Abitibi Metals Intersects 3.72% CuEq over 9.2 m Within a Broader 1.25% CuEq over 60.2 m at the B26 Deposit

Original announcement by prospectors_exchange on

Company
Abitibi Metals Corp
Ticker
AMQ
Exchange
Unavailable
Region
Québec
Primary commodity
Copper
Secondary commodities
Gold, Silver, Zinc
Document categories
Drill results
Extracted
2026-09-18 12:53:27 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Abitibi Metals reported new drill results from its B26 Polymetallic Deposit in Québec, highlighted by a wide intercept of 1.25% CuEq over 60.2 meters, including a high-grade zone of 3.72% CuEq over 9.2 meters. These results, part of an ongoing resource-development program, confirm strong grade continuity and expand the Western Down-Plunge Zone, supporting future resource growth.

Reasoning: The drilling delivered wide, high-grade copper-equivalent intercepts, significantly exceeding prior copper grades and GT product, confirming strong continuity and expanding the Western Down-Plunge Zone, which is highly material for resource growth. The results include one of the strongest intercepts to date for the B26 Deposit.

Positive factors

  • High-grade copper-equivalent intercepts, significantly exceeding prior copper grades and GT product
  • Significant intercept length of 60.2m at 1.25% CuEq, demonstrating strong continuity
  • True width estimated for all significant intercepts, enhancing geological confidence
  • Transparent metal equivalent assumptions with disclosed prices and recovery factors
  • Comprehensive QA/QC procedures disclosed, including certified lab and QP sign-off
  • Expansion of the Western Down-Plunge Zone, indicating resource growth potential

Negative factors

  • Gold, silver, and zinc grades in the headline intercept are lower than prior averages, though offset by high copper

Facts used in scoring: 100

Extracted facts

Stored fact records: 100. Some facts used in scoring do not have a stored record.

Drill Results (100)

1274-24-342-W1B26 Deposit · copperGrade: 2.5Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.5
Grade Unit
%
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper equivalent grade based on spot prices, confirming down-dip continuity at depth.

Positive factors

  • True width estimated
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept length

Evidence · table

“2.6”

Context: 1404.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low gold grade, contributing to overall polymetallic potential but not significant on its own.

Positive factors

  • True width estimated
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low gold grade
  • Narrow intercept length

Evidence · table

“0.1”

Context: 1404.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low silver grade, contributing to overall polymetallic potential but not significant on its own.

Positive factors

  • True width estimated
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low silver grade
  • Narrow intercept length

Evidence · table

“2.7”

Context: 1404.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with no reported zinc, indicating limited contribution from this metal in this interval.

Positive factors

  • True width estimated
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Narrow intercept length

Evidence · table

“0.0”

Context: 1404.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 1.1Grade Unit: %Intercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.1
Grade Unit
%
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A very wide and strong copper equivalent intercept based on spot prices, significantly exceeding prior average grades and GT product, indicating excellent continuity and high materiality for resource growth.

Positive factors

  • Exceptional intercept length (60.2m)
  • Strong copper equivalent grade (1.3% CuEq) based on spot prices
  • True width estimated (52.1m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed
  • Significantly exceeds prior average copper grades and GT product

Evidence · table

“1.3”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A very wide intercept with a moderate gold grade, contributing to the overall polymetallic nature of the deposit, but below prior average gold grades.

Positive factors

  • Exceptional intercept length (60.2m)
  • True width estimated (52.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.1”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 5Grade Unit: g/tIntercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5
Grade Unit
g/t
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A very wide intercept with a moderate silver grade, contributing to the overall polymetallic nature of the deposit, but significantly below prior average silver grades.

Positive factors

  • Exceptional intercept length (60.2m)
  • True width estimated (52.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“5.0”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A very wide intercept with no reported zinc, indicating limited contribution from this metal in this interval and significantly below prior average zinc grades.

