1911 Gold Intersects Significant Grades at L10 Zone, Including 10.73 g/t Au over 8.90 m and 50.61 g/t Au over 1.60 m, and Confirms Link to Larger 710-711 Zone at True North
Original announcement by prospectors_exchange on
- Company
- 1911 Gold Corporation
- Ticker
- AUMB
- Exchange
- Unavailable
- Region
- Manitoba, Canada
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-09-16 17:11:16 UTC
Analysis by Minestarters Atlas
Atlas analysis published:
Minestarters Atlas analysis
Summary
1911 Gold Corporation announced significant high-grade gold assay results from its underground resource expansion drill program at the True North Gold Project in Manitoba, Canada. Highlights include 10.73 g/t Au over 8.90 m and 50.61 g/t Au over 1.60 m, which confirm a critical geological link between the L10 Zone and the larger 710-711 Zone, extending mineralization outside the current resource. These results will be incorporated into a global mineral resource estimate expected in Q4/2026, supporting the project's growth potential.
Reasoning: The drill results demonstrate exceptional high-grade gold intercepts that significantly extend known mineralization and confirm a critical geological link, providing strong upside for resource expansion and future economic studies. The robust QA/QC procedures and QP sign-off bolster confidence in the results.
Positive factors
- High-grade gold intercepts, including 50.61 g/t Au over 1.60 m and 10.73 g/t Au over 8.90 m, significantly exceed prior project averages and best grade-thickness values.
- Drilling successfully confirmed the geological link between the L10 Zone and the larger 710-711 Zone, extending mineralization outside the current mineral resource estimate.
- The results will be incorporated into an upcoming global mineral resource estimate, indicating potential for resource growth and de-risking.
- The program is focused on resource expansion and infill/delineation, supporting future mine planning and a Preliminary Economic Assessment (PEA).
Negative factors
- Intervals represent downhole lengths and are considered to be 60% to 90% of true widths, indicating some uncertainty in true thickness.
Facts used in scoring: 44
Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC procedures including insertion of certified reference materials and blanks, and third-party check assays at ALS-Chemex Laboratory.
Evidence · text
“Certified gold reference material samples are inserted every 20 samples and blank samples at intervals of one in every 50 samples, with additional blanks inserted after samples hosting visible gold. Repeat third-party gold analyses for 5% of all submitted sample pulps are analyzed at ALS-Chemex Laboratory, North Vancouver, Canada.”
QP/CP Signedpositive · Story-specific tag
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: The news release states that the scientific and technical information has been reviewed and approved by Mr. Michele Della Libera, P.Geo, Vice-President Exploration of 1911 Gold Corporation, who is a 'Qualified Person' as defined under NI 43-101.
Evidence · text
“The scientific and technical information in this news release has been reviewed and approved by Mr. Michele Della Libera, P.Geo, Vice-President Exploration of 1911 Gold Corporation, who is a “Qualified Person” as defined under NI 43-101.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: The release clearly states the cut-off grade of 2.25 g/t Au and a maximum internal dilution of 2.50 m used for reporting intercepts.
Evidence · text
“Intercepts above a cut-off grade of 2.25 g/t Au Maximum of 2.50 m internal dilution and no top capping applied”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The document states that intervals represent drill core length and are considered to represent 60% to 90% of true widths, meaning true width is not explicitly stated for each intercept.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drill program targeted the potential link between the L10 Zone and the larger 710-711 Zone, outside of the current mineral resources, confirming extensions of gold mineralization.
Evidence · text
“underground resource expansion drill program targeting the potential link between the L10 Zone (“ L10 ”), and the larger 710-711 Zone (“ 710-711 ”), outside of the current mineral resources”
Extracted facts
Stored fact records: 44. Some facts used in scoring do not have a stored record.
Drill Results (44)
UG16-26-068True North · goldGrade: 2.95Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.95
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 83.7 m
- To
- 84.3 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:83.7-84.3
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept is below the stated cut-off grade and is narrow, making it less material, though it contributes to the overall understanding of the vein system.
