Americas Gold and Silver Continues Track Record of Significant Discoveries at the Galena Complex with a New Galena Mine Vein Discovery Grading 1,062 g/t Ag, 0.7% Cu over 1.3 Meters While Crescent Drilling Returns 1,891 g/t Ag, 0.3% Cu over 1.3 Meters and 1,560 g/t Ag, 0.3% Cu over 1.1 Meters
Original announcement by orestocks on
- Company
- Americas Gold and Silver Corporation
- Ticker
- USA.TO
- Exchange
- Unavailable
- Region
- Idaho
- Primary commodity
- Silver
- Secondary commodities
- Copper, Lead, Antimony
- Document categories
- Drill results
- Extracted
- 2026-09-18 11:07:22 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Americas Gold and Silver announced exceptional high-grade silver and copper drill results from its Galena Complex in Idaho, including new vein discoveries at the Galena and Crescent mines. Intercepts include 1,062 g/t Ag and 0.7% Cu over 1.3 meters at Galena, and 1,891 g/t Ag and 0.3% Cu over 1.3 meters at Crescent. The drilling program, which combines infill and step-out exploration, has identified new high-grade shoots and is aimed at converting Mineral Resources for future mine planning.
Reasoning: The announcement reports multiple bonanza-grade silver intercepts, including new vein discoveries at both the Galena and Crescent mines, with true widths disclosed. The high grades and new discoveries significantly extend known mineralization and indicate strong upside potential for future mine plans. The drilling also aims for Mineral Resource conversion, suggesting de-risking.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
- QA/QC Disclosed
- Category Upgrade
Facts used in scoring: 133
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Multiple silver intercepts exceed the 500 g/t exceptional threshold for silver, including 1,062 g/t Ag, 1,891 g/t Ag, 1,560 g/t Ag, 1,061 g/t Ag, 7,123 g/t Ag, 1,109.5 g/t Ag, 939.3 g/t Ag, 1,284.6 g/t Ag, 3,608.0 g/t Ag, 3,054.4 g/t Ag, 1,573.8 g/t Ag, 806.0 g/t Ag, 9,611.0 g/t Ag, 805.6 g/t Ag, 1,391.6 g/t Ag, 832.0 g/t Ag, 935.9 g/t Ag, 2,390.9 g/t Ag, 825.5 g/t Ag, 1,312.6 g/t Ag, 1,365.1 g/t Ag, 20,124.0 g/t Ag, 2,783.8 g/t Ag, 1,031.7 g/t Ag, 619.0 g/t Ag, 432.3 g/t Ag, 4,323.0 g/t Ag, 379.5 g/t Ag, 740.3 g/t Ag, 1,066.8 g/t Ag, 516.3 g/t Ag, 1,559.5 g/t Ag, 1,891.1 g/t Ag, 1,533.4 g/t Ag, 3,514.7 g/t Ag, and 762.0 g/t Ag.
Evidence · text
“1,062 g/t Ag”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document explicitly states 'Reported intercepts are estimated true widths' for both tables and provides true width values for all intercepts.
Evidence · text
“Reported intercepts are estimated true widths”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drilling program includes 'step-out exploration drilling' and has delivered 'new vein discoveries at Galena and Crescent' and 'significantly extending existing major veins'.
Evidence · text
“new vein discoveries at Galena and Crescent as well returned infill drill intercepts that are regularly intersecting higher silver grades than the currently modeled Mineral Resource.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC practices, including the use of certified reference materials, field duplicates, and blanks, and names ISO-17025 accredited laboratories (AAS, SVL, ALS Global).
Evidence · text
“The Company's standard QA/QC practices were utilized to ensure the integrity of the core and sample preparation at the Galena Complex through delivery of the samples to the assay lab. The drill core was stored in a secure facility, photographed, logged and sampled based on lithologic and mineralogical interpretations. Standards of certified reference materials, field duplicates and blanks were inserted as samples shipped with the core samples to the lab.”
Category Upgradepositive · Story-specific tag
Resource confidence improved — Inferred upgraded to Indicated, or Indicated to Measured. De-risking signal.
Why it applies: The drilling program is described as a 'Mineral Resource conversion drilling program' and aims to support 'an updated Mineral Resource Estimate in 2027', indicating an intent to upgrade resource categories.
Evidence · text
“Mineral Resource conversion drilling program”
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: Antimony (Sb) is consistently reported in the assay results, which is a known penalty element.
