Americas Gold & Silver Corp - EX-99.1 (2026-09-18)

Original announcement by sec_edgar on

Company
Americas Gold and Silver Corporation
Ticker
USAS
Exchange
NYSE
Region
Idaho
Primary commodity
Silver
Secondary commodities
Copper, Lead, Antimony
Document categories
Drill results
Extracted
2026-10-01 07:30:30 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Americas Gold and Silver Corporation announced high-grade drill results from its Galena Complex, including new vein discoveries at the Galena and Crescent Mines. The drilling, part of the company's largest-ever exploration and resource conversion program, returned exceptional silver, copper, lead, and antimony intercepts, with some exceeding currently modeled grades. These results are expected to significantly enhance future mine plans and are supported by comprehensive QA/QC procedures.

Reasoning: Americas Gold and Silver reported exceptional high-grade silver, copper, lead, and antimony drill results from its Galena Complex, including new vein discoveries and significant extensions of known mineralization, which are expected to positively impact future mine plans. The results are supported by comprehensive QA/QC.

Positive factors

  • High-grade intercepts across multiple commodities (Ag, Cu, Pb, Sb)
  • Discovery of new high-grade veins at both Galena and Crescent Mines
  • Significant extension of existing veins, expanding mineralized footprint
  • Infill drilling regularly intersecting higher silver grades than currently modeled
  • Robust QA/QC procedures including ISO-17025 accredited labs and QP sign-off
  • True width disclosed for all tabular intercepts

Negative factors

  • Some intercepts have very narrow true widths, which may impact mineability

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 125

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Multiple silver intercepts exceed the 500 g/t exceptional threshold, including 20,124 g/t Ag, 9,611 g/t Ag, and 7,123 g/t Ag.

Evidence · text

“1,062 G/T AG, 0.7% CU OVER 1.3 METERS”

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: Both tables explicitly state 'True Width (m)' for all reported intercepts.

Evidence · table

“True Width (m)”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The drilling program is described as 'exploration drilling' and mentions 'significantly extending existing major veins' and 'expanding the 2025 discovery to 200m along strike and 200m in vertical extent'.

Evidence · text

“significantly extending existing major veins on multiple levels of the mine. I'd like to congratulate the entire Galena team for their hard work and exceptional safety record as we continue to identify new targets to feed the mine's significant future. Our recent drilling across the Galena Complex has continued to deliver exceptional results. The new vein discovery on the operating 49 level (49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb) is not only high grade, but also very close to our minimum mining width for our ongoing transition to long hole stoping. The high-grade discovery of the 9 Vein (24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb) in an area without any vein projections is a typical example of the numerous opportunities for new discoveries at Galena, even in higher levels with significant historical mining. Moving over to Coeur, the 520 Vein system continues to grow, with recent drilling expanding the 2025 discovery to 200m along strike and 200m in vertical extent while all directions remain open for further expansion.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details QA/QC practices, including the use of certified reference materials, field duplicates, blanks, and independent ISO-17025 accredited laboratories (AAS, SVL, ALS Global), with sign-off by a Qualified Person.

Evidence · text

“The Company's standard QA/QC practices were utilized to ensure the integrity of the core and sample preparation at the Galena Complex through delivery of the samples to the assay lab. The drill core was stored in a secure facility, photographed, logged and sampled based on lithologic and mineralogical interpretations. Standards of certified reference materials, field duplicates and blanks were inserted as samples shipped with the core samples to the lab. Analytical work was carried out by American Analytical Services Inc. ("AAS") located in Osburn, Idaho, or SVL Analytical located in Kellogg Idaho. AAS and SVL are independent, ISO-17025 accredited laboratories. Sample preparation includes a 30-gram pulp sample analyzed by atomic absorption spectrometry ("AA") techniques to determine silver, copper, and lead, using aqua regia for pulp digestion. Samples returning values over 514 g/t Ag are re-assayed using fire-assay techniques for silver. Additionally, samples returning values over 23% Pb are re-assayed using titration techniques. Duplicate pulp samples are sent out quarterly to ALS Global, an independent, ISO-17025 accredited laboratory based in Reno, Nevada to perform an independent check analysis. A conventional AA technique was used for the analysis of silver, copper and lead at ALS Global with the same industry standard procedures as those used by AAS. The assay results listed in this report did not show any significant contamination during sample preparation or sample bias of analysis.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The program is explicitly described as 'substantial infill and step-out exploration drilling' and aims to 'infill drill the existing Mineral Resource at Alhambra and South Veins'.