Negative factors
- Grade is below the stated cut-off grade of 2.25 g/t Au, making it a marginal intercept.
- The intercept length is narrow (0.6 m).
Evidence · table
“2.95”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 5.98Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 5.98
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 148 m
- To
- 148.6 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:148-148.6
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows strong gold grade for an underground setting, contributing positively to the understanding of the vein system, despite its narrow width.
Positive factors
- The grade of 5.98 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.6 m).
Evidence · table
“5.98”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 4.71Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 4.71
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 150.7 m
- To
- 152.7 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:150.7-152.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept provides a moderate gold grade over a narrow width, contributing to the overall understanding of the vein system.
Positive factors
- The grade of 4.71 g/t Au is moderate for an underground gold deposit.
Evidence · table
“4.71”
Context: 2.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 3.58Grade Unit: g/tIntercept: 3.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.58
- Grade Unit
- g/t
- Intercept
- 3.6 m
- From
- 193 m
- To
- 196.6 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:193-196.6
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept provides a moderate gold grade over a moderate width, contributing to the overall understanding of the vein system.
Positive factors
- The intercept length of 3.6 m is moderate.
Evidence · table
“3.58”
Context: 3.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 10.6Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 10.6
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 193.5 m
- To
- 194 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:193.5-194
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 10.60 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“10.60”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 2.26Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.26
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 208.3 m
- To
- 212.1 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:208.3-212.1
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept is at the stated cut-off grade, making it marginal, though it contributes to the overall understanding of the vein system.
Negative factors
- Grade is at the stated cut-off grade of 2.25 g/t Au, making it a marginal intercept.
Evidence · table
“2.26”
Context: 3.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 6.84Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 6.84
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 211.6 m
- To
- 212.1 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:211.6-212.1
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 6.84 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“6.84”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 2.49Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.49
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 257.9 m
- To
- 258.9 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:257.9-258.9
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.49”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-068True North · goldGrade: 2.71Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UG16-26-068
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.71
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 263.2 m
- To
- 264.1 m
- Hole Depth
- 351 m
- Intercept Depth
- 83.7 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-068:263.2-264.1
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 190 °
- Dip
- -35 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.71”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-070True North · goldGrade: 2.59Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-070
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.59
- Grade Unit
- g/t
- Intercept
- 1.8 m
- From
- 141.6 m
- To
- 143.4 m
- Hole Depth
- 363 m
- Intercept Depth
- 141.6 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-070:141.6-143.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 175 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.59”
Context: 1.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-070True North · goldGrade: 2.73Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-070
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.73
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 189.7 m
- To
- 190.4 m
- Hole Depth
- 363 m
- Intercept Depth
- 141.6 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-070:189.7-190.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656054
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 175 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.73”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 2.76Grade Unit: g/tIntercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.76
- Grade Unit
- g/t
- Intercept
- 1.7 m
- From
- 142.3 m
- To
- 144 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:142.3-144
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.76”
Context: 1.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 3.3Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.3
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 189.8 m
- To
- 190.6 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:189.8-190.6
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“3.30”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 2.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 225.5 m
- To
- 226 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:225.5-226
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.80”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 10.73Grade Unit: g/tIntercept: 8.9 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 10.73
- Grade Unit
- g/t
- Intercept
- 8.9 m
- From
- 245.3 m
- To
- 254.2 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:245.3-254.2
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This is a highly material intercept with strong grade over a good width, significantly exceeding prior project performance and indicating excellent potential for resource expansion.
Positive factors
- The grade of 10.73 g/t Au is strong for an underground gold deposit.
- The intercept length of 8.9 m is moderate, indicating good continuity.
- The grade-thickness product (95.597 g/t·m) is exceptional, significantly exceeding prior bests for the project.
