Alaska Silver expands Illinois Creek program
Original announcement by miningnewsnorth on
- Company
- Alaska Silver Corp.
- Ticker
- Unavailable
- Exchange
- Unavailable
- Region
- western Alaska
- Primary commodity
- Silver
- Secondary commodities
- Zinc, Lead, Copper, Gold
- Document categories
- Drill results, Capital raise
- Extracted
- 2026-09-18 21:25:24 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
Alaska Silver Corp. is expanding its 2026 drill program at the Illinois Creek project in western Alaska from 6,000 to 9,000 meters. The expansion is funded by a C$7.6 million private investment in public equity, with significant participation from Crescat Capital.
Reasoning: The company is expanding its exploration program by 50% following a successful C$7.6 million capital raise, targeting high-priority silver-zinc-lead deposits.
Positive factors
- expansion of drill program
- successful capital raise
- strong support from existing shareholder
- high-grade surface samples
Facts used in scoring: 16
Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The document mentions surface exploration and trenching including rock samples, but does not explicitly detail assay protocols or lab certification in this snippet.
Evidence · text
“After completing surface exploration and trenching, which included the collection of rock samples”
Extracted facts
Stored fact records: 15. Some facts used in scoring do not have a stored record.
Drill Results (15)
SS25-0001silverGrade: 61.86Grade Unit: g/tIntercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0001
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 61.86
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 27 m
- To
- 30 m
- Intercept Depth
- 27 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0001:27-30
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Silver-rich intercept from 2025 drilling at Silver Sage.
Positive factors
- multi-commodity intercept
Evidence · text
“3 m averaging 61.86 g/t silver, 0.15% zinc, 0.51% lead, 0.15% copper, and 0.43 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0001zincGrade: 0.15Grade Unit: %Intercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0001
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 3 m
- From
- 27 m
- To
- 30 m
- Intercept Depth
- 27 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0001:27-30
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Zinc component of SS25-0001 intercept.
Evidence · text
“3 m averaging 61.86 g/t silver, 0.15% zinc, 0.51% lead, 0.15% copper, and 0.43 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0001leadGrade: 0.51Grade Unit: %Intercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0001
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.51
- Grade Unit
- %
- Intercept
- 3 m
- From
- 27 m
- To
- 30 m
- Intercept Depth
- 27 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0001:27-30
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Lead component of SS25-0001 intercept.
Evidence · text
“3 m averaging 61.86 g/t silver, 0.15% zinc, 0.51% lead, 0.15% copper, and 0.43 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0001copperGrade: 0.15Grade Unit: %Intercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0001
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 3 m
- From
- 27 m
- To
- 30 m
- Intercept Depth
- 27 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0001:27-30
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Copper component of SS25-0001 intercept.
Evidence · text
“3 m averaging 61.86 g/t silver, 0.15% zinc, 0.51% lead, 0.15% copper, and 0.43 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0001goldGrade: 0.43Grade Unit: g/tIntercept: 3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0001
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 27 m
- To
- 30 m
- Intercept Depth
- 27 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0001:27-30
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Gold component of SS25-0001 intercept.
Evidence · text
“3 m averaging 61.86 g/t silver, 0.15% zinc, 0.51% lead, 0.15% copper, and 0.43 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0003silverGrade: 55.74Grade Unit: g/tIntercept: 6.7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0003
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 55.74
- Grade Unit
- g/t
- Intercept
- 6.7 m
- From
- 25.2 m
- To
- 31.9 m
- Intercept Depth
- 25.2 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0003:25.2-31.9
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Silver component of SS25-0003 intercept.
Evidence · text
“6.7 m averaging 55.74 g/t silver, 1.18% zinc, 0.04% lead, 0.01% copper, and 0.15 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0003zincGrade: 1.18Grade Unit: %Intercept: 6.7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0003
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 1.18
- Grade Unit
- %
- Intercept
- 6.7 m
- From
- 25.2 m
- To
- 31.9 m
- Intercept Depth
- 25.2 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0003:25.2-31.9
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Zinc component of SS25-0003 intercept.