Evidence · text
“0.6% Sb”
Extracted facts
Stored fact records: 133. Some facts used in scoring do not have a stored record.
Drill Results (133)
Fact 1Galena Complex · silverGrade: 1062Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1062
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Galena Mine Vein Discovery:1.3m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept from a new vein discovery at the Galena Mine, with a good true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · text
“new Galena Mine Vein Discovery Grading 1,062 g/t Ag, 0.7% Cu over 1.3 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 2Galena Complex · copperGrade: 0.7Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 1.3 m
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Galena Mine Vein Discovery:1.3m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a strong copper intercept associated with a new bonanza-grade silver vein discovery at the Galena Mine, adding to the overall value.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“new Galena Mine Vein Discovery Grading 1,062 g/t Ag, 0.7% Cu over 1.3 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 3Crescent Mine · silverGrade: 1891Grade Unit: g/tIntercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1891
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Crescent Drilling:1.3m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptionally high-grade silver intercept from Crescent drilling, with a good true width, contributing significantly to the project's potential.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · text
“Crescent Drilling Returns 1,891 g/t Ag, 0.3% Cu over 1.3 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 4Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.3 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.3 m
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Crescent Drilling:1.3m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept accompanying a bonanza-grade silver intercept at Crescent, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
Evidence · text
“Crescent Drilling Returns 1,891 g/t Ag, 0.3% Cu over 1.3 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 5Crescent Mine · silverGrade: 1560Grade Unit: g/tIntercept: 1.1 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1560
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Crescent Drilling:1.1m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: Another bonanza-grade silver intercept from Crescent drilling, with a good true width, further highlighting the high-grade potential.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · text
“1,560 g/t Ag, 0.3% Cu over 1.1 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 6Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.1 mNeeds review: drill_no_hole_idView all detailsHide details
Identity
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- Crescent Drilling:1.1m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- drill_no_hole_id
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept accompanying a bonanza-grade silver intercept at Crescent, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
Evidence · text
“1,560 g/t Ag, 0.3% Cu over 1.1 Meters”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Complex · silverGrade: 1061Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1061
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 1.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-817:1.2m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole 49-817 represents a new vein discovery on the 49 level, with a good true width, indicating significant new mineralization close to minimum mining width.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Complex · copperGrade: 0.7Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 1.2 m
- True Width
- 1.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-817:1.2m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept from hole 49-817, part of a new vein discovery, adding to the polymetallic nature and value of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-817Galena Complex · antimonyGrade: 0.6Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- 49-817
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 1.2 m
- True Width
- 1.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-817:1.2m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept from hole 49-817, part of a new vein discovery, contributing to the critical minerals profile of the project, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“49-817 intersecting 1.2m of 1,061 g/t Ag, 0.7% Cu and 0.6% Sb”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Complex · silverGrade: 7123Grade Unit: g/tIntercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 7123
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 24-407:0.4m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade silver intercept from hole 24-407 (9 Vein), representing a new discovery in an area with no prior vein projections, indicating significant exploration upside.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · text
“9 Vein (24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb)”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Complex · copperGrade: 3.24Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3.24
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 24-407:0.4m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong copper intercept from hole 24-407, part of a new vein discovery, significantly enhancing the polymetallic value of the new zone.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“9 Vein (24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb)”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
24-407Galena Complex · antimonyGrade: 1.81Grade Unit: %Intercept: 0.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 24-407
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.81
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 24-407:0.4m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong antimony intercept from hole 24-407, part of a new vein discovery, adding significant critical mineral value, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“9 Vein (24-407 intersecting 0.4m of 7,123 g/t Ag, 3.24 %Cu and 1.81% Sb)”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · silverGrade: 1109.5Grade Unit: g/tIntercept: 1.1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1109.5
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole SF-002 represents a new vein discovery at the Crescent Mine, with a good true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · text
“SF-002 and SF-003 intersected 1.1m of 1,109.5 g/t Ag, 0.3% Cu”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · copperGrade: 0.3Grade Unit: %Intercept: 1.1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept from hole SF-002, part of a new vein discovery, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“SF-002 and SF-003 intersected 1.1m of 1,109.5 g/t Ag, 0.3% Cu”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · silverGrade: 939.3Grade Unit: g/tIntercept: 0.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 939.3
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-003:0.8m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole SF-003 represents a new vein discovery at the Crescent Mine, with a good true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · text
“0.8m of 939.3 g/t Ag, 0.1% Cu”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · copperGrade: 0.1Grade Unit: %Intercept: 0.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.8 m
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-003:0.8m
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A weak copper intercept from hole SF-003, part of a new vein discovery, contributing to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · text
“0.8m of 939.3 g/t Ag, 0.1% Cu”
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · silverGrade: 1284.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1284.6
- Grade Unit
- g/t
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,284.6”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · copperGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.9”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · antimonyGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace antimony intercept with a good true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.0”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · leadGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · silverGrade: 3608Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3608
- Grade Unit
- g/t
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“3,608.0”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · copperGrade: 3.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3.1
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong copper intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“3.1”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · leadGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · silverGrade: 3054.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3054.4
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“3,054.4”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · copperGrade: 2.8Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.8
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong copper intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“2.8”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-336Galena Complex · leadGrade: 2.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-336
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.1
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-336:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“2.1”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · silverGrade: 1573.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1573.8
