Americas Gold & Silver Corp - EX-99.1 (2026-09-18)
Original announcement by sec_edgar on
- Company
- Americas Gold and Silver Corporation
- Ticker
- USAS
- Exchange
- NYSE
- Region
- Idaho
- Primary commodity
- Silver
- Secondary commodities
- Copper, Lead, Antimony
- Document categories
- Drill results
- Extracted
- 2026-10-01 07:30:30 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Americas Gold and Silver Corporation announced high-grade drill results from its Galena Complex, including new vein discoveries at the Galena and Crescent Mines. The drilling, part of the company's largest-ever exploration and resource conversion program, returned exceptional silver, copper, lead, and antimony intercepts, with some exceeding currently modeled grades. These results are expected to significantly enhance future mine plans and are supported by comprehensive QA/QC procedures.
Reasoning: Americas Gold and Silver reported exceptional high-grade silver, copper, lead, and antimony drill results from its Galena Complex, including new vein discoveries and significant extensions of known mineralization, which are expected to positively impact future mine plans. The results are supported by comprehensive QA/QC.
Positive factors
- High-grade intercepts across multiple commodities (Ag, Cu, Pb, Sb)
- Discovery of new high-grade veins at both Galena and Crescent Mines
- Significant extension of existing veins, expanding mineralized footprint
- Infill drilling regularly intersecting higher silver grades than currently modeled
- Robust QA/QC procedures including ISO-17025 accredited labs and QP sign-off
- True width disclosed for all tabular intercepts
Negative factors
- Some intercepts have very narrow true widths, which may impact mineability
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 125
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Multiple silver intercepts exceed the 500 g/t exceptional threshold, including 20,124 g/t Ag, 9,611 g/t Ag, and 7,123 g/t Ag.
Evidence · text
“1,062 G/T AG, 0.7% CU OVER 1.3 METERS”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: Both tables explicitly state 'True Width (m)' for all reported intercepts.
Evidence · table
“True Width (m)”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drilling program is described as 'exploration drilling' and mentions 'significantly extending existing major veins' and 'expanding the 2025 discovery to 200m along strike and 200m in vertical extent'.
Evidence · text
“significantly extending existing major veins on multiple levels of the mine. I'd like to congratulate the entire Galena team for their hard work and exceptional safety record as we continue to identify new targets to feed the mine's significant future. Our recent drilling across the Galena Complex has continued to deliver exceptional results. The new vein discovery on the operating 49 level (49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb) is not only high grade, but also very close to our minimum mining width for our ongoing transition to long hole stoping. The high-grade discovery of the 9 Vein (24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb) in an area without any vein projections is a typical example of the numerous opportunities for new discoveries at Galena, even in higher levels with significant historical mining. Moving over to Coeur, the 520 Vein system continues to grow, with recent drilling expanding the 2025 discovery to 200m along strike and 200m in vertical extent while all directions remain open for further expansion.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC practices, including the use of certified reference materials, field duplicates, blanks, and independent ISO-17025 accredited laboratories (AAS, SVL, ALS Global), with sign-off by a Qualified Person.
Evidence · text
“The Company's standard QA/QC practices were utilized to ensure the integrity of the core and sample preparation at the Galena Complex through delivery of the samples to the assay lab. The drill core was stored in a secure facility, photographed, logged and sampled based on lithologic and mineralogical interpretations. Standards of certified reference materials, field duplicates and blanks were inserted as samples shipped with the core samples to the lab. Analytical work was carried out by American Analytical Services Inc. ("AAS") located in Osburn, Idaho, or SVL Analytical located in Kellogg Idaho. AAS and SVL are independent, ISO-17025 accredited laboratories. Sample preparation includes a 30-gram pulp sample analyzed by atomic absorption spectrometry ("AA") techniques to determine silver, copper, and lead, using aqua regia for pulp digestion. Samples returning values over 514 g/t Ag are re-assayed using fire-assay techniques for silver. Additionally, samples returning values over 23% Pb are re-assayed using titration techniques. Duplicate pulp samples are sent out quarterly to ALS Global, an independent, ISO-17025 accredited laboratory based in Reno, Nevada to perform an independent check analysis. A conventional AA technique was used for the analysis of silver, copper and lead at ALS Global with the same industry standard procedures as those used by AAS. The assay results listed in this report did not show any significant contamination during sample preparation or sample bias of analysis.”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The program is explicitly described as 'substantial infill and step-out exploration drilling' and aims to 'infill drill the existing Mineral Resource at Alhambra and South Veins'.
Evidence · text
“The assays reported today are a result of substantial infill and step-out exploration drilling conducted across multiple target areas at the Galena, Coeur (see Figure 1), and Crescent (see Figure 2) mines.”