Evidence · text

“The assays reported today are a result of substantial infill and step-out exploration drilling conducted across multiple target areas at the Galena, Coeur (see Figure 1), and Crescent (see Figure 2) mines.”

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: Antimony (Sb) and Lead (Pb) are reported in significant percentages in many intercepts, which can be penalty elements.

Evidence · text

“high-grade Ag-Cu-Pb-Sb drill results”

New Vein Discoverypositive · Story-specific tag

No canonical definition is currently available.

Why it applies: The release highlights 'new vein discoveries at Galena and Crescent' and 'discovery of two new veins in the vicinity of Alhambra'.

Evidence · text

“Drilling has delivered new vein discoveries at Galena and Crescent as well returned infill drill intercepts that are regularly intersecting higher silver grades than the currently modeled Mineral Resource.”

Extracted facts

Stored fact records: 125. Some facts used in scoring do not have a stored record.

Drill Results (125)

Fact 1Galena Mine · silverGrade: 1062Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1062
Grade Unit
g/t
Intercept
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept from a new vein discovery at the Galena Mine.

Positive factors

  • Bonanza Intercept
  • New Vein Discovery

Evidence · text

“new Galena Mine vein discovery grading 1,062 g/t Ag, 0.7% Cu over 1.3 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 2Galena Mine · copperGrade: 0.7Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
Intercept
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper grade from a new vein discovery at the Galena Mine.

Positive factors

  • New Vein Discovery

Evidence · text

“new Galena Mine vein discovery grading 1,062 g/t Ag, 0.7% Cu over 1.3 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 3Crescent Mine · silverGrade: 1891Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1891
Grade Unit
g/t
Intercept
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept from Crescent drilling.

Positive factors

  • Bonanza Intercept

Evidence · text

“Crescent drilling returns 1,891 g/t Ag, 0.3% Cu over 1.3 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 4Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
Intercept
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept from Crescent drilling.

Evidence · text

“Crescent drilling returns 1,891 g/t Ag, 0.3% Cu over 1.3 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 5Crescent Mine · silverGrade: 1560Grade Unit: g/tIntercept: 1.1 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1560
Grade Unit
g/t
Intercept
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept from Crescent drilling.

Positive factors

  • Bonanza Intercept

Evidence · text

“1,560 g/t Ag, 0.3% Cu over 1.1 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Fact 6Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.1 mNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
Intercept
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept from Crescent drilling.

Evidence · text

“1,560 g/t Ag, 0.3% Cu over 1.1 meters”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-817Galena Mine · silverGrade: 1061Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
49-817
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1061
Grade Unit
g/t
Intercept
1.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept from a new vein discovery on the 49 level of the Galena Mine.

Positive factors

  • Bonanza Intercept
  • New Vein Discovery

Evidence · text

“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-817Galena Mine · copperGrade: 0.7Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
49-817
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
Intercept
1.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper grade from a new vein discovery on the 49 level of the Galena Mine.

Positive factors

  • New Vein Discovery

Evidence · text

“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-817Galena Mine · antimonyGrade: 0.6Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
49-817
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.6
Grade Unit
%
Intercept
1.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony grade from a new vein discovery on the 49 level of the Galena Mine.

Positive factors

  • New Vein Discovery

Evidence · text

“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

24-407Galena Mine · silverGrade: 7123Grade Unit: g/tIntercept: 0.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
24-407
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
7123
Grade Unit
g/t
Intercept
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept from the new 9 Vein discovery at the Galena Mine.