Evidence · table
“10.73”
Context: 8.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade-thickness product of 95.597 g/t·m is exceptional, significantly exceeding the 30 g/t·m threshold for underground gold.
Evidence · table
“10.73”
Context: 8.90
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 16.12Grade Unit: g/tIntercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 16.12
- Grade Unit
- g/t
- Intercept
- 5.4 m
- From
- 245.3 m
- To
- 250.7 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:245.3-250.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval represents an exceptional high-grade zone within the broader intercept, significantly contributing to the overall positive results and resource expansion potential.
Positive factors
- The grade of 16.12 g/t Au is exceptional for an underground gold deposit.
- The intercept length of 5.4 m is moderate, indicating good continuity.
- The grade-thickness product (87.048 g/t·m) is exceptional, significantly exceeding prior bests for the project.
Evidence · table
“16.12”
Context: 5.40
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 16.12 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“16.12”
Context: 5.40
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 14.2Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 14.2
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 245.9 m
- To
- 246.7 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:245.9-246.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its narrow width.
Positive factors
- The grade of 14.20 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.8 m).
Evidence · table
“14.20”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 12.6Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 12.6
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 246.7 m
- To
- 247.4 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:246.7-247.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its narrow width.
Positive factors
- The grade of 12.60 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.7 m).
Evidence · table
“12.60”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 17.6Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 17.6
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 248.2 m
- To
- 249 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:248.2-249
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade, significantly enhancing the overall prospectivity of the broader intercept, despite its narrow width.
Positive factors
- The grade of 17.60 g/t Au is exceptional for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.8 m).
Evidence · table
“17.60”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 17.60 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“17.60”
Context: 0.80
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-072True North · goldGrade: 49.5Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-072
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 49.5
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 249.9 m
- To
- 250.7 m
- Hole Depth
- 300 m
- Intercept Depth
- 142.3 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-072:249.9-250.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 184 °
- Dip
- -64 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval represents a bonanza-grade intercept, significantly enhancing the overall prospectivity of the broader intercept and indicating very high-grade mineralization.
Positive factors
- The grade of 49.50 g/t Au is exceptional for an underground gold deposit, indicating a bonanza intercept.
Negative factors
- The intercept length is narrow (0.8 m).
Evidence · table
“49.50”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 49.50 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“49.50”
Context: 0.80
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 3.13Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.13
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 179.9 m
- To
- 180.5 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:179.9-180.5
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“3.13”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 3.6Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.6
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 186 m
- To
- 186.7 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:186-186.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“3.60”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 8.72Grade Unit: g/tIntercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 8.72
- Grade Unit
- g/t
- Intercept
- 1.7 m
- From
- 189.3 m
- To
- 191 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:189.3-191
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade over a narrow width, contributing positively to the understanding of the vein system.
Positive factors
- The grade of 8.72 g/t Au is strong for an underground gold deposit.
Evidence · table
“8.72”
Context: 1.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 19.7Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 19.7
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 190.4 m
- To
- 191 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:190.4-191
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade, significantly enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 19.70 g/t Au is exceptional for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.6 m).
Evidence · table
“19.70”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 19.70 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“19.70”
Context: 0.60
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 5.56Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 5.56
- Grade Unit
- g/t
- Intercept
- 1.8 m
- From
- 333.7 m
- To
- 335.5 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:333.7-335.5
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade over a narrow width, contributing positively to the understanding of the vein system.
Positive factors
- The grade of 5.56 g/t Au is strong for an underground gold deposit.
Evidence · table
“5.56”
Context: 1.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 7.9Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 7.9
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 333.7 m
- To
- 334.4 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:333.7-334.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its narrow width.
Positive factors
- The grade of 7.90 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.7 m).