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a narrow true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,573.8”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · copperGrade: 1.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a narrow true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.3”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · antimonyGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace antimony intercept with a narrow true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · leadGrade: 1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a narrow true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · silverGrade: 806Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 806
- Grade Unit
- g/t
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“806.0”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · copperGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.8
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.8”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · antimonyGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · leadGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0
- Grade Unit
- %
- True Width
- 0.5 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.5
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.0”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · silverGrade: 9611Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 9611
- Grade Unit
- g/t
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a very narrow true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“9,611.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · copperGrade: 9.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 9.7
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade copper intercept with a very narrow true width from infill drilling at Galena, confirming very high-grade polymetallic mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“9.7”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-337Galena Complex · antimonyGrade: 7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-337
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 7
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-337:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade antimony intercept with a very narrow true width from infill drilling at Galena, adding significant critical mineral value, though antimony can be a deleterious element.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“7.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Complex · silverGrade: 805.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 805.6
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-339:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“805.6”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Complex · copperGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-339:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Complex · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-339:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
37-339Galena Complex · leadGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 37-339
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 37-339:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.0”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Complex · silverGrade: 1391.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1391.6
- Grade Unit
- g/t
- True Width
- 1.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-357:1.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,391.6”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Complex · copperGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-357:1.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.5”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Complex · antimonyGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-357:1.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“1.5”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-357Galena Complex · leadGrade: 1.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-357
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.9
- Grade Unit
- %
- True Width
- 1.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-357:1.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.9”
Context: 1.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Complex · silverGrade: 832Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 832
- Grade Unit
- g/t
- True Width
- 1.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-358:1.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“832.0”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Complex · copperGrade: 1.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.4
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-358:1.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.4”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Complex · antimonyGrade: 1.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.6
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-358:1.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“1.6”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-358Galena Complex · leadGrade: 3.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-358
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3.7
- Grade Unit
- %
- True Width
- 1.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-358:1.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“3.7”
Context: 1.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · silverGrade: 935.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 935.9
- Grade Unit
- g/t
- True Width
- 2.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:2.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“935.9”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · copperGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:2.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · antimonyGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:2.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · leadGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 2.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:2.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · silverGrade: 2390.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2390.9
- Grade Unit
- g/t
- True Width
- 1.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:1.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“2,390.9”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · copperGrade: 1.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.6
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:1.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.6”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · antimonyGrade: 1.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.2
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:1.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“1.2”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 1.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:1.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 1.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · silverGrade: 825.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 825.5
- Grade Unit
- g/t
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“825.5”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · copperGrade: 0.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.6”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-365Galena Complex · leadGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-365
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-365:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · silverGrade: 1312.6Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1312.6
- Grade Unit
- g/t
- True Width
- 1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:1.0
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,312.6”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · copperGrade: 1.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.4
- Grade Unit
- %
- True Width
- 1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:1.0
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.4”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · antimonyGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:1.0
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · leadGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:1.0
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · silverGrade: 1365.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1365.1
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,365.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · copperGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · antimonyGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.9”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-366Galena Complex · leadGrade: 8.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-366
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 8.3
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-366:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“8.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Complex · silverGrade: 20124Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 20124
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-369:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a very narrow true width from infill drilling at Galena, confirming extremely high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“20,124.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Complex · copperGrade: 8.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 8.3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-369:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade copper intercept with a very narrow true width from infill drilling at Galena, confirming extremely high-grade polymetallic mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“8.3”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Complex · antimonyGrade: 7.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 7.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-369:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade antimony intercept with a very narrow true width from infill drilling at Galena, adding significant critical mineral value, though antimony can be a deleterious element.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“7.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
