Alkane Drilling Confirms and Extends Gold-Antimony Mineral System at Nagambie, Victoria

Original announcement by globenewswire on

Company
Alkane Resources Limited
Ticker
ALK
Exchange
Unavailable
Region
Victoria
Primary commodity
Gold
Secondary commodities
Antimony, Arsenic
Document categories
Drill results, Agreement transaction
Extracted
2026-10-20 00:38:38 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Alkane Resources announced positive drill results from its Nagambie project in Victoria, confirming and extending the gold-antimony mineral system. Highlights include high-grade intercepts such as 17.0 g/t gold and 5.9% antimony over 1.3m, and wide zones up to 42.01m at 1.8 g/t gold and 0.2% antimony. The drilling successfully extended the C2 zone 115m below its previously known extent and identified new mineralized domains, demonstrating significant exploration potential.

Reasoning: Alkane's drilling at Nagambie has confirmed and extended the gold-antimony mineral system with high-grade and wide intercepts, including a significant 115m step-out extension of the C2 zone and discovery of new mineralized domains. The results are supported by comprehensive JORC-compliant QA/QC procedures and QP sign-off, indicating strong geological confidence and significant exploration potential. However, the metal equivalent assumptions are based on a different project (Costerfield), and arsenic is noted as a deleterious element.

Positive factors

  • High grades
  • Wide intercepts
  • True width disclosed
  • Step-Out Extension
  • New zones discovered
  • QA/QC Disclosed
  • JORC Compliant
  • QP Signed

Negative factors

  • Deleterious Elements Present
  • Metal Equivalent Opaque

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 58

Classification and evidence

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: Estimated True Width (ETW) is provided for all reported intercepts, indicating the actual thickness perpendicular to the structure.

Evidence · text

“Estimated True Width (m)”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The C2 zone has been intercepted a further 115m below the previously known extent, highlighting the open nature of the resource and extending mineralization.

Evidence · text

“Additionally, the C2 zone has been intercepted a further 115m below the previously known extent, highlighting the open nature of the resource.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed JORC Table 1 outlining sampling techniques, quality of assay data, and laboratory tests, including the use of CRMs, blanks, and duplicates, and an ISO/IEC 17025 accredited lab.

Evidence · text

“Appendix 2 - JORC Code, 2012 Edition – Table 1 Section 1 Sampling Techniques and Data”

JORC Compliantpositive · Story-specific tag

Resource estimate prepared in compliance with JORC Code (Australia) — high reporting standard.

Why it applies: The Competent Person's Statement explicitly states that the information is reported in accordance with the JORC Code (2012 Edition).

Evidence · text

“qualify as a Competent Person as defined in the 2012 Edition of the “Australian Code for Reporting of Exploration Results, Mineral Resources, and Ore Reserves” (JORC Code).”

QP/CP Signedpositive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: Mr Chris Davis, a Chartered Professional (Geology) of the AusIMM and MAIG, is named as the Competent Person and Qualified Person who approved the scientific and technical information.

Evidence · text

“The information in this report fairly represents, information compiled and verified by Mr Chris Davis. Mr Davis is a Chartered Professional (Geology) of the Australasian Institute of Mining and Metallurgy (MAusIMM CP(Geo)), and a Member of the Australian Institute of Geoscientists (MAIG).”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals, including higher cut-offs for sub-intervals.

Evidence · text

“Results were composited at a 1g/t AuEq compositing cutoff with maximum 5m of internal dilution. A 5g/t AuEq compositing cutoff with a maximum of 2m of internal dilution was applied to define “including” intervals.”

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: Arsenic is noted as being present in the Nagambie Project in the form of arsenopyrite and arsenian pyrite, and is likely to have a close relationship to a portion of the gold mineralisation.

Evidence · text

“Arsenic is present in the Nagambie Project in form of arsenopyrite and arsenian pyrite and is likely to have a close relationship to a portion of the gold mineralisation.”

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used.

Why it applies: While metal equivalent assumptions are disclosed, they are based on established processing and sales in respect of Costerfield, not Nagambie-specific metallurgical test work.

