Bald Hill Antimony · antimonyGrade: 2.63Grade Unit: %Intercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
2.63
Grade Unit
%
Intercept
2.2 m
True Width
1.65 m
From
118.8 m
To
121 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:118.8-121

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This intercept is significant as it confirms antimony mineralization in the previously undrilled Central Zone, indicating new exploration potential, despite the grade being below the project's historical average.

Positive factors

  • Confirms antimony mineralization in a newly identified zone (Central Zone)
  • Good antimony grade over a moderate width

Negative factors

  • Antimony grade is below the project's prior average
  • True width is an estimate (70-80% of downhole length)

Evidence · text

“2.63% Sb over 2.2 meters from 118.8 to 121.0 depth”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.65

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · antimonyGrade: 10.3Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
10.3
Grade Unit
%
Intercept
0.4 m
True Width
0.3 m
From
120.6 m
To
121 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:120.6-121

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This high-grade antimony sub-interval is a strong positive, confirming significant mineralization in the newly identified Central Zone and indicating potential for high-grade shoots.

Positive factors

  • High-grade antimony intercept in a new zone
  • Significantly above project's prior average grade for antimony

Negative factors

  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · text

“10.3% Sb in a section of 2.63% Sb over 2.2 meters”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · antimonyGrade: 0.32Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
antimony
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.32
Grade Unit
%
Intercept
2.1 m
True Width
1.575 m
From
114.8 m
To
116.8 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:114.8-116.8

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This intercept confirms the presence of antimony mineralization in the Central Zone, but at a low grade, suggesting broader but less concentrated mineralization.

Positive factors

  • Confirms antimony mineralization in a new zone

Negative factors

  • Low antimony grade
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“0.32”

Context: 2.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.575

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.083Grade Unit: g/tIntercept: 0.73 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.083
Grade Unit
g/t
Intercept
0.73 m
True Width
0.5475 m
From
114.07 m
To
114.8 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:114.07-114.8

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“83”

Context: 0.73

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5475

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.072Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.072
Grade Unit
g/t
Intercept
1 m
True Width
0.75 m
From
114.8 m
To
115.8 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:114.8-115.8

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“72”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.04Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
0.8 m
True Width
0.6 m
From
118.8 m
To
119.6 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:118.8-119.6

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“40”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.074Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.074
Grade Unit
g/t
Intercept
0.6 m
True Width
0.45 m
From
119.6 m
To
120.2 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:119.6-120.2

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“74”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.45

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.088Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.088
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
120.2 m
To
120.6 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:120.2-120.6

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“88”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

BHC-26-01Bald Hill Antimony · goldGrade: 0.033Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
BHC-26-01
Project
Bald Hill Antimony
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
ATMY

Geometry

Grade
0.033
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
120.6 m
To
121 m
Intercept Depth
112.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BHC-26-01:120.6-121

Location

Location
Central Zone
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: This gold intercept is of very low grade and narrow, contributing negligibly to the overall prospectivity of the Central Zone.

Negative factors

  • Very low gold grade
  • Narrow intercept length
  • True width is an estimate (70-80% of downhole length)

Evidence · table

“33”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.