Positive factors

  • Exceptional intercept length (60.2m)
  • True width estimated (52.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 0.7Grade Unit: %Intercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
%
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a good copper equivalent grade based on spot prices, contributing to the overall strong intercept and indicating good continuity.

Positive factors

  • Strong intercept length (25.2m)
  • Moderate copper equivalent grade (1.0% CuEq) based on spot prices
  • True width estimated (21.8m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.0”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • Strong intercept length (25.2m)
  • True width estimated (21.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.2”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 5.8Grade Unit: g/tIntercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • Strong intercept length (25.2m)
  • True width estimated (21.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“5.8”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a low zinc grade, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • Strong intercept length (25.2m)
  • True width estimated (21.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.1”

Context: 548.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 1.6Grade Unit: %Intercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.6
Grade Unit
%
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A high-grade copper equivalent sub-interval based on spot prices, contributing significantly to the overall strong intercept and indicating excellent localized mineralization.

Positive factors

  • High copper equivalent grade (2.0% CuEq) based on spot prices
  • True width estimated (3.8m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.0”

Context: 562.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (3.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.3”

Context: 562.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 9Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
9
Grade Unit
g/t
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (3.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“9.0”

Context: 562.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a low zinc grade, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (3.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.1”

Context: 562.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 2.2Grade Unit: %Intercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.2
Grade Unit
%
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A strong and wide copper equivalent sub-interval based on spot prices, significantly contributing to the overall high-grade intercept and indicating excellent continuity.

Positive factors

  • Strong intercept length (18.8m)
  • High copper equivalent grade (2.5% CuEq) based on spot prices
  • True width estimated (16.3m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.5”

Context: 580.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • Strong intercept length (18.8m)
  • True width estimated (16.3m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.2”

Context: 580.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 6.9Grade Unit: g/tIntercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
6.9
Grade Unit
g/t
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • Strong intercept length (18.8m)
  • True width estimated (16.3m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“6.9”

Context: 580.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • Strong intercept length (18.8m)
  • True width estimated (16.3m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 580.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 3.4Grade Unit: %Intercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.4
Grade Unit
%
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: An exceptional high-grade copper equivalent sub-interval based on spot prices, significantly contributing to the overall strong intercept and representing one of the best results to date.

Positive factors

  • Exceptional copper equivalent grade (3.9% CuEq) based on spot prices, above 75th percentile for VMS copper
  • True width estimated (8.0m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed
  • Contributes to one of the strongest intercepts drilled to date

Evidence · table

“3.9”

Context: 590.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (8.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.3”

Context: 590.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 9.9Grade Unit: g/tIntercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
9.9
Grade Unit
g/t
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (8.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“9.9”

Context: 590.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (8.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 590.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · copperGrade: 0.6Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
%
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper equivalent grade based on spot prices, extending the known system eastward but not highly material on its own.

Positive factors

  • True width estimated (2.7m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept length

Evidence · table

“1.2”

Context: 549.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (2.7m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Gold grade is lower than prior average

Evidence · table

“0.5”

Context: 549.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · silverGrade: 5.5Grade Unit: g/tIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (2.7m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Silver grade is significantly lower than prior average

Evidence · table

“5.5”

Context: 549.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (2.7m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Low zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.1”

Context: 549.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 0.5Grade Unit: %Intercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
%
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A wide intercept with a moderate copper equivalent grade based on spot prices, successfully extending the mineralized footprint of the WDP.

Positive factors

  • Strong intercept length (40.0m)
  • Moderate copper equivalent grade (0.7% CuEq) based on spot prices
  • True width estimated (30.6m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“0.7”

Context: 966.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A wide intercept with a low gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • Strong intercept length (40.0m)
  • True width estimated (30.6m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.1”

Context: 966.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 1.9Grade Unit: g/tIntercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A wide intercept with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • Strong intercept length (40.0m)
  • True width estimated (30.6m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“1.9”

Context: 966.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A wide intercept with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • Strong intercept length (40.0m)
  • True width estimated (30.6m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 966.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 1.3Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.3
Grade Unit
%
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant sub-interval with a good copper equivalent grade based on spot prices, contributing to the overall strong intercept and indicating good localized mineralization.