Evidence · text

“The Au recovery assumption and Sb recovery assumption is based on established processing and sales in respect of Costerfield. It is the Company’s opinion that all elements included in the metal equivalent calculation have a reasonable potential to be recovered and sold.”

Extracted facts

Stored fact records: 58. Some facts used in scoring do not have a stored record.

Drill Results (58)

ADD001Nagambie West · goldGrade: 3.3Grade Unit: g/tIntercept: 10.55 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
3.3
Grade Unit
g/t
Intercept
10.55 m
True Width
10.39 m
From
156.3 m
To
166.85 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:156.3-166.85
Mining Method
underground

Location

Location
C3
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This intercept shows good gold grade over a significant true width, contributing positively to the project's potential.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“3.3”

Context: 10.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.39

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0.7Grade Unit: %Intercept: 10.55 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.7
Grade Unit
%
Intercept
10.55 m
True Width
10.39 m
From
156.3 m
To
166.85 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:156.3-166.85
Mining Method
underground

Location

Location
C3
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This intercept shows good antimony grade over a significant true width, contributing positively to the project's potential.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“0.7”

Context: 10.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.39

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 17Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
17
Grade Unit
g/t
Intercept
1.25 m
True Width
1.23 m
From
156.53 m
To
157.78 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:156.53-157.78
Mining Method
underground

Location

Location
C3
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept over a narrow true width is exceptional for an epithermal deposit, indicating bonanza-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“17.0”

Context: 1.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.23

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 5.9Grade Unit: %Intercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
5.9
Grade Unit
%
Intercept
1.25 m
True Width
1.23 m
From
156.53 m
To
157.78 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:156.53-157.78
Mining Method
underground

Location

Location
C3
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony intercept over a narrow true width is exceptional for an epithermal deposit, indicating bonanza-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“5.9”

Context: 1.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.23

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 1.1Grade Unit: g/tIntercept: 30.75 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
30.75 m
True Width
17.64 m
From
180.4 m
To
211.15 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:180.4-211.15
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide gold intercept in a new domain is a significant discovery, indicating potential for broader mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“1.1”

Context: 30.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0.1Grade Unit: %Intercept: 30.75 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.1
Grade Unit
%
Intercept
30.75 m
True Width
17.64 m
From
180.4 m
To
211.15 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:180.4-211.15
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide antimony intercept in a new domain is a significant discovery, indicating potential for broader mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“0.1”

Context: 30.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 1.8Grade Unit: g/tIntercept: 42.01 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.8
Grade Unit
g/t
Intercept
42.01 m
True Width
32.18 m
From
214.88 m
To
256.89 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:214.88-256.89
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This very wide gold intercept in a new domain is highly material, indicating significant potential for bulk mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“1.8”

Context: 42.01

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 32.18

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0.2Grade Unit: %Intercept: 42.01 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.2
Grade Unit
%
Intercept
42.01 m
True Width
32.18 m
From
214.88 m
To
256.89 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:214.88-256.89
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This very wide antimony intercept in a new domain is highly material, indicating significant potential for bulk mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“0.2”

Context: 42.01

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 32.18

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 6.3Grade Unit: g/tIntercept: 3.38 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
6.3
Grade Unit
g/t
Intercept
3.38 m
True Width
2.59 m
From
240.12 m
To
243.5 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:240.12-243.5
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within a new domain adds to the overall positive results.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“6.3”

Context: 3.38

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.59

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 3.38 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
3.38 m
True Width
2.59 m
From
240.12 m
To
243.5 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:240.12-243.5
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This sub-interval shows no antimony, but the gold grade is high.

Positive factors

  • True width disclosed

Evidence · table

“0.0”

Context: 3.38

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.59

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 0.5Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
0.45 m
True Width
0.34 m
From
253.65 m
To
254.1 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:253.65-254.1
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This narrow gold intercept, while low grade, is part of a new domain and contributes to the overall understanding.