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: Antimony (Sb) and Lead (Pb) are reported in significant percentages in many intercepts, which can be penalty elements.
Evidence · text
“high-grade Ag-Cu-Pb-Sb drill results”
New Vein Discoverypositive · Story-specific tag
No canonical definition is currently available.
Why it applies: The release highlights 'new vein discoveries at Galena and Crescent' and 'discovery of two new veins in the vicinity of Alhambra'.
Evidence · text
“Drilling has delivered new vein discoveries at Galena and Crescent as well returned infill drill intercepts that are regularly intersecting higher silver grades than the currently modeled Mineral Resource.”
Extracted facts
Stored fact records: 125. Some facts used in scoring do not have a stored record.
Drill Results (125)
Fact 1Galena Mine · silverGrade: 1062Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1062
- Grade Unit
- g/t
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept from a new vein discovery at the Galena Mine.
Positive factors
- Bonanza Intercept
- New Vein Discovery
Evidence · text
“new Galena Mine vein discovery grading 1,062 g/t Ag, 0.7% Cu over 1.3 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 2Galena Mine · copperGrade: 0.7Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper grade from a new vein discovery at the Galena Mine.
Positive factors
- New Vein Discovery
Evidence · text
“new Galena Mine vein discovery grading 1,062 g/t Ag, 0.7% Cu over 1.3 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 3Crescent Mine · silverGrade: 1891Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1891
- Grade Unit
- g/t
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept from Crescent drilling.
Positive factors
- Bonanza Intercept
Evidence · text
“Crescent drilling returns 1,891 g/t Ag, 0.3% Cu over 1.3 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 4Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept from Crescent drilling.
Evidence · text
“Crescent drilling returns 1,891 g/t Ag, 0.3% Cu over 1.3 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 5Crescent Mine · silverGrade: 1560Grade Unit: g/tIntercept: 1.1 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1560
- Grade Unit
- g/t
- Intercept
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept from Crescent drilling.
Positive factors
- Bonanza Intercept
Evidence · text
“1,560 g/t Ag, 0.3% Cu over 1.1 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 6Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.1 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept from Crescent drilling.
Evidence · text
“1,560 g/t Ag, 0.3% Cu over 1.1 meters”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Mine · silverGrade: 1061Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1061
- Grade Unit
- g/t
- Intercept
- 1.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept from a new vein discovery on the 49 level of the Galena Mine.
Positive factors
- Bonanza Intercept
- New Vein Discovery
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Mine · copperGrade: 0.7Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 1.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper grade from a new vein discovery on the 49 level of the Galena Mine.
Positive factors
- New Vein Discovery
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Mine · antimonyGrade: 0.6Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 1.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony grade from a new vein discovery on the 49 level of the Galena Mine.
Positive factors
- New Vein Discovery
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Mine · silverGrade: 7123Grade Unit: g/tIntercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 7123
- Grade Unit
- g/t
- Intercept
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept from the new 9 Vein discovery at the Galena Mine.
Positive factors
- Bonanza Intercept
- New Vein Discovery
Evidence · text
“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Mine · copperGrade: 3.24Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3.24
- Grade Unit
- %
- Intercept
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade copper intercept from the new 9 Vein discovery at the Galena Mine.
Positive factors
- New Vein Discovery
Evidence · text
“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Mine · antimonyGrade: 1.81Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.81
- Grade Unit
- %
- Intercept
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade antimony intercept from the new 9 Vein discovery at the Galena Mine.