Positive factors

  • Moderate copper equivalent grade (1.7% CuEq) based on spot prices
  • True width estimated (5.8m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.7”

Context: 970.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (5.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Gold grade is lower than prior average

Evidence · table

“0.3”

Context: 970.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (5.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Silver grade is significantly lower than prior average

Evidence · table

“2.7”

Context: 970.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (5.8m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 970.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 1.2Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.2
Grade Unit
%
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a good copper equivalent grade based on spot prices, contributing to the overall strong intercept and indicating good localized mineralization.

Positive factors

  • Moderate copper equivalent grade (1.8% CuEq) based on spot prices
  • True width estimated (2.1m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept length

Evidence · table

“1.8”

Context: 975.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a moderate gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (2.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Gold grade is lower than prior average

Evidence · table

“0.5”

Context: 975.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 3Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
g/t
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (2.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Silver grade is significantly lower than prior average

Evidence · table

“3.0”

Context: 975.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (2.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 975.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 0.8Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.8
Grade Unit
%
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate copper equivalent grade based on spot prices, contributing to the overall polymetallic nature of the deposit.

Positive factors

  • True width estimated (5.4m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.0”

Context: 982.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (5.4m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low gold grade
  • Gold grade is lower than prior average

Evidence · table

“0.1”

Context: 982.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 2.5Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.5
Grade Unit
g/t
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (5.4m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low silver grade
  • Silver grade is significantly lower than prior average

Evidence · table

“2.5”

Context: 982.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0.2Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low zinc grade, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (5.4m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.2”

Context: 982.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · copperGrade: 1.4Grade Unit: %Intercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.4
Grade Unit
%
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A significant intercept with a good copper equivalent grade based on spot prices, adding continuity to the mineralized footprint in the Western Down-Plunge Zone.

Positive factors

  • Moderate copper equivalent grade (1.5% CuEq) based on spot prices
  • True width estimated (10.0m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.5”

Context: 985.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A moderate intercept with a low gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (10.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low gold grade
  • Gold grade is lower than prior average

Evidence · table

“0.1”

Context: 985.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · silverGrade: 2.6Grade Unit: g/tIntercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A moderate intercept with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (10.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low silver grade
  • Silver grade is significantly lower than prior average

Evidence · table

“2.6”

Context: 985.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A moderate intercept with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (10.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 985.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · copperGrade: 2.1Grade Unit: %Intercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.1
Grade Unit
%
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A high-grade copper equivalent sub-interval based on spot prices, contributing significantly to the overall strong intercept and indicating excellent localized mineralization.

Positive factors

  • High copper equivalent grade (2.3% CuEq) based on spot prices
  • True width estimated (4.2m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.3”

Context: 989.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a low gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (4.2m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low gold grade
  • Gold grade is lower than prior average

Evidence · table

“0.1”

Context: 989.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · silverGrade: 3.6Grade Unit: g/tIntercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.6
Grade Unit
g/t
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (4.2m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low silver grade
  • Silver grade is significantly lower than prior average

Evidence · table

“3.6”

Context: 989.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow sub-interval with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (4.2m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 989.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low copper equivalent grade based on spot prices, targeting a lower-grade expansional target and not highly material on its own.

Positive factors

  • True width estimated (3.0m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept length
  • Low copper equivalent grade

Evidence · table

“0.6”

Context: 641.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low gold grade, contributing to the overall polymetallic nature, but below prior average gold grades.

Positive factors

  • True width estimated (3.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Gold grade is lower than prior average

Evidence · table

“0.3”

Context: 641.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · silverGrade: 0.7Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (3.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Low silver grade
  • Silver grade is significantly lower than prior average

Evidence · table

“0.7”

Context: 641.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with no reported zinc, indicating limited contribution from this metal and significantly below prior average zinc grades.