Positive factors

  • True width disclosed

Evidence · table

“0.5”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 18.7Grade Unit: %Intercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
18.7
Grade Unit
%
Intercept
0.45 m
True Width
0.34 m
From
253.65 m
To
254.1 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:253.65-254.1
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade antimony intercept over a narrow true width is highly significant, indicating very high-grade mineralization in a new domain.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“18.7”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 1.6Grade Unit: g/tIntercept: 4.25 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.6
Grade Unit
g/t
Intercept
4.25 m
True Width
2.44 m
From
273.15 m
To
277.4 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:273.15-277.4
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold intercept in a new domain, while moderate grade, contributes to the overall understanding of the new mineralization.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“1.6”

Context: 4.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 4.25 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
4.25 m
True Width
2.44 m
From
273.15 m
To
277.4 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:273.15-277.4
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain shows no grade, but the gold grade is moderate.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.0”

Context: 4.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 1.2Grade Unit: g/tIntercept: 9.71 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
9.71 m
True Width
4.85 m
From
306.3 m
To
316.01 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:306.3-316.01
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold intercept in the C2W zone shows moderate grade over a good true width, confirming mineralization.

Positive factors

  • True width disclosed

Evidence · table

“1.2”

Context: 9.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 2.5Grade Unit: %Intercept: 9.71 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.5
Grade Unit
%
Intercept
9.71 m
True Width
4.85 m
From
306.3 m
To
316.01 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:306.3-316.01
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony intercept over a good true width in the C2W zone is positive, confirming significant mineralization.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.5”

Context: 9.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.85

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 4.6Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
4.6
Grade Unit
g/t
Intercept
0.4 m
True Width
0.2 m
From
306.7 m
To
307.1 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:306.7-307.1
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“4.6”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 20.6Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
20.6
Grade Unit
%
Intercept
0.4 m
True Width
0.2 m
From
306.7 m
To
307.1 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:306.7-307.1
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade antimony sub-interval within the C2W zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“20.6”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 3.6Grade Unit: g/tIntercept: 1.69 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
3.6
Grade Unit
g/t
Intercept
1.69 m
True Width
0.84 m
From
314.16 m
To
315.85 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:314.16-315.85
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“3.6”

Context: 1.69

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 9Grade Unit: %Intercept: 1.69 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
9
Grade Unit
%
Intercept
1.69 m
True Width
0.84 m
From
314.16 m
To
315.85 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:314.16-315.85
Mining Method
underground

Location

Location
C2W
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade antimony sub-interval within the C2W zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“9.0”

Context: 1.69

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 1.1Grade Unit: g/tIntercept: 13.7 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
13.7 m
True Width
9.52 m
From
335.7 m
To
349.4 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:335.7-349.4
Mining Method
underground

Location

Location
C2E
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold intercept in the C2E zone shows moderate grade over a good true width, confirming mineralization.

Positive factors

  • True width disclosed

Evidence · table

“1.1”

Context: 13.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 13.7 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
13.7 m
True Width
9.52 m
From
335.7 m
To
349.4 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:335.7-349.4
Mining Method
underground

Location

Location
C2E
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in the C2E zone shows no grade, but the gold grade is moderate.

Positive factors

  • True width disclosed

Evidence · table

“0.0”

Context: 13.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 2.9Grade Unit: g/tIntercept: 7.24 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
7.24 m
True Width
4.15 m
From
391.88 m
To
399.12 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:391.88-399.12
Mining Method
underground

Location

Location
N1
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept in the N1 zone is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.9”

Context: 7.24

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.15

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 7.24 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
7.24 m
True Width
4.15 m
From
391.88 m
To
399.12 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:391.88-399.12
Mining Method
underground

Location

Location
N1
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in the N1 zone shows no grade, but the gold grade is high.

Positive factors

  • True width disclosed

Evidence · table

“0.0”

Context: 7.24

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.15

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 11.4Grade Unit: g/tIntercept: 1.38 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
11.4
Grade Unit
g/t
Intercept
1.38 m
True Width
0.79 m
From
393.25 m
To
394.63 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:393.25-394.63
Mining Method
underground

Location

Location
N1
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade gold sub-interval within the N1 zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“11.4”

Context: 1.38

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.79

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 1.38 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
1.38 m
True Width
0.79 m
From
393.25 m
To
394.63 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:393.25-394.63
Mining Method
underground

Location

Location
N1
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony sub-interval in the N1 zone shows no grade, but the gold grade is bonanza.