Evidence · table
“7.90”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-074True North · goldGrade: 7.98Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-074
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 7.98
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 335 m
- To
- 335.5 m
- Hole Depth
- 405 m
- Intercept Depth
- 179.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-074:335-335.5
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 166 °
- Dip
- -70 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 7.98 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“7.98”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 3.43Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.43
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 206.9 m
- To
- 207.6 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:206.9-207.6
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“3.43”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 3.19Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 3.19
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 211.5 m
- To
- 212.3 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:211.5-212.3
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“3.19”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 50.61Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 50.61
- Grade Unit
- g/t
- Intercept
- 1.6 m
- From
- 219.2 m
- To
- 220.8 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:219.2-220.8
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This is a highly material bonanza-grade intercept, significantly exceeding prior project performance and indicating excellent potential for resource expansion.
Positive factors
- The grade of 50.61 g/t Au is exceptional for an underground gold deposit, indicating a bonanza intercept.
- The grade-thickness product (80.976 g/t·m) is exceptional, significantly exceeding prior bests for the project.
Evidence · table
“50.61”
Context: 1.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 50.61 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“50.61”
Context: 1.60
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 65.8Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 65.8
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 219.2 m
- To
- 220.2 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:219.2-220.2
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval represents a bonanza-grade intercept, significantly enhancing the overall prospectivity of the broader intercept and indicating very high-grade mineralization.
Positive factors
- The grade of 65.80 g/t Au is exceptional for an underground gold deposit, indicating a bonanza intercept.
Evidence · table
“65.80”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 65.80 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“65.80”
Context: 1.00
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 25.3Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 25.3
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 220.2 m
- To
- 220.8 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:220.2-220.8
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade, significantly enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 25.30 g/t Au is exceptional for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.6 m).
Evidence · table
“25.30”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 25.30 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“25.30”
Context: 0.60
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 2.24Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.24
- Grade Unit
- g/t
- Intercept
- 4.1 m
- From
- 309.7 m
- To
- 313.8 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:309.7-313.8
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept is below the stated cut-off grade, making it marginal, though it contributes to the overall understanding of the vein system.
Negative factors
- Grade is below the stated cut-off grade of 2.25 g/t Au, making it a marginal intercept.
Evidence · table
“2.24”
Context: 4.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-076True North · goldGrade: 2.9Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UG16-26-076
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.9
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 320.5 m
- To
- 321.4 m
- Hole Depth
- 354 m
- Intercept Depth
- 206.9 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-076:320.5-321.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313512
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 215 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.90”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-077True North · goldGrade: 4.31Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-077
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 4.31
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 173.8 m
- To
- 174.5 m
- Hole Depth
- 441 m
- Intercept Depth
- 173.8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-077:173.8-174.5
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 176 °
- Dip
- -83 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“4.31”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-077True North · goldGrade: 16.3Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-077
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 16.3
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 178.8 m
- To
- 179.4 m
- Hole Depth
- 441 m
- Intercept Depth
- 173.8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-077:178.8-179.4
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 176 °
- Dip
- -83 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows an exceptional gold grade, significantly enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 16.30 g/t Au is exceptional for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.6 m).
Evidence · table
“16.30”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 16.30 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“16.30”
Context: 0.60
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-077True North · goldGrade: 4.05Grade Unit: g/tIntercept: 3.7 mView all detailsHide details
Identity
- Hole ID
- UG16-26-077
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 4.05
- Grade Unit
- g/t
- Intercept
- 3.7 m
- From
- 214 m
- To
- 217.7 m
- Hole Depth
- 441 m
- Intercept Depth
- 173.8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-077:214-217.7
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 176 °
- Dip
- -83 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a moderate width, contributing to the overall understanding of the vein system.
Positive factors
- The intercept length of 3.7 m is moderate.
Evidence · table
“4.05”
Context: 3.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-077True North · goldGrade: 20.9Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-077
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 20.9
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 214.7 m
- To
- 215.2 m
- Hole Depth
- 441 m
- Intercept Depth
- 173.8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-077:214.7-215.2
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 176 °
- Dip
- -83 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade, significantly enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 20.90 g/t Au is exceptional for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“20.90”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The grade of 20.90 g/t Au is exceptional for an underground gold deposit (threshold >= 15 g/t Au).