Positive factors

  • Bonanza Intercept
  • New Vein Discovery

Evidence · text

“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

24-407Galena Mine · copperGrade: 3.24Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
24-407
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3.24
Grade Unit
%
Intercept
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade copper intercept from the new 9 Vein discovery at the Galena Mine.

Positive factors

  • New Vein Discovery

Evidence · text

“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

24-407Galena Mine · antimonyGrade: 1.81Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
24-407
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.81
Grade Unit
%
Intercept
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade antimony intercept from the new 9 Vein discovery at the Galena Mine.

Positive factors

  • New Vein Discovery

Evidence · text

“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · silverGrade: 1284.6Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1284.6
Grade Unit
g/t
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,284.6”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · copperGrade: 0.9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.9
Grade Unit
%
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.9”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · leadGrade: 0.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.7”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · silverGrade: 3608Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3608
Grade Unit
g/t
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“3,608.0”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · copperGrade: 3.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3.1
Grade Unit
%
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“3.1”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · leadGrade: 2.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.6
Grade Unit
%
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.6”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · silverGrade: 3054.4Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3054.4
Grade Unit
g/t
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“3,054.4”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · copperGrade: 2.8Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.8
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.8”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-336Galena Mine · leadGrade: 2.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-336
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.1
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.1”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · silverGrade: 1573.8Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1573.8
Grade Unit
g/t
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,573.8”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · copperGrade: 1.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.3
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.3”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · antimonyGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.1”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · leadGrade: 1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.0”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · silverGrade: 806Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
806
Grade Unit
g/t
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“806.0”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · copperGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.8
Grade Unit
%
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.8”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · antimonyGrade: 0.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.6
Grade Unit
%
True Width
0.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.6”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · silverGrade: 9611Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
9611
Grade Unit
g/t
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“9,611.0”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · copperGrade: 9.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
9.7
Grade Unit
%
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“9.7”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-337Galena Mine · antimonyGrade: 7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-337
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
7
Grade Unit
%
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“7.0”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-339Galena Mine · silverGrade: 805.6Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
37-339
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
805.6
Grade Unit
g/t
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“805.6”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-339Galena Mine · copperGrade: 0.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-339
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.6
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.6”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

37-339Galena Mine · antimonyGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
37-339
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.5”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-357Galena Mine · silverGrade: 1391.6Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-357
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1391.6
Grade Unit
g/t
True Width
1.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,391.6”

Context: 1.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-357Galena Mine · copperGrade: 1.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-357
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.5
Grade Unit
%
True Width
1.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.5”

Context: 1.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-357Galena Mine · antimonyGrade: 1.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-357
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.5
Grade Unit
%
True Width
1.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.5”

Context: 1.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-357Galena Mine · leadGrade: 1.9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-357
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.9
Grade Unit
%
True Width
1.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.9”

Context: 1.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-358Galena Mine · silverGrade: 832Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-358
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
832
Grade Unit
g/t
True Width
1.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“832.0”

Context: 1.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-358Galena Mine · copperGrade: 1.4Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-358
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.4
Grade Unit
%
True Width
1.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.4”

Context: 1.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-358Galena Mine · antimonyGrade: 1.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-358
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.6
Grade Unit
%
True Width
1.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.6”

Context: 1.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-358Galena Mine · leadGrade: 3.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-358
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3.7
Grade Unit
%
True Width
1.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“3.7”

Context: 1.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · silverGrade: 935.9Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
935.9
Grade Unit
g/t
True Width
2.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“935.9”

Context: 2.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · copperGrade: 0.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
True Width
2.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.7”

Context: 2.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · antimonyGrade: 0.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.6
Grade Unit
%
True Width
2.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.6”

Context: 2.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · leadGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
2.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 2.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · silverGrade: 2390.9Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2390.9
Grade Unit
g/t
True Width
1.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“2,390.9”