Positive factors

  • True width disclosed

Evidence · table

“0.0”

Context: 1.38

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.79

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · goldGrade: 3.1Grade Unit: g/tIntercept: 1.42 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
3.1
Grade Unit
g/t
Intercept
1.42 m
True Width
1.32 m
From
478.64 m
To
480.06 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:478.64-480.06
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept in a new domain is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed
  • New zones discovered

Evidence · table

“3.1”

Context: 1.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD001Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 1.42 mView all details
Link to this fact

Identity

Hole ID
ADD001
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
1.42 m
True Width
1.32 m
From
478.64 m
To
480.06 m
Hole Depth
526.8 m
Intercept Depth
156.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD001:478.64-480.06
Mining Method
underground

Location

Location
New
Easting
340925
Northing
5925962
CRS
GDA94 Z55
Elevation
129.3 m
Azimuth
53.2 °
Dip
-39.2 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain shows no grade, but the gold grade is high.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.0”

Context: 1.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 3.2Grade Unit: g/tIntercept: 1.46 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
3.2
Grade Unit
g/t
Intercept
1.46 m
True Width
1.15 m
From
97.89 m
To
99.35 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:97.89-99.35
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept in a new domain is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed
  • New zones discovered

Evidence · table

“3.2”

Context: 1.46

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.15

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 1.46 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
1.46 m
True Width
1.15 m
From
97.89 m
To
99.35 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:97.89-99.35
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain shows no grade, but the gold grade is high.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.0”

Context: 1.46

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.15

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 2Grade Unit: g/tIntercept: 5.12 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2
Grade Unit
g/t
Intercept
5.12 m
True Width
4.43 m
From
137.1 m
To
142.22 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:137.1-142.22
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept in a new domain is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed
  • New zones discovered

Evidence · table

“2.0”

Context: 5.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.1Grade Unit: %Intercept: 5.12 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.1
Grade Unit
%
Intercept
5.12 m
True Width
4.43 m
From
137.1 m
To
142.22 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:137.1-142.22
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain shows low grade, but the gold grade is high.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.1”

Context: 5.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.43

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 1.2Grade Unit: g/tIntercept: 3.63 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
3.63 m
True Width
2.38 m
From
155.98 m
To
159.61 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:155.98-159.61
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold intercept in a new domain, while moderate grade, contributes to the overall understanding of the new mineralization.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“1.2”

Context: 3.63

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.38

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.3Grade Unit: %Intercept: 3.63 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.3
Grade Unit
%
Intercept
3.63 m
True Width
2.38 m
From
155.98 m
To
159.61 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:155.98-159.61
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain, while moderate grade, contributes to the overall understanding of the new mineralization.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.3”

Context: 3.63

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.38

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 1.3Grade Unit: g/tIntercept: 6.32 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.3
Grade Unit
g/t
Intercept
6.32 m
True Width
4.47 m
From
180.96 m
To
187.28 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:180.96-187.28
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold intercept in a new domain, while moderate grade, contributes to the overall understanding of the new mineralization.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“1.3”

Context: 6.32

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.47

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 6.32 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
6.32 m
True Width
4.47 m
From
180.96 m
To
187.28 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:180.96-187.28
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony intercept in a new domain shows no grade, but the gold grade is moderate.