Evidence · table
“20.90”
Context: 0.50
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-077True North · goldGrade: 9.33Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- UG16-26-077
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 9.33
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 375.4 m
- To
- 376 m
- Hole Depth
- 441 m
- Intercept Depth
- 173.8 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-077:375.4-376
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313513
- Northing
- 5656055
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 176 °
- Dip
- -83 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade, contributing positively to the understanding of the vein system, despite its very narrow width.
Positive factors
- The grade of 9.33 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.6 m).
Evidence · table
“9.33”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-080True North · goldGrade: 11.9Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- UG16-26-080
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 11.9
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 252.5 m
- To
- 253.3 m
- Hole Depth
- 411 m
- Intercept Depth
- 252.5 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-080:252.5-253.3
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313511
- Northing
- 5656056
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 247 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade, contributing positively to the understanding of the vein system, despite its narrow width.
Positive factors
- The grade of 11.90 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.8 m).
Evidence · table
“11.90”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-080True North · goldGrade: 2.66Grade Unit: g/tIntercept: 4.4 mView all detailsHide details
Identity
- Hole ID
- UG16-26-080
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 2.66
- Grade Unit
- g/t
- Intercept
- 4.4 m
- From
- 273.5 m
- To
- 277.9 m
- Hole Depth
- 411 m
- Intercept Depth
- 252.5 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-080:273.5-277.9
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313511
- Northing
- 5656056
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 247 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade slightly above the cut-off, contributing to the overall understanding of the vein system.
Evidence · table
“2.66”
Context: 4.40
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-080True North · goldGrade: 7.18Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-080
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 7.18
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 273.5 m
- To
- 274 m
- Hole Depth
- 411 m
- Intercept Depth
- 252.5 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-080:273.5-274
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313511
- Northing
- 5656056
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 247 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its very narrow width.
Positive factors
- The grade of 7.18 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“7.18”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-080True North · goldGrade: 6.11Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UG16-26-080
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 6.11
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 277 m
- To
- 277.9 m
- Hole Depth
- 411 m
- Intercept Depth
- 252.5 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-080:277-277.9
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313511
- Northing
- 5656056
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 247 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade, enhancing the overall prospectivity of the broader intercept, despite its narrow width.
Positive factors
- The grade of 6.11 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is narrow (0.9 m).
Evidence · table
“6.11”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
UG16-26-080True North · goldGrade: 7.36Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- UG16-26-080
- Project
- True North
- Commodity
- gold
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- AUMB
Geometry
- Grade
- 7.36
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 311.8 m
- To
- 312.3 m
- Hole Depth
- 411 m
- Intercept Depth
- 252.5 m
Classification
- Program
- resource
- Sample Type
- drill
- Group ID
- UG16-26-080:311.8-312.3
- Mining Method
- underground
Location
- Location
- L10/710-711 Complex Link
- Easting
- 313511
- Northing
- 5656056
- CRS
- UTM NAD83 Zone 15
- Elevation
- -465 m
- Azimuth
- 247 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories Ltd.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- blanks
Deleterious
- Deleterious Flag
- No
Compositing
- Cutoff Grade
- 2.25
- Cutoff Unit
- g/t Au
- Dilution Disclosed
- Yes
- Max Dilution
- 2.5 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-10T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade, contributing positively to the understanding of the vein system, despite its very narrow width.
Positive factors
- The grade of 7.36 g/t Au is strong for an underground gold deposit.
Negative factors
- The intercept length is very narrow (0.5 m).
Evidence · table
“7.36”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Intervals represent drill core length and are considered to represent 60% to 90% of true widths, indicating the reported length may overstate true thickness.
Evidence · text
“Intervals represent drill core length and are considered to represent 60% to 90% of true widths”
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.