# Andina Copper Drills New Porphyry Copper System at Piuquenes North

Canonical Atlas analysis: https://atlas-staging.minestarters.com/news/andina-copper-drills-new-porphyry-copper-system-at-piuquenes-north--e8bf72c0-40d1-4e75-9a8a-65e41c747492

Original source: https://money.tmx.com/en/quote/ANDC/news/5162108106246492/andina-copper-drills-new-porphyry-copper-system-at-piuquenes-north

Publisher: tmx

Original announcement: 2026-05-28T10:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Andina Copper Corp.

- Ticker: ANDC

- Exchange: TSX

- Region: San Juan Province, Argentina

- Primary commodity: Copper

- Secondary commodities: Gold

- Document categories: Drill results, Other

- Extracted: 2026-08-22 22:32:46 UTC

Narrative sentiment: 0.60 · Bullish

## Minestarters Atlas summary

Andina Copper has completed two drill holes \(PIU12 and PIU13\) at the Piuquenes North target, confirming a multiphase porphyry copper system. The drilling successfully intersected the targeted Magnetotelluric \(MT\) geophysical anomaly, with visible chalcopyrite and bornite mineralization observed. Assay results are currently pending.

Reasoning: The announcement confirms the discovery of a new porphyry copper system at a previously untested target, successfully validating a geophysical anomaly, though actual grades are not yet available.

- Positive factor: Confirmation of porphyry system at new target

- Positive factor: Successful testing of MT geophysical anomaly

- Positive factor: Presence of chalcopyrite and bornite observed visually

- Negative factor: Assay results are pending

- Negative factor: No numeric grades reported

- Negative factor: Visual logging only

Facts used in scoring: 2

## Classification and evidence

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: The release details a QA/QC program including certified reference materials, blanks, and duplicates.

Evidence · text

> The Company implemented a quality assurance and quality control \(QA/QC\) program that included the insertion of certified reference materials, blanks, and duplicates

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: Not applicable as QA/QC is disclosed, but the lack of assay results is a notable limitation.

Evidence · text

> Assay results for both PIU12 and PIU13 are pending.

## Extracted facts

Stored fact records: 2. Some facts used in scoring do not have a stored record.

## Drill Results (2)

### PIU13

[Link to this fact](https://atlas-staging.minestarters.com/news/andina-copper-drills-new-porphyry-copper-system-at-piuquenes-north--e8bf72c0-40d1-4e75-9a8a-65e41c747492#fact-drill-facts-0)

Piuquenes North · copper

#### Identity

- Hole ID: PIU13
- Project: Piuquenes North
- Commodity: copper
- Region: argentina
- Reported Region: San Juan Province, Argentina
- Ticker: ANDC

#### Geometry

- Hole Depth: 1235 m

#### Classification

- Deposit Type: porphyry
- Program: exploration
- Sample Type: drill
- Mining Method: unknown

#### Location

- Azimuth: 50 °
- Dip: -70 °

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-28T00:00:00.000Z

Reasoning: Hole intersected porphyry-style mineralization within a new target, but no assay grades are provided.

- Positive factor: Confirmed porphyry system at new target

- Negative factor: Assays pending

- Negative factor: Visual logging only

Evidence · text

> Hole PIU13 intersected four porphyry intrusive phases, confirming the presence of a well-developed porphyry system

### PIU12

[Link to this fact](https://atlas-staging.minestarters.com/news/andina-copper-drills-new-porphyry-copper-system-at-piuquenes-north--e8bf72c0-40d1-4e75-9a8a-65e41c747492#fact-drill-facts-1)

Piuquenes North · copper

#### Identity

- Hole ID: PIU12
- Project: Piuquenes North
- Commodity: copper
- Region: argentina
- Reported Region: San Juan Province, Argentina
- Ticker: ANDC

#### Geometry

- Hole Depth: 992.6 m

#### Classification

- Deposit Type: porphyry
- Program: exploration
- Sample Type: drill
- Mining Method: unknown

#### Location

- Azimuth: 255 °
- Dip: -70 °

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-28T00:00:00.000Z

Reasoning: Hole confirmed the lateral extent of the porphyry system, but no assay grades are provided.

- Positive factor: Confirmed lateral continuity of porphyry system

- Negative factor: Assays pending

- Negative factor: Visual logging only

Evidence · text

> PIU12 confirmed the lateral extent of the porphyry system

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