Positive factors

  • True width disclosed
  • New zones discovered

Evidence · table

“0.0”

Context: 6.32

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.47

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 1.2Grade Unit: g/tIntercept: 22.49 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
22.49 m
True Width
16.18 m
From
196.33 m
To
218.82 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:196.33-218.82
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide gold intercept in a new domain is a significant discovery, indicating potential for broader mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“1.2”

Context: 22.49

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.18

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.1Grade Unit: %Intercept: 22.49 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.1
Grade Unit
%
Intercept
22.49 m
True Width
16.18 m
From
196.33 m
To
218.82 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:196.33-218.82
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide antimony intercept in a new domain is a significant discovery, indicating potential for broader mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed
  • New zones discovered

Evidence · table

“0.1”

Context: 22.49

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.18

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 7.3Grade Unit: g/tIntercept: 0.67 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
7.3
Grade Unit
g/t
Intercept
0.67 m
True Width
0.48 m
From
208.02 m
To
208.69 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:208.02-208.69
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within a new domain is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“7.3”

Context: 0.67

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 0.67 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
0.67 m
True Width
0.48 m
From
208.02 m
To
208.69 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:208.02-208.69
Mining Method
underground

Location

Location
New
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony sub-interval in a new domain shows no grade, but the gold grade is high.

Positive factors

  • True width disclosed

Evidence · table

“0.0”

Context: 0.67

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 2.1Grade Unit: g/tIntercept: 10.02 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.1
Grade Unit
g/t
Intercept
10.02 m
True Width
6.44 m
From
221.7 m
To
231.72 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:221.7-231.72
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold intercept in the C2W zone is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.1”

Context: 10.02

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.5Grade Unit: %Intercept: 10.02 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.5
Grade Unit
%
Intercept
10.02 m
True Width
6.44 m
From
221.7 m
To
231.72 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:221.7-231.72
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony intercept in the C2W zone is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“0.5”

Context: 10.02

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 3.7Grade Unit: g/tIntercept: 0.97 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
0.97 m
True Width
0.62 m
From
222.61 m
To
223.58 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:222.61-223.58
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“3.7”

Context: 0.97

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.8Grade Unit: %Intercept: 0.97 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.8
Grade Unit
%
Intercept
0.97 m
True Width
0.62 m
From
222.61 m
To
223.58 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:222.61-223.58
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“0.8”

Context: 0.97

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 12.6Grade Unit: g/tIntercept: 0.36 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
12.6
Grade Unit
g/t
Intercept
0.36 m
True Width
0.23 m
From
224.54 m
To
224.9 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:224.54-224.9
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade gold sub-interval within the C2W zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“12.6”

Context: 0.36

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.23

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.1Grade Unit: %Intercept: 0.36 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.36 m
True Width
0.23 m
From
224.54 m
To
224.9 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:224.54-224.9
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony sub-interval in the C2W zone shows low grade, but the gold grade is bonanza.

Positive factors

  • True width disclosed

Evidence · table

“0.1”

Context: 0.36

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.23

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 2.8Grade Unit: g/tIntercept: 2.32 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.8
Grade Unit
g/t
Intercept
2.32 m
True Width
1.49 m
From
229.4 m
To
231.72 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:229.4-231.72
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.8”

Context: 2.32

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.49

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 2Grade Unit: %Intercept: 2.32 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2
Grade Unit
%
Intercept
2.32 m
True Width
1.49 m
From
229.4 m
To
231.72 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:229.4-231.72
Mining Method
underground

Location

Location
C2W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.0”

Context: 2.32

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.49

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 2.2Grade Unit: g/tIntercept: 24.1 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.2
Grade Unit
g/t
Intercept
24.1 m
True Width
15.49 m
From
400.52 m
To
424.62 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:400.52-424.62
Mining Method
underground

Location

Location
C1W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide gold intercept in the C1W zone is positive, confirming mineralization.

Positive factors

  • Wide intercepts
  • True width disclosed

Evidence · table

“2.2”

Context: 24.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 15.49

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0Grade Unit: %Intercept: 24.1 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0
Grade Unit
%
Intercept
24.1 m
True Width
15.49 m
From
400.52 m
To
424.62 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:400.52-424.62
Mining Method
underground

Location

Location
C1W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide antimony intercept in the C1W zone shows no grade, but the gold grade is high.