Positive factors

  • True width estimated (3.0m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • No zinc grade
  • Zinc grade is significantly lower than prior average

Evidence · table

“0.0”

Context: 641.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low copper equivalent grade based on spot prices, targeting a lower-grade expansional target and not highly material on its own.

Positive factors

  • True width estimated (1.5m)
  • QA/QC disclosed
  • QP signed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept length
  • Low copper equivalent grade

Evidence · table

“0.9”

Context: 633.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with no reported gold, indicating limited contribution from this metal and below prior average gold grades.

Positive factors

  • True width estimated (1.5m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • No gold grade
  • Gold grade is lower than prior average

Evidence · table

“0.0”

Context: 633.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · silverGrade: 7.7Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
7.7
Grade Unit
g/t
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate silver grade, contributing to the overall polymetallic nature, but significantly below prior average silver grades.

Positive factors

  • True width estimated (1.5m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Silver grade is significantly lower than prior average

Evidence · table

“7.7”

Context: 633.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · zincGrade: 3Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
%
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a moderate zinc grade, contributing to the overall polymetallic nature, but below prior average zinc grades.

Positive factors

  • Moderate zinc grade (3.0%) for a VMS deposit
  • True width estimated (1.5m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept length
  • Zinc grade is lower than prior average

Evidence · table

“3.0”

Context: 633.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · copperGrade: 0.3Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
%
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with a low copper grade, confirming alteration but not robust mineralization in this area.

Positive factors

  • True width estimated (6.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • Low copper grade

Evidence · table

“0.3”

Context: 1234.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: A narrow intercept with no reported gold, indicating limited contribution from this metal and below prior average gold grades.

Positive factors

  • True width estimated (6.1m)
  • QA/QC disclosed
  • QP signed

Negative factors

  • No gold grade
  • Gold grade is lower than prior average

Evidence · table

“0.0”

Context: 1234.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Intercept Depth
1234 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 18.9 g/t·m is below.

Negative factors

  • 2.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.7”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Intercept Depth
1234 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.4 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · goldGrade: 0.7Grade Unit: g/tIntercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.0 g/t·m is below.

Negative factors

  • 0.7 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.7”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · silverGrade: 0.6Grade Unit: g/tIntercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.3 g/t·m is below.

Negative factors

  • 0.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.9Grade Unit: %Intercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.9
Grade Unit
%
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.3 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.9”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 1.4Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.5 g/t·m is below.

Negative factors

  • 1.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 41.1Grade Unit: g/tIntercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
41.1
Grade Unit
g/t
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 41.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 846.7 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“41.1”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 1Grade Unit: %Intercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1
Grade Unit
%
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 20.6 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 69.9Grade Unit: g/tIntercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
69.9
Grade Unit
g/t
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 69.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 775.9 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“69.9”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 1.7Grade Unit: %Intercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.7
Grade Unit
%
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 18.9 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 111.7Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
111.7
Grade Unit
g/t
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 111.7 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 502.7 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“111.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 3Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
%
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 13.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.1 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 19.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
19.4
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 19.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.7 g/t·m is below.

Negative factors

  • 19.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 19.2Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
19.2
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 19.2 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 9.6 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 19.2 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.1 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.8 g/t·m is below.

Negative factors

  • 0.5 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 0.6Grade Unit: g/tIntercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 0.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · copperGrade: 2.3Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.3
Grade Unit
%
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.1 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.3 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · goldGrade: 8.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
8.1
Grade Unit
g/t
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 8.1 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 8.1 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.1”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · silverGrade: 2.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 2.8Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.8
Grade Unit
%
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 5.0 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2.8 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.8”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 1.6Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.6
Grade Unit
g/t
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.9 g/t·m is below.

Negative factors

  • 1.6 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.6”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 3.4Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.1 g/t·m is below.

Negative factors

  • 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.