Positive factors
- New Vein Discovery
Evidence · text
“24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · silverGrade: 1284.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1284.6
- Grade Unit
- g/t
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,284.6”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · copperGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.9”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · leadGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · silverGrade: 3608Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3608
- Grade Unit
- g/t
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“3,608.0”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · copperGrade: 3.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3.1
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“3.1”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · leadGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · silverGrade: 3054.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3054.4
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“3,054.4”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · copperGrade: 2.8Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.8
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.8”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Mine · leadGrade: 2.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.1
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.1”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · silverGrade: 1573.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1573.8
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,573.8”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · copperGrade: 1.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.3”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · antimonyGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · leadGrade: 1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · silverGrade: 806Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 806
- Grade Unit
- g/t
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“806.0”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · copperGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.8
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.8”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · antimonyGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.6”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · silverGrade: 9611Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 9611
- Grade Unit
- g/t
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“9,611.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · copperGrade: 9.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 9.7
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“9.7”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Mine · antimonyGrade: 7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 7
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“7.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Mine · silverGrade: 805.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 805.6
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“805.6”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Mine · copperGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Mine · silverGrade: 1391.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1391.6
- Grade Unit
- g/t
- True Width
- 1.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,391.6”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Mine · copperGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.5”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Mine · antimonyGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.5”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Mine · leadGrade: 1.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.9
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.9”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Mine · silverGrade: 832Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 832
- Grade Unit
- g/t
- True Width
- 1.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“832.0”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Mine · copperGrade: 1.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.4
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.4”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Mine · antimonyGrade: 1.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.6
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.6”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Mine · leadGrade: 3.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3.7
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“3.7”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · silverGrade: 935.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 935.9
- Grade Unit
- g/t
- True Width
- 2.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“935.9”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · copperGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · antimonyGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · leadGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · silverGrade: 2390.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2390.9
- Grade Unit
- g/t
- True Width
- 1.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“2,390.9”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · copperGrade: 1.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.6
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1.6”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · antimonyGrade: 1.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.2
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1.2”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.1”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · silverGrade: 825.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 825.5
- Grade Unit
- g/t
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“825.5”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · copperGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.6”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.5”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Mine · leadGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.7”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · silverGrade: 1312.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1312.6
- Grade Unit
- g/t
- True Width
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,312.6”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · copperGrade: 1.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.4
- Grade Unit
- %
- True Width
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.4”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · antimonyGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · leadGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · silverGrade: 1365.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1365.1
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1,365.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · copperGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · antimonyGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.9”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Mine · leadGrade: 8.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 8.3
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“8.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Mine · silverGrade: 20124Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 20124
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“20,124.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Mine · copperGrade: 8.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 8.3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“8.3”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Mine · antimonyGrade: 7.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 7.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“7.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Mine · leadGrade: 3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“3.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Mine · silverGrade: 2783.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2783.8
- Grade Unit
- g/t
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“2,783.8”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Mine · copperGrade: 2.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.9
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.9”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Mine · antimonyGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Mine · leadGrade: 8.8Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 8.8
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“8.8”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Mine · silverGrade: 1031.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1031.7
- Grade Unit
- g/t
- True Width
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,031.7”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Mine · antimonyGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Mine · leadGrade: 18Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 18
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“18.0”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · silverGrade: 619Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 619
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“619.0”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · copperGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · antimonyGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · silverGrade: 432.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 432.3
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Strong silver intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“432.3”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · copperGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine, hole ID inferred.
Positive factors
- True Width Disclosed
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Mine · silverGrade: 4323Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 4323
- Grade Unit
- g/t
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade silver intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“4,323.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Mine · copperGrade: 9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 9
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade copper intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“9.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Mine · antimonyGrade: 4.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 4.5
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Extremely high-grade antimony intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“4.5”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Mine · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Galena Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · silverGrade: 1109.5Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1109.5
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- New Vein Discovery
Evidence · table
“1,109.5”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.3”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · antimonyGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.2”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · leadGrade: 2.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2.3
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“2.3”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · silverGrade: 379.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 379.5
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Strong silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Negative factors
- Hole ID inferred from table structure
Evidence · table
“379.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · copperGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Negative factors
- Hole ID inferred from table structure
Evidence · table
“0.4”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · antimonyGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, hole ID inferred, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Negative factors
- Hole ID inferred from table structure
Evidence · table
“1.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · silverGrade: 939.3Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 939.3
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- New Vein Discovery
Evidence · table
“939.3”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · copperGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.1”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · silverGrade: 740.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 740.3
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“740.3”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · antimonyGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · silverGrade: 1066.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1066.8
- Grade Unit
- g/t
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,066.8”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · antimonyGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · leadGrade: 1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.0”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · silverGrade: 516.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 516.3
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“516.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · antimonyGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · leadGrade: 3.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3.5
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“3.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · silverGrade: 1559.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1559.5
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,559.5”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · copperGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · antimonyGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.8
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.8”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · leadGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.4”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · silverGrade: 1891.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1891.1
- Grade Unit
- g/t
- True Width
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,891.1”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · leadGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · silverGrade: 1533.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 1533.4
- Grade Unit
- g/t
- True Width
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- New Vein Discovery
Evidence · table
“1,533.4”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.2”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · antimonyGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.4”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.1”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · silverGrade: 3514.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 3514.7
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- New Vein Discovery
Evidence · table
“3,514.7”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · copperGrade: 4.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 4.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“4.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · antimonyGrade: 2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 2
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“2.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine, contributing to new vein discovery.
Positive factors
- True Width Disclosed
- New Vein Discovery
Evidence · table
“0.2”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · silverGrade: 762Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 762
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: High-grade silver intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“762.0”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · copperGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant copper intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.9”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Significant antimony intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony, lead
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Lead intercept with disclosed true width from infill/exploration drilling at Crescent Mine.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.