Positive factors

  • Wide intercepts
  • True width disclosed

Evidence · table

“0.0”

Context: 24.10

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 15.49

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · goldGrade: 5.5Grade Unit: g/tIntercept: 4.99 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
4.99 m
True Width
3.21 m
From
408.77 m
To
413.76 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:408.77-413.76
Mining Method
underground

Location

Location
C1W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade gold sub-interval within the C1W zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“5.5”

Context: 4.99

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.21

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD006Nagambie West · antimonyGrade: 0.1Grade Unit: %Intercept: 4.99 mView all details
Link to this fact

Identity

Hole ID
ADD006
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.1
Grade Unit
%
Intercept
4.99 m
True Width
3.21 m
From
408.77 m
To
413.76 m
Hole Depth
554.3 m
Intercept Depth
97.89 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD006:408.77-413.76
Mining Method
underground

Location

Location
C1W
Easting
341010
Northing
5926012
CRS
GDA94 Z55
Elevation
129.8 m
Azimuth
49.2 °
Dip
-45.6 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This antimony sub-interval in the C1W zone shows low grade, but the gold grade is bonanza.

Positive factors

  • True width disclosed

Evidence · table

“0.1”

Context: 4.99

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.21

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · goldGrade: 0.6Grade Unit: g/tIntercept: 22.64 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
22.64 m
True Width
20.68 m
From
592.59 m
To
615.23 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:592.59-615.23
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide gold intercept in the C2W zone, representing a significant step-out extension, is highly positive for resource growth.

Positive factors

  • Wide intercepts
  • True width disclosed
  • Step-Out Extension

Evidence · table

“0.6”

Context: 22.64

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 20.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · antimonyGrade: 0.8Grade Unit: %Intercept: 22.64 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
0.8
Grade Unit
%
Intercept
22.64 m
True Width
20.68 m
From
592.59 m
To
615.23 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:592.59-615.23
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This wide antimony intercept in the C2W zone, representing a significant step-out extension, is highly positive for resource growth.

Positive factors

  • Wide intercepts
  • True width disclosed
  • Step-Out Extension

Evidence · table

“0.8”

Context: 22.64

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 20.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · goldGrade: 2.1Grade Unit: g/tIntercept: 0.39 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
2.1
Grade Unit
g/t
Intercept
0.39 m
True Width
0.31 m
From
592.94 m
To
593.33 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:592.94-593.33
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade gold sub-interval within the C2W zone is positive, despite its narrow width.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“2.1”

Context: 0.39

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · antimonyGrade: 17.3Grade Unit: %Intercept: 0.39 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
17.3
Grade Unit
%
Intercept
0.39 m
True Width
0.31 m
From
592.94 m
To
593.33 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:592.94-593.33
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This bonanza-grade antimony sub-interval within the C2W zone is highly significant, indicating very high-grade mineralization.

Positive factors

  • Bonanza Intercept
  • True width disclosed

Evidence · table

“17.3”

Context: 0.39

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · goldGrade: 1.4Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
gold
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
0.75 m
True Width
0.69 m
From
604.79 m
To
605.54 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:604.79-605.54
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This gold sub-interval within the C2W zone shows moderate grade, contributing to the overall understanding.

Positive factors

  • True width disclosed

Evidence · table

“1.4”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.69

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

ADD013Nagambie West · antimonyGrade: 7.3Grade Unit: %Intercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
ADD013
Project
Nagambie West
Commodity
antimony
Region
australia_vic
Reported Region
australia_vic
Ticker
ALK

Geometry

Grade
7.3
Grade Unit
%
Intercept
0.75 m
True Width
0.69 m
From
604.79 m
To
605.54 m
Hole Depth
787.6 m
Intercept Depth
592.59 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
ADD013:604.79-605.54
Mining Method
underground

Location

Location
C2W
Easting
341482
Northing
5926098
CRS
GDA94 Z55
Elevation
129.2 m
Azimuth
278.4 °
Dip
-43.5 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
On Site Laboratory Services in Bendigo
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
5 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-10-19T00:00:00.000Z

Reasoning: This high-grade antimony sub-interval within the C2W zone is positive, confirming mineralization.

Positive factors

  • High grades
  • True width disclosed

Evidence · table

“7.3”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.69

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Deleterious Elements Presentnegative

Penalty elements (arsenic, antimony, etc.) or refractory concerns noted in the release.

Why it applies: deleterious_flag is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.