Context: 1.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · copperGrade: 1.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.6
Grade Unit
%
True Width
1.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1.6”

Context: 1.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · antimonyGrade: 1.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.2
Grade Unit
%
True Width
1.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1.2”

Context: 1.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · leadGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
1.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.1”

Context: 1.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · silverGrade: 825.5Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
825.5
Grade Unit
g/t
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“825.5”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · copperGrade: 0.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.6
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.6”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · antimonyGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.5”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-365Galena Mine · leadGrade: 0.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-365
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.7”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · silverGrade: 1312.6Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1312.6
Grade Unit
g/t
True Width
1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,312.6”

Context: 1.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · copperGrade: 1.4Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.4
Grade Unit
%
True Width
1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.4”

Context: 1.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · antimonyGrade: 1.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.1
Grade Unit
%
True Width
1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.1”

Context: 1.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · leadGrade: 2.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.6
Grade Unit
%
True Width
1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.6”

Context: 1.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · silverGrade: 1365.1Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1365.1
Grade Unit
g/t
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1,365.1”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · copperGrade: 1.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.1
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1.1”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · antimonyGrade: 0.9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.9
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.9”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-366Galena Mine · leadGrade: 8.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-366
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
8.3
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“8.3”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-369Galena Mine · silverGrade: 20124Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
43-369
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
20124
Grade Unit
g/t
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“20,124.0”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-369Galena Mine · copperGrade: 8.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-369
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
8.3
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“8.3”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-369Galena Mine · antimonyGrade: 7.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-369
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
7.1
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“7.1”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

43-369Galena Mine · leadGrade: 3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
43-369
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“3.0”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-811Galena Mine · silverGrade: 2783.8Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
49-811
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2783.8
Grade Unit
g/t
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“2,783.8”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-811Galena Mine · copperGrade: 2.9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-811
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.9
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.9”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-811Galena Mine · antimonyGrade: 2.6Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-811
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.6
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“2.6”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-811Galena Mine · leadGrade: 8.8Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-811
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
8.8
Grade Unit
%
True Width
0.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“8.8”

Context: 0.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-812Galena Mine · silverGrade: 1031.7Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
49-812
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1031.7
Grade Unit
g/t
True Width
1.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,031.7”

Context: 1.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-812Galena Mine · copperGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-812
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
1.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 1.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-812Galena Mine · antimonyGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-812
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
1.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 1.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

49-812Galena Mine · leadGrade: 18Grade Unit: %View all details
Link to this fact

Identity

Hole ID
49-812
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
18
Grade Unit
%
True Width
1.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“18.0”

Context: 1.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · silverGrade: 619Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
619
Grade Unit
g/t
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“619.0”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · copperGrade: 1.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.1
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.1”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · antimonyGrade: 0.7Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.7
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.7”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · silverGrade: 432.3Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
432.3
Grade Unit
g/t
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Strong silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“432.3”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · copperGrade: 1.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.5
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1.5”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-166Galena Mine · antimonyGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-166
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.

Positive factors

  • True Width Disclosed

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.5”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-183Galena Mine · silverGrade: 4323Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
CO34-183
Project
Galena Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
4323
Grade Unit
g/t
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“4,323.0”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-183Galena Mine · copperGrade: 9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-183
Project
Galena Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
9
Grade Unit
%
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“9.0”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-183Galena Mine · antimonyGrade: 4.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-183
Project
Galena Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
4.5
Grade Unit
%
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“4.5”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

CO34-183Galena Mine · leadGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
CO34-183
Project
Galena Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.2”

Context: 0.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · silverGrade: 1109.5Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1109.5
Grade Unit
g/t
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“1,109.5”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · copperGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.3”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · antimonyGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.2”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · leadGrade: 2.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2.3
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“2.3”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · silverGrade: 379.5Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
379.5
Grade Unit
g/t
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Strong silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“379.5”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · copperGrade: 0.4Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.4
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“0.4”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-002Crescent Mine · antimonyGrade: 1.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-002
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.5
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Negative factors