43-369Galena Complex · leadGrade: 3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 43-369
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 43-369:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a very narrow true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“3.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Complex · silverGrade: 2783.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2783.8
- Grade Unit
- g/t
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-811:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“2,783.8”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Complex · copperGrade: 2.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.9
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-811:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong copper intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“2.9”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Complex · antimonyGrade: 2.6Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.6
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-811:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“2.6”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-811Galena Complex · leadGrade: 8.8Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-811
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 8.8
- Grade Unit
- %
- True Width
- 0.7 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-811:0.7
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong lead intercept with a good true width from infill drilling at Galena, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“8.8”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Complex · silverGrade: 1031.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1031.7
- Grade Unit
- g/t
- True Width
- 1.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-812:1.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,031.7”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Complex · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-812:1.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Complex · antimonyGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-812:1.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
49-812Galena Complex · leadGrade: 18Grade Unit: %View all detailsHide details
Identity
- Hole ID
- 49-812
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 18
- Grade Unit
- %
- True Width
- 1.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- 49-812:1.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade lead intercept with a good true width from infill drilling at Galena, confirming very high-grade polymetallic mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“18.0”
Context: 1.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · silverGrade: 619Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 619
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“619.0”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · copperGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · antimonyGrade: 0.7Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.7
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.7”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · leadGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.0”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · silverGrade: 432.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 432.3
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a strong silver intercept with a good true width from infill drilling at Galena, confirming high-grade mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“432.3”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · copperGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Galena, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-166Galena Complex · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-166
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-166:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Galena, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Complex · silverGrade: 4323Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Complex
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 4323
- Grade Unit
- g/t
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-183:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a very narrow true width from infill drilling at Galena, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“4,323.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Complex · copperGrade: 9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Complex
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 9
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-183:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade copper intercept with a very narrow true width from infill drilling at Galena, confirming extremely high-grade polymetallic mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“9.0”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Complex · antimonyGrade: 4.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Complex
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 4.5
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-183:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: An exceptional bonanza-grade antimony intercept with a very narrow true width from infill drilling at Galena, adding significant critical mineral value, though antimony can be a deleterious element.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“4.5”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
CO34-183Galena Complex · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- CO34-183
- Project
- Galena Complex
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- CO34-183:0.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a very narrow true width from infill drilling at Galena.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · silverGrade: 1109.5Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1109.5
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole SF-002 represents a new vein discovery at the Crescent Mine, with a good true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · table
“1,109.5”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept from hole SF-002, part of a new vein discovery, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.3”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · antimonyGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace antimony intercept from hole SF-002, part of a new vein discovery, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.2”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · leadGrade: 2.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2.3
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept from hole SF-002, part of a new vein discovery, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“2.3”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · silverGrade: 379.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 379.5
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a strong silver intercept with a good true width from hole SF-002, part of a new vein discovery at the Crescent Mine, indicating new mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“379.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · copperGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from hole SF-002, part of a new vein discovery, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.4”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-002Crescent Mine · antimonyGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-002
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.5
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-002:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from hole SF-002, part of a new vein discovery, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“1.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · silverGrade: 939.3Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 939.3
- Grade Unit
- g/t
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-003:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole SF-003 represents a new vein discovery at the Crescent Mine, with a good true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · table
“939.3”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · copperGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-003:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A weak copper intercept with a good true width from hole SF-003, part of a new vein discovery, adding to the polymetallic nature of the mineralization.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.1”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-003Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-003
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.8 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-003:0.8
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from hole SF-003, part of a new vein discovery, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.5”
Context: 0.8
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · silverGrade: 740.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 740.3
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-006:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Crescent, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“740.3”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-006:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace copper intercept with a good true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · antimonyGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-006:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace antimony intercept with a good true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-006Crescent Mine · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-006
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-006:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · silverGrade: 1066.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1066.8
- Grade Unit
- g/t