Evidence · text
“6.7 m averaging 55.74 g/t silver, 1.18% zinc, 0.04% lead, 0.01% copper, and 0.15 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0003leadGrade: 0.04Grade Unit: %Intercept: 6.7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0003
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 6.7 m
- From
- 25.2 m
- To
- 31.9 m
- Intercept Depth
- 25.2 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0003:25.2-31.9
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Lead component of SS25-0003 intercept.
Evidence · text
“6.7 m averaging 55.74 g/t silver, 1.18% zinc, 0.04% lead, 0.01% copper, and 0.15 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0003copperGrade: 0.01Grade Unit: %Intercept: 6.7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0003
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 6.7 m
- From
- 25.2 m
- To
- 31.9 m
- Intercept Depth
- 25.2 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0003:25.2-31.9
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Copper component of SS25-0003 intercept.
Evidence · text
“6.7 m averaging 55.74 g/t silver, 1.18% zinc, 0.04% lead, 0.01% copper, and 0.15 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0003goldGrade: 0.15Grade Unit: g/tIntercept: 6.7 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0003
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 6.7 m
- From
- 25.2 m
- To
- 31.9 m
- Intercept Depth
- 25.2 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0003:25.2-31.9
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Gold component of SS25-0003 intercept.
Evidence · text
“6.7 m averaging 55.74 g/t silver, 1.18% zinc, 0.04% lead, 0.01% copper, and 0.15 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0004silverGrade: 148Grade Unit: g/tIntercept: 4.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0004
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 148
- Grade Unit
- g/t
- Intercept
- 4.4 m
- From
- 14.8 m
- To
- 19.2 m
- Intercept Depth
- 14.8 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0004:14.8-19.2
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Silver component of SS25-0004 intercept.
Evidence · text
“4.4 m averaging 148 g/t silver, 0.24% zinc, 0.68% lead, 0.06% copper, and 0.17 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0004zincGrade: 0.24Grade Unit: %Intercept: 4.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0004
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 4.4 m
- From
- 14.8 m
- To
- 19.2 m
- Intercept Depth
- 14.8 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0004:14.8-19.2
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Zinc component of SS25-0004 intercept.
Evidence · text
“4.4 m averaging 148 g/t silver, 0.24% zinc, 0.68% lead, 0.06% copper, and 0.17 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0004leadGrade: 0.68Grade Unit: %Intercept: 4.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0004
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 4.4 m
- From
- 14.8 m
- To
- 19.2 m
- Intercept Depth
- 14.8 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0004:14.8-19.2
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Lead component of SS25-0004 intercept.
Evidence · text
“4.4 m averaging 148 g/t silver, 0.24% zinc, 0.68% lead, 0.06% copper, and 0.17 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0004copperGrade: 0.06Grade Unit: %Intercept: 4.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0004
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 4.4 m
- From
- 14.8 m
- To
- 19.2 m
- Intercept Depth
- 14.8 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0004:14.8-19.2
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Copper component of SS25-0004 intercept.
Evidence · text
“4.4 m averaging 148 g/t silver, 0.24% zinc, 0.68% lead, 0.06% copper, and 0.17 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
SS25-0004goldGrade: 0.17Grade Unit: g/tIntercept: 4.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- SS25-0004
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 4.4 m
- From
- 14.8 m
- To
- 19.2 m
- Intercept Depth
- 14.8 m
Classification
- Sample Type
- drill
- Group ID
- SS25-0004:14.8-19.2
QA/QC
- QA/QC Disclosed
- Yes
- QA/QC Methods
- blanks
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-14T00:00:00.000Z
Reasoning: Gold component of SS25-0004 intercept.
Evidence · text
“4.4 m averaging 148 g/t silver, 0.24% zinc, 0.68% lead, 0.06% copper, and 0.17 g/t gold”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.