  • Hole ID inferred from table structure

Evidence · table

“1.5”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-003Crescent Mine · silverGrade: 939.3Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
SF-003
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
939.3
Grade Unit
g/t
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“939.3”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-003Crescent Mine · copperGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-003
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.1”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-003Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-003
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
0.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.5”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-006Crescent Mine · silverGrade: 740.3Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-006
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
740.3
Grade Unit
g/t
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“740.3”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-006Crescent Mine · copperGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-006
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.2”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-006Crescent Mine · antimonyGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-006
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.1”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-006Crescent Mine · leadGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-006
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.2”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-010Crescent Mine · silverGrade: 1066.8Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-010
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1066.8
Grade Unit
g/t
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,066.8”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-010Crescent Mine · copperGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-010
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.2”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-010Crescent Mine · antimonyGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-010
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-010Crescent Mine · leadGrade: 1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-010
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1
Grade Unit
%
True Width
0.4 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.0”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-012Crescent Mine · silverGrade: 516.3Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-012
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
516.3
Grade Unit
g/t
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“516.3”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-012Crescent Mine · copperGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-012
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-012Crescent Mine · antimonyGrade: 1.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-012
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1.1
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“1.1”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-012Crescent Mine · leadGrade: 3.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-012
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3.5
Grade Unit
%
True Width
0.9 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“3.5”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · silverGrade: 1559.5Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1559.5
Grade Unit
g/t
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,559.5”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · copperGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.1”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · antimonyGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.8
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.8”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · leadGrade: 0.4Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.4
Grade Unit
%
True Width
1.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.4”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · silverGrade: 1891.1Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1891.1
Grade Unit
g/t
True Width
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“1,891.1”

Context: 1.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · copperGrade: 0.3Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.3
Grade Unit
%
True Width
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.3”

Context: 1.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-013Crescent Mine · leadGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-013
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
1.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.5”

Context: 1.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-014Crescent Mine · silverGrade: 1533.4Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-014
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
1533.4
Grade Unit
g/t
True Width
0.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“1,533.4”

Context: 0.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-014Crescent Mine · copperGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-014
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.2”

Context: 0.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-014Crescent Mine · antimonyGrade: 0.4Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-014
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.4
Grade Unit
%
True Width
0.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.4”

Context: 0.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-014Crescent Mine · leadGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-014
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
0.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.1”

Context: 0.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-017Crescent Mine · silverGrade: 3514.7Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SF-017
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
3514.7
Grade Unit
g/t
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“3,514.7”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-017Crescent Mine · copperGrade: 4.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-017
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
4.1
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“4.1”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-017Crescent Mine · antimonyGrade: 2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-017
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
2
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“2.0”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SF-017Crescent Mine · leadGrade: 0.2Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SF-017
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.2
Grade Unit
%
True Width
0.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.

Positive factors

  • True Width Disclosed
  • New Vein Discovery

Evidence · table

“0.2”

Context: 0.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SV-041Crescent Mine · silverGrade: 762Grade Unit: g/tView all details
Link to this fact

Identity

Hole ID
SV-041
Project
Crescent Mine
Commodity
silver
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
762
Grade Unit
g/t
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed

Evidence · table

“762.0”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SV-041Crescent Mine · copperGrade: 0.9Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SV-041
Project
Crescent Mine
Commodity
copper
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.9
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.9”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SV-041Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SV-041
Project
Crescent Mine
Commodity
antimony
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.5
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.5”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

SV-041Crescent Mine · leadGrade: 0.1Grade Unit: %View all details
Link to this fact

Identity

Hole ID
SV-041
Project
Crescent Mine
Commodity
lead
Region
usa_id
Reported Region
usa_id
Ticker
USAS

Geometry

Grade
0.1
Grade Unit
%
True Width
0.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

QA/QC

QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
antimony, lead

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-18T00:00:00.000Z

Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.

Positive factors

  • True Width Disclosed

Evidence · table

“0.1”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.