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-010:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a narrow true width from infill drilling at Crescent, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,066.8”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-010:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace copper intercept with a narrow true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.2”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · antimonyGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-010:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a narrow true width from infill drilling at Crescent, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-010Crescent Mine · leadGrade: 1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-010
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1
- Grade Unit
- %
- True Width
- 0.4 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-010:0.4
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a narrow true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“1.0”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · silverGrade: 516.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 516.3
- Grade Unit
- g/t
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-012:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Crescent, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“516.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-012:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · antimonyGrade: 1.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1.1
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-012:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a good true width from infill drilling at Crescent, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“1.1”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-012Crescent Mine · leadGrade: 3.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-012
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3.5
- Grade Unit
- %
- True Width
- 0.9 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-012:0.9
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong lead intercept with a good true width from infill drilling at Crescent, confirming high-grade polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“3.5”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · silverGrade: 1559.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1559.5
- Grade Unit
- g/t
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Crescent, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,559.5”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · copperGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace copper intercept with a good true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · antimonyGrade: 0.8Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.8
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Crescent, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.8”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · leadGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 1.1 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.1
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a good true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.4”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · silverGrade: 1891.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1891.1
- Grade Unit
- g/t
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is an exceptional bonanza-grade silver intercept with a good true width from infill drilling at Crescent, confirming very high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“1,891.1”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · copperGrade: 0.3Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.3
- Grade Unit
- %
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate copper intercept with a good true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.3”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-013Crescent Mine · leadGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-013
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 1.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-013:1.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A moderate lead intercept with a good true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · silverGrade: 1533.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 1533.4
- Grade Unit
- g/t
- True Width
- 0.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-014:0.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This bonanza-grade silver intercept from hole SF-014 represents a new vein discovery at the Crescent Mine, with a narrow true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · table
“1,533.4”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · copperGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-014:0.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace copper intercept with a narrow true width from hole SF-014, part of a new vein discovery at Crescent.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.2”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · antimonyGrade: 0.4Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.4
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-014:0.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a narrow true width from hole SF-014, part of a new vein discovery, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.4”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-014Crescent Mine · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-014
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.3 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-014:0.3
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a narrow true width from hole SF-014, part of a new vein discovery at Crescent.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.1”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · silverGrade: 3514.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 3514.7
- Grade Unit
- g/t
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-017:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This exceptional bonanza-grade silver intercept from hole SF-017 represents a new vein discovery at the Crescent Mine, with a very narrow true width, indicating significant new mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · table
“3,514.7”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · copperGrade: 4.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 4.1
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-017:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A very strong copper intercept with a very narrow true width from hole SF-017, part of a new vein discovery, significantly enhancing the polymetallic value of the new zone.
Positive factors
- Bonanza Intercept
- True Width Disclosed
- Step-Out Extension
Evidence · table
“4.1”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · antimonyGrade: 2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 2
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-017:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong antimony intercept with a very narrow true width from hole SF-017, part of a new vein discovery, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“2.0”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SF-017Crescent Mine · leadGrade: 0.2Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SF-017
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.2
- Grade Unit
- %
- True Width
- 0.2 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SF-017:0.2
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a very narrow true width from hole SF-017, part of a new vein discovery at Crescent.
Positive factors
- True Width Disclosed
- Step-Out Extension
Evidence · table
“0.2”
Context: 0.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · silverGrade: 762Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- silver
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 762
- Grade Unit
- g/t
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SV-041:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept with a good true width from infill drilling at Crescent, confirming high-grade mineralization.
Positive factors
- Bonanza Intercept
- True Width Disclosed
Evidence · table
“762.0”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · copperGrade: 0.9Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- copper
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.9
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SV-041:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A strong copper intercept with a good true width from infill drilling at Crescent, confirming polymetallic mineralization.
Positive factors
- True Width Disclosed
Evidence · table
“0.9”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · antimonyGrade: 0.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- antimony
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.5
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SV-041:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A notable antimony intercept with a good true width from infill drilling at Crescent, contributing to the critical minerals profile, though antimony can be a deleterious element.
Positive factors
- True Width Disclosed
Evidence · table
“0.5”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
SV-041Crescent Mine · leadGrade: 0.1Grade Unit: %View all detailsHide details
Identity
- Hole ID
- SV-041
- Project
- Crescent Mine
- Commodity
- lead
- Region
- usa_id
- Reported Region
- usa_id
- Ticker
- USA.TO
Geometry
- Grade
- 0.1
- Grade Unit
- %
- True Width
- 0.6 m
Classification
- Program
- mixed
- Sample Type
- drill
- Group ID
- SV-041:0.6
- Mining Method
- underground
QA/QC
- Laboratory
- American Analytical Services Inc. and SVL Analytical and ALS Global
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- antimony
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-18T00:00:00.000Z
Reasoning: A trace lead intercept with a good true width from infill drilling at Crescent.
Positive factors
- True Width Disclosed
Evidence · table
“0.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.
Why it applies: deleterious_flag is true
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.